Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Viruses ; 16(5)2024 05 09.
Article in English | MEDLINE | ID: mdl-38793631

ABSTRACT

Viral co-infections are frequently observed among children, but whether specific viral interactions enhance or diminish the severity of respiratory disease is still controversial. This study aimed to investigate the type of viral mono- and co-infections by also evaluating viral correlations in 3525 respiratory samples from 3525 pediatric in/outpatients screened by the Allplex Respiratory Panel Assays and with a Severe Acute Respiratory Syndrome-COronaVirus 2 (SARS-CoV-2) test available. Overall, viral co-infections were detected in 37.8% of patients and were more frequently observed in specimens from children with lower respiratory tract infections compared to those with upper respiratory tract infections (47.1% vs. 36.0%, p = 0.003). SARS-CoV-2 and influenza A were more commonly detected in mono-infections, whereas human bocavirus showed the highest co-infection rate (87.8% in co-infection). After analyzing viral pairings using Spearman's correlation test, it was noted that SARS-CoV-2 was negatively associated with all other respiratory viruses, whereas a markedly significant positive correlation (p < 0.001) was observed for five viral pairings (involving adenovirus/human bocavirus/human enterovirus/metapneumoviruses/rhinovirus). The correlation between co-infection and clinical outcome may be linked to the type of virus(es) involved in the co-infection rather than simple co-presence. Further studies dedicated to this important point are needed, since it has obvious implications from a diagnostic and clinical point of view.


Subject(s)
COVID-19 , Coinfection , Hospitals, Pediatric , Respiratory Tract Infections , SARS-CoV-2 , Tertiary Care Centers , Humans , Coinfection/epidemiology , Coinfection/virology , Respiratory Tract Infections/virology , Respiratory Tract Infections/epidemiology , Italy/epidemiology , Child, Preschool , Child , Infant , Female , Male , Tertiary Care Centers/statistics & numerical data , COVID-19/epidemiology , COVID-19/virology , SARS-CoV-2/isolation & purification , Adolescent , Human bocavirus/isolation & purification , Human bocavirus/genetics , Virus Diseases/epidemiology , Virus Diseases/virology , Hospitalization , Viruses/isolation & purification , Viruses/classification , Viruses/genetics , Infant, Newborn , Metapneumovirus/isolation & purification , Metapneumovirus/genetics
2.
Microorganisms ; 12(4)2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38674772

ABSTRACT

This study described 17 cases of children admitted to the Bambino Gesù Children's Hospital with acute hepatitis of unknown origin between mid-April and November 2022. Following the World Health Organization's working case definition of probable cases, 17 children, with a median age of 2.1 years (interquartile range: 1.0-7.1), presenting with acute hepatitis non-AE, with serum transaminase >500 IU/L, were included in the study. A pre-specified set of microbiological tests was performed on different biological specimens for all pediatric patients. All patients resulted negative for the common hepatotropic viruses. The most common pathogen detected in blood specimens was human-herpes-virus-7 (52.9%). Adenovirus was detected more frequently in stool specimens (62.5%) than in respiratory (20.0%) or blood samples (17.6%). Regarding Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) infection, one child tested positive two days after admission, while antibodies against spike and nucleoprotein were present in 82.3% of patients. A co-pathogen detection was observed in 94.1% of children. Overall, 16 children recovered without clinical complications, while one patient required liver transplantation. In these cases of acute hepatitis of unknown origin, adenovirus was mainly detected in stool samples. A co-pathogen detection was also frequently observed, suggesting that the etiology of this acute hepatitis is most probably multifactorial.

