Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
1.
JAMA Cardiol ; 7(5): 513-520, 2022 05 01.
Article in English | MEDLINE | ID: mdl-35385057

ABSTRACT

Importance: Low-flow severe aortic stenosis (AS) has higher mortality than severe AS with normal flow. The conventional definition of low-flow AS is an indexed stroke volume (SVi) by echocardiography less than 35 mL/m2. Cardiovascular magnetic resonance (CMR) is the reference standard for quantifying left ventricular volumes and function from which SVi by CMR can be derived. Objective: To determine the association of left ventricular SVi by CMR with myocardial remodeling and survival among patients with severe AS after valve replacement. Design, Setting, and Participants: This multicenter longitudinal cohort study was conducted between January 2003 and May 2015 across 6 UK cardiothoracic centers. Patients with severe AS listed for either surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR) were included. Patients underwent preprocedural echocardiography and CMR. Patients were stratified by echocardiography-derived aortic valve mean and/or peak gradient and SVi by CMR into 4 AS endotypes: low-flow, low-gradient AS; low-flow, high-gradient AS; normal-flow, low-gradient AS; and normal-flow, high-gradient AS. Patients were observed for a median of 3.6 years. Data were analyzed from September to November 2021. Exposures: SAVR or TAVR. Main Outcomes and Measures: All-cause and cardiovascular (CV) mortality after aortic valve intervention. Results: Of 674 included patients, 425 (63.1%) were male, and the median (IQR) age was 75 (66-80) years. The median (IQR) aortic valve area index was 0.4 (0.3-0.4) cm2/m2. Patients with low-flow AS endotypes (low gradient and high gradient) had lower left ventricular ejection fraction, mass, and wall thickness and increased all-cause and CV mortality than patients with normal-flow AS (all-cause mortality: hazard ratio [HR], 2.08; 95% CI, 1.37-3.14; P < .001; CV mortality: HR, 3.06; 95% CI, 1.79-5.25; P < .001). CV mortality was independently associated with lower SVi (HR, 1.64; 95% CI, 1.08-2.50; P = .04), age (HR, 2.54; 95% CI, 1.29-5.01; P = .001), and higher quantity of late gadolinium enhancement (HR, 2.93; 95% CI, 1.68-5.09; P < .001). CV mortality hazard increased more rapidly in those with an SVI less than 45 mL/m2. SVi by CMR was independently associated with age, atrial fibrillation, focal scar (by late gadolinium enhancement), and parameters of cardiac remodeling (left ventricular mass and left atrial volume). Conclusions and Relevance: In this cohort study, SVi by CMR was associated with CV mortality after aortic valve replacement, independent of age, focal scar, and ejection fraction. The unique capability of CMR to quantify myocardial scar, combined with other prognostically important imaging biomarkers, such as SVi by CMR, may enable comprehensive stratification of postoperative risk in patients with severe symptomatic AS.


Subject(s)
Aortic Valve Stenosis , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Cicatrix/pathology , Cohort Studies , Contrast Media , Female , Fibrosis , Gadolinium , Humans , Longitudinal Studies , Magnetic Resonance Spectroscopy , Male , Stroke Volume , Ventricular Function, Left
3.
J Am Heart Assoc ; 9(1): e011521, 2020 01 07.
Article in English | MEDLINE | ID: mdl-31852424

ABSTRACT

Background Spironolactone may have prognostic benefit in selected patients with heart failure with preserved ejection fraction. This study assessed the myocardial tissue effects of spironolactone in heart failure with preserved ejection fraction. Methods and Results A 1:1 randomized controlled study of 6 months of spironolactone versus control in heart failure with preserved ejection fraction. The primary outcome was change in myocardial extracellular volume fraction by cardiovascular magnetic resonance as a surrogate of diffuse fibrosis. Of 55 randomized patients, 40 (20 women; age, 75.2±5.9 years) completed follow-up (19 treatment, 21 control). A significant change in extracellular volume over the study period was not seen (treatment, 28.7±3.7% versus 27.7±3.4% [P=0.14]; controls, 27.6±3.4% versus 28.3±4.4% [P=0.14]); however, the rate of extracellular volume expansion was decreased by spironolactone (-1.0±2.4% versus 0.8±2.2%). Indexed left ventricular mass decreased with treatment (104.4±26.6 versus 94.0±20.6 g/m2; P=0.001) but not in controls (101.4±29.4 versus 104.0±32.8 g/m2; P=0.111). Extracellular mass decreased by 13.8% (15.1±4.8 versus 13.0±3.4 g/m2; P=0.003), and cellular mass decreased by 8.3% (37.6±10.0 versus 34.3±7.9 g/m2; P=0.001) with spironolactone, but was static in controls. Conclusions Spironolactone did not lead to significant change in extracellular volume. However, spironolactone did decrease rate of extracellular expansion, with a decrease in the mass of both cellular and extracellular myocardial compartments. These data point to the mechanism of action of spironolactone in heart failure with preserved ejection fraction, including a direct tissue effect with a reduction in rate of myocardial fibrosis.


