Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 99
Filter
2.
Circ Arrhythm Electrophysiol ; 17(3): e012446, 2024 03.
Article in English | MEDLINE | ID: mdl-38258308

ABSTRACT

BACKGROUND: Antimicrobial envelopes reduce the incidence of cardiac implantable electronic device infections, but their cost restricts routine use in the United Kingdom. Risk scoring could help to identify which patients would most benefit from this technology. METHODS: A novel risk score (BLISTER [Blood results, Long procedure time, Immunosuppressed, Sixty years old (or younger), Type of procedure, Early re-intervention, Repeat procedure]) was derived from multivariate analysis of factors associated with cardiac implantable electronic device infection. Diagnostic utility was assessed against the existing PADIT score (Prior procedure, Age, Depressed renal function, Immunocompromised, Type of procedure) in both standard and high-risk external validation cohorts, and cost-utility models examined different BLISTER and PADIT score thresholds for TYRX (Medtronic; Minneapolis, MN) antimicrobial envelope allocation. RESULTS: In a derivation cohort (n=7383), cardiac implantable electronic device infection occurred in 59 individuals within 12 months of a procedure (event rate, 0.8%). In addition to the PADIT score constituents, lead extraction (hazard ratio, 3.3 [95% CI, 1.9-6.1]; P<0.0001), C-reactive protein >50 mg/L (hazard ratio, 3.0 [95% CI, 1.4-6.4]; P=0.005), reintervention within 2 years (hazard ratio, 10.1 [95% CI, 5.6-17.9]; P<0.0001), and top-quartile procedure duration (hazard ratio, 2.6 [95% CI, 1.6-4.1]; P=0.001) were independent predictors of infection. The BLISTER score demonstrated superior discriminative performance versus PADIT in the standard risk (n=2854, event rate: 0.8%, area under the curve, 0.82 versus 0.71; P=0.001) and high-risk validation cohorts (n=1961, event rate: 2.0%, area under the curve, 0.77 versus 0.69; P=0.001), and in all patients (n=12 198, event rate: 1%, area under the curve, 0.8 versus 0.75, P=0.002). In decision-analytic modeling, the optimum scenario assigned antimicrobial envelopes to patients with BLISTER scores ≥6 (10.8%), delivering a significant reduction in infections (relative risk reduction, 30%; P=0.036) within the National Institute for Health and Care Excellence cost-utility thresholds (incremental cost-effectiveness ratio, £18 446). CONCLUSIONS: The BLISTER score (https://qxmd.com/calculate/calculator_876/the-blister-score-for-cied-infection) was a valid predictor of cardiac implantable electronic device infection, and could facilitate cost-effective antimicrobial envelope allocation to high-risk patients.


Subject(s)
Anti-Infective Agents , Defibrillators, Implantable , Heart Diseases , Pacemaker, Artificial , Prosthesis-Related Infections , Humans , Middle Aged , Defibrillators, Implantable/adverse effects , Heart Diseases/complications , Anti-Bacterial Agents/therapeutic use , Risk Factors , Electronics , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/prevention & control , Pacemaker, Artificial/adverse effects
3.
JACC Clin Electrophysiol ; 10(1): 121-132, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37897463

ABSTRACT

BACKGROUND: There is a paucity of data comparing vitamin K antagonists (VKAs) to direct oral anticoagulants (DOACs) at the time of cardiac implantable electronic device (CIED) surgery. Furthermore, the best management of DOACs (interruption vs continuation) is yet to be determined. OBJECTIVES: This study aimed to compare the incidence of device-related bleeds and thrombotic events based on anticoagulant type (DOAC vs VKA) and regimen (interrupted vs uninterrupted). METHODS: This was an observational multicenter study. We included patients on chronic oral anticoagulation undergoing CIED surgery. Patients were matched using propensity scoring. RESULTS: We included 1,975 patients (age 73.8 ± 12.4 years). Among 1,326 patients on DOAC, this was interrupted presurgery in 78.2% (n = 1,039) and continued in 21.8% (n = 287). There were 649 patients on continued VKA. The matched population included 861 patients. The rate of any major bleeding was higher with continued DOAC (5.2%) compared to interrupted DOAC (1.7%) and continued VKA (2.1%) (P = 0.03). The rate of perioperative thromboembolism was 1.4% with interrupted DOAC, whereas no thromboembolic events occurred with DOAC or VKA continuation (P = 0.04). The use of dual antiplatelet therapy, DOAC continuation, and male sex were independent predictors of major bleeding on a multivariable analysis. CONCLUSIONS: In this large real-world cohort, a continued DOAC strategy was associated with a higher bleeding risk compared to DOAC interruption or VKA continuation in patients undergoing CIED surgery. However, DOAC interruption was associated with increased thromboembolic risk. Concomitant dual antiplatelet therapy should be avoided whenever clinically possible. A bespoke approach is necessary, with a strategy of minimal DOAC interruption likely to represent the best compromise.


