Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 661
Filter
1.
Am Heart J ; 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38838970

ABSTRACT

BACKGROUND: The impact of prosthesis-patient mismatch (PPM) on major endpoints after transcatheter aortic valve replacement (TAVR) is controversial and the effects on progression of heart damage are poorly investigated. Therefore, our study aims to evaluate the prevalence and predictors of PPM in a "real world" cohort of patients at intermediate and low surgical risk, its impact on mortality and the clinical-echocardiographic progression of heart damage. METHODS: 963 patients who underwent TAVR procedure between 2017 and 2021, from the RECOVERY-TAVR international multicenter observational registry, were included in this analysis. Multiparametric echocardiographic data of these patients were analyzed at 1-year follow-up (FU). Clinical and echocardiographic features were stratified by presence of PPM and PPM severity, as per the most current international recommendations, using VARC-3 criteria. RESULTS: 18% of patients developed post-TAVR. PPM, and 7.7% of the whole cohort had severe PPM. At baseline, 50.3% of patients with PPM were male (vs 46.2% in the cohort without PPM, p=0.33), aged 82 (IQR 79-85y) years vs 82 (IQR 78-86 p=0.46), and 55.6% had Balloon-Expandable valves implanted (vs 46.8% of patients without PPM, p=0.04); they had smaller left ventricular outflow tract (LVOT) diameter (20 mm, IQR 19-21 vs 20 mm, IQR 20-22, p=0.02), reduced SVi (34.2 vs 38 ml/m2, p<0.01) and transaortic flow rate (190.6 vs 211 ml/s, p<0.01). At pre-discharge FU patients with PPM had more paravalvular aortic regurgitation (moderate-severe AR 15.8% vs 9.2%, p<0.01). At 1-year FU, maladaptive alterations of left ventricular parameters were found in patients with PPM, with a significant increase in end-systolic diameter (33 mm vs 28 mm, p=0.03) and a significant increase in left ventricle end systolic indexed volume in those with moderate and severe PPM (52 IQR 42-64 and 52, IQR 41-64 vs.44 IQR 35-59 in those without, p=0.02)). No evidence of a significant impact of PPM on overall (p=0.71) and CV (p=0.70) mortality was observed. Patients with moderate/severe PPM had worse NYHA functional class at 1 year (NYHA III-IV 13% vs 7.8%, p=0.03). Prosthesis size≤23 mm (OR 11.6, 1.68-80.1) was an independent predictor of PPM, while SVi (OR 0.87, 0.83-0.91, p<0.001) and LVOT diameter (OR 0.79, 0.65-0.95, p=0.01) had protective effect. CONCLUSIONS: PPM was observed in 18% of patients undergoing TAVR. Echocardiographic evaluations demonstrated a PPM-related pattern of early ventricular maladaptive alterations, possibly precursor to a reduction in cardiac function, associated with a significant deterioration in NYHA class at 1 year. These findings emphasize the importance of prevention of PPM of any grade in patients undergoing TAVR procedure, especially in populations at risk.

2.
Article in English, Spanish | MEDLINE | ID: mdl-38844072

ABSTRACT

INTRODUCTION AND OBJECTIVES: There is limited evidence to identify the most accurate method for measuring the mitral valve area (MVA) after percutaneous edge-to-edge mitral repair. Our objective was to evaluate the optimal method in this context and its correlation with the mean transmitral gradient. METHODS: A registry of patients undergoing percutaneous mitral repair was conducted, analyzing different methods of measuring MVA and their correlation with the mean gradient. RESULTS: We analyzed data from 167 patients. The mean age was 76 ± 10.3 years, 54% were men, and 46% were women. Etiology was degenerative in 45%, functional in 39%, and mixed in 16%. Postclip MVA measurements were 1.89 ± 0.60 cm2 using pressure half-time (PHT), 2.87 ± 0.83 cm2 using 3D planimetry, and the mean gradient was 3 ± 1.19 mmHg. MVA using 3D planimetry showed a stronger correlation with the mean gradient (r = 0.46, P < .001) than MVA obtained by PHT (r = 0.19, P = .048). Interobserver agreement was also higher with 3D planimetry than with PHT (intraclass correlation coefficient of 0.90 vs 0.81 and variation coefficient of 9.6% vs 19.7%, respectively). CONCLUSIONS: Our study demonstrates that the PHT method significantly underestimates MVA after clip implantation compared with direct measurement using transesophageal 3D planimetry. The latter method also correlates better with postimplantation gradients and has less interobserver variability. These results suggest that 3D planimetry is a more appropriate method for assessing postclip mitral stenosis.

