Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 99
Filter
1.
J Pediatr Orthop ; 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-38987900

ABSTRACT

BACKGROUND: Neuromuscular early-onset scoliosis (N-EOS) often presents with a long sweeping thoracolumbar scoliosis and pelvic obliquity. With severe pelvic obliquity, the ribs come into contact with the high side of the pelvis, termed rib-on-pelvis deformity (ROP). The goal of this study is to evaluate whether ROP is associated with reported pain and other health-related quality of life (HRQOL) measures. We hypothesize that ROP is associated with increased pain and negative HRQOL. METHODS: A multicenter international registry was queried for all nonambulatory patients with N-EOS from 2012 to 2022. Both surgical and nonsurgical patients were included. ROP was classified as a binary radiographic assessment of preoperative (surgical patients) and most recent follow-up (nonsurgical patients) upright radiographs. Reported pain and other HRQOL measures were assessed through the 24-Item Early Onset Scoliosis Questionnaire (EOSQ-24). Patients with nonupright radiographs or EOSQ-24 questionnaires and corresponding radiographs >4 months apart were excluded. RESULTS: Totally, 225 patients (8.4±3.1 y, 55% female) were included. The median major curve was 63.3 (IQR: 40.6 to 81.2) degrees and median pelvic obliquity was 15.5 degrees (IQR: 8.8 to 26.4). Eighty-three patients (37%) had ROP. ROP was associated with both frequency (P<0.001) and severity (P<0.001) of pain. ROP was associated with worse general health (P=0.01), increased difficulty with vocalization (P=0.02), increased frequency of shortness of breath (P=0.002), and increased difficulty sitting upright (P=0.04). Regarding overall EOSQ-24 domains, ROP was associated with worse general health, pain/discomfort, pulmonary function, and physical function (P<0.01). In a subanalysis of 76 patients who underwent surgical intervention with at least 2 years of follow-up, patients with preoperative ROP experienced significantly greater improvements in both frequency (P=0.004) and severity (P=0.001) of pain than the patients without preoperative ROP at 2 years postoperatively. CONCLUSIONS: The overall incidence of ROP in N-EOS is about 37%. ROP is associated with greater pain and worse HRQOL through the EOSQ-24 questionnaire. Furthermore, these patients experienced a greater reduction in pain after surgery. Clinicians and parents must be aware that ROP is possibly a pain generator, but responds positively to surgical intervention. LEVEL OF EVIDENCE: Level III.

2.
Cognition ; 251: 105877, 2024 Jul 12.
Article in English | MEDLINE | ID: mdl-39002429

ABSTRACT

When presented with a lineup, the witness is tasked with identifying the culprit or indicating that the culprit is not present. The witness then qualifies the decision with a confidence judgment. But how do witnesses go about making these decisions and judgments? According to absolute-judgment models, witnesses determine which lineup member provides the strongest match to memory and base their identification decision and confidence judgment on the absolute strength of this MAX lineup member. Conversely, relative-judgment models propose that witnesses determine which lineup member provides the strongest match to memory and then base their identification decision and confidence judgment on the relative strength of the MAX lineup member compared to the remaining lineup members. We took a critical test approach to test the predictions of both models. As predicted by the absolute-judgment model, but contrary to the predictions of the relative-judgment model, witnesses were more likely to correctly reject low-similarity lineups than high-similarity lineups (Experiment 1), and more likely to reject biased lineups than fair lineups (Experiment 2). Likewise, witnesses rejected low-similarity lineups with greater confidence than high-similarity lineups (Experiment 1) and rejected biased lineups with greater confidence than fair lineups (Experiment 2). Only a single pattern was consistent with the relative model and inconsistent with the absolute model: suspect identifications from biased lineups were made with greater confidence than suspect identifications from fair lineups (Experiment 2). The results suggest that absolute-judgment models better predict witness decision-making than do relative-judgment models and that pure relative-judgment models are unviable.