Subject(s)
Heart Failure/drug therapy , Mineralocorticoid Receptor Antagonists/therapeutic use , Myocardium/pathology , Spironolactone/therapeutic use , Stroke Volume/drug effects , Ventricular Function, Left/drug effects , Ventricular Remodeling/drug effects , Aged , Aged, 80 and over , England , Female , Fibrosis , Heart Failure/diagnostic imaging , Heart Failure/physiopathology , Humans , Magnetic Resonance Imaging, Cine , Male , Time Factors , Treatment Outcome
4.
BMJ Open ; 9(1): e022329, 2019 01 21.
Article in English | MEDLINE | ID: mdl-30670503

ABSTRACT

OBJECTIVE: To compare the incidence of silent cerebral infarction and impact on cognitive function following transcatheter aortic valve implantation (TAVI) with the first-generation CoreValve (Medtronic, Minneapolis, Minnesota, USA) and second-generation Lotus valve (Boston Scientific, Natick Massachusetts, USA). DESIGN: A prospective observational study comprising a 1.5 T cerebral MRI scan, performed preoperatively and immediately following TAVI, and neurocognitive assessments performed at baseline, 30 days and 1 year follow-up. SETTING: University hospitals of Leeds and Leicester, UK. PATIENTS: 66 (80.6±8.0 years, 47% male) patients with high-risk severe symptomatic aortic stenosis recruited between April 2012 and May 2015. MAIN OUTCOME MEASURES: Incidence of new cerebral microinfarction and objective decline in neurocognitive performance. RESULTS: All underwent cerebral MRI at baseline and immediately following TAVI, and 49 (25 Lotus, 24 CoreValve) completed neurocognitive assessments at baseline, 30 days and 1 year. There was a significantly greater incidence of new cerebral microinfarction observed following the Lotus TAVI (23 (79%) vs 22 (59%), p=0.025) with a greater number of new infarcts per patient (median 3.5 (IQR 7.0) vs 2.0 (IQR 3.0), p=0.002). The mean volume of infarcted cerebral tissue per patient was equivalent following the two prostheses (p=0.166). More patients suffered new anterior (14 (48%) vs 2 (5%), p=0.001) and vertebrobasilar (15 (52%) vs 7 (19%), p=0.005) lesions following Lotus. Lotus was associated with a decline in verbal memory and psychomotor speed at 30 days. However, performance longitudinally at 1 year was preserved in all neurocognitive domains. CONCLUSIONS: There was a higher incidence of silent cerebral microinfarction and a greater number of lesions per patient following Lotus compared with CoreValve. However, there was no objective decline in neurocognitive function discernible at 1 year following TAVI with either prosthesis.


Subject(s)
Aortic Valve Stenosis/surgery , Cerebral Infarction/physiopathology , Cognition , Heart Valve Prosthesis/classification , Transcatheter Aortic Valve Replacement/adverse effects , Aged , Aged, 80 and over , Cerebral Infarction/diagnostic imaging , Diffusion Magnetic Resonance Imaging , Female , Humans , Male , Mental Status and Dementia Tests , Prospective Studies , Prosthesis Design , Risk Factors , Severity of Illness Index , Time Factors , Treatment Outcome , United Kingdom
5.
J Magn Reson Imaging ; 49(5): 1437-1445, 2019 05.
Article in English | MEDLINE | ID: mdl-30597661

ABSTRACT

BACKGROUND: Late gadolinium enhancement (LGE) imaging is well validated for the diagnosis and quantification of myocardial infarction (MI). 2D LGE imaging involves multiple breath-holds for acquisition of short-axis slices to cover the left ventricle (LV). 3D LGE methods cover the LV in a single breath-hold; however, breath-hold duration is typically long with images susceptible to motion artifacts. PURPOSE/HYPOTHESIS: To assess a single breath-hold 3D mDIXON LGE pulse sequence for image quality and quantitation of MI. STUDY TYPE: Prospective. POPULATION: Ninety- two patients with prior MI. FIELD STRENGTH/SEQUENCE: 1.5T cardiac MRI protocol using both conventional 2D phase sensitive inversion recovery and 3D mDIXON LGE imaging 10 minutes following contrast administration in random order to avoid bias. ASSESSMENT: Data were analyzed qualitatively for image quality (three observers). Quantitative assessment of myocardial scar mass (full-width half-maximum), scar transmurality, and contrast-to-noise ratio measurements were performed. Time for 2D and 3D LGE imaging was recorded. STATISTICAL TESTS: Paired Student's t-test, Wilcoxon rank test, Cohen κ statistic, Pearson correlation, linear regression, and Bland-Altman analysis. RESULTS: Image quality scores were comparable between 3D and 2D LGE (1.4 ± 0.6 vs. 1.3 ± 0.5; P = 0.162). 3D LGE was associated with greater scar tissue mass (3D: 18.9 ± 17.5 g vs. 2D: 17.8 ± 16.2 g P = 0.03), although this difference was less pronounced when scar tissue was expressed as %LV mass (3D: 13.4 ± 9.9% vs. 2D: 12.7 ± 9.5% P = 0.07). For 3D vs. 2D scar mass there was a strong and significant positive correlation; Bland-Altman analysis showed mean mass bias of 1.1 g (95% confidence interval [CI]: -5.7 to 7.9). Segmental level agreement of scar transmurality between 3D and 2D LGE at the clinical viability threshold of 50% transmurality was excellent (κ = 0.870). 3D image acquisition (15.6 ± 1.4 sec) was just 5% of time required for 2D images (311.6 ± 43.2 sec) P < 0.0001. DATA CONCLUSION: Single breath-hold 3D mDIXON LGE imaging allows quantitative assessment of MI mass and transmurality, with comparable image quality, in vastly shorter overall acquisition time compared with standard 2D LGE imaging. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:1437-1445.