3.
Article in English | MEDLINE | ID: mdl-38752971

ABSTRACT

BACKGROUND: The safety profile of transcatheter tricuspid valve (TTV) repair techniques is well established, but residual tricuspid regurgitation (TR) remains a concern. OBJECTIVES: The authors sought to assess the impact of residual TR severity post-TTV repair on survival. METHODS: We evaluated the survival rate at 2 years of 613 patients with severe isolated functional TR who underwent TTV repair in TRIGISTRY according to the severity of residual TR at discharge using a 3-grade (mild, moderate, and severe) or 4-grade scheme (mild, mild to moderate, moderate to severe, and severe). RESULTS: Residual TR was none/mild in 33%, moderate in 52%, and severe in 15%. The 2-year adjusted survival rates significantly differed between the 3 groups (85%, 70%, and 44%, respectively; restricted mean survival time [RMST]: P = 0.0001). When the 319 patients with moderate residual TR were subdivided into mild to moderate (n = 201, 33%) and moderate to severe (n = 118, 19%), the adjusted survival rate was also significantly different between groups (85%, 80%, 55%, and 44%, respectively; RMST: P = 0.001). Survival was significantly lower in patients with moderate to severe residual TR compared to patients with mild to moderate residual TR (P = 0.006). No difference in survival rates was observed between patients with no/mild and mild to moderate residual TR (P = 0.67) or between patients with moderate to severe and severe residual TR (P = 0.96). CONCLUSIONS: The moderate residual TR group was heterogeneous and encompassed patients with markedly different clinical outcomes. Refining TR grade classification with a more granular 4-grade scheme improved outcome prediction. Our results highlight the importance of achieving a mild to moderate or lower residual TR grade during TTV repair, which could define a successful intervention.

4.
Article in English, Spanish | MEDLINE | ID: mdl-38763211

ABSTRACT

INTRODUCTION AND OBJECTIVES: In patients undergoing percutaneous coronary intervention (PCI) in the workup for transcatheter aortic valve replacement (TAVR), the clinical impact of coronary revascularization complexity remains largely unknown. This study sought to examine the impact of PCI complexity on clinical outcomes after TAVR in patients undergoing PCI in the preprocedural workup. METHODS: This was a multicenter study including consecutive patients scheduled for TAVR with concomitant significant coronary artery disease. Complex PCI was defined as having at least 1 of the following features: 3 vessels treated, ≥ 3 stents implanted, ≥ 3 lesions treated, bifurcation with 2 stents implanted, total stent length > 60 mm, or chronic total occlusion. The rates of major adverse cardiac events (MACE), including cardiovascular mortality, myocardial infarction, and coronary revascularization were evaluated. RESULTS: A total of 1550 patients were included, of which 454 (29.3%) underwent complex PCI in the pre-TAVR workup. After a median follow-up period of 2 [1-3] years after TAVR, the incidence of MACE was 9.6 events per 100 patients-years. Complex PCI significantly increased the risk of cardiovascular death (HR, 1.44; 95%CI, 1.01-2.07), nonperiprocedural myocardial infarction (HR, 1.52; 95%CI, 1.04-2.21), and coronary revascularization (HR, 2.46; 95%CI, 1.44-4.20). In addition, PCI complexity was identified as an independent predictor of MACE after TAVR (HR, 1.44; 95%CI, 1.09-1.83; P = .009). CONCLUSIONS: In TAVR candidates with significant coronary artery disease requiring percutaneous treatment, complex revascularization was associated with a higher risk of MACE. The degree of procedural complexity should be considered a strong determinant of prognosis in the PCI-TAVR population.