3.
Article in English | MEDLINE | ID: mdl-38857373

ABSTRACT

STUDY DESIGN: Modified Delphi consensus study. OBJECTIVE: To develop consensus-based best practices for the care of pediatric patients who have implanted programmable devices (IPDs) and require spinal deformity surgery. SUMMARY OF BACKGROUND DATA: Implanted programmable devices (IPDs) are often present in patients with neuromuscular or syndromic scoliosis who require spine surgery. Guidelines for monitoring and interrogating these devices during the peri-operative period are not available. METHODS: A panel was assembled consisting of 25 experts (i.e., spinal deformity surgeons, neurosurgeons, neuro-electrophysiologists, cardiologists, and otolaryngologists). Initial postulates were based on literature review and results from a prior survey. Postulates addressed the following IPDs: vagal nerve stimulators (VNS), programmable ventriculo-peritoneal shunts (VPS), intrathecal baclofen pumps (ITBP), cardiac pacemakers and implantable cardioverter-defibrillators (ICD), deep brain stimulators (DBS), and cochlear implants. Cardiologist and otolaryngologists participants responded only to postulates on cardiac pacemakers or cochlear implants, respectively. Consensus was defined as ≥80% agreement, items that did not reach consensus were revised and included in subsequent rounds. A total of three survey rounds and one virtual meeting were conducted. RESULTS: Consensus was reached on 39 total postulates across six IPD types. Postulates addressed general spine surgery considerations, use of intraoperative monitoring and cautery, use of magnetically-controlled growing rods (MCGRs), and use of an external remote controller to lengthen MCGRs. Across IPD types, consensus for the final postulates ranged from 94.4-100%. Overall, experts agreed that MCGRs can be surgically inserted and lengthened in patients with a variety of IPDs and provided guidance for the use of intraoperative monitoring and cautery, which varied between IPD types. CONCLUSION: Spinal deformity correction surgery often benefits from the use of intraoperative monitoring, monopolar and bipolar cautery, and MCGRs. Final postulates from this study can inform the peri- and post-operative practices of spinal deformity surgeons who treat patients with both scoliosis and IPDs. LEVEL OF EVIDENCE: V- Expert opinion.

4.
Spine Deform ; 2024 May 08.
Article in English | MEDLINE | ID: mdl-38717696

ABSTRACT

PURPOSE: The "law of diminishing returns" (LODR) in early-onset scoliosis (EOS) is well-known. We hypothesized that previously observed variations between constructs may be related to the lateral distance that each construct lies from the spine. We therefore sought to determine whether the curve magnitude improvement and spinal length gains for distraction-based constructs in EOS are positively correlated with the collinearity of the spine and the convex-sided implant on posteroanterior radiographs. METHODS: A prospectively-collected, multicenter EOS registry was queried for all patients who underwent non-fusion, distraction-based instrumentation surgery. Post-index radiographs were graded from 1 to 5 based on amount of overlap between the convex-sided rod and the apical vertebra. Grade 1: convex rod is lateral to convex-sided pedicle; Grade 2: overlaps the convex-sided pedicle; Grade 3: lies between pedicles; Grade 4: overlaps concave-sided pedicle; Grade 5: medial to concave-sided pedicle. ANOVA assessed the correlations between post-index overlap grade and change in (a) curve magnitude and (b) T1-T12 height. Multivariable regression modeling further assessed these associations. RESULTS: 284 patients met all selection criteria and were included. On ANOVA, post-index grade was associated with curve magnitude (p <0.001) and T1-12 height (p = 0.028) change. Better curve correction and height change were associated with higher grade. On regression modeling, curve correction (R = 0.574) and T1-T12 height change (R = 0.339) remained significantly associated with grade when controlling for time, anchor locations, age, underlying diagnosis, and pre-index curve magnitude. CONCLUSION: More apical overlap by the convex rod was associated with better spinal deformity control and improved height gain. LEVEL OF EVIDENCE III: Therapeutic.

5.
Appl Radiat Isot ; 209: 111326, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38701595

ABSTRACT

Thorium-227 was separated from its progeny and standardized for activity by the triple-to-double coincidence ratio (TDCR) method of liquid scintillation counting. Confirmatory liquid scintillation-based measurements were made using efficiency tracing with 3H and live-timed anticoincidence counting (LTAC). The separation time and the efficiency of the separation were confirmed by gamma-ray spectrometry. Calibrations for reentrant pressurized ionization chambers, including commercial radionuclide calibrators, and a well-type NaI(Tl) detector are discussed.

6.
Appl Radiat Isot ; 203: 111108, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38000166

ABSTRACT

Gadolinium-153 was standardized for activity by live-timed anticoincidence counting and an ampoule was submitted to the international reference system (SIR). Absolute emission intensities for the main γ rays were determined with calibrated high-purity germanium (HPGe) and lithium-drifted silicon (Si(Li)) detectors. A revised decay scheme is indicated, with no probability of direct electron capture to the 153Eu ground state. Triple-to-double coincidence ratio (TDCR) efficiency curves indicate that the revised decay scheme is consistent with experiment. Half-life measurements agree with a previous NIST determination and show no sensitivity to chemical environment.

