Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 112
Filter
2.
Pacing Clin Electrophysiol ; 47(2): 185-194, 2024 02.
Article in English | MEDLINE | ID: mdl-38010836

ABSTRACT

BACKGROUND: Despite its clinical benefits, patient compliance to remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) varies and remains under-studied in diverse populations. OBJECTIVE: We sought to evaluate RM compliance, clinical outcomes, and identify demographic and socioeconomic factors affecting RM in a diverse urban population in New York. METHODS: This retrospective cohort study included patients enrolled in CIED RM at Montefiore Medical Center between December 2017 and May 2022. RM compliance was defined as the percentage of days compliant to RM transmission divided by the total prescribed days of RM. Patients were censored when they were lost to follow-up or at the time of death. The cohorts were categorized into low (≤30%), intermediate (31-69%), and high (≥70%) RM compliance groups. Statistical analyses were conducted accordingly. RESULTS: Among 853 patients, median RM compliance was 55%. Age inversely affected compliance (p < .001), and high compliance was associated with guideline-directed medical therapy (GDMT) usage and implantable cardioverter defibrillator (ICD)/cardiac resynchronization defibrillator (CRTD) devices. The low-compliance group had a higher mortality rate and fewer regular clinic visits (p < .001) than high-compliance group. Socioeconomic factors did not significantly impact compliance, while Asians showed higher compliance compared with Whites (OR 3.67; 95% CI 1.08-12.43; p = .04). Technical issues were the main reason for non-compliance. CONCLUSION: We observed suboptimal compliance to RM, which occurred most frequently in older patients. Clinic visit compliance, optimal medical therapy, and lower mortality were associated with higher compliance, whereas insufficient understanding of RM usage was the chief barrier to compliance.


Subject(s)
Defibrillators, Implantable , Remote Sensing Technology , Humans , Aged , Retrospective Studies , Cardiac Resynchronization Therapy Devices , Demography
3.
Chem Commun (Camb) ; 59(96): 14197-14209, 2023 Nov 30.
Article in English | MEDLINE | ID: mdl-37955165

ABSTRACT

Materials informatics (MI) has immense potential to accelerate the pace of innovation and new product development in biotechnology. Close collaborations between skilled physical and life scientists with data scientists are being established in pursuit of leveraging MI tools in automation and artificial intelligence (AI) to predict material properties in vitro and in vivo. However, the scarcity of large, standardized, and labeled materials data for connecting structure-function relationships represents one of the largest hurdles to overcome. In this Highlight, focus is brought to emerging developments in polymer-based therapeutic delivery platforms, where teams generate large experimental datasets around specific therapeutics and successfully establish a design-to-deployment cycle of specialized nanocarriers. Three select collaborations demonstrate how custom-built polymers protect and deliver small molecules, nucleic acids, and proteins, representing ideal use-cases for machine learning to understand how molecular-level interactions impact drug stabilization and release. We conclude with our perspectives on how MI innovations in automation efficiencies and digitalization of data-coupled with fundamental insight and creativity from the polymer science community-can accelerate translation of more gene therapies into lifesaving medicines.


Subject(s)
Artificial Intelligence , Polymers , Polymers/chemistry , Machine Learning , Pharmaceutical Preparations , Informatics
4.
Curr Biol ; 32(17): 3758-3772.e4, 2022 09 12.
Article in English | MEDLINE | ID: mdl-35973432

ABSTRACT

Sweet and bitter compounds excite different sensory cells and drive opposing behaviors. However, it remains unclear how sweet and bitter tastes are represented by the neural circuits linking sensation to behavior. To investigate this question in Drosophila, we devised trans-Tango(activity), a strategy for calcium imaging of second-order gustatory projection neurons based on trans-Tango, a genetic transsynaptic tracing technique. We found spatial overlap between the projection neuron populations activated by sweet and bitter tastants. The spatial representation of bitter tastants in the projection neurons was consistent, while that of sweet tastants was heterogeneous. Furthermore, we discovered that bitter tastants evoke responses in the gustatory receptor neurons and projection neurons upon both stimulus onset and offset and that bitter offset and sweet onset excite overlapping second-order projections. These findings demonstrate an unexpected complexity in the representation of sweet and bitter tastants by second-order neurons of the gustatory circuit.