5.
EuroIntervention ; 20(10): e656-e668, 2024 May 20.
Article in English | MEDLINE | ID: mdl-38776142

ABSTRACT

BACKGROUND: Coronary calcification negatively impacts optimal stenting. Intravascular lithotripsy (IVL) is a new calcium modification technique. AIMS: We aimed to assess the impact of different calcium morphologies on IVL efficacy. METHODS: This was a prospective, multicentre study (13 tertiary referral centres). Optical coherence tomography (OCT) was performed before and after IVL, and after stenting. OCT-defined calcium morphologies were concentric (mean calcium arc >180°) and eccentric (mean calcium arc ≤180°). The primary outcomes were angiographic success (residual stenosis <20%) and the presence of fracture by OCT in concentric versus eccentric lesions. RESULTS: Ninety patients were included with a total of 95 lesions: 47 concentric and 48 eccentric. The median number of pulses was 60 (p=1.00). Following IVL, the presence of fracture was not statistically different between groups (79.0% vs 66.0% for concentric vs eccentric; p=0.165). The number of fractures/lesion (4.2±4.4 vs 2.3±2.8; p=0.018) and ≥3 fractures/lesion (57.1% vs 34.0%; p=0.029) were more common in concentric lesions. Angiographic success was numerically but not statistically higher in the concentric group (87.0% vs 76.6%; p=0.196). By OCT, no differences were noted in final minimum lumen area (5.9±2.2 mm2 vs 6.2±2.1 mm2; p=0.570), minimum stent area (5.9±2.2 mm² vs 6.25±2.4 mm2; p=0.483), minimum stent expansion (80.9±16.7% vs 78.2±19.8%), or stent expansion at the maximum calcium site (100.6±24.2% vs 95.8±27.3%) (p>0.05 for all comparisons of concentric vs eccentric, respectively). Calcified nodules were found in 29.5% of lesions; these were predominantly non-eruptive (57%). At the nodule site, dissection was more common than fracture with stent expansion of 103.6±27.2%. CONCLUSIONS: In this prospective, multicentre study, the effectiveness of IVL followed by stenting was not significantly affected by coronary calcium morphology.


Subject(s)
Coronary Angiography , Coronary Artery Disease , Lithotripsy , Tomography, Optical Coherence , Vascular Calcification , Humans , Lithotripsy/methods , Male , Female , Middle Aged , Aged , Prospective Studies , Vascular Calcification/diagnostic imaging , Vascular Calcification/therapy , Treatment Outcome , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Stents , Percutaneous Coronary Intervention/methods , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Calcium
6.
J Clin Invest ; 2024 May 02.
Article in English | MEDLINE | ID: mdl-38696257

ABSTRACT

We describe a previously-unappreciated role for Bruton's tyrosine kinase (BTK) in fungal immune surveillance against aspergillosis, an unforeseen complication of BTK inhibitors (BTKi) used for treating B-cell lymphoid malignancies. We studied BTK-dependent fungal responses in neutrophils from diverse populations, including healthy donors, BTKi-treated patients, and X-linked agammaglobulinemia patients. Upon fungal exposure, BTK was activated in human neutrophils in a TLR2-, Dectin-1-, and FcγR-dependent manner, triggering the oxidative burst. BTK inhibition selectively impeded neutrophil-mediated damage to Aspergillus hyphae, primary granule release, and the fungus-induced oxidative burst by abrogating NADPH oxidase subunit p40phox and GTPase RAC2 activation. Moreover, neutrophil-specific Btk deletion in mice enhanced aspergillosis susceptibility by impairing neutrophil function, not recruitment or lifespan. Conversely, GM-CSF partially mitigated these deficits by enhancing p47phox activation. Our findings underline the crucial role of BTK signaling in neutrophils for antifungal immunity and provide a rationale for GM-CSF use to offset these deficits in susceptible patients.