Subject(s)
Cicatrix/diagnostic imaging , Contrast Media , Gadolinium , Image Enhancement/methods , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Myocardial Ischemia/complications , Breath Holding , Cicatrix/etiology , Feasibility Studies , Female , Humans , Male , Middle Aged , Prospective Studies
6.
J Magn Reson Imaging ; 50(1): 146-152, 2019 07.
Article in English | MEDLINE | ID: mdl-30604492

ABSTRACT

BACKGROUND: Late gadolinium enhancement (LGE) imaging was validated for diagnosis and quantification of myocardial infarction (MI). Despite good contrast between scar and normal myocardium, contrast between blood pool and myocardial scar can be limited. Dark blood LGE sequences attempt to overcome this issue. PURPOSE: To evaluate T1 rho (T1 ρ)-prepared dark blood sequence and compare to blood nulled (BN) phase sensitive inversion recovery (PSIR) and standard myocardium nulled (MN) PSIR for detection and quantification of scar. STUDY TYPE: Prospective. POPULATION: Thirty patients with prior MI. FIELD STRENGTH/SEQUENCE: Patients underwent identical 1.5 T MRI protocols. Following routine LGE imaging, a slice with scar, remote myocardium, and blood pool was selected. PSIR LGE was repeated with inversion time set to MN, to BN, and T1 ρ FIDDLE (flow-independent dark-blood delayed enhancement) in random order. ASSESSMENT: Three observers. Qualitative assessment of confidence scores in scar detection and degree of transmurality. Quantitative assessment of myocardial scar mass (grams), and contrast-to-noise ratio (CNR) measurements between scar, blood pool, and myocardium. STATISTICAL TESTS: Repeated-measures analysis of variance (ANOVA) with Bonferroni correction, coefficient of variation, and the Cohen κ statistic. RESULTS: CNRscar-blood was significantly increased for both BN (27.1 ± 10.4) and T1 ρ (30.2 ± 15.1) compared with MN (15.3 ± 8.4 P < 0.001 for both sequences). There was no significant difference in CNRscar-myo between BN (55.9 ± 17.3) and MN (51.1 ± 17.8 P = 0.512); both had significantly higher CNRscar-myo compared with the T1 ρ (42.6 ± 16.9 P = 0.007 and P = 0.014, respectively). No significant difference in scar size between LGE methods: MN (2.28 ± 1.58 g) BN (2.16 ± 1.57 g) and T1 ρ (2.29 ± 2.5 g). Confidence scores were significantly higher for BN (3.87 ± 0.346) compared with MN (3.1 ± 0.76 P < 0.001) and T1 ρ (3.20 ± 0.71 P < 0.001). DATA CONCLUSION: PSIR with inversion time (TI) set for blood nulling and the T1 ρ LGE sequence demonstrated significantly higher scar to blood CNR compared with routine MN. PSIR with TI set for blood nulling demonstrated significantly higher reader confidence scores compared with routine MN and T1 ρ LGE, suggesting routine adoption of a BN PSIR approach might be appropriate for LGE imaging. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:146-152.


Subject(s)
Cicatrix/diagnostic imaging , Cicatrix/pathology , Image Enhancement/methods , Magnetic Resonance Imaging/methods , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/pathology , Organometallic Compounds/administration & dosage , Contrast Media/administration & dosage , Female , Humans , Male , Middle Aged , Prospective Studies
7.
Eur Heart J Cardiovasc Imaging ; 20(1): 108-117, 2019 01 01.
Article in English | MEDLINE | ID: mdl-30137274

ABSTRACT

Aims: The main aim of this study was to characterize changes in the left ventricular (LV) blood flow kinetic energy (KE) using four-dimensional (4D) flow cardiovascular magnetic resonance imaging (CMR) in patients with myocardial infarction (MI) with/without LV thrombus (LVT). Methods and results: This is a prospective cohort study of 108 subjects [controls = 40, MI patients without LVT (LVT- = 36), and MI patients with LVT (LVT+ = 32)]. All underwent CMR including whole-heart 4D flow. LV blood flow KE wall calculated using the formula: KE=12 ρblood . Vvoxel . v2, where ρ = density, V = volume, v = velocity, and was indexed to LV end-diastolic volume. Patient with MI had significantly lower LV KE components than controls (P < 0.05). LVT+ and LVT- patients had comparable infarct size and apical regional wall motion score (P > 0.05). The relative drop in A-wave KE from mid-ventricle to apex and the proportion of in-plane KE were higher in patients with LVT+ compared with LVT- (87 ± 9% vs. 78 ± 14%, P = 0.02; 40 ± 5% vs. 36 ± 7%, P = 0.04, respectively). The time difference of peak E-wave KE demonstrated a significant rise between the two groups (LVT-: 38 ± 38 ms vs. LVT+: 62 ± 56 ms, P = 0.04). In logistic-regression, the relative drop in A-wave KE (beta = 11.5, P = 0.002) demonstrated the strongest association with LVT. Conclusion: Patients with MI have reduced global LV flow KE. Additionally, MI patients with LVT have significantly reduced and delayed wash-in of the LV. The relative drop of distal intra-ventricular A-wave KE, which represents the distal late-diastolic wash-in of the LV, is most strongly associated with the presence of LVT.


Subject(s)
Heart Ventricles/diagnostic imaging , Magnetic Resonance Imaging/methods , Myocardial Infarction/diagnostic imaging , Thrombosis/diagnostic imaging , Adult , Blood Flow Velocity , Case-Control Studies , Contrast Media , Diastole/physiology , England , Female , Heart Ventricles/physiopathology , Humans , Image Interpretation, Computer-Assisted , Male , Middle Aged , Myocardial Infarction/physiopathology , Netherlands , Prospective Studies , Thrombosis/physiopathology , Ventricular Function, Left
8.
J Cardiovasc Magn Reson ; 20(1): 61, 2018 08 30.
Article in English | MEDLINE | ID: mdl-30165869

