Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Publication year range
1.
Anat Histol Embryol ; 52(1): 101-114, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36317584

ABSTRACT

Educational technologies in veterinary medicine aim to train veterinarians faster and improve clinical outcomes. COVID-19 pandemic, shifted face-to-face teaching to online, thus, the need to provide effective education remotely was exacerbated. Among recent technology advances for veterinary medical education, extended reality (XR) is a promising teaching tool. This study aimed to develop a case resolution approach for radiographic anatomy studies using XR technology and assess students' achievement of differential diagnostic skills. Learning objectives based on Bloom's taxonomy keywords were used to develop four clinical cases (3 dogs/1 cat) of spinal injuries utilizing CT scans and XR models and presented to 22 third-year veterinary medicine students. Quantitative assessment (ASMT) of 7 questions probing 'memorization', 'understanding and application', 'analysis' and 'evaluation' was given before and after contact with XR technology as well as qualitative feedback via a survey. Mean ASMT scores increased during case resolution (pre 51.6% (±37%)/post 60.1% (± 34%); p < 0.01), but without significant difference between cases (Kruskal-Wallis H = 2.18, NS). Learning objectives were examined for six questions (Q1-Q6) across cases (C1-4): Memorization improved sequentially (Q1, 2 8/8), while Understanding and Application (Q3,4) showed the greatest improvement (26.7%-76.9%). Evaluation and Analysis (Q5,6) was somewhat mixed, improving (5/8), no change (3/8) and declining (1/8).Positive student perceptions suggest that case studies' online delivery was well received stimulating learning in diagnostic imaging and anatomy while developing visual-spatial skills that aid understanding cross-sectional images. Therefore, XR technology could be a useful approach to complement radiological instruction in veterinary medicine.


Subject(s)
Cat Diseases , Dog Diseases , Education, Distance , Education, Veterinary , Students, Medical , Animals , Dogs , Humans , COVID-19/epidemiology , Dog Diseases/diagnostic imaging , Learning , Pandemics , Tomography, X-Ray Computed/veterinary , Cat Diseases/diagnostic imaging , Education, Veterinary/organization & administration , Students, Medical/psychology , Education, Distance/organization & administration , Educational Measurement
2.
Front Vet Sci ; 10: 1232635, 2023.
Article in English | MEDLINE | ID: mdl-38292132

ABSTRACT

Background: Pulmonary atelectasis is a commonly occurs during anesthesia. In these cases, mechanical ventilation (MV) associated with alveolar recruitment maneuvers (ARMs) and positive end-expiratory pressure (PEEP) is indicated to reverse the condition, ensure adequate gas exchange and improve oxygenation. ARMs can trigger volutrauma, barotrauma, and atelectrauma. Therefore, computed tomography (CT) is the gold-standard method for monitoring lung aeration after ARM. Objective: To evaluate lung volume distribution after stepwise ARMs using computed tomography (CT). Methods: Twelve dogs weighing 24.0 ± 6.0 kg, aged 3 ± 1 years, of both sexes and different breeds, underwent orchiectomy or ovariohysterectomy. The animals were anesthetized and ventilated in volume-controlled mode. ARMs were then initiated by positive end-expiratory pressure (PEEP) titration (5, 10, 15, and 20 cmH2O). CT scans, cardiovascular parameters, and ventilatory mechanics were evaluated at all time points. Data were assessed for normality using the Shapiro-Wilk test and a two-way analysis of variance, followed by a post-hoc Bonferroni test to identify differences between time points. Statistical significance was attributed to a value of p of <0.05. Results: CT demonstrated that the ARMs increased ventilation throughout the lung, including the dependent regions, with volumes that increased and decreased proportionally with PEEP titration. When they reached PEEP 10 and 5 cmH2O descending (d), they remained significantly higher than those in PEEP 0 cmH2O (baseline). Static compliance improved about 40% at PEEP 10d and PEEP 5d compared to baseline. There was an increase in heart rate (HR) from PEEP 15 increasing (i) (74.5%) to PEEP 10d (54.8%) compared to baseline. Mean arterial blood pressure (MABP) decreased approximately 9% from PEEP 15i to PEEP 15d compared to baseline. Conclusion: Lung attenuation and regional and global volumes assessed by CT showed that maximum pulmonary aeration distribution followed by PEEP titration occurred at PEEP 20 cmH2O, maintaining the lungs normoaerated and without hyperaeration.

