Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Eur Heart J ; 39(15): 1224-1245, 2018 04 14.
Article in English | MEDLINE | ID: mdl-28430909

ABSTRACT

The VARC (Valve Academic Research Consortium) for transcatheter aortic valve replacement set the standard for selecting appropriate clinical endpoints reflecting safety and effectiveness of transcatheter devices, and defining single and composite clinical endpoints for clinical trials. No such standardization exists for circumferentially sutured surgical valve paravalvular leak (PVL) closure. This document seeks to provide core principles, appropriate clinical endpoints, and endpoint definitions to be used in clinical trials of PVL closure devices. The PVL Academic Research Consortium met to review evidence and make recommendations for assessment of disease severity, data collection, and updated endpoint definitions. A 5-class grading scheme to evaluate PVL was developed in concordance with VARC recommendations. Unresolved issues in the field are outlined. The current PVL Academic Research Consortium provides recommendations for assessment of disease severity, data collection, and endpoint definitions. Future research in the field is warranted.


Subject(s)
Aortic Valve/surgery , Clinical Trials as Topic/methods , Heart Valve Prosthesis/adverse effects , Transcatheter Aortic Valve Replacement/adverse effects , Vascular Closure Devices/standards , Aortic Valve/pathology , Aortic Valve Insufficiency/complications , Aortic Valve Insufficiency/surgery , Cardiac Catheterization/methods , Cardiac Catheterization/standards , Clinical Trials as Topic/standards , Echocardiography/methods , Endpoint Determination , Heart Valve Prosthesis/standards , Humans , Outcome Assessment, Health Care , Research Design , Risk Assessment , Severity of Illness Index , Sutures
2.
J Am Coll Cardiol ; 69(16): 2067-2087, 2017 Apr 25.
Article in English | MEDLINE | ID: mdl-28427582

ABSTRACT

The VARC (Valve Academic Research Consortium) for transcatheter aortic valve replacement set the standard for selecting appropriate clinical endpoints reflecting safety and effectiveness of transcatheter devices, and defining single and composite clinical endpoints for clinical trials. No such standardization exists for circumferentially sutured surgical valve paravalvular leak (PVL) closure. This document seeks to provide core principles, appropriate clinical endpoints, and endpoint definitions to be used in clinical trials of PVL closure devices. The PVL Academic Research Consortium met to review evidence and make recommendations for assessment of disease severity, data collection, and updated endpoint definitions. A 5-class grading scheme to evaluate PVL was developed in concordance with VARC recommendations. Unresolved issues in the field are outlined. The current PVL Academic Research Consortium provides recommendations for assessment of disease severity, data collection, and endpoint definitions. Future research in the field is warranted.


Subject(s)
Aortic Valve , Heart Valve Prosthesis/adverse effects , Outcome Assessment, Health Care/methods , Transcatheter Aortic Valve Replacement , Clinical Trials as Topic , Echocardiography , Humans , Research Design , Risk Assessment
SELECTION OF CITATIONS
SEARCH DETAIL