Subject(s)
Drosophila Proteins , Taste , Animals , Drosophila/physiology , Drosophila Proteins/genetics , Neurons/physiology , Taste/physiology , Taste Perception/physiology
6.
Elife ; 102021 02 11.
Article in English | MEDLINE | ID: mdl-33570489

ABSTRACT

The mushroom body (MB) is a well-characterized associative memory structure within the Drosophila brain. Analyzing MB connectivity using multiple approaches is critical for understanding the functional implications of this structure. Using the genetic anterograde transsynaptic tracing tool, trans-Tango, we identified divergent projections across the brain and convergent downstream targets of the MB output neurons (MBONs). Our analysis revealed at least three separate targets that receive convergent input from MBONs: other MBONs, the fan-shaped body (FSB), and the lateral accessory lobe (LAL). We describe, both anatomically and functionally, a multilayer circuit in which inhibitory and excitatory MBONs converge on the same genetic subset of FSB and LAL neurons. This circuit architecture enables the brain to update and integrate information with previous experience before executing appropriate behavioral responses. Our use of trans-Tango provides a genetically accessible anatomical framework for investigating the functional relevance of components within these complex and interconnected circuits.


Subject(s)
Drosophila melanogaster/physiology , Mushroom Bodies/physiology , Neurons/physiology , Animals , Female , Male
7.
Am J Cardiol ; 144: 77-82, 2021 04 01.
Article in English | MEDLINE | ID: mdl-33383004

ABSTRACT

Application of artificial intelligence techniques in medicine has rapidly expanded in recent years. Two algorithms for identification of cardiac implantable electronic devices using chest radiography were recently developed: The PacemakerID algorithm, available as a mobile phone application (PIDa) and a web platform (PIDw) and The Pacemaker Identification with Neural Networks (PPMnn), available via web platform. In this study, we assessed the relative accuracy of these algorithms. The machine learning algorithms (PIDa, PIDw, PPMnn) were used to predict device manufacturer using chest X-rays for patients with implanted devices. Each prediction was considered correct if predicted certainty was >75%. For comparative purposes, accuracy of each prediction was compared to the result using the CARDIA-X algorithm. 500 X-rays were included from a convenience sample. Raw accuracy was PIDa 89%, PIDw 73%, PPMnn 71% and CARDIA-X 85%. In conclusion, machine learning algorithms for identification of cardiac devices are accurate at determining device manufacturer, have capacity for improved accuracy with additional training sets and can utilize simple user interfaces. These algorithms have clinical utility in limiting potential infectious exposures and facilitate rapid identification of devices as needed for device reprogramming.


Subject(s)
Defibrillators, Implantable , Machine Learning , Pacemaker, Artificial , Radiography, Thoracic , Algorithms , Humans , Image Interpretation, Computer-Assisted , Neural Networks, Computer
9.
J Electrocardiol ; 62: 211-215, 2020.
Article in English | MEDLINE | ID: mdl-32992259