7.
Appl Radiat Isot ; 202: 111068, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37866226

ABSTRACT

The Vinten 671 ionization chamber (VIC) was modelled using Monte Carlo (MC) programs EGSnrc, Penelope, and TOPAS. Several national measurement institutes have VICs with well-characterized response relationships and have measured calibration coefficients for many radionuclides. Twelve radionuclides with various decay emissions were assessed as well as 14 monoenergetic photon sources and 10 monoenergetic electron sources. Calibration coefficients were calculated based on the energy deposited in the simulated VIC nitrogen gas volume and compared to experimental values from the literature.

8.
Appl Radiat Isot ; 201: 111025, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37717417

ABSTRACT

A manual microliter gravimetric dispensing technique is demonstrated using a micropipettor modified for use with removeable microcapillaries. Liquid scintillation sources were prepared from a well-characterized 241Am reference solution, providing a radiometric check of dispensed masses. Further experiments confirmed controlled dispensing of drops onto gold foils with losses ≤0.34(4) % of the total drop activity. A detailed measurement equation for the weighing technique, including the corrections for evaporation, is presented with a full accounting of associated uncertainties.

9.
Memory ; 31(9): 1218-1231, 2023 10.
Article in English | MEDLINE | ID: mdl-37646087

ABSTRACT

Border control officers may be on the lookout for wanted people while they verify that travellers match their passport photos. We developed a novel experimental paradigm to investigate whether people are more likely to report that someone is wanted if they also believe that person is using a fraudulent passport. In two experiments, undergraduate students assumed the role of a border control officer and completed multiple "shifts" of a face matching task designed to simulate a passport verification check. Before each shift participants viewed posters of wanted people and were instructed to report any sightings if a wanted person appeared in any of the images during the passport check. Participants were more likely to say an individual was wanted if they also believed the person did not match their passport image. In addition, the accuracy of wanted person sightings was reduced for trials with nonmatching passports compared to trials with matching passports. This suggests wanted people with matching passports were easier to spot because participants had an additional image to compare with their memory of the person in the wanted poster.


Subject(s)
Memory, Episodic , Humans , Prospective Studies , Students
10.
Law Hum Behav ; 47(4): 463-483, 2023 08.
Article in English | MEDLINE | ID: mdl-37471013

ABSTRACT

OBJECTIVE: The risk of mistaken identification for innocent suspects in lineups can be estimated by correcting the overall error rate by the number of people in the lineup. We compared this nominal size correction to a new effective size correction, which adjusts the error rate for the number of plausible lineup members. HYPOTHESES: We hypothesized that (a) increasing lineup bias would increase misidentifications of a designated innocent suspect; (b) with the effective size correction, increasing lineup bias would also increase the estimate of innocent-suspect misidentifications; and (c) with the nominal size correction, lineup bias would have no effect on the estimate of innocent-suspect misidentifications. METHOD: In a reanalysis of previous literature, we obtained 10 data sets from Open Science Framework. In three new experiments (Ns = 686, 405, and 1,531, respectively), participants observed a staged crime and completed a fair or biased lineup. RESULTS: In the reanalysis of previous literature, less than four of six lineup members were identified frequently enough to be classified as plausible, M = 3.78, 95% confidence interval [CI: 2.20, 5.36]. In the new experiments, increasing lineup bias increased mistaken identifications of a designated innocent suspect, odds ratio (OR) = 5.50, 95% CI [2.77, 10.95] and also increased the effective size-corrected estimate of innocent-suspect misidentifications, OR = 3.04, 95% CI [2.13, 4.33]. With the nominal size correction, lineup bias had no effect on the estimate of innocent-suspect misidentifications, OR = 0.84, 95% CI [0.60, 1.18]. CONCLUSIONS: Most lineups include a combination of plausible and implausible lineup members. Contrary to the nominal size correction, which ignores implausible lineup members, the effective size correction is sensitive to implausible lineup members and accounts for lineup bias when estimating the risk of innocent suspect misidentifications. (PsycInfo Database Record (c) 2023 APA, all rights reserved).


