Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Eur Radiol ; 17(1): 49-60, 2007 Jan.
Article in English | MEDLINE | ID: mdl-16636801

ABSTRACT

PURPOSE: The purpose of this work was to evaluate the characteristic appearance of untreated retinoblastoma on a large sample in comparison to the histological findings after therapeutical enucleation. MATERIALS AND METHODS: In a prospective clinical trial 46 children with retinoblastoma in 63 affected untreated eyes were examined under general anesthesia on MRI using a 1.5-T system. The examinations were performed with a special surface coil applying an examination protocol including fast T2- and T1-weighted spin echo sequences and additional fast T1-WI after intravenous injection of Gd-DTPA in different planes. The imaging results were compared to the histopathological findings in 29 patients with 30 affected eyes. RESULTS: Comparing MRI findings and histopathological results, optic nerve infiltration was detected with a sensitivity of 53.8% and a specificity of 82.3% on MRI, infiltration of the choroid with a sensitivity of 75.0% and a specificity of 100.0%, and the degree of tumor calcification with a sensitivity of 91.7% and a specificity of 88.9%. In this study the characteristic MR appearance of untreated retinoblastoma was evaluated. CONCLUSION: MRI was helpful in relevant aspects of pretherapeutical retinoblastoma staging, deficits remain regarding optic nerve infiltration.


Subject(s)
Magnetic Resonance Imaging/instrumentation , Retinal Neoplasms/diagnosis , Retinoblastoma/diagnosis , Child , Child, Preschool , Female , Humans , Infant , Male , Prospective Studies , Retinal Neoplasms/pathology , Retinoblastoma/pathology
2.
Radiology ; 240(2): 552-8, 2006 Aug.
Article in English | MEDLINE | ID: mdl-16775220

ABSTRACT

The purpose of this study was to construct and evaluate a phantom for measurement of magnetic resonance (MR) imaging sections with thicknesses of 0.3-0.6 mm. The phantom consisted of 304 0.1-mm-thick disks, each of which had a single notch filled with a diluted solution of gadopentetate dimeglumine. Qualitative and quantitative evaluations of T1-weighted images with section thicknesses of 0.3-0.6 mm were performed. A computer simulation was performed to evaluate the influence of different examination angles. At quantitative evaluation, the difference between nominal and measured section thicknesses ranged from 11% (nominal section thickness, 0.6 mm) to 18% (nominal section thickness, 0.4 mm). Computer simulations revealed that the phantom's positioning along the z-axis had a negligible influence at quantitative evaluation.


Subject(s)
Magnetic Resonance Imaging , Phantoms, Imaging , Computer Simulation , Contrast Media , Equipment Design , Gadolinium DTPA , Statistics as Topic
SELECTION OF CITATIONS
SEARCH DETAIL
...