1.
Opt Lett ; 45(7): 1611-1614, 2020 Apr 01.
Article in English | MEDLINE | ID: mdl-32235955

ABSTRACT

In this Letter, the development of a custom-designed incoherent broadband cavity enhanced absorption spectrometer (IBBCEAS) and its application to in situ measurement of aerosol extinction near the ground surface are described in an effort to address the issue of missing data in the light detection and ranging (lidar) blind zone in the first hundreds of meters of the observation range. Combined measurements of aerosol extinction at the same location using lidar remote sensing at 355 nm and in situ IBBCEAS operating in the UV spectral region around 370 nm showed results with a good correlation (${{\rm R}^2} = {0.90}$R2=0.90) between the two measurement techniques. This Letter highlights a new strategy for near-end lidar calibration, using a ground-based compact and robust IBBCEAS located at the lidar measurement site to determine the vertical profile of the aerosol extinction coefficient with a higher accuracy.

2.
Anal Chem ; 92(6): 4512-4517, 2020 03 17.
Article in English | MEDLINE | ID: mdl-32083471

ABSTRACT

A compact isotope ratio sensor based on laser absorption spectroscopy at 2.7 µm was developed for high precision and simultaneous measurements of the D/H, 18O/16O and 17O/16O isotope ratios in glacier water. Measurements of the oxygen and hydrogen isotope ratios in glacier water demonstrate a 1σ precision of 0.3‰ for δ18O, 0.2‰ for δ17O, and 0.5‰ for δ2H, respectively. The δ values of the working standard glacier water obtained by the calibrated sensor system is basically identical to the IRMS measurement results with a very high calibration accuracy from 0.17‰ to 0.75‰. Preliminary results on the reproducibility measurements display a standard deviation of 0.13‰ for δ18O, 0.13‰ for δ17O, and 0.64‰ for δ2H, respectively.

3.
Sensors (Basel) ; 17(11)2017 Nov 14.
Article in English | MEDLINE | ID: mdl-29135951

ABSTRACT

Lock-in amplification (LIA) is an effective approach for recovery of weak signal buried in noise. Determination of the input signal amplitude in a classical dual-phase LIA is based on incoherent detection which leads to a biased estimation at low signal-to-noise ratio. This article presents, for the first time to our knowledge, a new architecture of LIA involving phase estimation with a linear-circular regression for coherent detection. The proposed phase delay estimate, between the input signal and a reference, is defined as the maximum-likelihood of a set of observations distributed according to a von Mises distribution. In our implementation this maximum is obtained with a Newton Raphson algorithm. We show that the proposed LIA architecture provides an unbiased estimate of the input signal amplitude. Theoretical simulations with synthetic data demonstrate that the classical LIA estimates are biased for SNR of the input signal lower than -20 dB, while the proposed LIA is able to accurately recover the weak signal amplitude. The novel approach is applied to an optical sensor for accurate measurement of NO 2 concentrations at the sub-ppbv level in the atmosphere. Side-by-side intercomparison measurements with a commercial LIA (SR830, Stanford Research Inc., Sunnyvale, CA, USA ) demonstrate that the proposed LIA has an identical performance in terms of measurement accuracy and precision but with simplified hardware architecture.

4.
Analyst ; 142(24): 4638-4646, 2017 Dec 04.
Article in English | MEDLINE | ID: mdl-28914304

ABSTRACT

A spectroscopic instrument based on a mid-infrared external cavity quantum cascade laser (EC-QCL) was developed for high-accuracy measurements of dinitrogen pentoxide (N2O5) at the ppbv-level. A specific concentration retrieval algorithm was developed to remove, from the broadband absorption spectrum of N2O5, both etalon fringes resulting from the EC-QCL intrinsic structure and spectral interference lines of H2O vapour absorption, which led to a significant improvement in measurement accuracy and detection sensitivity (by a factor of 10), compared to using a traditional algorithm for gas concentration retrieval. The developed EC-QCL-based N2O5 sensing platform was evaluated by real-time tracking N2O5 concentration in its most important nocturnal tropospheric chemical reaction of NO3 + NO2 ↔ N2O5 in an atmospheric simulation chamber. Based on an optical absorption path-length of Leff = 70 m, a minimum detection limit of 15 ppbv was achieved with a 25 s integration time and it was down to 3 ppbv in 400 s. The equilibrium rate constant Keq involved in the above chemical reaction was determined with direct concentration measurements using the developed EC-QCL sensing platform, which was in good agreement with the theoretical value deduced from a referenced empirical formula under well controlled experimental conditions. The present work demonstrates the potential and the unique advantage of the use of a modern external cavity quantum cascade laser for applications in direct quantitative measurement of broadband absorption of key molecular species involved in chemical kinetic and climate-change related tropospheric chemistry.

5.
Opt Express ; 24(10): A781-90, 2016 May 16.
Article in English | MEDLINE | ID: mdl-27409951

ABSTRACT

We overview our recent progress in the developments and applications of light emitting diode-based incoherent broadband cavity enhanced absorption spectroscopy (LED-IBBCEAS) techniques for real-time optical sensing chemically reactive atmospheric species (HONO, NO3, NO2) in intensive campaigns and in atmospheric simulation chamber. New application of optical monitoring of NO3 concentration-time profile for study of the NO3-initiated oxidation process of isoprene in a smog chamber is reported.