3.
J Med Virol ; 95(9): e29107, 2023 09.
Article in English | MEDLINE | ID: mdl-37721473

ABSTRACT

Anelloviridae and Human Pegivirus 1 (HPgV-1) blood burden have been postulated to behave as surrogate markers for immunosuppression in transplant recipients. Here, we assessed the potential utility plasma Torque teno virus (TTV), total Anelloviridae (TAV), and HPgV-1 load monitoring for the identification of allogeneic hematopoietic stem cell transplantation recipients (allo-HSCT) at increased risk of infectious events or acute graft versus host disease (aGvHD). In this single-center, observational study, plasma TTV DNA, TAV DNA, and HPgV-1 RNA loads were monitored in 75 nonconsecutive allo-HSCT recipients (median age, 54 years). Monitoring was conducted before at baseline or by days +30, +60, +90, +120, and +180 after transplantation. Pneumonia due to different viruses or Pneumocystis jirovecii, BK polyomavirus-associated haemorrhagic cystitis (BKPyV-HC), and Cytomegalovirus DNAemia were the infectious events considered in the current study. Kinetics of plasma TTV, TAV DNA, and HPgV-1 RNA load was comparable, with though and peak levels measured by days +30 and day +90 (+120 for HPgV-1). Forty patients (53%) developed one or more infectious events during the first 180 days after allo-HSCT, whereas 29 patients (39%) had aGvHD (grade II-IV in 18). Neither, TTV, TAV, nor HPgV-1 loads were predictive of overall infection or CMV DNAemia. A TTV DNA load cut-off ≥4.40 log10 (pretransplant) and ≥4.58 log10 (baseline) copies/mL predicted the occurrence of BKPyV-HC (sensitivity ≥89%, negative predictive value, ≥96%). TTV DNA loads ≥3.38 log10 by day +30 anticipated the occurrence of aGvHD (sensitivity, 90%; negative predictive value, 97%). Pretransplant HPgV-1 loads were significantly lower (p = 0.03) in patients who had aGvHD than in those who did not. Monitoring of TTV DNA or HPgV-1 RNA plasma levels either before or early after transplantation may be ancillary to identify allo-HSCT recipients at increased risk of BKPyV-HC or aGvHD.


Subject(s)
Anelloviridae , BK Virus , GB virus C , Graft vs Host Disease , Hematopoietic Stem Cell Transplantation , Torque teno virus , Humans , Middle Aged , Anelloviridae/genetics , Torque teno virus/genetics , Viral Load , Hematopoietic Stem Cell Transplantation/adverse effects
4.
Transplantation ; 107(2): 511-520, 2023 02 01.
Article in English | MEDLINE | ID: mdl-36042550

ABSTRACT

BACKGROUND: Torque teno virus, the major member of the genus Alphatorquevirus , is an emerging biomarker of the net state of immunosuppression after kidney transplantation. Genetic diversity constitutes a main feature of the Anelloviridae family, although its posttransplant dynamics and clinical correlates are largely unknown. METHODS: The relative abundance of Alphatorquevirus , Betatorquevirus , and Gammatorquevirus genera was investigated by high-throughput sequencing in plasma specimens obtained at various points during the first posttransplant year (n = 91 recipients). Total loads of all members of the Anelloviridae family were also quantified by an "in-house" polymerase chain reaction assay targeting conserved DNA sequences (n = 195 recipients). In addition to viral kinetics, clinical study outcomes included serious infection, immunosuppression-related adverse event (opportunistic infection and cancer)' and acute rejection. RESULTS: Alphatorquevirus DNA was detected in all patients at every point, with an increase from pretransplantation to month 1. A variable proportion of recipients had detectable Betatorquevirus and Gammatorquevirus at lower frequencies. At least 1 change in the predominant genus (mainly as early transition to Alphatorquevirus predominance) was shown in 35.6% of evaluable patients. Total anelloviruses DNA levels increased from baseline to month 1, to peak by month 3 and decrease thereafter, and were higher in patients treated with T-cell depleting agents. There was a significant albeit weak-to-moderate correlation between total anelloviruses and TTV DNA levels. No associations were found between the predominant Anelloviridae genus or total anelloviruses DNA levels and clinical outcomes. CONCLUSIONS: Our study provides novel insight into the evolution of the anellome after kidney transplantation.