Subject(s)
Mental Recall , Recognition, Psychology , Humans , Criminal Law/methods , Crime
11.
Appl Radiat Isot ; 200: 110945, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37515859

ABSTRACT

The Bureau International des Poids et Mesures (BIPM) is developing a new transfer instrument to extend its centralized services for assessing the international equivalence of radioactive standards to new radionuclides. A liquid scintillation counter using the triple/double coincidence ratio method is being studied and tested in the CCRI(II)-P1.Co-60 pilot study. The pilot study, involving 13 participating laboratories with primary calibration capabilities, validated the approach against the original international reference system based on ionization chambers, which has been in operation since 1976. The results are in agreement and an accuracy suitable for purpose, below 5×10-4, is achieved. The pilot study also reveals an issue when impurities emitting low-energy electrons are present in the standard solution, which have a different impact on liquid scintillation counting compared to other primary measurement methods.

12.
Spine Deform ; 11(6): 1517-1527, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37450222

ABSTRACT

PURPOSE: The Law Of Diminishing Returns (LODR) has been demonstrated for traditional growing rods, but there is conflicting data regarding the lengthening behavior of Magnetically Controlled Growing Rods (MCGR). This study examines a cohort of patients with early-onset scoliosis (EOS) with rib-to-spine or rib-to-pelvis-based MCGR implants to determine if they demonstrate the LODR, and if there are differences in lengthening behaviors between the groups. METHODS: A prospectively collected multicenter EOS registry was queried for patients with MCGR with a minimum 2-year follow-up. Patients with rib-based proximal anchors and either spine- or pelvis-based distal anchors were included. Patients with non-MCGR, unilateral constructs, < 3 lengthenings, or missing > 25% datapoints were excluded. Patients were further divided into Primary-MCGR (pMCGR) and Secondary-MCGR (sMCGR). RESULTS: 43 rib-to-spine and 31 rib-to-pelvis MCGR patients were included. There was no difference in pre-implantation, post-implantation and pre-definitive procedure T1-T12 height, T1-S1 height, and major Cobb angles between the groups (p > 0.05). Sub-analysis was performed on 41 pMCGR and 19 sMCGR rib-to-spine patients, and 31 pMCGR and 17 sMCGR rib-to-pelvis patients. There is a decrease in rod lengthenings achieved at subsequent lengthenings for each group: rib-to-spine pMCGR (rho = 0.979, p < 0.001), rib-to-spine sMCGR (rho = 0.855, p = 0.002), rib-to-pelvis pMCGR (rho = 0.568, p = 0.027), and rib-to-pelvis sMCGR (rho = 0.817, p = 0.007). Rib-to-spine pMCGR had diminished lengthening over time for idiopathic, neuromuscular, and syndromic patients (p < 0.05), with no differences between the groups (p > 0.05). Rib-to-pelvis pMCGR neuromuscular patients had decreased lengthening over time (p = 0.01), but syndromic patients had preserved lengthening over time (p = 0.65). CONCLUSION: Rib-to-spine and rib-to-pelvis pMCGR and sMCGR demonstrate diminished ability to lengthen over subsequent lengthenings.

13.
J Pediatr Orthop B ; 32(1): 8-14, 2023 Jan 01.
Article in English | MEDLINE | ID: mdl-35635534

ABSTRACT

Talipes equinovarus (TEV) can be an isolated idiopathic deformity or associated with various syndromes. The purpose of our study was to examine the demographics of TEV in Indiana. All TEV patients from 2010 to 2019 from our institution were reviewed, recording standard demographic variables. The socioeconomic level of the family was determined using the 2018 Area Deprivation Index (ADI). There were 568 patients; 456 had idiopathic TEV and 112 syndromic. Within the idiopathic group, 69.1% were male, 92.1% were typical and 7.9% were atypical. Medical issues during the pregnancy occurred in 19.5%, maternal smoking in 2.9%, hypertension in 3.9% and diabetes in 5.3%. The most common syndromic patients were myelomeningocele (29%) and arthrogryposis (17%). Patients with syndromic TEV had more bilateral involvement (68.2% vs. 45.2%) and other associated congenital deformities (67.0% vs. 11.4%). TEV was less common in Hispanics and Asians but more common in Whites and Blacks ( P = 0.003). Complex TEVs were less frequent in White (6.9%) and Black (5.0%) and more common in Hispanic (30%) children ( P = 0.0002). The ADI demonstrated no difference in prevalence across socioeconomic levels. There were no differences by state ADI levels for TEV type (syndromic/idiopathic), sex, maternal smoking or illicit drug use, or typical/complex TEV. This study is the first to describe the demographics of TEV in Indiana, demographic differences between typical and complex types of clubfeet, and TEV patients using the ADI. TEV did not show any difference in prevalence by socioeconomic level.


