Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Publication year range
1.
Arch. cardiol. Méx ; Arch. cardiol. Méx;94(2): 219-239, Apr.-Jun. 2024. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1556919

ABSTRACT

resumen está disponible en el texto completo


Abstract This consensus of nomenclature and classification for congenital bicuspid aortic valve and its aortopathy is evidence-based and intended for universal use by physicians (both pediatricians and adults), echocardiographers, advanced cardiovascular imaging specialists, interventional cardiologists, cardiovascular surgeons, pathologists, geneticists, and researchers spanning these areas of clinical and basic research. In addition, as long as new key and reference research is available, this international consensus may be subject to change based on evidence-based data1.

2.
Arch Cardiol Mex ; 94(2): 219-239, 2024 02 07.
Article in Spanish | MEDLINE | ID: mdl-38325117

ABSTRACT

This consensus of nomenclature and classification for congenital bicuspid aortic valve and its aortopathy is evidence-based and intended for universal use by physicians (both pediatricians and adults), echocardiographers, advanced cardiovascular imaging specialists, interventional cardiologists, cardiovascular surgeons, pathologists, geneticists, and researchers spanning these areas of clinical and basic research. In addition, as long as new key and reference research is available, this international consensus may be subject to change based on evidence-based data1.


Este consenso de nomenclatura y clasificación para la válvula aórtica bicúspide congénita y su aortopatía está basado en la evidencia y destinado a ser utilizado universalmente por médicos (tanto pediatras como de adultos), médicos ecocardiografistas, especialistas en imágenes avanzadas cardiovasculares, cardiólogos intervencionistas, cirujanos cardiovasculares, patólogos, genetistas e investigadores que abarcan estas áreas de investigación clínica y básica. Siempre y cuando se disponga de nueva investigación clave y de referencia, este consenso internacional puede estar sujeto a cambios de acuerdo con datos basados en la evidencia1.

3.
EuroIntervention ; 11(1): 75-84, 2015 May.
Article in English | MEDLINE | ID: mdl-25868876

ABSTRACT

AIMS: This study aimed to evaluate the safety and performance of the TriGuard™ Embolic Deflection Device (EDD), a nitinol mesh filter positioned in the aortic arch across all three major cerebral artery take-offs to deflect emboli away from the cerebral circulation, in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: The prospective, multicentre DEFLECT I study (NCT01448421) enrolled 37 consecutive subjects undergoing TAVR with the TriGuard EDD. Subjects underwent clinical and cognitive follow-up to 30 days; cerebral diffusion-weighted magnetic resonance imaging (DW-MRI) was performed pre-procedure and at 4±2 days post procedure. The device performed as intended with successful cerebral coverage in 80% (28/35) of cases. The primary safety endpoint (in-hospital EDD device- or EDD procedure-related cardiovascular mortality, major stroke disability, life-threatening bleeding, distal embolisation, major vascular complications, or need for acute cardiac surgery) occurred in 8.1% of subjects (VARC-defined two life-threatening bleeds and one vascular complication). The presence of new cerebral ischaemic lesions on post-procedure DW-MRI (n=28) was similar to historical controls (82% vs. 76%, p=NS). However, an exploratory analysis found that per-patient total lesion volume was 34% lower than reported historical data (0.2 vs. 0.3 cm3), and 89% lower in patients with complete (n=17) versus incomplete (n=10) cerebral vessel coverage (0.05 vs. 0.45 cm3, p=0.016). CONCLUSIONS: Use of the first-generation TriGuard EDD during TAVR is safe, and device performance was successful in 80% of cases during the highest embolic-risk portions of the TAVR procedure. The potential of the TriGuard EDD to reduce total cerebral ischaemic burden merits further randomised investigation.


Subject(s)
Aortic Valve Stenosis/therapy , Aortic Valve , Cardiac Catheterization/instrumentation , Embolic Protection Devices , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Intracranial Embolism/prevention & control , Aged , Aged, 80 and over , Alloys , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Brain Ischemia/etiology , Brain Ischemia/prevention & control , Brazil , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Cardiac Catheterization/mortality , Cognition , Cognition Disorders/etiology , Cognition Disorders/prevention & control , Diffusion Magnetic Resonance Imaging , Europe , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/mortality , Humans , Intracranial Embolism/diagnosis , Intracranial Embolism/etiology , Intracranial Embolism/mortality , Male , Predictive Value of Tests , Prospective Studies , Prosthesis Design , Risk Factors , Severity of Illness Index , Stroke/etiology , Stroke/prevention & control , Time Factors , Treatment Outcome , Ultrasonography, Doppler, Transcranial
SELECTION OF CITATIONS
SEARCH DETAIL