Subject(s)
Anelloviridae , Kidney Transplantation , Torque teno virus , Humans , Anelloviridae/genetics , Kidney Transplantation/adverse effects , DNA, Viral/genetics , Torque teno virus/genetics , Immunosuppression Therapy , Viral Load
5.
J Clin Virol ; 148: 105082, 2022 03.
Article in English | MEDLINE | ID: mdl-35091226

ABSTRACT

BACKGROUND: Torque teno virus (TTV) DNA load in plasma directly associates with the net state of immunosuppression and inflammation in different clinical settings, including transplantation and chronic inflammatory diseases. OBJECTIVES: We investigated whether plasma TTV DNA load may predict the occurrence of certain infectious events and overall mortality in critically ill COVID-19 patients. PATIENTS AND METHODS: 50 patients (median age, 65.5 years) were recruited. TTV DNA load was quantitated in serial plasma specimens by real-time PCR. Serum levels of interleukin-6, C-reactive protein, ferritin, lactate dehydrogenase, Gamma-Glutamyl Transferase (GGT), alanine transaminase (ALT) and aspartate transaminase (AST) and absolute lymphocyte counts (ALC) in paired specimens were available. Nosocomial bloodstream infections and ventilator-associated pneumonia and overall mortality were the clinical outcomes. RESULTS: TTV DNA was detected in 38 patients (76%). A weak inverse correlation (Rho=-0.28; P = 0.004) was observed between TTV DNA loads and ALC. No direct correlation was found between TTV DNA load and serum levels of any of the above biomarkers. Patients with detectable TTV DNA had an increased risk of subsequently developing infectious events (HR 9.28; 95% CI, 1.29-69.5; P = 0.03). A trend (P = 0.05) towards higher TTV DNA area under a curve between days 7 and 17 after ICU admission (AUC7-17) was observed in patients who died, as compared to survivors. CONCLUSION: Our findings suggested that plasma TTV DNA load monitoring may be helpful for predicting the occurrence of severe nosocomial infections and mortality in critically ill COVID-19 patients.


Subject(s)
COVID-19 , DNA Virus Infections , Torque teno virus , Viral Load , Aged , Critical Illness , DNA, Viral , Humans , SARS-CoV-2 , Torque teno virus/genetics
6.
Transpl Infect Dis ; 24(1): e13771, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34921747

ABSTRACT

BACKGROUND: Increasing evidence suggests that infection with the nonpathogenic human pegivirus type 1 (HPgV-1) exerts a clinical benefit in human immunodeficiency virus (HIV) patients, which could be attributable to immunomodulatory effects. Whether this impact can be extrapolated to kidney transplantation (KT) remains largely unknown. METHODS: We measured plasma HPgV-1 RNA by real-time polymerase chain reaction targeting the 5' untranslated region at various points (pretransplantation, day 7, months 1, 3, 6, and 12) in 199 KT recipients. Study outcomes included posttransplant serious infection, immunosuppression-related adverse event (opportunistic infection and/or de novo cancer), and acute graft rejection. RESULTS: HPgV-1 infection was demonstrated in 52 (26.1%) patients, with rates increasing from 14.7% at baseline to 19.1% by month 12 (p-value = .071). De novo infection occurred in 13.8% of patients with no detectable HPgV-1 RNA before transplantation. Double-organ (liver-kidney or kidney-pancreas) transplantation (odds ratio [OR]: 5.62; 95% confidence interval [CI]: 1.52-20.82) and donation after brain death (OR: 2.21; 95% CI: 1.00-4.88) were associated with posttransplant HPgV-1 infection, whereas pretransplant hypertension was protective (OR: 0.23; 95% CI: 0.09-0.55). There were no significant differences in the incidence of study outcomes according to HPgV-1 status. Plasma HPgV-1 RNA levels at different points did not significantly differ between patients that subsequently developed outcomes and those remaining free from these events. No correlation between HPgV-1 RNA and immune parameters or torque teno virus DNA load was observed either. CONCLUSION: Unlike patients living with HIV, HPgV-1 infection does not seem to influence patient or graft outcomes after KT.


Subject(s)
Flaviviridae Infections , GB virus C , Kidney Transplantation , Humans , Kidney Transplantation/adverse effects , Kinetics , Transplant Recipients
7.
J Med Virol ; 93(4): 2301-2306, 2021 04.
Article in English | MEDLINE | ID: mdl-33236799

