1.
Biochem Med (Zagreb) ; 32(2): 020501, 2022 Jun 15.
Article in English | MEDLINE | ID: mdl-35464749

ABSTRACT

After the outbreak in China in the year 2019, severe acute respiratory syndrome Coronavirus 2 (SARS-CoV-2) quickly spread around the world causing a protracted pandemic. Approximately one-third of infections appear to be asymptomatic. Symptomatic disease is characterized primarily by symptoms of respiratory tract infection of varying severity. But Coronavirus Disease 2019 (COVID-19) is much more than an acute respiratory disease because SARS-CoV-2 affects many organs inducing a vast number of symptoms such as cardiovascular, neurological, gastrointestinal, dermatological, with numerous complications. Short and long-term effects of infection, severe ones, and especially mild forms of the disease which affect a huge number of patients need to be further investigated. Laboratory medicine has a crucial role in early diagnosis of the disease, recognition of the patients who need hospital care, and close monitoring of hospitalized patients to timely identify associated clinical complications as well as follow-up of patients with long-term COVID-19.


Subject(s)
COVID-19 , Pandemics , China , Humans , Laboratories , SARS-CoV-2
2.
Clin Chem Lab Med ; 60(5): 714-725, 2022 04 26.
Article in English | MEDLINE | ID: mdl-35212494

ABSTRACT

OBJECTIVES: Hemolysis is associated with erroneous or delayed results. Objectives of the study were to compare four different methods for obtaining hemolysis in vitro on three different analyzers. METHODS: Hemolysis was prepared with addition of pure hemoglobin into serum pool, osmotic shock, aspiration through blood collection needle, freezing/thawing of whole blood. Biochemistry parameters were measured in duplicate at Architect c8000 (Abbott, Abbott Park, USA), Beckman Coulter AU680 (Beckman Coulter, Brea, USA) and Cobas 6000 c501 (Roche, Mannheim, Germany), according to manufacturers' declarations. Cut-off value was defined as the highest value of H index with corresponding bias lower than acceptance criteria. RESULTS: We were not able to obtain results with freezing protocol. On all three platforms, lowest number of analytes were sensitive to hemolysis at H=0.5 using method of adding free hemoglobin. When osmotic shock was used, cut-off values for the most analytes were generally met at lower values. Hemolysis significantly interfered with measurement of potassium and lactate dehydrogenase (LD) at H=0.5 on all platforms. The most of the tested analytes had the lowest acceptable H index when aspiration method was used. At the low level of hemolysis (H=0.8) glucose, sodium, potassium, chloride, phosphate, and LD were affected on all analyzers, with some additional analytes depending on the manufacturer. CONCLUSIONS: Hemolysis interference differs on different analyzers and according to protocol for obtaining hemolysis. Aspiration method was generally the most sensitive to hemolysis interference, while addition of free Hb was the most resistant.


Subject(s)
Hemolysis , Sodium , Hematologic Tests , Hemoglobins/analysis , Humans , Serum/chemistry
3.
Clin Chem Lab Med ; 57(2): 183-194, 2018 12 19.
Article in English | MEDLINE | ID: mdl-30055099

ABSTRACT

Background Nowadays over-the-counter (OTC) drugs and dietary supplements are widely used. Their use can have a significant impact on the validity of laboratory results. The aim of this multicenter European study was to determine the frequency of consumption of various dietary products and OTC drugs among patients and explore their level of knowledge and awareness about the potential impact of various products on laboratory test results. Methods Eighteen European countries participated in this study. The survey was carried out anonymously on a subsequent series of outpatients (n=200) in each participating country. Included were patients who were referred to the laboratory for blood sampling and who voluntarily agreed to participate in the study. The survey included questions about the frequency of consumption of various products, awareness of the importance of informing physicians and laboratory staff about it and information about influence of preanalytical factors in general on laboratory test results. Results In total, 68% of patients were regularly taking at least one OTC drug or dietary supplement. The frequency of patients consuming at least one OTC drug or dietary supplement differed between countries (p=0.001). Vitamins (38%), minerals (34%), cranberry juice (20%), acetylsalicylic acid (ASA) (17%) and omega fatty acids (17%) were the most commonly used in our study. Conclusions The use of various OTC drugs and dietary supplements is highly prevalent in Europe and patients are often not willing to disclose this information to the laboratory staff and ordering physician. The education of both patients and healthcare staff is needed.