ABSTRACT

BACKGROUND: Wellens' sign is considered to be an ominous sign indicative of underlying significant proximal left anterior descending artery stenosis. We sought to identify the prevalence of the Wellens' pattern in a large ethnically diverse urban population and assess its association with the presence and extent of coronary artery disease. METHODS: We utilized the MUSE ECG database of Montefiore Medical Center, an academic tertiary health care system, to identify ECGs from 2012 to 2019 exhibiting a Wellens' pattern. From a dataset of 1.76 million tracings, six screening diagnosis codes were selected to approximate the Wellens' pattern. These codes were used to generate a cohort of ECGs for manual review by a board certified cardiologist to determine if a Wellens' pattern was present. RESULTS: Of 1,756,742 ECGs performed on 433,218 patients from 2012 to 2019; after initial screening 2186 ECGs were identified for manual review. Of these, 448 (0.1%) patients were confirmed to have a Wellens' pattern. 229 patients underwent cardiac catheterization, while 219 patients were managed medically. No statistical difference was seen in the occurrence of Wellens' Type A and B pattern across the ethnic groups after multivariate analysis. Women were more likely to have Type B Wellens' compared to men (OR 2.40 (1.58, 3.62) P < 0.0001). 80 (35%) patients had single vessel LAD disease of which 22 (10%) had proximal, 40 (17%) had mid, 4 (1%) had distal stenosis, while diffuse LAD disease was seen in 14 (6%) patients. Two vessel disease was seen in 46 (20%) patients with a Wellens' pattern, and triple vessel disease was seen in 23 (10%) patients. Of note, 71 (31%) patients had either normal or nonobstructive coronary disease despite exhibiting a Wellens' pattern ECG. CONCLUSION: Wellens' sign is a rare electrocardiographic pattern which when seen in a patient with an appropriate clinical presentation, suggests but is not definitive for the presence of significant coronary disease, often but not exclusively in an LAD distribution. We found no statistical difference in the occurrence of Wellens' sign among different racial/ethnic groups. Patients with a Wellens' pattern may have critical lesions at a variety of LAD sites as well as in multiple vessels. As such, the interventionalist needs to be prepared for these uncertainties at the time of cardiac catheterization.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Coronary Angiography , Coronary Artery Disease/diagnosis , Coronary Artery Disease/epidemiology , Electrocardiography , Female , Humans , Male , Prevalence , Syndrome , Urban Population
10.
Heart Rhythm ; 17(12): 2119-2125, 2020 12.
Article in English | MEDLINE | ID: mdl-32679267

ABSTRACT

BACKGROUND: Premature ventricular contractions (VPC) have hour-to-hour and day-to-day variation. High VPC burden correlates with cardiomyopathy. OBJECTIVE: To determine the optimal duration for ambulatory electrocardiogram monitoring for accurate assessment of VPC burden. METHODS: Our group performed a retrospective analysis on patch monitors used for any indication with overall VPC burden ≥5.0% between February 1, 2016, and February 1, 2020. We generated cumulative daily VPC averages for each day of wear and performed linear regression analysis between each cumulative daily average and overall burden. Patients were divided into groups based on low or high VPC frequency, and the analysis was repeated. Split-sample validation was used to internally validate the overall prediction model. RESULTS: A total of 116 patches representing 107 patients (mean age: 64.5; female: 48%) were analyzed. Mean overall VPC burden was 13.4% ± 7.5% (range: 5.0%-42.0%). Day 1 R2 was 60%, P < .001, and continued to increase to R2 88%, P < .001 at day 14. Median percent and absolute error decreased from 22.70% (interquartile range [IQR]: 9.73-34.39) and 2.58% (IQR: 1.24-4.59) at day 1 to 5.62% (IQR: 2.82-8.39) and 0.55% (IQR: 0.28-1.05) at day 14. Patients with higher overall VPC frequencies achieved a more rapid rise in R2 relative to those with lower frequencies. Split-sample validation supported the internal validity of our linear regression prediction model. CONCLUSION: Mobile telemetry for a period of ∼7 days accurately reflects overall VPC burden. Measurement of VPC burden for only 24-48 hours may not accurately reflect total burden. Monitoring for 2 weeks or longer adds little additional VPC information.


Subject(s)
Electrocardiography, Ambulatory/methods , Heart Rate/physiology , Heart Ventricles/physiopathology , Myocardial Contraction/physiology , Ventricular Function, Left/physiology , Ventricular Premature Complexes/physiopathology , Adult , Aged , Aged, 80 and over , Female , Follow-Up Studies , Humans , Male , Middle Aged , Retrospective Studies , Time Factors , Ventricular Premature Complexes/diagnosis
11.
J Interv Card Electrophysiol ; 59(2): 337-345, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32654098