3.
Pesqui. vet. bras ; 35(9): 801-810, Sept. 2015. tab, graf
Article in Portuguese | LILACS | ID: lil-767742

ABSTRACT

Meios de contraste iodado podem promover efeitos hemodinâmicos relacionados à vasoconstrição intrarrenal prolongada e redução da perfusão, predispondo à hipóxia e isquemia medular. Alterações de resistência vascular renal podem representar os primeiros sinais de mudança funcional desse órgão. A técnica Doppler pulsado é considerada acessível, não invasiva e permite avaliar a dinâmica vascular dos rins, por meio da aferição dos índices de resistividade (IR) e pulsatilidade (IP). Contudo, na espécie canina, a aquisição de traçados espectrais pode ser penosa devido às dificuldades de varredura e captação de sinal Doppler, sobretudo em relação ao rim direito, devido à sua localização dorsocranial na cavidade abdominal, o que prolonga substancialmente a realização do exame. O objetivo deste estudo é comprovar que a avaliação Doppler pulsado das artérias intrarrenais do rim esquerdo de cães representa a repercussão hemodinâmica renal da administração intravenosa de meios de contraste iodado não sendo necessária a realização do exame nos dois rins. Foram avaliados ambos os rins de seis cadelas adultas em quatro momentos distintos: antes da infusão intravenosa do contraste radiológico e após 1,5 horas, 24 horas e 48 horas, por meio da análise subjetiva da morfologia, ecogenicidade cortical e grau de perfusão renais e análise objetiva do comprimento, volume e resistência vascular intrarrenais (IR e IP). Os parâmetros avaliados ao modo B e Doppler dos rins direito e esquerdo não apresentaram diferenças estatisticamente significativas entre si em cada momento avaliado. Assim, constatou-se que o exame ultrassonográfico Doppler pulsado do rim esquerdo representou a repercussão hemodinâmica renal da aplicação intravenosa de meios de contraste iodado, desde que morfometria, morfologia, ecogenicidade cortical e perfusão de ambos os rins fossem consideradas semelhantes na abordagem ultrassonográfica inicial...


Iodinated contrast media can provide hemodynamic effects related to prolonged intrarenal vasoconstriction and reduced perfusion, predisposing to hypoxia and medular ischemia. Changes in the renal vascular resistance may represent the first sign of impaired renal function. Pulsed wave Doppler sonography is low cost, non-invasive and allows renal hemodynamic evaluation by resistivity (RI) and pulsatility (PI) indices. However in dogs, spectral Doppler waveform may be hard to obtain due to scanning difficulties and lack of signal Doppler. This fact occurs mostly in the right kidney because of its cranial and dorsal position in the abdominal cavity and may prolong the exam. The purpose of this study is to prove that the pulsed wave Doppler interrogation of the canine left kidney intrarenal arteries represent the renal hemodynamic effects of intravenous administration of iodinated contrast media and is not necessary to perform the exam in both kidneys. Right and left kidneys of six adult dogs were evaluated at four different times: before intravenous contrast infusion and after 1.5 hours, 24 hours and 48 hours, subjectively by using renal morphology, cortical echogenicity and renal perfusion, and objectively by using renal length, renal volume and intrarenal vascular resistance (RI and PI). No significant differences were noted between the parameters assessed by B mode and Doppler sonography of the right and left kidney in each evaluated moment. Thus, it was noted that pulsed wave Doppler sonographic evaluation of the left kidney represented the renal hemodynamic response of intravenous iodinated contrast media administration, only if both kidneys presented similar morphometry, morphology, cortical echogenicity, and perfusion during the first assessment...


Subject(s)
Animals , Female , Dogs , Kidney , Ultrasonography, Doppler, Pulsed , Ultrasonography, Doppler, Pulsed/veterinary , Ultrasonography , Ultrasonography/veterinary , Renal Artery , Hemodynamics , Contrast Media
SELECTION OF CITATIONS