Subject(s)
Platelet Aggregation Inhibitors , Thromboembolism , Aged , Aged, 80 and over , Humans , Male , Middle Aged , Anticoagulants/adverse effects , Fibrinolytic Agents , Hemorrhage/chemically induced , Hemorrhage/epidemiology , Thromboembolism/epidemiology , Thromboembolism/prevention & control , Thromboembolism/etiology , Vitamin K , Female
4.
Am Heart J ; 269: 56-71, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38109985

ABSTRACT

BACKGROUND: To date, there are no randomized, double-blinded clinical trials comparing catheter ablation to DC cardioversion (DCCV) with medical therapy in patients with persistent atrial fibrillation (PersAF). Conducting a large-scale trial to address this question presents considerable challenges, including recruitment, blinding, and implementation. We conducted a pilot study to evaluate the feasibility of conducting a definitive placebo-controlled trial. METHODS: This prospective trial was carried out at Barts Heart Centre, United Kingdom, employing a randomized, double-blinded, placebo-controlled design. Twenty patients with PersAF (duration <2 years) were recruited, representing 10% of the proposed larger trial as determined by a power calculation. The patients were randomized in a 1:1 ratio to receive either PVI ± DCCV (PVI group) or DCCV + Placebo (DCCV group). The primary endpoint of this feasibility study was to evaluate patient blinding. Patients remained unaware of their treatment allocation until end of study. RESULTS: During the study, 35% of patients experienced recurrence of PersAF prior to completion of 12 months follow-up. Blinding was successfully maintained amongst both patients and medical staff. The DCCV group had a trend to higher recurrence and repeat procedure rate compared to the PVI group (recurrence of PersAF 60% vs 30%; p = .07 and repeat procedure 70% vs 40%; p = .4). The quality of life experienced by individuals in the PVI group showed improvement, as evidenced by enhanced scores on the AF specific questionnaire (AF PROMS) (3 [±4] vs 21 [±8]) and SF-12 mental-component raw score (51.4 [±7] vs 43.24 [±15]) in patients who maintained sinus rhythm at 12 months. CONCLUSION: This feasibility study establishes the potential for conducting a blinded, placebo-controlled trial to evaluate the efficacy of PVI versus DCCV in patients with PersAF.


Subject(s)
Angina, Stable , Atrial Fibrillation , Catheter Ablation , Percutaneous Coronary Intervention , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/drug therapy , Feasibility Studies , Quality of Life , Prospective Studies , Angina, Stable/surgery , Pilot Projects , Pulmonary Veins/surgery , Catheter Ablation/methods , Treatment Outcome , Recurrence
5.
Heart Rhythm O2 ; 4(10): 609-617, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37936670

ABSTRACT

Background: Mechanisms sustaining persistent atrial fibrillation (AF) remain unclear. Objectives: The study sought to evaluate both the clinical outcomes and response to ablation of potential drivers in patients with recurrent persistent AF recurrence following pulmonary vein isolation (PVI). Methods: A total of 100 patients with persistent AF of <2 years' duration underwent cryoballoon PVI (ECGI phenotyping of persistent AF based on driver burden and distribution to predict response to pulmonary vein isolation). Patients with documented recurrence of atrial arrhythmia within 12 months were recruited and underwent repeat PVI (if needed) followed by ablation of potential drivers (PDs) identified by electrocardiographic imaging (ECGI). PDs were defined as rotational activity >1.5 revolutions or focal activations. Cycle lengths were measured pre- and postablation. The primary outcome was freedom from atrial arrhythmia off antiarrhythmic drugs at 1 year as per guidelines. Results: Of 37 patients recruited, 26 had recurrent AF and underwent ECGI-guided ablation of PDs. An average of 6.4 ± 2.7 PDs were targeted per patient. The mean ablation time targeting PDs was 15.5 ± 6.9 minutes. An ablation response occurred in 20 patients (AF termination in 6, cycle length prolongation ≥10% in 14). At 1 year, 14 (54%) of 26 patients were free from arrhythmia, and 12 (46%) of 26 were off antiarrhythmic drugs. Considering the 96 patients who completed follow-up out of the original cohort of 100 patients undergoing cryoablation in this staged strategy, freedom from arrhythmia at 1 year following the last procedure was 72 (75%) of 96, or 70 (73%) of 96 off antiarrhythmic drugs. Conclusions: In patients with recurrent AF despite PVI, ECGI-guided ablation caused an acute response in a majority with reasonable long-term outcomes.