ABSTRACT

PURPOSE: Hydroxychloroquine, chloroquine, and azithromycin have been used for treatment of COVID-19, but may cause QT prolongation. Minority populations are disproportionately impacted by COVID-19. This study evaluates the risk of QT prolongation and subsequent outcomes after administration of these medications in largely underrepresented minority COVID-19 patients. METHODS: We conducted an observational study on hospitalized COVID-19 patients in the Montefiore Health System (Bronx, NY). We examined electrocardiograms (ECG) pre/post-medication initiation to evaluate QTc, HR, QRS duration, and presence of other arrhythmias. RESULTS: One hundred five patients (mean age 67 years; 44.8% F) were analyzed. The median time from the first dose of any treatment to post-medication ECG was 2 days (IQR: 1-3). QTc in men increased from baseline (440 vs 455 ms, p < 0.001), as well as in women (438 vs 463 ms, p < 0.001). The proportion of patients with QT prolongation increased significantly (14.3% vs 34.3%, p < 0.001) even when adjusted for electrolyte abnormalities. The number of patients whose QTc > 500 ms was significantly increased after treatment (16.2% vs. 4.8%, p < 0.01). Patients with either QTc > 500 ms or an increase of 60 ms had a higher frequency of death (47.6% vs. 22.6%, p = 0.02) with an odds ratio of 3.1 (95% CI: 1.1-8.7). Adjusting for race/ethnicity yielded no significant associations. CONCLUSIONS: Hydroxychloroquine, chloroquine, and/or azithromycin were associated with QTc prolongation but did not result in fatal arrhythmias. Our findings suggest that any harm is unlikely to outweigh potential benefits of treatment. Careful risk-benefit analyses for individual patients should guide the use of these medications. Randomized control trials are necessary to evaluate their efficacies.


Subject(s)
Antimalarials/adverse effects , Azithromycin/adverse effects , Coronavirus Infections/drug therapy , Electrocardiography/methods , Long QT Syndrome/chemically induced , Pneumonia, Viral/drug therapy , Age Distribution , Aged , Aged, 80 and over , Antimalarials/administration & dosage , Azithromycin/administration & dosage , COVID-19 , Chloroquine/administration & dosage , Chloroquine/adverse effects , Coronavirus Infections/diagnosis , Coronavirus Infections/epidemiology , Female , Follow-Up Studies , Hospitalization/statistics & numerical data , Humans , Hydroxychloroquine/administration & dosage , Hydroxychloroquine/adverse effects , Incidence , Long QT Syndrome/diagnostic imaging , Long QT Syndrome/drug therapy , Long QT Syndrome/epidemiology , Male , Middle Aged , Pandemics/prevention & control , Pandemics/statistics & numerical data , Pneumonia, Viral/diagnosis , Pneumonia, Viral/epidemiology , Risk Assessment , Sex Distribution , Urban Population
12.
HeartRhythm Case Rep ; 6(6): 344-347, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32577392
13.
J Cardiovasc Electrophysiol ; 31(7): 1779-1783, 2020 07.
Article in English | MEDLINE | ID: mdl-32282966

ABSTRACT

BACKGROUND: Subxyphoid active left ventricular epicardial (LVE) lead implants or VT ablation are attractive but remain a challenge due to concerns of coronary artery damage. We aimed to see if Doppler-guided positioning could permit safe LVE lead placement without coronary angiography. We evaluated the feasibility of a Doppler flow-guided subxyphoid epicardial screw-in lead fixation in a swine model. METHODS: Acute subxyphoid access to the pericardial space was performed in an anesthetized swine model using a deflectable sheath and a modified needle-derived Doppler flow meter. The audio signal and visual display from the Doppler flow meter were recorded. Coronary angiography was performed to verify the catheter location. A SelectSecure Model 3830 lead (Medtronic) was used to assess pacing in the procedure. RESULTS: In both of two swine, the deflectable catheter was inserted into pericardial space via subxyphoid access. The tip of the deflectable catheter with the Doppler was directed to several locations, from quiet (no nearby coronary artery expected) to typical rhythmic pulsatile sound locations which were maximal when superimposed on a coronary artery. Repeated coronary angiograms confirmed the expected findings. A 3830 active lead was fixed into a quiet location for LVE pacing, and confirmed by angiography as distant from a coronary artery. CONCLUSIONS: Doppler-guided subxyphoid epicardial screw-in lead placement is feasible once the catheter tip is directed and stabilized in a desired LVE location. This obviates the need for repeated (or any) coronary angiography. The Doppler-guided subxyphoid epicardial procedure may also be applicable for epicardial ventricular arrhythmia ablation procedures.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Animals , Coronary Angiography , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Heart Ventricles/surgery , Pericardium/diagnostic imaging , Pericardium/surgery , Swine , Tachycardia, Ventricular/surgery
14.
Am J Med ; 133(9): e495-e500, 2020 09.
Article in English | MEDLINE | ID: mdl-32194027