ABSTRACT

BACKGROUND: Myocardial infarction (MI) leads to complex changes in left ventricular (LV) haemodynamics that are linked to clinical outcomes. We hypothesize that LV blood flow kinetic energy (KE) is altered in MI and is associated with LV function and infarct characteristics. This study aimed to investigate the intra-cavity LV blood flow KE in controls and MI patients, using cardiovascular magnetic resonance (CMR) four-dimensional (4D) flow assessment. METHODS: Forty-eight patients with MI (acute-22; chronic-26) and 20 age/gender-matched healthy controls underwent CMR which included cines and whole-heart 4D flow. Patients also received late gadolinium enhancement imaging for infarct assessment. LV blood flow KE parameters were indexed to LV end-diastolic volume and include: averaged LV, minimal, systolic, diastolic, peak E-wave and peak A-wave KEiEDV. In addition, we investigated the in-plane proportion of LV KE (%) and the time difference (TD) to peak E-wave KE propagation from base to mid-ventricle was computed. Association of LV blood flow KE parameters to LV function and infarct size were investigated in all groups. RESULTS: LV KEiEDV was higher in controls than in MI patients (8.5 ± 3 µJ/ml versus 6.5 ± 3 µJ/ml, P = 0.02). Additionally, systolic, minimal and diastolic peak E-wave KEiEDV were lower in MI (P < 0.05). In logistic-regression analysis, systolic KEiEDV (Beta = - 0.24, P < 0.01) demonstrated the strongest association with the presence of MI. In multiple-regression analysis, infarct size was most strongly associated with in-plane KE (r = 0.5, Beta = 1.1, P < 0.01). In patients with preserved LV ejection fraction (EF), minimal and in-plane KEiEDV were reduced (P < 0.05) and time difference to peak E-wave KE propagation during diastole increased (P < 0.05) when compared to controls with normal EF. CONCLUSIONS: Reduction in LV systolic function results in reduction in systolic flow KEiEDV. Infarct size is independently associated with the proportion of in-plane LV KE. Degree of LV impairment is associated with TD of peak E-wave KE. In patient with preserved EF post MI, LV blood flow KE mapping demonstrated significant changes in the in-plane KE, the minimal KEiEDV and the TD. These three blood flow KE parameters may offer novel methods to identify and describe this patient population.


Subject(s)
Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging, Cine/methods , Myocardial Perfusion Imaging/methods , ST Elevation Myocardial Infarction/diagnostic imaging , Adult , Aged , Blood Flow Velocity , Case-Control Studies , Contrast Media/administration & dosage , Coronary Circulation , Female , Gadolinium DTPA/administration & dosage , Humans , Male , Middle Aged , Myocardium/pathology , Predictive Value of Tests , Prospective Studies , ST Elevation Myocardial Infarction/pathology , ST Elevation Myocardial Infarction/physiopathology , Ventricular Function, Left
9.
Sci Rep ; 8(1): 14436, 2018 09 26.
Article in English | MEDLINE | ID: mdl-30258186

ABSTRACT

Two-dimensional (2D) methods of assessing mitral inflow velocities are pre-load dependent, limiting their reliability for evaluating diastolic function. Left ventricular (LV) blood flow kinetic energy (KE) derived from four-dimensional flow cardiovascular magnetic resonance imaging (4D flow CMR) may offer improvements. It remains unclear whether 4D LV blood flow KE parameters are associated with physiological factors, such as age when compared to 2D mitral inflow velocities. Fifty-three healthy volunteers underwent standard CMR, plus 4D flow acquisition. LV blood flow KE parameters demonstrated good reproducibility with mean coefficient of variation of 6 ± 2% and an accuracy of 99% with a precision of 97%. The LV blood flow KEiEDV E/A ratio demonstrated good association to the 2D mitral inflow E/A ratio (r = 0.77, P < 0.01), with both decreasing progressively with advancing age (P < 0.01). Furthermore, peak E-wave KEiEDV and A-wave KEiEDV displayed a stronger association to age than the corresponding 2D metrics, peak E-wave and A-wave velocity (r = -0.51 vs -0.17 and r = 0.65 vs 0.46). Peak E-wave KEiEDV decreases whilst peak A-wave KEiEDV increases with advancing age. This study presents values for various LV blood flow KE parameters in health, as well as demonstrating that they show stronger and independent correlations to age than standard diastolic metrics.


Subject(s)
Aging , Blood Flow Velocity , Diastole , Magnetic Resonance Imaging/methods , Ventricular Function, Left , Adult , Female , Hemodynamics , Humans , Image Interpretation, Computer-Assisted/methods , Male , Middle Aged
10.
J Cardiovasc Magn Reson ; 20(1): 48, 2018 07 09.
Article in English | MEDLINE | ID: mdl-29983119

ABSTRACT

BACKGROUND: Non-invasive assessment of myocardial ischaemia is a cornerstone of the diagnosis of coronary artery disease. Measurement of myocardial blood flow (MBF) using positron emission tomography (PET) is the current reference standard for non-invasive quantification of myocardial ischaemia. Dynamic myocardial perfusion cardiovascular magnetic resonance (CMR) offers an alternative to PET and a recently developed method with automated inline perfusion mapping has shown good correlation of MBF values between CMR and PET. This study assessed the repeatability of myocardial perfusion mapping by CMR in healthy subjects. METHODS: Forty-two healthy subjects were recruited and underwent adenosine stress and rest perfusion CMR on two visits. Scans were repeated with a minimum interval of 7 days. Intrastudy rest and stress MBF repeatability were assessed with a 15-min interval between acquisitions. Interstudy rest and stress MBF and myocardial perfusion reserve (MPR) were measured for global myocardium and regionally for coronary territories and slices. RESULTS: There was no significant difference in intrastudy repeated global rest MBF (0.65 ± 0.13 ml/g/min vs 0.62 ± 0.12 ml/g/min, p = 0.24, repeatability coefficient (RC) =24%) or stress (2.89 ± 0.56 ml/g/min vs 2.83 ± 0.64 ml/g/min, p = 0.41, RC = 29%) MBF. No significant difference was seen in interstudy repeatability for global rest MBF (0.64 ± 0.13 ml/g/min vs 0.64 ± 0.15 ml/g/min, p = 0.80, RC = 32%), stress MBF (2.71 ± 0.61 ml/g/min vs 2.55 ± 0.57 ml/g/min, p = 0.12, RC = 33%) or MPR (4.24 ± 0.69 vs 3.73 ± 0.76, p = 0.25, RC = 36%). Regional repeatability was good for stress (RC = 30-37%) and rest MBF (RC = 32-36%) but poorer for MPR (RC = 35-43%). Within subject coefficient of variation was 8% for rest and 11% for stress within the same study, and 11% for rest and 12% for stress between studies. CONCLUSIONS: Fully automated, inline, myocardial perfusion mapping by CMR shows good repeatability that is similar to the published PET literature. Both rest and stress MBF show better repeatability than MPR, particularly in regional analysis.