Subject(s)
Clubfoot , Family , Child , Female , Humans , Male
14.
Spine Deform ; 11(1): 115-121, 2023 01.
Article in English | MEDLINE | ID: mdl-35997944

ABSTRACT

PURPOSE: To assess the reliability of vertebral height and angular measurements for anterior vertebral body tethering (AVBT). METHODS: Eight observers measured PA radiographs of 15 idiopathic scoliosis patients treated with AVBT, pre-operative and 4-year follow-up. Vertebral wedging, disc wedging, convex vertebral body heights, and concave vertebral body heights of the 3 apical vertebrae were measured. For each observer, there were a total of 90 measurements for vertebral body height and 75 measurements for all wedging types At least 14 days elapsed between first and second round measurements. RESULTS: From the pre-operative to the 4-year follow-up time-point, the total wedging angle over the 3 peri-apical levels fell from 30 ± 7° to 16 ± 6° (p < 0.001) and the difference between the convex and concave vertebral heights decreased from 9 ± 4 to 6 ± 3 mm (p < 0.001). Interobserver agreement for pre-operative vertebral body heights was good [ICC = 0.80; 95% CI (0.74-0.85)]. At 4-year follow-up there was a moderate agreement [ICC = 0.67 (0.59-0.74)]. There was a poor interobserver agreement for pre-operative wedging angle measurements [ICC = 0.41 (0.32-0.52)] and 4-year follow-up [ICC = 0.45 (0.36-0.56)]. The Limits of Agreement with the Mean (LOAM) for pre-op heights was ± 2.4 mm, similar to the follow-up ± 2.6 mm. When raters are averaged in random groups of two the agreement limits decrease to ± 1.8 mm pre-op and ± 1.6 mm at follow-up. Similarly for wedging angles, LOAM values among the 8 observers of ± 4.6° pre-op and ± 4.2° dropped to ± 2.7° for both pre-op and follow-up when random groups of two raters were averaged together. Intraobserver agreement ranged from good to excellent per individual (ICC = 0.84-0.94) for pre-operative vertebral body heights, but this decreased at 4-year follow-up (ICC = 0.52-0.88). Intraobserver agreement was low overall for wedging (pre-operative ICC = 0.41-0.71; 4-year follow-up ICC = 0.41-0.76). CONCLUSION: Based on 8 individual observers, interobserver agreement ranged from good (pre-operative vertebral body heights) to moderate (4-year follow-up vertebral body heights) to poor (all wedging angles). To improve the reliability of the measurement of wedging angles, we recommend averaging the measurements of at least two observers.


Subject(s)
Scoliosis , Humans , Child , Scoliosis/diagnostic imaging , Scoliosis/surgery , Thoracic Vertebrae/diagnostic imaging , Thoracic Vertebrae/surgery , Vertebral Body , Reproducibility of Results , Radiography
15.
Appl Radiat Isot ; 190: 110473, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36201936

ABSTRACT

An activity standard for 212Pb in equilibrium with its progeny was realized, based on triple-to-double coincidence ratio (TDCR) liquid scintillation (LS) counting. A Monte Carlo-based approach to estimating uncertainties due to nuclear decay data (branching ratios, beta endpoint energies, γ-ray energies, and conversion coefficients for 212Pb and 208Tl) led to combined standard uncertainties ≤ 0.20 %. Confirmatory primary measurements were made by LS efficiency tracing with tritium and 4παß(LS)-γ(NaI(Tl)) anticoincidence counting. The standard is discussed in relation to current approaches to 212Pb activity calibration. In particular, potential biases encountered when using inappropriate radionuclide calibrator settings are discussed.