ABSTRACT

Assessment of commercial severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) immunoassays for their capacity to provide reliable information on sera neutralizing activity is an emerging need. We evaluated the performance of two commercially available lateral flow immunochromatographic assays (LFIC; Wondfo SARS-CoV-2 Antibody test and the INNOVITA 2019-nCoV Ab test) in comparison with a SARS-CoV-2 neutralization pseudotyped assay for coronavirus disease 2019 (COVID-19) diagnosis in hospitalized patients and investigate whether the intensity of the test band in LFIC associates with neutralizing antibody (NtAb) titers. Ninety sera were included from 51 patients with moderate to severe COVID-19. A green fluorescent protein (GFP) reporter-based pseudotyped neutralization assay (vesicular stomatitis virus coated with SARS-CoV-2 spike protein) was used. Test line intensity was scored using a 4-level scale (0 to 3+). The overall sensitivity of LFIC assays was 91.1% for the Wondfo SARS-CoV-2 Antibody test, 72.2% for the INNOVITA 2019-nCoV IgG, 85.6% for the INNOVITA 2019-nCoV IgM, and 92.2% for the NtAb assay. Sensitivity increased for all assays in sera collected beyond day 14 after symptoms onset (93.9%, 79.6%, 93.9%, and 93.9%, respectively). Reactivities equal to or more intense than the positive control line (≥2+) in the Wondfo assay had a negative predictive value of 100% and a positive predictive value of 96.4% for high NtAb50 titers (≥1/160). Our findings support the use of LFIC assays evaluated herein, particularly the Wondfo test, for COVID-19 diagnosis. We also find evidence that these rapid immunoassays can be used to predict high SARS-CoV-2-S NtAb50 titers.


Subject(s)
Antibodies, Neutralizing/blood , COVID-19 Testing/methods , COVID-19/immunology , Immunoassay/methods , SARS-CoV-2/immunology , Antibodies, Neutralizing/immunology , Antibodies, Viral/blood , Antibodies, Viral/immunology , COVID-19/blood , COVID-19/diagnosis , COVID-19/virology , Green Fluorescent Proteins , Humans , Immunoglobulin G/blood , Immunoglobulin M/blood , Spike Glycoprotein, Coronavirus/immunology
8.
Clin Microbiol Infect ; 27(3): 472.e7-472.e10, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33189872

ABSTRACT

OBJECTIVES: To our knowledge no previous study has assessed the performance of a rapid antigen diagnostic immunoassay (RAD) conducted at the point of care (POC). We evaluated the Panbio™ COVID-19 Ag Rapid Test Device for diagnosis of coronavirus 2019 disease (COVID-19) in symptomatic patients (n = 412) attending primary healthcare centres. METHODS: RAD was performed immediately after sampling following the manufacturer's instructions (reading at 15 min). RT-PCRs were carried out within 24 h of specimen collection. Samples displaying discordant results were processed for culture in Vero E6 cells. Presence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in cell cultures was confirmed by RT-PCR. RESULTS: Out of 412 patients, 43 (10.4%) tested positive by RT-PCR and RAD, and 358 (86.9%) tested negative by both methods; discordant results (RT-PCR+/RAD-) were obtained in 11 patients (2.7%). Overall specificity and sensitivity of rapid antigen detection (RAD) was 100% (95%CI 98.7-100%) and 79.6% (95%CI 67.0-88.8%), respectively, taking RT-PCR as the reference. Overall RAD negative predictive value for an estimated prevalence of 5% and 10% was 99% (95%CI 97.4-99.6%) and 97.9% (95%CI 95.9-98.9), respectively. SARS-CoV-2 could not be cultured from specimens yielding RT-PCR+/RAD- results (n = 11). CONCLUSION: The Panbio™ COVID-19 Ag Rapid Test Device performed well as a POC test for early diagnosis of COVID-19 in primary healthcare centres. More crucially, the data suggested that patients with RT-PCR-proven COVID-19 testing negative by RAD are unlikely to be infectious.


Subject(s)
COVID-19 Serological Testing/methods , COVID-19/diagnosis , Point-of-Care Testing , SARS-CoV-2/isolation & purification , Adolescent , Adult , Aged , Aged, 80 and over , Ambulatory Care Facilities , Antigens, Viral/analysis , COVID-19 Nucleic Acid Testing , Child , Child, Preschool , Early Diagnosis , Female , Humans , Immunoassay , Infant , Male , Middle Aged , Nasopharynx/virology , Reagent Kits, Diagnostic , SARS-CoV-2/genetics , SARS-CoV-2/immunology , Sensitivity and Specificity , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...