Subject(s)
Coronary Circulation , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Myocardial Perfusion Imaging/methods , Adenosine/administration & dosage , Adult , Automation , Blood Flow Velocity , Female , Healthy Volunteers , Humans , Male , Observer Variation , Predictive Value of Tests , Reproducibility of Results , Vasodilator Agents/administration & dosage , Young Adult
11.
Circulation ; 138(18): 1935-1947, 2018 10 30.
Article in English | MEDLINE | ID: mdl-30002099

ABSTRACT

BACKGROUND: Aortic valve replacement (AVR) for aortic stenosis is timed primarily on the development of symptoms, but late surgery can result in irreversible myocardial dysfunction and additional risk. The aim of this study was to determine whether the presence of focal myocardial scar preoperatively was associated with long-term mortality. METHODS: In a longitudinal observational outcome study, survival analysis was performed in patients with severe aortic stenosis listed for valve intervention at 6 UK cardiothoracic centers. Patients underwent preprocedural echocardiography (for valve severity assessment) and cardiovascular magnetic resonance for ventricular volumes, function and scar quantification between January 2003 and May 2015. Myocardial scar was categorized into 3 patterns (none, infarct, or noninfarct patterns) and quantified with the full width at half-maximum method as percentage of the left ventricle. All-cause mortality and cardiovascular mortality were tracked for a minimum of 2 years. RESULTS: Six hundred seventy-four patients with severe aortic stenosis (age, 75±14 years; 63% male; aortic valve area, 0.38±0.14 cm2/m2; mean gradient, 46±18 mm Hg; left ventricular ejection fraction, 61.0±16.7%) were included. Scar was present in 51% (18% infarct pattern, 33% noninfarct). Management was surgical AVR (n=399) or transcatheter AVR (n=275). During follow-up (median, 3.6 years), 145 patients (21.5%) died (52 after surgical AVR, 93 after transcatheter AVR). In multivariable analysis, the factors independently associated with all-cause mortality were age (hazard ratio [HR], 1.50; 95% CI, 1.11-2.04; P=0.009, scaled by epochs of 10 years), Society of Thoracic Surgeons score (HR, 1.12; 95% CI, 1.03-1.22; P=0.007), and scar presence (HR, 2.39; 95% CI, 1.40-4.05; P=0.001). Scar independently predicted all-cause (26.4% versus 12.9%; P<0.001) and cardiovascular (15.0% versus 4.8%; P<0.001) mortality, regardless of intervention (transcatheter AVR, P=0.002; surgical AVR, P=0.026 [all-cause mortality]). Every 1% increase in left ventricular myocardial scar burden was associated with 11% higher all-cause mortality hazard (HR, 1.11; 95% CI, 1.05-1.17; P<0.001) and 8% higher cardiovascular mortality hazard (HR, 1.08; 95% CI, 1.01-1.17; P<0.001). CONCLUSIONS: In patients with severe aortic stenosis, late gadolinium enhancement on cardiovascular magnetic resonance was independently associated with mortality; its presence was associated with a 2-fold higher late mortality.


Subject(s)
Aortic Valve Stenosis/pathology , Myocardium/pathology , Aged , Aged, 80 and over , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/surgery , Cicatrix , Contrast Media/chemistry , Echocardiography , Female , Gadolinium/chemistry , Humans , Kaplan-Meier Estimate , Longitudinal Studies , Magnetic Resonance Imaging, Cine , Male , Middle Aged , Proportional Hazards Models , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Treatment Outcome
12.
J Interv Cardiol ; 31(3): 391-399, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29696693

ABSTRACT

OBJECTIVES: We sought to compare using serial CMR, the quantity of AR and associated valve hemodynamics, following the first-generation CoreValve (Medtronic, Minneapolis, MN) and the second-generation Lotus valve (Boston Scientific, Natick, MA). BACKGROUND: Aortic regurgitation (AR) following Transcatheter Aortic Valve Replacement (TAVR) confers a worse prognosis and can be accurately quantified using cardiovascular magnetic resonance (CMR). Second generation valves have been specifically designed to reduce paravalvular AR and improve clinical outcomes. METHODS: Fifty-one patients (79.0 ± 7.7 years, 57% male) were recruited and imaged at three time points: immediately pre- and post-TAVR, and at 6 months. RESULTS: CMR-derived AR fraction immediately post-TAVR was greater in the CoreValve compared to Lotus group (11.7 ± 8.4 vs. 4.3 ± 3.4%, P = 0.001), as was the frequency of ≥moderate AR (9/24 (37.5%) versus 0/27, P < 0.001). However, at 6 months AR fraction had improved significantly in the CoreValve group such that the two valve designs were comparable (6.4 ± 5.0 vs 5.6 ± 5.3%, P = 0.623), with no patient in either group having ≥moderate AR. The residual peak pressure gradient immediately following TAVR was significantly lower with CoreValve compared to Lotus (14.1 ± 5.6 vs 25.4 ± 11.6 mmHg, P = 0.001), but again by 6 months the two valve designs were comparable (16.5 ± 9.4 vs 19.7 ± 10.5 mmHg, P = 0.332). There was no difference in the degree of LV reverse remodeling between the two valves at 6 months. CONCLUSION: Immediately post-TAVR, there was significantly less AR but a higher residual peak pressure gradient with the Lotus valve compared to CoreValve. However, at 6 months both devices had comparable valve hemodynamics and LV reverse remodeling.


