Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Perfusion ; 37(8): 819-824, 2022 11.
Article in English | MEDLINE | ID: mdl-34254557

ABSTRACT

INTRODUCTION: The Crescent® is a recently introduced dual lumen cannula by which veno-venous extracorporeal membrane oxygenation (VV ECMO) is delivered. It has a number of features that enhance its ease of placement, pressure-flow dynamics and may reduce catheter-related complication rates. METHODS: We present the first case series of its kind analysing this device by means of a retrospective observational study of prospectively collected data from the first year of its use in a high volume severe acute respiratory failure centre (Glenfield, UK). We compare complication rates of the Crescent®, with data from the international ELSO database and our own historic centre data and discuss subjective clinician experience of introducing this device. RESULTS: Over the first 12 months of its use (23/09/2019-23/09/2020), 54 patients were cannulated using a Crescent® catheter. There were no serious/life-threatening adverse events and a low number of minor cannula-related complications. Subjectively users found it has a number of advantages over other devices and configurations, not captured within current data collection frameworks. CONCLUSION: The Crescent® is a safe and effective device by which to deliver VV ECMO support to patients with severe acute respiratory failure.


Subject(s)
Extracorporeal Membrane Oxygenation , Respiratory Distress Syndrome , Respiratory Insufficiency , Adult , Humans , Extracorporeal Membrane Oxygenation/adverse effects , Cannula , Respiratory Distress Syndrome/therapy , Catheters , Respiratory Insufficiency/therapy , Respiratory Insufficiency/etiology
2.
J Med Case Rep ; 5: 259, 2011 Jun 30.
Article in English | MEDLINE | ID: mdl-21718493

ABSTRACT

INTRODUCTION: This case report describes a rare condition: community-acquired adenovirus pneumonia in an immunocompetent adult. The diagnosis was achieved by using a multiplex real-time reverse transcriptase polymerase chain reaction (RT-PCR) assay and highlights the usefulness of these novel molecular diagnostic techniques in patients hospitalized with acute respiratory illness. We also performed a literature search for previously published cases and present a summary of the clinical, laboratory and radiological features of this condition. CASE PRESENTATION: A 44-year-old immunocompetent Caucasian woman was admitted to our hospital with an acute febrile respiratory illness associated with a rash. Her blood tests were non-specifically abnormal, and tests for bacterial pathogens were negative. Her condition rapidly deteriorated while she was in our hospital and required mechanical ventilation and inotropic support. A multiplex real-time RT-PCR assay performed on respiratory specimens to detect respiratory viruses was negative for influenza but positive for adenovirus DNA. The patient recovered on supportive treatment, and antibiotics were stopped after 5 days. CONCLUSIONS: Community-acquired adenovirus pneumonia in immunocompetent adult civilians presents as a non-specific acute febrile respiratory illness followed by the abrupt onset of respiratory failure, often requiring mechanical ventilation. Its laboratory and radiological features are typical of viral infections but also are non-specific. Novel multiplex real-time RT-PCR testing for respiratory viruses enabled us to rapidly make the diagnosis in this case. The new technology could be used more widely in patients with acute respiratory illness and has potential utility for rationalization of the use of antibiotics and improving infection control measures.

SELECTION OF CITATIONS
SEARCH DETAIL
...