6.
Sensors (Basel) ; 16(2): 224, 2016 Feb 08.
Article in English | MEDLINE | ID: mdl-26867196

ABSTRACT

A room-temperature continuous-wave (CW) quantum cascade laser (QCL)-based methane (CH4) sensor operating in the mid-infrared near 8 µm was developed for continuous measurement of CH4 concentrations in ambient air. The well-isolated absorption line (7F2,4 ← 8F1,2) of the ν4 fundamental band of CH4 located at 1255.0004 cm(-1) was used for optical measurement of CH4 concentration by direct absorption in a White-type multipass cell with an effective path-length of 175 m. A 1σ (SNR = 1) detection limit of 33.3 ppb in 218 s was achieved with a measurement precision of 1.13%. The developed sensor was deployed in a campaign of measurements of time series CH4 concentration on a site near a suburban traffic road in Dunkirk (France) from 9th to 22nd January 2013. An episode of high CH4 concentration of up to ~3 ppm has been observed and analyzed with the help of meteorological parameters combined with back trajectory calculation using the Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT) model of NOAA.


Subject(s)
Air/analysis , Environmental Monitoring , Methane/isolation & purification , France , Humans , Lasers, Semiconductor , Methane/toxicity
7.
Sensors (Basel) ; 14(5): 9027-45, 2014 May 21.
Article in English | MEDLINE | ID: mdl-24854363

ABSTRACT

A compact isotope ratio laser spectrometry (IRLS) instrument was developed for simultaneous measurements of the D/H, 18O/16O and 17O/16O isotope ratios in water by laser absorption spectroscopy at 2.73 µm. Special attention is paid to the spectral data processing and implementation of a Kalman adaptive filtering to improve the measurement precision. Reduction of up to 3-fold in standard deviation in isotope ratio determination was obtained by the use of a Fourier filtering to remove undulation structure from spectrum baseline. Application of Kalman filtering enables isotope ratio measurement at 1 s time intervals with a precision (<1‰) better than that obtained by conventional 30 s averaging, while maintaining a fast system response. The implementation of the filter is described in detail and its effects on the accuracy and the precision of the isotope ratio measurements are investigated.


Subject(s)
Oxygen Isotopes/analysis , Spectrum Analysis/methods , Water/analysis , Algorithms , Deuterium/analysis , Equipment Design , Image Processing, Computer-Assisted , Lasers , Spectrum Analysis/instrumentation , Water/chemistry
8.
Opt Express ; 19(3): 2493-501, 2011 Jan 31.
Article in English | MEDLINE | ID: mdl-21369069

ABSTRACT

We report on the development of a Faraday rotation spectroscopy (FRS) instrument using a DFB diode laser operating at 2.8 µm for the hydroxyl (OH) free radical detection. The highest absorption line intensity and the largest gJ value make the Q (1.5) double lines of the 2Π3/2 state (υ = 1 ← 0) at 2.8 µm clearly the best choice for sensitive detection in the infrared region by FRS. The prototype instrument shows shot-noise dominated performance and, with an active optical pathlength of only 25 cm and a lock-in time constant of 100 ms, achieves a 1σ detection limit of 8.2 × 10(8) OH radicals/cm3.


Subject(s)
Hydroxyl Radical/analysis , Lasers, Semiconductor , Spectrum Analysis/instrumentation , Equipment Design , Equipment Failure Analysis , Rotation
9.
Opt Lett ; 35(5): 634-6, 2010 Mar 01.
Article in English | MEDLINE | ID: mdl-20195302

ABSTRACT

Kalman adaptive filtering was applied for the first time, to our knowledge, to the real-time simultaneous determination of water isotopic ratios using laser absorption spectroscopy at 2.73 microm. Measurements of the oxygen and hydrogen isotopologue ratios delta(18)O, delta(17)O, and delta(2)H in water showed a 1-sigma precision of 0.72 per thousand for delta(18)O, 0.48 per thousand for delta(17)O, and 0.84 per thousand for delta(2)H, while sampling the output of the tuned Kalman filter at 1 s time intervals. Using a standard running average technique, averaging over approximately 30 s is required to obtain the same level of precision.

10.
Opt Lett ; 31(15): 2356-8, 2006 Aug 01.
Article in English | MEDLINE | ID: mdl-16832484

ABSTRACT

Continuous-wave terahertz spectroscopy by photomixing is applied to the analysis of mainstream cigarette smoke. Using the wide tunability of the source, spectral signatures of hydrogen cyanide (HCN), carbon monoxide (CO), formaldehyde (H2CO), and water (H2O) have been observed from 500 to 2400 GHz. The fine spectral purity allows direct concentration measurement from the pure rotational transitions of HCN and CO. The quantification of the measurement was validated by the means of a calibration gas containing CO. The potential of this technique for trace gas detection is demonstrated with an estimated detection limit of HCN equal to 9 parts in 10(6).


Subject(s)