6.
Europace ; 25(11)2023 11 02.
Article in English | MEDLINE | ID: mdl-37738643

ABSTRACT

AIMS: Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation (AF). There are limited data on the PolarX Cryoballoon. The study aimed to establish the safety, efficacy, and feasibility of same day discharge for Cryoballoon PVI. METHODS AND RESULTS: Multi-centre study across 12 centres. Procedural metrics, safety profile, and procedural efficacy of the PolarX Cryoballoon with the Arctic Front Advance (AFA) Cryoballoon were compared in a cohort large enough to provide definitive comparative data. A total of 1688 patients underwent PVI with cryoablation (50% PolarX and 50% AFA). Successful PVI was achieved with 1677 (99.3%) patients with 97.2% (n = 1641) performed as day case procedures with a complication rate of <1%. Safety, procedural metrics, and efficacy of the PolarX Cryoballoon were comparable with the AFA cohort. The PolarX Cryoballoon demonstrated a nadir temperature of -54.6 ± 7.6°C, temperature at 30 s of -38.6 ± 7.2°C, time to -40°C of 34.1 ± 13.7 s, and time to isolation of 49.8 ± 33.2 s. Independent predictors for achieving PVI included time to reach -40°C [odds ratio (OR) 1.34; P < 0.001] and nadir temperature (OR 1.24; P < 0.001) with an optimal cut-off of ≤34 s [area under the curve (AUC) 0.73; P < 0.001] and nadir temperature of ≤-54.0°C (AUC 0.71; P < 0.001), respectively. CONCLUSIONS: This large-scale UK multi-centre study has shown that Cryoballoon PVI is a safe, effective day case procedure. PVI using the PolarX Cryoballoon was similarly safe and effective as the AFA Cryoballoon. The cryoablation metrics achieved with the PolarX Cryoballoon were different to that reported with the AFA Cryoballoon. Modified cryoablation targets are required when utilizing the PolarX Cryoballoon.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Cryosurgery/adverse effects , Cryosurgery/methods , Treatment Outcome , Time Factors , Pulmonary Veins/surgery , Catheter Ablation/methods , United Kingdom , Recurrence
7.
Circ Arrhythm Electrophysiol ; 16(9): e011870, 2023 09.
Article in English | MEDLINE | ID: mdl-37646176

ABSTRACT

BACKGROUND: Hypoxia-ischemia predisposes to atrial arrhythmia. Atrial ATP-sensitive potassium channel (KATP) modulation during hypoxia has not been explored. We investigated the effects of hypoxia on atrial electrophysiology in mice with global deletion of KATP pore-forming subunits. METHODS: Whole heart KATP RNA expression was probed. Whole-cell KATP current and action potentials were recorded in isolated wild-type (WT), Kir6.1 global knockout (6.1-gKO), and Kir6.2 global knockout (6.2-gKO) murine atrial myocytes. Langendorff-perfused hearts were assessed for atrial effective refractory period (ERP), conduction velocity, wavefront path length (WFPL), and arrhymogenicity under normoxia/hypoxia using a microelectrode array and programmed electrical stimulation. Heart histology was assessed. RESULTS: Expression patterns were essentially identical for all KATP subunit RNA across human heart, whereas in mouse, Kir6.1 and SUR2 (sulphonylurea receptor subunit) were higher in ventricle than atrium, and Kir6.2 and SUR1 were higher in atrium. Compared with WT, 6.2-gKO atrial myocytes had reduced tolbutamide-sensitive current and action potentials were more depolarized with slower upstroke and reduced peak amplitude. Action potential duration was prolonged in 6.1-gKO atrial myocytes, absent of changes in other ion channel gene expression or atrial myocyte hypertrophy. In Langendorff-perfused hearts, baseline atrial ERP was prolonged and conduction velocity reduced in both KATP knockout mice compared with WT, without histological fibrosis. Compared with baseline, hypoxia led to conduction velocity slowing, stable ERP, and WFPL shortening in WT and 6.1-gKO hearts, whereas WFPL was stable in 6.2-gKO hearts due to ERP prolongation with conduction velocity slowing. Tolbutamide reversed hypoxia-induced WFPL shortening in WT and 6.1-gKO hearts through ERP prolongation. Atrial tachyarrhythmias inducible with programmed electrical stimulation during hypoxia in WT and 6.1-gKO mice correlated with WFPL shortening. Spontaneous arrhythmia was not seen. CONCLUSIONS: KATP block/absence leads to cellular and tissue level atrial electrophysiological modification. Kir6.2 global knockout prevents hypoxia-induced atrial WFPL shortening and atrial arrhythmogenicity to programmed electrical stimulation. This mechanism could be explored translationally to treat ischemically driven atrial arrhythmia.


Subject(s)
Atrial Fibrillation , KATP Channels , Humans , Animals , Mice , KATP Channels/genetics , Atrial Fibrillation/genetics , Tolbutamide , Tachycardia , Heart Atria , Hypoxia/complications , Hypoxia/genetics , Adenosine Triphosphate
8.
Front Cardiovasc Med ; 10: 1110165, 2023.
Article in English | MEDLINE | ID: mdl-37051067