Subject(s)
Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis , Magnetic Resonance Imaging , Aged , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Insufficiency/etiology , Aortic Valve Stenosis/complications , Female , Hemodynamics , Humans , Male , Prosthesis Design , Transcatheter Aortic Valve Replacement , Treatment Outcome
13.
J Magn Reson Imaging ; 47(1): 272-281, 2018 01.
Article in English | MEDLINE | ID: mdl-28470915

ABSTRACT

PURPOSE: To validate three widely-used acceleration methods in four-dimensional (4D) flow cardiac MR; segmented 4D-spoiled-gradient-echo (4D-SPGR), 4D-echo-planar-imaging (4D-EPI), and 4D-k-t Broad-use Linear Acquisition Speed-up Technique (4D-k-t BLAST). MATERIALS AND METHODS: Acceleration methods were investigated in static/pulsatile phantoms and 25 volunteers on 1.5 Tesla MR systems. In phantoms, flow was quantified by 2D phase-contrast (PC), the three 4D flow methods and the time-beaker flow measurements. The later was used as the reference method. Peak velocity and flow assessment was done by means of all sequences. For peak velocity assessment 2D PC was used as the reference method. For flow assessment, consistency between mitral inflow and aortic outflow was investigated for all pulse-sequences. Visual grading of image quality/artifacts was performed on a four-point-scale (0 = no artifacts; 3 = nonevaluable). RESULTS: For the pulsatile phantom experiments, the mean error for 2D PC = 1.0 ± 1.1%, 4D-SPGR = 4.9 ± 1.3%, 4D-EPI = 7.6 ± 1.3% and 4D-k-t BLAST = 4.4 ± 1.9%. In vivo, acquisition time was shortest for 4D-EPI (4D-EPI = 8 ± 2 min versus 4D-SPGR = 9 ± 3 min, P < 0.05 and 4D-k-t BLAST = 9 ± 3 min, P = 0.29). 4D-EPI and 4D-k-t BLAST had minimal artifacts, while for 4D-SPGR, 40% of aortic valve/mitral valve (AV/MV) assessments scored 3 (nonevaluable). Peak velocity assessment using 4D-EPI demonstrated best correlation to 2D PC (AV:r = 0.78, P < 0.001; MV:r = 0.71, P < 0.001). Coefficient of variability (CV) for net forward flow (NFF) volume was least for 4D-EPI (7%) (2D PC:11%, 4D-SPGR: 29%, 4D-k-t BLAST: 30%, respectively). CONCLUSION: In phantom, all 4D flow techniques demonstrated mean error of less than 8%. 4D-EPI demonstrated the least susceptibility to artifacts, good image quality, modest agreement with the current reference standard for peak intra-cardiac velocities and the highest consistency of intra-cardiac flow quantifications. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:272-281.


Subject(s)
Heart/diagnostic imaging , Imaging, Three-Dimensional , Magnetic Resonance Imaging, Cine , Phantoms, Imaging , Adult , Aortic Valve/diagnostic imaging , Artifacts , Blood Flow Velocity , Echo-Planar Imaging , Female , Healthy Volunteers , Heart Ventricles/diagnostic imaging , Humans , Image Interpretation, Computer-Assisted , Image Processing, Computer-Assisted , Male , Middle Aged , Mitral Valve/diagnostic imaging , Reference Values , Reproducibility of Results , Systole , Young Adult
14.
Eur Heart J Cardiovasc Imaging ; 19(7): 816-823, 2018 07 01.
Article in English | MEDLINE | ID: mdl-29029139

ABSTRACT

Aims: To test the hypothesis that patients with ischaemic cardiomyopathy (ICM) and non-ischaemic cardiomyopathy (NICM) have different torsion and strain parameters, and compare to healthy, age-matched controls. VINDICATE investigated efficacy of high-dose vitamin D on patients with heart failure (HF) secondary to left ventricular (LV) systolic dysfunction of any aetiology. It is important to differentiate ICM and NICM as treatment and prognosis varies significantly. Cardiovascular magnetic resonance (CMR) reliably determines aetiology of HF and tissue tagging techniques are recognized as the reference standard measures of strain and torsion. Methods and results: Fifty three patients (31 ICM, 22 NICM) from VINDICATE and 25 controls underwent CMR at 3.0T, including cine imaging in multiple planes and tissue tagging by spatial modulation of magnetization. CMR data were analysed blinded, by quantitatively reporting circumferential strain and torsion from tagged images and global longitudinal strain from feature tracking. HF patients had larger ventricles indexed to body surface area, lower left ventricular ejection fraction (LVEF), LV torsion, twist, and strain parameters compared to controls. There were no significant differences between ICM and NICM in age, blood pressure, heart rhythm, or NYHA status. There was no significant difference in LV dimensions, EF, and strain parameters between ICM and NICM. NICM patients had significantly lower LV twist (6.0 ± 3.7° vs. 8.8 ± 4.3°, P = 0.023) and torsion (5.9 ± 3.5° vs. 8.8 ± 4.7°, P = 0.017) compared to ICM. Conclusion: Twist, torsion, and strain are reduced in HF patients compared to controls. Torsion and twist are significantly lower in patients with NICM compared to ICM, despite similar volumetric dimensions, circumferential and longitudinal strain parameters, and LVEF.