ABSTRACT

BACKGROUND: Electrocardiography (ECG) is poorly sensitive, but highly specific for the diagnosis of left ventricular hypertrophy. However, previous studies documenting this were small and lacked patient diversity. Furthermore, little is known about the impact of patient characteristics on the sensitivity and specificity of ECG for left ventricular hypertrophy. To address this issue, the present study was conducted to ascertain the sensitivity and specificity of ECG for left ventricular hypertrophy in a large, diverse patient population. METHODS: We performed a retrospective cohort study using ECG and echocardiography (ECHO) data from a large metropolitan health system. All patients had one ECG and ECHO on file, obtained within 1 week of each other. Sensitivity and specificity of ECG for left ventricular hypertrophy were determined by comparing results from the MUSE® 12-SL (GE Healthcare, Chicago, IL) computer-generated algorithm for ECG to ECHO left ventricular mass index. Subgroup analyses of individual patient characteristics were performed with corresponding chi-squared analyses to determine significance. RESULTS: A total of 13,960 subjects were included in the study. The typical subject was 60 years of age or older, female, overweight, and hypertensive, and demonstrated low socioeconomic status. The sensitivity and specificity of ECG for left ventricular hypertrophy in the overall cohort were 30.7% and 84.4%, respectively, with multiple patient characteristics influencing these results. CONCLUSIONS: This is the first study to confirm the sensitivity and specificity of ECG for left ventricular hypertrophy in a large, diverse patient population with significant minority representation. Furthermore, although these statistical measures are influenced by patient characteristics, such differences are likely not clinically significant.


Subject(s)
Electrocardiography , Hypertrophy, Left Ventricular/diagnosis , Adolescent , Adult , Aged , Aged, 80 and over , Echocardiography , Female , Humans , Male , Middle Aged , Retrospective Studies , Sensitivity and Specificity , Young Adult
15.
Sleep Med ; 69: 155-158, 2020 05.
Article in English | MEDLINE | ID: mdl-32088351

ABSTRACT

BACKGROUND: Daylight saving time (DST) imposes a twice-yearly hour shift. The transitions to and from DST are associated with decreases in sleep quality and environmental hazards. Detrimental health effects include increased incidence of acute myocardial infarction (MI) following the springtime transition and increased ischemic stroke following both DST transitions. Conditions effecting sleep are known to provoke atrial fibrillation (AF), however the effect of DST transitions on AF are unknown. METHODS: Admitted patients aged 18-100 with primary ICD9 code of AF between 2009 and 2016 were included. The number of admissions was compiled and means were compared for the Monday to Thursday period and the entire seven day interval following each DST transition and the entire year for the entire cohort and separated by gender. Significance was determined with Wilcoxon nonparametric tests. RESULTS: Admission data for 6089 patients were included, with mean age of 68 years and 53% female. A significant increase was found in mean AF admissions over the Monday to Thursday period (3.09 vs 2.47 admissions/day [adm/d], P = 0.017) and entire week (2.48 vs 2.09 adm/d, P = 0.025) following the DST spring transition compared to the yearly mean. When separated by gender, women exhibited an increase in AF admissions following the DST spring transition (1.78 vs 1.28 adm/d for Monday to Thursday period, P = 0.036 and 1.38 vs 1.11 adm/d for entire week, P = 0.050) while a non-significant increase was seen in men. No significant differences were found following the autumn transition for the entire cohort or when separated by gender. CONCLUSION: An increase in AF hospital admissions was found following the DST springtime transition. When separated by gender, this finding persisted only among women. This finding adds to evidence of negative health effects associated with DST transitions and factors that contribute to AF episodes.