ABSTRACT

Introduction: Outcomes of catheter ablation for non-paroxysmal atrial fibrillation (AF) remain suboptimal. Non-invasive stratification of patients based on the presence of atrial cardiomyopathy (ACM) could allow to identify the best responders to pulmonary vein isolation (PVI). Methods: Observational multicentre retrospective study in patients undergoing cryoballoon-PVI for non-paroxysmal AF. The duration of amplified P-wave (APW) was measured from a digitally recorded 12-lead electrocardiogram during the procedure. If patients were in AF, direct-current cardioversion was performed to allow APW measurement in sinus rhythm. An APW cut-off of 150 ms was used to identify patients with significant ACM. We assessed freedom from arrhythmia recurrence at long-term follow-up in patients with APW ≥ 150 ms vs. APW < 150 ms. Results: We included 295 patients (mean age 62.3 ± 10.6), of whom 193 (65.4%) suffered from persistent AF and the remaining 102 (34.6%) from long-standing persistent AF. One-hundred-forty-two patients (50.2%) experienced arrhythmia recurrence during a mean follow-up of 793 ± 604 days. Patients with APW ≥ 150 ms had a significantly higher recurrence rate post ablation compared to those with APW < 150 ms (57.0% vs. 41.6%; log-rank p < 0.001). On a multivariable Cox-regression analysis, APW≥150 ms was the only independent predictor of arrhythmia recurrence post ablation (HR 2.03 CI95% 1.28-3.21; p = 0.002). Conclusion: APW duration predicts arrhythmia recurrence post cryoballoon-PVI in persistent and long-standing persistent AF. An APW cut-off of 150 ms allows to identify patients with significant ACM who have worse outcomes post PVI. Analysis of APW represents an easy, non-invasive and highly reproducible diagnostic tool which allows to identify patients who are the most likely to benefit from PVI-only approach.

9.
J Cardiovasc Electrophysiol ; 34(6): 1350-1359, 2023 06.
Article in English | MEDLINE | ID: mdl-36598422

ABSTRACT

INTRODUCTION: The Heliostar™ ablation system is a novel RF balloon ablation technology with an integrated three-dimensional mapping system. Here, we describe our early experience and procedural outcomes using this technology for atrial fibrillation catheter ablation. METHODS: We sought to comprehensively assess the first 60 consecutive patients undergoing pulmonary vein isolation using the novel HELISOTAR™ RF balloon technology including procedural outcomes. A comparison of the workflow between two different anaesthetic modalities (conscious sedation [CS] vs. general anaesthesia [GA]) was made. Procedural data were collected prospectively from two high-volume centers (Barts Heart Centre, UK and University Hospital of Zurich, Zurich). A standardized approach for catheter ablation was employed. RESULTS: A total of 35 patients had the procedure under CS and the remaining under GA. Mean procedural and fluoroscopy times were 84 ± 33 min and 1.1 min. The median duration of RF energy application was 7 (5-9.8) mins per patient. All veins were successfully isolated, and the median isolation time was 10 (7-15) seconds. Our cohort's rate of procedural complications was low, with no mortality within 30 days postprocedure. CONCLUSION: Our early experience shows that catheter ablation using the Heliostar™ technology can be performed efficiently and safely; however, long-term data is yet to be established. Low fluoroscopy requirements, short learning curves and use of this technology with CS is possible, including the use of an oesophageal temperature probe.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Treatment Outcome , Europe , Electrodes , Pulmonary Veins/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods
10.
J Cardiovasc Electrophysiol ; 33(10): 2139-2151, 2022 10.
Article in English | MEDLINE | ID: mdl-35775822

ABSTRACT

INTRODUCTION: Markers predicting atrial fibrillation (AF) termination and freedom from AF/atrial tachycardia (AT) has been proposed. This study aimed to evaluate the role of novel coronary sinus (CS) electrogram characteristics in predicting the acute ablation response and freedom from AF/AT during follow-up. METHODS: Patients undergoing ablation for persistent AF as part of the Stochastic Trajectory Analysis of Ranked signals mapping study were included. Novel CS electrogram characteristics including CS cycle length variability (CLV) and CS activation pattern stability (APS) and proportion of low voltage zones (LVZs) were reviewed as potential predictors for AF termination on ablation and freedom from AF/AT during follow-up. The relationship between localized driver characteristics and CS electrogram characteristics was also assessed. RESULTS: Sixty-five patients were included. AF termination was achieved in 51 patients and 80% of patients were free from AF/AT during a follow-up of 29.5 ± 3.7 months. CS CLV of <30 ms, CS APS of ≥30% and proportion of LVZ < 30% showed high diagnostic accuracy in predicting AF termination on ablation and freedom from AF/AT during follow-up (CS CLV odds ratio [OR] 25.6, area under the curve [AUC] 0.91; CS APS OR 15.9, AUC 0.94; proportion of LVZs OR 21.4, AUC 0.88). These markers were independent predictors of AF termination on ablation and AF/AT recurrence during follow-up. Ablation of a smaller number of drivers that demonstrate greater dominance strongly correlate with greater CS organization. CONCLUSION: Novel CS electrogram characteristics were independent predictors of AF termination and AF/AT recurrence during follow-up. These markers can potentially aid in predicting outcomes and guide ablation and follow-up strategies.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Coronary Sinus , Pulmonary Veins , Tachycardia, Supraventricular , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Coronary Sinus/surgery , Humans , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
11.
Europace ; 24(9): 1420-1429, 2022 10 13.
Article in English | MEDLINE | ID: mdl-35737685