7.
Article in English | MEDLINE | ID: mdl-38736245

ABSTRACT

BACKGROUND: Malnutrition is associated with poor prognosis in several cardiovascular diseases; however, its role in patients with secondary mitral regurgitation (SMR) is poorly known. AIMS: To evaluate the impact of nutritional status, assessed using different scores, on clinical outcomes in patients with SMR undergoing transcatheter edge-to-edge repair (TEER) in a real-world setting. METHODS: A total of 658 patients with SMR and complete nutritional data were identified from the MIVNUT registry. Nutritional status has been assessed using controlling nutritional status index (CONUT), prognostic nutritional index (PNI), and geriatric nutritional risk index (GNRI) scores. Outcomes of interest were all-cause mortality and all-cause mortality or heart failure (HF) hospitalization. RESULTS: Any malnutrition grade was observed in 79.4%, 16.7%, and 47.9% of patients by using CONUT, PNI, and GNRI, respectively, while moderate to severe malnutrition was noted in 24.7%, 16.7%, and 25.6% of patients, respectively. At a median follow-up of 2.2 years, 212 patients (32.2%) died. Moderate-severe malnutrition was associated with a higher rate of all-cause mortality (HR: 2.46 [95% CI: 1.69-3.58], HR: 2.18 [95% CI: 1.46-3.26], HR: 1.97 [95% CI: 1.41-2.74] for CONUT, PNI, and GNRI scores, respectively). The combined secondary endpoint of all-cause mortality and HF rehospitalization occurred in 306 patients (46.5%). Patients with moderate-severe malnutrition had a higher risk of the composite endpoint (HR: 1.56 [95% CI: 1.20-2.28], HR: 1.55 [95% CI: 1.01-2.19], HR: 1.36 [95% CI: 1.02-1.80] for CONUT, PNI, and GNRI scores, respectively). After adjustment for multiple confounders, moderate-severe malnutrition remained independently associated with clinical outcomes. CONCLUSIONS: Moderate-severe malnutrition was common in patients with SMR undergoing TEER. It was independently associated with poor prognosis regardless of the different scores used.

8.
Article in English | MEDLINE | ID: mdl-38795093

ABSTRACT

BACKGROUND: Left atrial appendage occlusion (LAAO) provides mechanical cardioembolic protection for atrial fibrillation (AF) patients who cannot use oral anticoagulation therapy (OAT). Patients with a thrombotic event despite OAT are at high risk for recurrence and may also benefit from LAAO. OBJECTIVES: This study sought to investigate the efficacy of LAAO in AF patients with a thrombotic event on OAT compared to: 1) LAAO in AF patients with a contraindication for OAT; and 2) historical data. METHODS: The international LAAO after stroke despite oral anticoagulation (STR-OAC LAAO) collaboration included patients who underwent LAAO because of thrombotic events on OAT. This cohort underwent propensity score matching and was compared to the EWOLUTION (Evaluating Real-Life Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology) registry, which represents patients who underwent LAAO because of OAT contraindications. The primary outcome was ischemic stroke. Event rates were compared between cohorts and with historical data without OAT, yielding relative risk reductions based on risk scores. RESULTS: Analysis of 438 matched pairs revealed no significant difference in the ischemic stroke rate between the STR-OAC LAAO and EWOLUTION cohorts (2.5% vs 1.9%; HR: 1.37; 95% CI: 0.72-2.61). STR-OAC LAAO patients exhibited a higher thromboembolic risk (HR: 1.71; 95% CI: 1.04-2.83) but lower bleeding risk (HR: 0.39; 95% CI: 0.18-0.88) compared to EWOLUTION patients. The mortality rate was slightly higher in EWOLUTION (4.3% vs 6.9%; log-rank P = 0.028). Relative risk reductions for ischemic stroke were 70% and 78% in STR-OAC LAAO and EWOLUTION, respectively, compared to historical data without OAT. CONCLUSIONS: LAAO in patients with a thrombotic event on OAT demonstrated comparable stroke rates to the OAT contraindicated population in EWOLUTION. The thromboembolic event rate was higher and the bleeding rate lower, reflecting the intrinsically different risk profile of both populations. Until randomized trials are available, LAAO may be considered in patients with an ischemic event on OAT.