Subject(s)
Awareness , Clinical Chemistry Tests , Dietary Supplements , Knowledge , Nonprescription Drugs , Patients/psychology , Europe , Humans , Surveys and Questionnaires
4.
Clin Chem Lab Med ; 56(5): 776-788, 2018 04 25.
Article in English | MEDLINE | ID: mdl-29315074

ABSTRACT

BACKGROUND: The aim of our study was to perform verification of serum indices on three clinical chemistry platforms. METHODS: This study was done on three analyzers: Abbott Architect c8000, Beckman Coulter AU5800 (BC) and Roche Cobas 6000 c501. The following analytical specifications were verified: precision (two patient samples), accuracy (sample with the highest concentration of interferent was serially diluted and measured values compared to theoretical values), comparability (120 patients samples) and cross reactivity (samples with increasing concentrations of interferent were divided in two aliquots and remaining interferents were added in each aliquot. Measurements were done before and after adding interferents). RESULTS: Best results for precision were obtained for the H index (0.72%-2.08%). Accuracy for the H index was acceptable for Cobas and BC, while on Architect, deviations in the high concentration range were observed (y=0.02 [0.01-0.07]+1.07 [1.06-1.08]x). All three analyzers showed acceptable results in evaluating accuracy of L index and unacceptable results for I index. The H index was comparable between BC and both, Architect (Cohen's κ [95% CI]=0.795 [0.692-0.898]) and Roche (Cohen's κ [95% CI]=0.825 [0.729-0.922]), while Roche and Architect were not comparable. The I index was not comparable between all analyzer combinations, while the L index was only comparable between Abbott and BC. Cross reactivity analysis mostly showed that serum indices measurement is affected when a combination of interferences is present. CONCLUSIONS: There is heterogeneity between analyzers in the hemolysis, icteria, lipemia (HIL) quality performance. Verification of serum indices in routine work is necessary to establish analytical specifications.


Subject(s)
Bilirubin/blood , Blood Chemical Analysis , Hyperlipidemias/blood , Lipids/blood , Hemolysis , Humans , Quality of Health Care
5.
Lab Med ; 47(1): 39-42, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26732780

ABSTRACT

OBJECTIVE: To determine whether K2-ethylenediaminetetraacetic acid (EDTA) and K3-EDTA Greiner tubes could be used interchangeably for glycosylated hemoglobin, type A1C (HbA1c) measurement via the Abbott Laboratories ARCHITECT chemiluminescent microparticle HbA1c assay on the ARCHITECT i2000SR immunoanalyzer at our university hospital. MATERIALS: We drew blood from a total of 45 outpatients into plastic Greiner Vacuette tubes, some of which were lined with K2-EDTA and others with K3-EDTA anticoagulant. Data are presented as median and interquartile range values. We used the Wilcoxon test and Passing-Bablok regression for tube comparison. RESULTS: For K2-EDTA tubes median HbA1c concentration was 54 mmol/mol (41 to 71 mmol/mol) and for K3-EDTA tubes 56 mmol/mol (43 to 69 mmol/mol). There was no statistically significant difference between K2-EDTA and K3-EDTA (bias= -1.29 mmol/mol; P = 0.24). Passing-Bablok regression showed that there is no constant and proportional error: y = -0.23 (95% CI[-3.52 to 0.69]) + 1.00( 95% CI[0.98 to 1.06]) x. CONCLUSION: In this study, we provide evidence for the lack of any clinically and statistically significant bias between K2-EDTA and K3-EDTA HbA1c measurements. Thus, Greiner tubes lined with K2-EDTA and those lined with K3-EDTA can safely be used interchangeably to measure HbA1c via the Abbott Laboratories ARCHITECT assay.


Subject(s)
Diabetes Mellitus/diagnosis , Diagnostic Tests, Routine/methods , Glycated Hemoglobin/analysis , Luminescent Measurements/methods , Specimen Handling/methods , Anticoagulants/pharmacology , Hospitals, University , Humans
6.
Clin Chem Lab Med ; 54(3): 419-25, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26426892

ABSTRACT

BACKGROUND: Endogenous interferences are an important source of biased laboratory results. Hemolysis, lipemia and icteria are the main source of endogenous interference in laboratory medicine. Accreditation according to ISO 15189 improves the overall quality of the laboratory procedures. The aim of our study was i) to assess the level of knowledge of Croatian medical biochemists about the proper detection and management of hemolysis, lipemia and icteria; and ii) to identify possible differences in the level of knowledge respective to the laboratory accreditation status. METHODS: An on-line self-report survey was carried out by the Working Group for Preanalytical Phase of the Croatian Society of Medical Biochemistry and Laboratory Medicine during April to May 2015. Survey included 14 statements (Q1-Q14) about procedures for samples with interferences and participants were asked to assess the degree of agreement with the statement using a 4-point Likert scale. RESULTS: The lowest level of knowledge was observed for statements Q10 (dealing with icteric sample; 40.9% participants agreed with the correct procedure), Q12 (allowable error for interference; 47.2%) and Q11 (dealing with lipemic sample; 60.1%). Almost all participants (97.4%) agreed that laboratories in Croatia should have a harmonized protocol for management of samples with interferences. Participants from accredited laboratories showed higher knowledge of hemolysis detection (p=0.031), rejection of hemolyzed sample (p<0.001), management of icteric samples (p=0.038) and allowable error for interferences (p=0.040). CONCLUSIONS: Croatian laboratories have a good knowledge of the proper detection and management of hemolyzed, icteric and lipemic samples. Accreditation is associated with higher knowledge about management of samples with interferences.


Subject(s)
Hemolysis , Hyperlipidemias/blood , Jaundice/blood , Laboratories, Hospital/standards , Accreditation , Croatia , Humans , Surveys and Questionnaires , Workforce