ABSTRACT

AIM: Evaluate the novel PolarX Cryoballoon in atrial fibrillation (AF) catheter ablation through a propensity-matched comparison with the Arctic Front Advance (AFA). The aim was also to identify cryoablation metrics that are predictive of successful pulmonary vein isolation (PVI) with the PolarX Cryoballoon. METHODS AND RESULTS: This prospective multi-centre study included patients that underwent cryoablation for AF. All patients underwent PVI with reconnection assessed after a 30-min waiting period and adenosine. Safety, efficacy, and cryoablation metrics were compared between PolarX and a propensity-matched AFA cohort. Seventy patients were included with 278 veins treated. In total, 359 cryoablations were performed (1.3 ± 0.6 per vein) to achieve initial PVI with 205 (73.7%) veins isolating with a single cryoablation. Independent predictors for achieving initial PVI included temperature at 30 s [odds ratio (OR) 1.26; P = 0.003] and time to reach -40°C (OR 1.88; P < 0.001) with an optimal cut-off of ≤-38.5°C at 30 s [area under the curve (AUC) 0.79; P < 0.001] and ≤-40°C at ≤32.5 s (AUC 0.77; P < 0.001), respectively. Of the 278 veins, 46 (16.5%) veins showed acute reconnection. Temperature at 30 s (≤-39.5°C, OR 1.24; P = 0.002), nadir temperature (≤-53.5°C, OR 1.35; P = 0.003), and time to isolation (≤38.0 s, OR 1.18; P = 0.009) were independent predictors of sustained PVI. Combining two of these three targets was associated with reconnection in only 2-5% of PVs. Efficacy and safety of the PolarX Cryoballoon were comparable to AFA Cryoballoon, however, cryoablation metrics were significantly different. CONCLUSIONS: The PolarX Cryoballoon has a different cryoablation profile to AFA Cryoballoon. Prospective testing of these proposed targets in large outcomes studies is required.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Adenosine , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Benchmarking , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cryosurgery/adverse effects , Cryosurgery/methods , Humans , Prospective Studies , Pulmonary Veins/surgery , Recurrence , Time Factors , Treatment Outcome
12.
J Cardiovasc Electrophysiol ; 33(8): 1747-1755, 2022 08.
Article in English | MEDLINE | ID: mdl-35671359

ABSTRACT

AIMS: Cardiac tamponade is a high morbidity complication of transseptal puncture (TSP). We examined the associations of TSP-related cardiac tamponade (TRCT) for all patients undergoing left atrial ablation at our center from 2016 to 2020. METHODS AND RESULTS: Patient and procedural variables were extracted retrospectively. Cases of cardiac tamponade were scrutinized to adjudicate TSP culpability. Adjusted multivariate analysis examined predictors of TRCT. A total of 3239 consecutive TSPs were performed; cardiac tamponade occurred in 51 patients (incidence: 1.6%) and was adjudicated as TSP-related in 35 (incidence: 1.1%; 68.6% of all tamponades). Patients of above-median age [odds ratio (OR): 2.4 (1.19-4.2), p = .006] and those undergoing re-do procedures [OR: 1.95 (1.29-3.43, p = .042] were at higher risk of TRCT. Of the operator-dependent variables, choice of transseptal needle (Endrys vs. Brockenbrough, p > .1) or puncture sheath (Swartz vs. Mullins vs. Agilis vs. Vizigo vs. Cryosheath, all p > .1) did not predict TRCT. Adjusting for operator, equipment and demographics, failure to cross the septum first pass increased TRCT risk [OR: 4.42 (2.45-8.2), p = .001], whilst top quartile operator experience [OR: 0.4 (0.17-0.85), p = .002], transoesophageal echocardiogram [TOE prevalence: 26%, OR: 0.51 (0.11-0.94), p = .023], and use of the SafeSept transseptal guidewire [OR: 0.22 (0.08-0.62), p = .001] reduced TRCT risk. An increase in transseptal guidewire use over time (2016: 15.6%, 2020: 60.2%) correlated with an annual reduction in TRCT (R2 = 0.72, p < .001) and was associated with a relative risk reduction of 70%. CONCLUSIONS: During left atrial ablation, the risk of TRCT was reduced by operator experience, TOE-guidance, and use of a transseptal guidewire, and was increased by patient age, re-do procedures, and failure to cross the septum first pass.


Subject(s)
Atrial Fibrillation , Cardiac Tamponade , Catheter Ablation , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Cardiac Catheterization , Cardiac Tamponade/diagnostic imaging , Cardiac Tamponade/epidemiology , Cardiac Tamponade/etiology , Catheter Ablation/methods , Humans , Punctures/adverse effects , Retrospective Studies , Risk Factors , Treatment Outcome
13.
J Stroke Cerebrovasc Dis ; 31(7): 106474, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35544977

