Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Ophthalmol Glaucoma ; 5(5): 468-475, 2022.
Article in English | MEDLINE | ID: mdl-35304317

ABSTRACT

PURPOSE: To evaluate the effect of postoperative topical prednisolone acetate and difluprednate on surgical outcomes of Ahmed glaucoma valve (AGV) implantation. DESIGN: Retrospective, comparative case series. PARTICIPANTS: The study population consisted of 102 eyes of 90 patients, including 52 eyes that received 1% prednisolone acetate (Pred Forte [PF]; Allergan Inc) and 50 eyes that received 0.05% difluprednate (Durezol [DZ]; Novartis Inc). METHODS: The medical records of consecutive patients who underwent AGV implantation at the University of California, San Francisco, were retrospectively reviewed. Patients in the PF group received 1% prednisolone acetate 6 to 8 times per day tapered over 5 to 6 months postoperatively, and patients in the DZ group received 0.05% difluprednate 4 times daily tapered over 4 months postoperatively. MAIN OUTCOME MEASURES: Intraocular pressure (IOP), number of glaucoma medications, visual acuity (VA), postoperative complications, and the rate of treatment success. RESULTS: At 1 year, the IOPs (mean ± standard deviation) were 12.4 ± 3.7 mmHg in the DZ group and 13.0 ± 4.0 mmHg in the PF group (P = 0.49). The numbers of glaucoma medications were 0.72 ± 0.71 in the DZ group and 1.09 ± 0.91 in the PF group (P = 0.04), with reductions from baseline of 2.5 ± 1.0 glaucoma medications in the DZ group and 1.8 ± 1.6 glaucoma medications in the PF group (P = 0.01). The logarithm of the minimum angle of resolution VAs (mean ± standard deviation) were 0.55 ± 0.80 in the DZ group and 0.59 ± 0.65 in the PF group after 1 year of follow-up (P = 0.81). The cumulative probabilities of success were 95.8% in the DZ group and 93.5% in the PF group at 1 year (P = 0.61). Postoperative complications occurred in 4 eyes (7.7%) in the DZ group and 6 eyes (12%) in the PF group (P = 0.52). CONCLUSIONS: After 1 year, postoperative treatment with 0.05% difluprednate after AGV implantation resulted in a similar IOP, with the use of fewer glaucoma medications, compared with postoperative treatment with 1% prednisolone acetate. The rates of treatment success and surgical complications were comparable between the 2 groups during the first year of follow-up.


Subject(s)
Glaucoma Drainage Implants , Glaucoma , Fluprednisolone/analogs & derivatives , Follow-Up Studies , Glaucoma/drug therapy , Glaucoma/surgery , Humans , Postoperative Complications , Prednisolone/analogs & derivatives , Retrospective Studies , Treatment Outcome
2.
Curr Eye Res ; 46(12): 1853-1860, 2021 12.
Article in English | MEDLINE | ID: mdl-34253093

ABSTRACT

Purpose: To evaluate the inter- and intra-observer reliability of anterior chamber (AC) angle measurements obtained by swept-source optical coherence tomography (SS-OCT).Methods: Forty-eight consecutive patients diagnosed with primary angle closure suspect (PACS) were included. Three masked observers at different training levels (one glaucoma specialist, one ophthalmology resident, and one pre-medical college student) measured 192 SS-OCT images of the PACS patients. One observer (the glaucoma specialist) repeated measurements 1 week later. SS-OCT parameters included: Anterior segment volume, including corneal, AC, and iris volume; anterior segment dimensions, including AC depth and width (ACD, ACW), and lens vault (LV); and angle parameters, including angle opening distance (AOD), angle recess area (ARA), trabecular iris space area (TISA), and the trabecular iris angle (TIA). Intraclass correlation coefficients (ICCs) were used to measure reliability.Results: For inter-observer reproducibility, ICCs of corneal, AC, and iris volumes were 0.952 to 0.998. ICCs of ACD at all axes were above 0.989. ICCs of ACW and LV were smallest in the 90°-270° axis (0.751 and 0.768) but not significantly different from other axes. ARA, TISA, and TIA at all angles had significantly smallest ICCs 250 µm from the scleral spur compared with 500 µm and 750 µm. The ICCs comparing observers with different training levels had similar ranges and followed similar trends. For intra-observer repeatability, the smallest ICC was 0.843. Decreasing AC depth correlated with increased inter-observer reproducibility.Conclusions: We found excellent intra-observer repeatability for all SS-OCT parameters. Angle measurements have more variation among the observers when taken 250 µm from the scleral spur. Shallow AC might lead to more variability for angle parameters. Non-expert observers may be recruited for high-quality image grading with standard training.


Subject(s)
Anterior Chamber/diagnostic imaging , Glaucoma, Angle-Closure/diagnosis , Intraocular Pressure/physiology , Tomography, Optical Coherence/methods , Female , Glaucoma, Angle-Closure/physiopathology , Humans , Male , Middle Aged , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...