Subject(s)
Lead , Scintillation Counting , Scintillation Counting/methods , Radioisotopes , Tritium/analysis , Reference Standards
16.
Foot Ankle Orthop ; 7(3): 24730114221119180, 2022 Jul.
Article in English | MEDLINE | ID: mdl-36046551

ABSTRACT

Background: The Ponseti method is today's standard treatment of idiopathic talipes equinovarus (ITEV). Compliance with foot abduction bracing (FABO) and socioeconomic factors have been shown to impact treatment outcome. We wished to further study socioeconomic factors using the Area Deprivation Index (ADI), a more comprehensive way to evaluate socioeconomic status, which has not been done before. Methods: All TEV patients from 2010 through 2019 treated with the Ponseti method were reviewed. Standard demographic variables, as well as the number of casts to complete initial correction, FABO compliance, and occurrence of relapse were tabulated. Socioeconomic level was quantified with the 2018 ADI. Results: There were 168 children; 151 had typical and 17 complex TEV. Average follow-up was 4.3 ± 1.8 years; relapse occurred in 46%. There were no significant differences in the percentage of relapse by sex, race, or ADI. FABO noncompliance was present in 46%. Relapse increased with increasing time of follow-up and FABO noncompliance (76% vs 21%, P < 10-6). Multivariate logistic regression analysis revealed that only FABO compliance and length of follow-up were associated with relapse. The OR of relapse for FABO noncompliance was 17.9 (7.6, 42.4, P < 10-6) and for follow-up >4 years the OR was 4.97 (2.1, 11.70, P = .0003). Conclusion: The outcome of the Ponseti method for TEV treatment is dependent on local circumstances. In our state, socioeconomic status, as determined by the ADI, was not associated with the occurrence of relapse. Thus, each center needs to assess its results, and analyze its own reasons for relapse. There were no other demographic variables associated with relapse except FABO compliance and length of follow-up. Parents should be strongly advised that FABO compliance and follow-up appears paramount to achieving the best results, and that complex TEV are at greater risk for relapse. Level of Evidence: Level IV, case series.

17.
Article in English | MEDLINE | ID: mdl-35551145

ABSTRACT

INTRODUCTION: Early-onset scoliosis (EOS) is a well-known orthopaedic manifestation in patients with myelomeningocele. The rib-based growing system (RBGS) has been proposed as an alternative for these individuals because of the poor outcomes with traditional surgical techniques. We aimed to describe the effect of RBGS in patients with nonambulatory EOS myelomeningocele. METHODS: We retrospectively reviewed the Pediatric Spine Study Group Multicenter Database for all patients with nonambulatory EOS myelomeningocele treated with RBGS from 2004 to 2019. Demographics, surgical data, radiographic findings, and postoperative complications were obtained. The quality-of-life parameters were assessed postoperatively using the Early-onset Scoliosis Questionnaire-24. RESULTS: Thirty patients (18 women; 60%) were patients with nonambulatory EOS myelomeningocele treated with RBGS. The mean age at the initial surgery was 5.3 years. The thoracic (T1-T12) spine height showed a significant increase from initial surgery to the most recent follow-up (P < 0.001). Spine (T1-S1) height was also significantly increased (P < 0.001). The postoperative complication rate was 87%. The Early-onset Scoliosis Questionnaire-24 demonstrates significant improvements in the quality-of-life scores (P = 0.037). CONCLUSION: This study demonstrated that RBGS could improve the reported quality-of-life scores in patients with nonambulatory EOS myelomeningocele when assessed with an EOS-oriented tool. Moreover, we confirmed the ability of RBGS to hold or even correct spinal deformity.


Subject(s)
Meningomyelocele , Scoliosis , Child , Female , Follow-Up Studies , Humans , Meningomyelocele/complications , Meningomyelocele/surgery , Pelvis , Postoperative Complications/etiology , Retrospective Studies , Ribs/surgery , Scoliosis/etiology , Scoliosis/surgery , Treatment Outcome
18.
Sci Adv ; 8(20): eabm8954, 2022 May 20.
Article in English | MEDLINE | ID: mdl-35594349

ABSTRACT

Historically, the prevalence of child growth failure (CGF) has been tracked dichotomously as the proportion of children more than 2 SDs below the median of the World Health Organization growth standards. However, this conventional "thresholding" approach fails to recognize child growth as a spectrum and obscures trends in populations with the highest rates of CGF. Our analysis presents the first ever estimates of entire distributions of HAZ, WHZ, and WAZ for each of 204 countries and territories from 1990 to 2020 for children less than 5 years old by age group and sex. This approach reflects the continuous nature of CGF, allows us to more comprehensively assess shrinking or widening disparities over time, and reveals otherwise hidden trends that disproportionately affect the most vulnerable populations.