ABSTRACT

OBJECTIVES: Diagnosing atrial fibrillation (AF) in patients following Cryptogenic stroke (CS) has therapeutic implications that can reduce the risk of further strokes. However, it's indolent and paroxysmal nature makes this challenging. Prolonged rhythm monitoring using implantable loop recorders (ILRs) can significantly increase the AF detection rate in the clinical trial paradigm. Whether this can be translated to real-world practice is unknown. An evaluation of referral pathways, workload and real-world efficacy may help select patients and inform service development. MATERIALS AND METHODS: Retrospective review of all patients with CS referred to a tertiary electrophysiology referral hospital for ILR implantation between February 2017 and October 2020 for AF detection was conducted. The electronic health record was used to determine demographic and mortality data. Remote monitoring was used to identify AF occurrence. RESULTS: 107 patients were included. The average time from stroke to ILR implantation was 10.5 (5.9-18.6) months. The average monitoring duration was 18.1 ± 11.2 months with 15 (14.0%) patients diagnosed with AF and commenced on anticoagulation. One diagnosis were made in the first 30 days whereas 11 (73%) were made within 12 months. Paroxysmal AF episodes ranged from 6 min to 13 h. Patients with CHA2DS2-VASc >3 were more likely to have AF (20.3% vs 4.7%, p = 0.02). Age was independently associated with AF detection after multi-variate regression. 352 ± 1171 unique events were recorded per patient, 75% of which were for suspected AF. External manufacturer-led triage of transmissions reduced transmission volume by 33%. CONCLUSIONS: ILR-based AF detection rate was high among referred CS patients, despite implantation occurring relatively late. Older patients may be less likely to be referred despite positive correlation between age and AF detection. Although recording algorithms and external triage reduced transmission volume, specialist analysis was required to manage the ILR event burden.


Subject(s)
Atrial Fibrillation , Ischemic Stroke , Stroke , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Electrocardiography, Ambulatory , Humans , Referral and Consultation , Stroke/diagnosis , Stroke/etiology , Stroke/therapy
14.
JACC Clin Electrophysiol ; 8(2): 225-235, 2022 02.
Article in English | MEDLINE | ID: mdl-35210080

ABSTRACT

OBJECTIVES: The purpose of this study was to assess the performance and limitations of low-voltage zones (LVZ) localization by optimized late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) scar imaging in patients with cardiac implantable electronic devices (CIEDs). BACKGROUND: Scar evaluation by LGE-CMR can assist ventricular tachycardia (VT) ablation, but challenges with electroanatomical maps coregistration and presence of imaging artefacts from CIED limit accuracy. METHODS: A total of 10 patients underwent VT ablation and preprocedural LGE-CMR using wideband imaging. Scar was segmented from CMR pixel signal intensity maps using commercial software (ADAS-VT, Galgo Medical) with bespoke tools and compared with detailed electroanatomical maps (CARTO). Coregistration of EP and imaging-derived scar was performed using the aorta as a fiducial marker, and the impact of coregistration was determined by assessing intraobserver/interobserver variability and using computer simulations. Spatial smoothing was applied to assess correlation at different spatial resolutions and to reduce noise. RESULTS: Pixel signal intensity maps localized low-voltage zones (V <1.5 mV) with area under the receiver-operating characteristic curve: 0.82 (interquartile range [IQR]: 0.76-0.83), sensitivity 74% (IQR: 71%-77%), and specificity 78% (IQR: 73%-83%) and correlated with bipolar voltage (r = -0.57 [IQR: -0.68 to -0.42]) across patients. In simulations, small random shifts and rotations worsened LVZ localization in at least some cases. The use of the full aortic geometry ensured high reproducibility of LVZ localization (r >0.86 for area under the receiver-operating characteristic curve). Spatial smoothing improved localization of LVZ. Results for LVZ with V <0.5 mV were similar. CONCLUSIONS: In patients with CIEDs, novel wideband CMR sequences and personalized coregistration strategies can localize LVZ with good accuracy and may assist VT ablation procedures.


Subject(s)
Contrast Media , Tachycardia, Ventricular , Gadolinium , Humans , Magnetic Resonance Imaging/methods , Reproducibility of Results , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/pathology , Tachycardia, Ventricular/surgery
15.
Pacing Clin Electrophysiol ; 45(3): 365-373, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35023176

ABSTRACT

BACKGROUND: The risk factors for developing pacing induced left ventricular dysfunction (LVD) in patients with high burden of right ventricular pacing (RVP) is poorly understood. Therefore, in the present study, we aimed to assess the determinants of pacing induced LVD. METHODS: Our data were retrospectively collected from 146 patients with RVP > 40% who underwent generator change (GC) or cardiac resynchronization therapy (CRT) upgrade between 2016 and 2019 who had left ventricular ejection fraction (EF) ≥50% at initial implant. RESULTS: A total of 75 patients had CRT upgrade due to pacing induced LVD (EF < 50%) and 71 patients with preserved LV function (EF ≥ 50%) had a GC. Primary indication for pacing in both groups was complete heart block. Male predominance (p = .008), prior myocardial infarction (MI) (p = .001), atrial fibrillation (AF) (p = .009), chronic kidney disease (CKD) (p = .005), and borderline low systolic function (BLSF) (EF 50%-55%) (p = .04) were more prevalent in the CRT upgrade group. Presence of AF (odds ratio [OR] = 3.05, 95% confidence interval [CI] 1.42-6.58; p = .004), BLSF (OR = 3.8, 95% CI 1.22-11.8; p = .02), and male gender (OR = 2.41, 95% CI 1.14-5.08; p = .02) were independent predictors for RVP induced LVD. Age (OR = 1.08, 95% CI 1.02-1.14; p = .005) and BLSF (OR = 5.33, 95% CI 1.26-22.5; p = .023) were independent predictors of earlier development of LVD after implant. CONCLUSIONS: Our results suggested that AF, BLSF, and male gender are predictors for development of pacing induced LVD in patients with high RVP burden. LVD can occur at any time after pacemaker implant with BLSF and increasing age associated with earlier development of LVD.