Subject(s)
Cardiomyopathies/diagnostic imaging , Heart Failure/diagnostic imaging , Image Interpretation, Computer-Assisted , Magnetic Resonance Imaging, Cine/methods , Myocardial Ischemia/diagnostic imaging , Adult , Aged , Aged, 80 and over , Cardiomyopathies/etiology , Cardiomyopathies/physiopathology , Case-Control Studies , Evaluation Studies as Topic , Female , Heart Failure/complications , Heart Failure/physiopathology , Humans , Male , Middle Aged , Myocardial Ischemia/complications , Myocardial Ischemia/physiopathology , Prognosis , Retrospective Studies , Severity of Illness Index , Torsion, Mechanical , Ventricular Remodeling/physiology
15.
J Cardiovasc Magn Reson ; 19(1): 84, 2017 Nov 06.
Article in English | MEDLINE | ID: mdl-29110669

ABSTRACT

BACKGROUND: Assessment of left main stem (LMS) stenosis has prognostic and therapeutic implications. Data on assessment of LMS disease by cardiovascular magnetic resonance (CMR) and single photon emission computed tomography (SPECT) are limited. CE-MARC is the largest prospective comparison of CMR and SPECT against quantitative invasive coronary angiography (QCA) for detection of coronary artery disease (CAD), and provided the framework for this evaluation. The aims of this study were to compare diagnostic accuracy of visual and quantitative perfusion CMR to SPECT in patients with LMS stable CAD. METHODS: Fifty-four patients from the CE-MARC study were included: 27 (4%) with significant LMS or LMS-equivalent disease on QCA, and 27 age/sex-matched patients with no flow-limiting CAD. All patients underwent multi-parametric CMR, SPECT and QCA. Performance of visual and quantitative perfusion CMR by Fermi-constrained deconvolution to detect LMS disease was compared with SPECT. RESULTS: Of 27 patients in the LMS group, 22 (81%) had abnormal CMR and 16 (59%) had abnormal SPECT. All patients with abnormal CMR had abnormal perfusion by visual analysis. CMR demonstrated significantly higher area under the curve (AUC) for detection of disease (0.95; 0.85-0.99) over SPECT (0.63; 0.49-0.76) (p = 0.0001). Global mean stress myocardial blood flow (MBF) by CMR in LMS patients was significantly lower than controls (1.77 ± 0.72 ml/g/min vs. 3.28 ± 1.20 ml/g/min, p < 0.001). MBF of <2.08 ml/g/min had sensitivity of 78% and specificity of 85% for diagnosis of LMS disease, with an AUC (0.87; 0.75-0.94) not significantly different to visual CMR analysis (p = 0.18), and more accurate than SPECT (p = 0.003). CONCLUSION: Visual stress perfusion CMR had higher diagnostic accuracy than SPECT to detect LMS disease. Quantitative perfusion CMR had similar performance to visual CMR perfusion analysis.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Coronary Circulation , Coronary Stenosis/diagnostic imaging , Coronary Vessels/diagnostic imaging , Magnetic Resonance Imaging, Cine , Myocardial Perfusion Imaging/methods , Tomography, Emission-Computed, Single-Photon , Aged , Area Under Curve , Case-Control Studies , Contrast Media/administration & dosage , Coronary Angiography , Coronary Artery Disease/physiopathology , Coronary Stenosis/physiopathology , Coronary Vessels/physiopathology , Female , Humans , Image Interpretation, Computer-Assisted , Male , Middle Aged , Predictive Value of Tests , ROC Curve , Reproducibility of Results , Severity of Illness Index , Ventricular Function, Left
16.
J Cardiovasc Magn Reson ; 19(1): 73, 2017 Sep 25.
Article in English | MEDLINE | ID: mdl-28946878

ABSTRACT

BACKGROUND: Expansion of the myocardial extracellular volume (ECV) is a surrogate measure of focal/diffuse fibrosis and is an independent marker of prognosis in chronic heart disease. Changes in ECV may also occur after myocardial infarction, acutely because of oedema and in convalescence as part of ventricular remodelling. The objective of this study was to investigate changes in the pattern of distribution of regional (normal, infarcted and oedematous segments) and global left ventricular (LV) ECV using semi-automated methods early and late after reperfused ST-elevation myocardial infarction (STEMI). METHODS: Fifty patients underwent cardiovascular magnetic resonance (CMR) imaging acutely (24 h-72 h) and at convalescence (3 months). The CMR protocol included: cines, T2-weighted (T2 W) imaging, pre-/post-contrast T1-maps and LGE-imaging. Using T2 W and LGE imaging on acute scans, 16-segments of the LV were categorised as normal, oedema and infarct. 800 segments (16 per-patient) were analysed for changes in ECV and wall thickening (WT). RESULTS: From the acute studies, 325 (40.6%) segments were classified as normal, 246 (30.8%) segments as oedema and 229 (28.6%) segments as infarct. Segmental change in ECV between acute and follow-up studies (Δ ECV) was significantly different for normal, oedema and infarct segments (0.8 ± 6.5%, -1.78 ± 9%, -2.9 ± 10.9%, respectively; P < 0.001). Normal segments which demonstrated deterioration in wall thickening at follow-up showed significantly increased Δ ECV compared with normal segments with preserved wall thickening at follow up (1.82 ± 6.05% versus -0.10 ± 6.88%, P < 0.05). CONCLUSION: Following reperfused STEMI, normal myocardium demonstrates subtle expansion of the extracellular volume at 3-month follow up. Segmental ECV expansion of normal myocardium is associated with worsening of contractile function.


Subject(s)
Heart/physiopathology , Magnetic Resonance Imaging/methods , Myocardial Infarction/pathology , Myocardium/pathology , Edema/diagnostic imaging , Edema/physiopathology , Female , Fibrosis , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Humans , Male , Middle Aged , Myocardial Infarction/physiopathology , Prospective Studies , United Kingdom , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/physiopathology
17.
Circ Cardiovasc Imaging ; 10(7)2017 Jul.
Article in English | MEDLINE | ID: mdl-28674085