19.
J Pediatr Orthop ; 42(5): e409-e413, 2022.
Article in English | MEDLINE | ID: mdl-35200217

ABSTRACT

BACKGROUND: The Pavlik harness (PH) is commonly used to treat infantile dislocated hips. However, significant variability exists in the duration of brace treatment after successful reduction of the dislocated hip. The purpose of this study was to evaluate the effect of prescribed time in brace on acetabular index (AI) at two years of age using a prospective, international, multicenter database. METHODS: We retrospectively studied prospectively enrolled infants with at least 1 dislocated hip that were initially treated with a PH and had a recorded AI at 2-year follow-up. Subjects were treated at 1 of 2 institutions. Institution 1 used the PH until they observed normal radiographic acetabular development. Institution 2 followed a structured shorter brace treatment protocol. Hip dislocation was defined as <30% femoral head coverage at rest on the pretreatment ultrasound or International Hip Dysplasia Institute (IHDI) grade III or IV on the pretreatment radiograph. RESULTS: Fifty-three hips met our inclusion criteria. Hips from Institution 1 were treated with a brace ×3 longer than hips from institution 2 (adjusted mean 8.9±1.3 vs. 2.6±0.2 mo) (P<0.001). Institution 1 had an 88% success rate and institution 2 had an 85% success rate at achieving hip reduction (P=0.735). At 2-year follow-up, we observed no significant difference in AI between Institution 1 (adjusted mean 25.6±0.9 degrees) compared with Institution 2 (adjusted mean 23.5±0.8 degrees) (P=0.1). However, 19% of patients from Institution 1 and 44% of patients from Institution 2 were at or below the 50th percentile of previously published age-matched and sex-matched AI normal data (P=0.049). Also, 27% (7/26) of hips from Institution 1 had significant acetabular dysplasia (more than 2 SD from the mean), compared with a 22% (6/27) from Institution 2 (P=0.691). We found no correlation between age at initiation of bracing and AI at 2-year follow-up (P=0.071). CONCLUSIONS: The PH brace can successfully treat dislocated infant hips, however, prolonged brace treatment was not found to result in improved acetabular development at 2-year follow-up. LEVEL OF EVIDENCE: Level III.


Subject(s)
Hip Dislocation, Congenital , Hip Dislocation , Acetabulum/diagnostic imaging , Hip Dislocation, Congenital/diagnostic imaging , Hip Dislocation, Congenital/therapy , Humans , Infant , Orthotic Devices , Prospective Studies , Retrospective Studies , Time Factors , Treatment Outcome
20.
Spine Deform ; 10(4): 951-964, 2022 07.
Article in English | MEDLINE | ID: mdl-35143030

ABSTRACT

PURPOSE: Operative and postoperative management of early onset scoliosis (EOS) patients with programmable implanted devices has not been well characterized in the literature. The aim of this study was to describe current practices for pediatric spine surgeons who operate on patients with these devices. METHODS: An electronic survey was distributed to 167 pediatric spine surgeons between January and March of 2021. The survey queried participants on operative and postoperative management of patients with the following implanted devices: vagal nerve stimulators, ventriculoperitoneal shunts, intrathecal baclofen pumps, pacemakers, and cochlear implants. Descriptive statistics were used to assess survey data. RESULTS: Fifty-three respondents (31.7% response rate) with a mean 16.5 (SD 12.0) years in practice completed the survey. Depending on the type of device present, surgeons report changing their operative plan anywhere from 28.6 to 60.1% of the time when inserting magnetically controlled growing rods. Most respondents reported performing transcranial motor evoked potentials (80.0-98.0%) and monopolar cautery (70.0-92.9%) across implanted devices. Only 10% (n = 5) of surgeons reported complications related to operative and/or postoperative management of these patients. No complications were related to cautery, neuromonitoring, or surgical placement of MCGRs. CONCLUSIONS: This study demonstrates variation in operative and postoperative management of these patients with various programmable implanted devices. Much of this inconsistency in practice is likely due to decades old case reports, constantly changing device manufacturer recommendations, and/or published simulation studies. Reported heterogeneity in management across surgeons necessitates development of published guidelines regarding proper operative and postoperative management of patients with EOS and implanted devices.


Subject(s)
Scoliosis , Surgeons , Child , Humans , Prostheses and Implants , Scoliosis/surgery , Spine/surgery , Surveys and Questionnaires
SELECTION OF CITATIONS
SEARCH DETAIL