Subject(s)
Atrial Fibrillation , Cardiac Resynchronization Therapy , Heart Failure , Ventricular Dysfunction, Left , Atrial Fibrillation/therapy , Cardiac Pacing, Artificial/methods , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy/methods , Female , Heart Failure/therapy , Humans , Male , Retrospective Studies , Risk Factors , Stroke Volume , Treatment Outcome , United Kingdom/epidemiology , Ventricular Function, Left
16.
Eur Heart J Qual Care Clin Outcomes ; 8(7): 770-777, 2022 10 26.
Article in English | MEDLINE | ID: mdl-34601557

ABSTRACT

AIM: Implantable loop recorders (ILRs) are now routinely implanted for long-term cardiac monitoring in the clinical setting. The aim of this study was to examine the real-world performance of these devices focusing on the management changes made in response to ILR-recorded data. METHODS AND RESULTS: This was a single-centre, prospective observational study of consecutive patients undergoing ILR implantation. All patients who underwent implantation of a Medtronic Reveal LINQ device from September 2017 to June 2019 at Barts Heart Centre were included. Five hundred and one patients were included. Three hundred and two (60%) patients underwent ILR implantation for an indication of pre-syncope/syncope, 96 (19%) for palpitations, 72 (14%) for atrial fibrillation (AF) detection with a history of cryptogenic stroke, and 31 (6%) for high risk of serious cardiac arrhythmia. The primary outcome of this study was that an ILR-derived diagnosis altered management in 110 patients (22%). Secondary outcomes concerned subgroup analyses by indication: in patients who presented with syncope/pre-syncope, a change in management resulting from ILR data was positively associated with age [hazard ratio (HR) 1.04, 95% confidence interval 1.02-1.06; P < 0.001] and negatively associated with a normal electrocardiogram at baseline (HR 0.54 [0.31-0.93]; P = 0.03). Few patients (1/57, 2%) aged <40 years in this group underwent device implantation, compared to 19/62 patients (31%) aged 75 years and over (P = 0.0024). Out of 183 (12%) patients, 22 in the 40-74 age range had a device implanted. Among patients who underwent ILR insertion following cryptogenic stroke, 13/72 (18%) had AF detected, leading to a decision to commence anticoagulation. CONCLUSION: These results inform the utility of ILR in the clinical setting. Diagnoses provided by ILR that lead to changes in management are rare in patients under age 40, particularly following syncope, pre-syncope, or palpitations. In older patients, new diagnoses are frequently made and trigger important changes in treatment.


Subject(s)
Atrial Fibrillation , Ischemic Stroke , Humans , Aged , Electrocardiography, Ambulatory/methods , Outpatients , Syncope/diagnosis , Syncope/epidemiology , Syncope/etiology , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Anticoagulants
17.
J Cardiovasc Electrophysiol ; 33(3): 510-526, 2022 03.
Article in English | MEDLINE | ID: mdl-34921464

ABSTRACT

INTRODUCTION: Ethanol ablation (EA) is an alternative option for subjects with ventricular arrhythmias (VAs) refractory to conventional medical and ablative treatment. However, data on the efficacy and safety of EA remain sparse. METHODS: A systematic literature search was conducted. The primary outcomes were 1) freedom from the targeted VA and 2) freedom from any VAs post-EA. Additional safety outcomes were also analyzed. RESULTS: Ten studies were selected accounting for a population of 174 patients (62.3 ± 12.5 years, 94% male) undergoing 185 procedures. The overall acute success rate of EA was 72.4% (confidence interval [CI95% ]: 65.6-78.4). After a mean follow-up of 11.3 ± 5.5 months, the incidence of relapse of the targeted VA was 24.4% (CI95% : 17.1-32.8), while any VAs post-EA occurred in 41.3% (CI95% : 33.7-49.1). The overall incidence of procedural complications was 14.1% (CI95% : 9.8-19.8), with pericardial complications and complete atrioventricular block being the most frequent. An anterograde transarterial approach was associated with a higher rate of VA recurrences and complications compared to a retrograde transvenous route; however, differences in the baseline population characteristics and in the targeted ventricular areas should be accounted. CONCLUSION: EA is a valuable therapeutic option for VAs refractory to conventional treatment and can result in 1-year freedom from VA recurrence in 60%-75% of the patients. However, anatomical or technical challenges preclude acute success in almost 30% of the candidates and the rate of complication is not insignificant, highlighting the importance of well-informed patient selection. The certainty of the evidence is low, and further research is necessary.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/surgery , Catheter Ablation/adverse effects , Ethanol/adverse effects , Female , Heart Ventricles , Humans , Male , Retrospective Studies , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Treatment Outcome
19.
JCI Insight ; 6(16)2021 08 23.
Article in English | MEDLINE | ID: mdl-34283808

