1.
Comput Biol Med ; 178: 108772, 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38917532

ABSTRACT

BACKGROUND: Despite the recent advances in computational fluid dynamics (CFD) techniques applied to blood flow within the left atrium (LA), the relationship between atrial geometry, flow patterns, and blood stasis within the left atrial appendage (LAA) remains unclear. A better understanding of this relationship would have important clinical implications, as thrombi originating in the LAA are a common cause of stroke in patients with atrial fibrillation (AF). AIM: To identify the most representative atrial flow patterns on a patient-specific basis and study their influence on LAA blood stasis by varying the flow split ratio and some common atrial modeling assumptions. METHODS: Three recent techniques were applied to nine patient-specific computational fluid dynamics (CFD) models of patients with AF: a kinematic atrial model to isolate the influence of wall motion because of AF, projection on a universal LAA coordinate system, and quantification of stagnant blood volume (SBV). RESULTS: We identified three different atrial flow patterns based on the position of the center of the main circulatory flow. The results also illustrate how atrial flow patterns are highly affected by the flow split ratio, increasing the SBV within the LAA. As the flow split ratio is determined by the patient's lying position, the results suggest that the most frequent position adopted while sleeping may have implications for the medium- and long-term risks of stroke.

2.
Int J Numer Method Biomed Eng ; 40(6): e3822, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38566253

ABSTRACT

We examined the effect of minimal lumen segmentation uncertainty on Fractional Flow Reserve obtained from Coronary Computed Tomography Angiography FFR CT . A total of 14 patient-specific coronary models with different stenosis locations and degrees of severity were enrolled in this study. The optimal segmented coronary lumens were disturbed using intra ± 6 % and inter-operator ± 15 % variations on the segmentation threshold. FFR CT was evaluated in each case by 3D-OD CFD simulations. The findings suggest that the sensitivity of FFR CT to this type of uncertainty increases distally and with the stenosis severity. Cases with moderate or severe distal coronary lesions should undergo either exact and thorough segmentation operations or invasive FFR measurements, particularly if the FFR CT is close to the cutoff (0.80). Therefore, we conclude that it is crucial to consider the lesion's location and degree of severity when evaluating FFR CT results.


Subject(s)
Coronary Vessels , Fractional Flow Reserve, Myocardial , Humans , Fractional Flow Reserve, Myocardial/physiology , Coronary Vessels/diagnostic imaging , Coronary Vessels/physiopathology , Models, Cardiovascular , Computed Tomography Angiography , Coronary Angiography , Male , Uncertainty , Female , Middle Aged , Computer Simulation , Coronary Stenosis/physiopathology , Coronary Stenosis/diagnostic imaging , Aged , Tomography, X-Ray Computed
3.
ArXiv ; 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-37873014

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia, affecting over 1% of the population. It is usually triggered by irregular electrical impulses that cause the atria to contract irregularly and ineffectively. It increases blood stasis and the risk of thrombus formation within the left atrial appendage (LAA) and aggravates adverse atrial remodeling. Despite recent efforts, LAA flow patterns representative of AF conditions and their association with LAA stasis remain poorly characterized. AIM: To develop reduced-order data-driven models of LAA flow patterns during atrial remodeling in order to uncover flow disturbances concurrent with LAA stasis that could add granularity to clinical decision criteria. METHODS: We combined a geometric data augmentation process with projection of results from 180 CFD atrial simulations on a universal LAA coordinate (ULAAC) system. The projection approach enhances data visualization and facilitates direct comparison between different anatomical and functional states. ULAAC projections were used as input for a proper orthogonal decomposition (POD) algorithm to build reduced-order models of hemodynamic metrics, extracting flow characteristics associated with AF and non-AF anatomies. RESULTS: We verified that the ULAAC system provides an adequate representation to visualize data distributions on the LAA surface and to build POD-based reduced-order models. These models revealed significant differences in LAA flow patterns for atrial geometries that underwent adverse atrial remodeling and experienced elevated blood stasis. Together with anatomical morphing-based patient-specific data augmentation, this approach could facilitate data-driven analyses to identify flow features associated with thrombosis risk due to atrial remodeling.

4.
Comput Biol Med ; 133: 104423, 2021 06.
Article in English | MEDLINE | ID: mdl-33957460

ABSTRACT

BACKGROUND: Recently, advances in medical imaging, segmentation techniques, and high-performance computing have supported the use of patient-specific computational fluid dynamics (CFD) simulations. At present, CFD-compatible atrium geometries can be easily reconstructed from atrium images, providing important insight into the atrial fibrillation (AF) phenomenon, and assistance during therapy selection and surgical procedures. However, the hypothesis assumed for such CFD models should be adequately validated. AIM: This work aims to perform an extensive study of the different hypotheses that are commonly assumed when performing atrial simulations for AF patients, as well as to evaluate and compare the range of indices that are usually applied to assess thrombus formation within the left atrium appendage (LAA). METHODS: The atrial geometries of two AF patients have been segmented. The resulting geometries have been registered and interpolated to construct a dynamic mesh, which has been employed to compare the rigid and flexible models. Two families of hemodynamic indices have been calculated and compared: wall shear-based and blood age distribution-based. RESULTS: The findings of this study illustrate the importance of validating the rigid atrium hypothesis when utilizing an AF CFD model. In particular, the absence of the A-wave contraction does not avoid a certain degree of passive atrial contraction, making the rigid model a poor approximation in some cases. Moreover, a new thrombosis predicting index has been proposed, i.e., M4, which has been shown to predict stasis more effectively than other indicators.