Subject(s)
Atrial Fibrillation/complications , Circadian Rhythm , Hospitalization , Patient Admission/statistics & numerical data , Photoperiod , Aged , Female , Humans , Incidence , Male , Myocardial Infarction/epidemiology , Retrospective Studies , Sex Factors , Sleep/physiology , Stroke/epidemiology , Surveys and Questionnaires , Time Factors , United States/epidemiology
16.
J Interv Card Electrophysiol ; 57(1): 5-26, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31828560

ABSTRACT

Premature ventricular complexes (PVCs) are common arrhythmias in the clinical setting. PVCs in the structurally normal heart are usually benign, but in the presence of structural heart disease (SHD), they may indicate increased risk of sudden death. High PVC burden may induce cardiomyopathy and left ventricular (LV) dysfunction or worsen underlying cardiomyopathy. Sometimes PVCs may be a marker of underlying pathophysiologic process such as myocarditis. Identification of PVC burden is important, since cardiomyopathy and LV dysfunction can reverse after catheter ablation or pharmacological suppression. This state-of-the-art review discusses pathophysiology, clinical manifestations, how to differentiate benign and malignant PVCs, PVCs in the structurally normal heart, underlying SHD, diagnostic procedures (physical examination, electrocardiogram, ambulatory monitoring, exercise testing, echocardiography, cardiac magnetic resonance imaging, coronary angiography, electrophysiology study), and treatment (lifestyle modification, electrolyte imbalance, medical, and catheter ablation).


Subject(s)
Ventricular Premature Complexes/diagnosis , Ventricular Premature Complexes/therapy , Diagnosis, Differential , Humans , Ventricular Premature Complexes/physiopathology
17.
J Am Coll Cardiol ; 74(11): 1505-1511, 2019 09 17.
Article in English | MEDLINE | ID: mdl-31514954

ABSTRACT

Until 2019, guidelines for procedural sedation emphasized a detailed process most applicable for elective procedures scheduled well in advance. These guidelines provided by the American Society of Anesthesiologists were adopted by many specialties and institutions, and they have historically served the medical field well. However, cardiologists and other specialists often encounter urgent situations that demand unscheduled sedation. Physicians have been concerned about performing procedures in a fashion that "departs from the guidelines." In response, the American College of Emergency Physicians (ACEP) has developed a set of guidelines for patients requiring urgent unscheduled sedation. Many of the recommendations made within the novel ACEP guidelines are appropriate for cardiology, but there remain fundamental differences between trauma and other emergencies encountered in the emergency department and urgent cardiac procedures. This paper examines the differences between the American Society of Anesthesiologists and ACEP guidelines and provides some points to consider regarding best practices for cardiologists.


Subject(s)
Conscious Sedation/standards , Deep Sedation/standards , Emergency Treatment/standards , Heart Diseases/therapy , Practice Guidelines as Topic , Cardiology/standards , Humans
18.
Ann Emerg Med ; 73(5): e51-e65, 2019 05.
Article in English | MEDLINE | ID: mdl-31029297

ABSTRACT

The American College of Emergency Physicians (ACEP) organized a multidisciplinary effort to create a clinical practice guideline specific to unscheduled, time-sensitive procedural sedation, which differs in important ways from scheduled, elective procedural sedation. The purpose of this guideline is to serve as a resource for practitioners who perform unscheduled procedural sedation regardless of location or patient age. This document outlines the underlying background and rationale, and issues relating to staffing, practice, and quality improvement.


Subject(s)
Conscious Sedation/standards , Consensus , Humans , Practice Guidelines as Topic , Societies, Medical
20.
J Interv Card Electrophysiol ; 52(3): 281-285, 2018 Aug.
Article in English | MEDLINE | ID: mdl-30128802

ABSTRACT

The His bundle divides into the right bundle branch (RBB) and the more complex left bundle branch (LBB). The latter is typically represented as further dividing into anterior and posterior fascicles, and possibly an additional septal fascicle. This construct raises questions as to why conduction can be preserved in patients with "trifascicular block" and why it sometimes very difficult to ablate fascicular or papillary muscle tachycardias. The answer may be that the LBB is much more complex, variable, and interconnected and that the simple familiar constructs may have obstructed our understanding of conduction and tachycardias. Remarkably, the actual explanatory histopathology has been known for nearly half a century, spearheaded by the work of Demoulin and Kulbertus. One picture is worth a thousand words.


Subject(s)
Bundle of His/surgery , Bundle-Branch Block/diagnostic imaging , Bundle-Branch Block/surgery , Catheter Ablation/methods , Heart Conduction System/physiopathology , Bundle of His/physiopathology , Electrocardiography/methods , Female , Follow-Up Studies , Humans , Male , Papillary Muscles/physiopathology , Risk Assessment , Tachycardia/diagnostic imaging , Tachycardia/surgery , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...