ABSTRACT

BACKGROUND: Late gadolinium enhancement (LGE) imaging overestimates acute infarct size. The main aim of this study was to investigate whether acute extracellular volume (ECV) maps can reliably quantify myocardial area at risk (AAR) and final infarct size (IS). METHODS AND RESULTS: Fifty patients underwent cardiovascular magnetic resonance imaging acutely (24-72 hours) and at convalescence (3 months). The cardiovascular magnetic resonance protocol included cines, T2-weighted imaging, native T1 maps, 15-minute post-contrast T1 maps, and LGE. Optimal AAR and IS ECV thresholds were derived in a validation group of 10 cases (160 segments). Eight hundred segments (16 per patient) were analyzed to quantify AAR/IS by ECV maps (ECV thresholds for AAR is 33% and IS is 46%), T2-weighted imaging, T1 maps, and acute LGE. Follow-up LGE imaging was used as the reference standard for final IS and viability assessment. The AAR derived from ECV maps (threshold of >33) demonstrated good agreement with T2-weighted imaging-derived AAR (bias, 0.18; 95% confidence interval [CI], -1.6 to 1.3) and AAR derived from native T1 maps (bias=1; 95% CI, -0.37 to 2.4). ECV demonstrated the best linear correlation to final IS at a threshold of >46% (R=0.96; 95% CI, 0.92-0.98; P<0.0001). ECV maps demonstrated better agreement with final IS than acute IS on LGE (ECV maps: bias, 1.9; 95% CI, 0.4-3.4 versus LGE imaging: bias, 10; 95% CI, 7.7-12.4). On multiple variable regression analysis, the number of nonviable segments was independently associated with IS by ECV maps (ß=0.86; P<0.0001). CONCLUSIONS: ECV maps can reliably quantify AAR and final IS in reperfused acute myocardial infarction. Acute ECV maps were superior to acute LGE in terms of agreement with final IS. IS quantified by ECV maps are independently associated with viability at follow-up.


Subject(s)
Magnetic Resonance Imaging , Myocardium/pathology , ST Elevation Myocardial Infarction/diagnostic imaging , Aged , Chi-Square Distribution , Contrast Media/administration & dosage , England , Female , Humans , Image Interpretation, Computer-Assisted , Linear Models , Male , Middle Aged , Multivariate Analysis , Percutaneous Coronary Intervention , Predictive Value of Tests , Prospective Studies , Reproducibility of Results , ST Elevation Myocardial Infarction/pathology , ST Elevation Myocardial Infarction/physiopathology , ST Elevation Myocardial Infarction/therapy , Time Factors , Tissue Survival , Treatment Outcome , Ventricular Function, Left , Ventricular Remodeling
18.
Int J Cardiovasc Imaging ; 33(10): 1561-1569, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28421305

ABSTRACT

Prior myocardial infarction (MI) is associated with increased mortality and is prevalent in certain high risk patient groups. Electrocardiogram may be used in diagnosis, however, sensitivity is limited, thus non-invasive imaging techniques may improve diagnosis. We investigated whether global longitudinal strain (GLS) and longitudinal strain parameters are reduced in patients with prior MI but preserved left ventricular ejection fraction (LVEF). The study included 40 clinical patients with prior MI occurring >3 months previously (defined as subendocardial hyperenhancement on late Gadolinium enhancement imaging) with LVEF ≥ 55% and 40 controls matched for age and LVEF. GLS, global longitudinal strain rate (GLSR) and early diastolic longitudinal strain rate (GLSRe) were measured from cine imaging feature tracking analysis. Presence of wall motion abnormality (WMA) and minimum systolic wall thickening (SWT) were calculated from cine imaging. GLS was -17.3 ± 3.7% in prior MI versus -19.3 ± 1.9% in controls (p = 0.012). GLSR was -88.0 ± 33.7%/s in prior MI versus -103.3 ± 26.5%/s in controls (p = 0.005). GLSRe was 76.4 ± 28.4%/s in prior MI versus 95.5 ± 26.0%/s in controls (p = 0.001). GLS accurately identified prior MI [AUC 0.662 (95% CI 0.54-0.785) p = 0.012] whereas WMA [AUC 0.500 (95% CI 0.386-0.614) p = 1.0] and minimum SWT [AUC 0.609 (95% CI 0.483-0.735) p = 0.093] did not. GLS, GLSR and GLSRe are reduced in prior MI with preserved LVEF. Normal LVEF and lack of WMA cannot exclude prior MI. Prior MI should be considered when reduced GLS, GLSR or GLSRe are detected by non-invasive imaging.


Subject(s)
Magnetic Resonance Imaging, Cine , Myocardial Contraction , Myocardial Infarction/diagnostic imaging , Stroke Volume , Ventricular Function, Left , Aged , Area Under Curve , Biomechanical Phenomena , Contrast Media/administration & dosage , Female , Humans , Image Interpretation, Computer-Assisted , Linear Models , Male , Middle Aged , Multivariate Analysis , Myocardial Infarction/physiopathology , Observer Variation , Organometallic Compounds/administration & dosage , Predictive Value of Tests , ROC Curve , Reproducibility of Results , Retrospective Studies , Stress, Mechanical , Time Factors
19.
World J Cardiol ; 9(2): 92-108, 2017 Feb 26.
Article in English | MEDLINE | ID: mdl-28289524

ABSTRACT

Coronary artery disease (CAD) is a leading cause of death and disability worldwide. Cardiovascular magnetic resonance (CMR) is established in clinical practice guidelines with a growing evidence base supporting its use to aid the diagnosis and management of patients with suspected or established CAD. CMR is a multi-parametric imaging modality that yields high spatial resolution images that can be acquired in any plane for the assessment of global and regional cardiac function, myocardial perfusion and viability, tissue characterisation and coronary artery anatomy, all within a single study protocol and without exposure to ionising radiation. Advances in technology and acquisition techniques continue to progress the utility of CMR across a wide spectrum of cardiovascular disease, and the publication of large scale clinical trials continues to strengthen the role of CMR in daily cardiology practice. This article aims to review current practice and explore the future directions of multi-parametric CMR imaging in the investigation of stable CAD.

SELECTION OF CITATIONS
SEARCH DETAIL
...