ABSTRACT

BACKGROUNDEpicardial adipose tissue (EAT) directly overlies the myocardium, with changes in its morphology and volume associated with myriad cardiovascular and metabolic diseases. However, EAT's immune structure and cellular characterization remain incompletely described. We aimed to define the immune phenotype of EAT in humans and compare such profiles across lean, obese, and diabetic patients.METHODSWe recruited 152 patients undergoing open-chest coronary artery bypass grafting (CABG), valve repair/replacement (VR) surgery, or combined CABG/VR. Patients' clinical and biochemical data and EAT, subcutaneous adipose tissue (SAT), and preoperative blood samples were collected. Immune cell profiling was evaluated by flow cytometry and complemented by gene expression studies of immune mediators. Bulk RNA-Seq was performed in EAT across metabolic profiles to assess whole-transcriptome changes observed in lean, obese, and diabetic groups.RESULTSFlow cytometry analysis demonstrated EAT was highly enriched in adaptive immune (T and B) cells. Although overweight/obese and diabetic patients had similar EAT cellular profiles to lean control patients, the EAT exhibited significantly (P ≤ 0.01) raised expression of immune mediators, including IL-1, IL-6, TNF-α, and IFN-γ. These changes were not observed in SAT or blood. Neither underlying coronary artery disease nor the presence of hypertension significantly altered the immune profiles observed. Bulk RNA-Seq demonstrated significant alterations in metabolic and inflammatory pathways in the EAT of overweight/obese patients compared with lean controls.CONCLUSIONAdaptive immune cells are the predominant immune cell constituent in human EAT and SAT. The presence of underlying cardiometabolic conditions, specifically obesity and diabetes, rather than cardiac disease phenotype appears to alter the inflammatory profile of EAT. Obese states markedly alter EAT metabolic and inflammatory signaling genes, underlining the impact of obesity on the EAT transcriptome profile.FUNDINGBarts Charity MGU0413, Abbott, Medical Research Council MR/T008059/1, and British Heart Foundation FS/13/49/30421 and PG/16/79/32419.


Subject(s)
Adipose Tissue/immunology , Diabetes Mellitus/epidemiology , Obesity/epidemiology , Pericarditis/epidemiology , Pericardium/pathology , Adaptive Immunity , Adipose Tissue/cytology , Adipose Tissue/pathology , Aged , Cardiometabolic Risk Factors , Comorbidity , Coronary Artery Bypass , Coronary Artery Disease/blood , Coronary Artery Disease/epidemiology , Coronary Artery Disease/metabolism , Coronary Artery Disease/surgery , Diabetes Mellitus/blood , Diabetes Mellitus/immunology , Diabetes Mellitus/metabolism , Female , Humans , Immunophenotyping , Male , Middle Aged , Obesity/blood , Obesity/immunology , Obesity/metabolism , Pericarditis/immunology , Pericarditis/pathology , Pericardium/surgery , RNA-Seq
20.
Europace ; 23(9): 1409-1417, 2021 09 08.
Article in English | MEDLINE | ID: mdl-33930121

ABSTRACT

AIMS: Atrial fibrillation (AF) is common in hypertrophic cardiomyopathy (HCM). Data on the efficacy of catheter ablation of AF in HCM patients are sparse. METHODS AND RESULTS: Observational multicentre study in 137 HCM patients (mean age 55.0 ± 13.4, 29.1% female; 225 ablation procedures). We investigated (i) the efficacy of catheter ablation for AF beyond the initial 12 months; (ii) the available risk scores, stratification schemes and genotype as potential predictors of arrhythmia relapse, and (iii) the impact of cryoballoon vs. radiofrequency in procedural outcomes. Mean follow-up was 43.8 ± 37.0 months. Recurrences after the initial 12-month period post-ablation were frequent, and 24 months after the index procedure, nearly all patients with persistent AF had relapsed, and only 40% of those with paroxysmal AF remained free from arrhythmia recurrence. The APPLE score demonstrated a modest discriminative capacity for AF relapse post-ablation (c-statistic 0.63, 95% CI 0.52-0.75; P = 0.022), while the risk stratification schemes for sudden death did not. On multivariable analysis, left atrium diameter and LV apical aneurysm were independent predictors of recurrence. Fifty-eight patients were genotyped; arrhythmia-free survival was similar among subjects with different gene mutations. Rate of procedural complications was high (9.3%), although reducing over time. Outcome for cryoballoon and radiofrequency ablation was comparable. CONCLUSION: Very late AF relapses post-ablation is common in HCM patients, especially in those with persistent AF. Left atrium size, LV apical aneurysm, and the APPLE score might contribute to identify subjects at higher risk of arrhythmia recurrence. First-time cryoballoon is comparable with radiofrequency ablation.


Subject(s)
Atrial Fibrillation , Cardiomyopathy, Hypertrophic , Catheter Ablation , Cryosurgery , Adult , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/diagnosis , Cardiomyopathy, Hypertrophic/surgery , Catheter Ablation/adverse effects , Cryosurgery/adverse effects , Female , Heart Atria , Humans , Male , Middle Aged , Recurrence , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...