9.
medRxiv ; 2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38712043

ABSTRACT

Background: Topical corticosteroids (TCS) are first-line therapies for numerous skin conditions. Topical Steroid Withdrawal (TSW) is a controversial diagnosis advocated by patients with prolonged TCS exposure who report severe systemic reactions upon treatment cessation. However, to date there have been no systematic clinical or mechanistic studies to distinguish TSW from other eczematous disorders. Methods: A re-analysis of a previous survey with eczematous skin disease was performed to evaluate potential TSW distinguishing symptoms. We subsequently conducted a pilot study of 16 patients fitting the proposed diagnostic criteria. We then performed: tissue metabolomics, transcriptomics, and immunostaining on skin biopsies; serum metabolomics and cytokine assessments; shotgun metagenomics on microbiome skin swabs; genome sequencing; followed by functional, mechanistic studies using human skin cell lines and mice. Results: Clinically distinct TSW symptoms included burning, flushing, and thermodysregulation. Metabolomics and transcriptomics both implicated elevated NAD+ oxidation stemming from increased expression of mitochondrial complex I and conversion of tryptophan into kynurenine metabolites. These abnormalities were induced by glucocorticoid exposure both in vitro and in a cohort of healthy controls (N=19) exposed to TCS. Targeting complex I via either metformin or the herbal compound berberine improved outcomes in both cell culture and in an open-label case series for patients with TSW. Conclusion: Taken together, our results suggest that TSW has a distinct dermatopathology. While future studies are needed to validate these results in larger cohorts, this work provides the first mechanistic evaluation into TSW pathology, and offers insights into clinical identification, pharmacogenomic candidates, and directed therapeutic strategies.

10.
EuroIntervention ; 20(8): e487-e495, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38629416

ABSTRACT

BACKGROUND: Data on the likelihood of left ventricle (LV) recovery in patients with severe LV dysfunction and severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) and its prognostic value are limited. AIMS: We aimed to assess the likelihood of LV recovery following TAVI, examine its association with midterm mortality, and identify independent predictors of LV function. METHODS: In our multicentre registry of 17 TAVI centres in Western Europe and Israel, patients were stratified by baseline LV function (ejection fraction [EF] >/≤30%) and LV response: no LV recovery, LV recovery (EF increase ≥10%), and LV normalisation (EF ≥50% post-TAVI). RESULTS: Our analysis included 10,872 patients; baseline EF was ≤30% in 914 (8.4%) patients and >30% in 9,958 (91.6%) patients. The LV recovered in 544 (59.5%) patients, including 244 (26.7%) patients whose LV function normalised completely (EF >50%). Three-year mortality for patients without severe LV dysfunction at baseline was 29.4%. Compared to this, no LV recovery was associated with a significant increase in mortality (adjusted hazard ratio 1.32; p<0.001). Patients with similar LV function post-TAVI had similar rates of 3-year mortality, regardless of their baseline LV function. Three variables were associated with a higher likelihood of LV recovery following TAVI: no previous myocardial infarction (MI), estimated glomerular filtration rate >60 mL/min, and mean aortic valve gradient (mAVG) (expressed either as a continuous variable or as a binary variable using the standard low-flow, low-gradient aortic stenosis [AS] definition). CONCLUSIONS: LV recovery following TAVI and the extent of this recovery are major determinants of midterm mortality in patients with severe AS and severe LV dysfunction undergoing TAVI. Patients with no previous MI and those with an mAVG >40 mmHg show the best results following TAVI, which are at least equivalent to those for patients without severe LV dysfunction. (ClinicalTrials.gov: NCT04031274).


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Ventricular Dysfunction, Left , Humans , Aortic Valve/surgery , Heart Ventricles , Stroke Volume , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Ventricular Function, Left , Multicenter Studies as Topic , Clinical Studies as Topic
11.
Nutrients ; 16(6)2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38542709

ABSTRACT

According to the latest data, Spain (19.4%) and Portugal (21.8%) are the two European countries with the highest percentage of older adults. Concerns about diet quality are increasing, especially among institutionalized older people, who are at the greatest risk of malnutrition. To assess the adequacy of dietary intake of 186 older adults (>65 y) institutionalized in public nursing homes (NH) in Galicia (Northwest Spain) and the Porto district (Northern Portugal), a cross-sectional study has been carried out. The double-weighing method and a country-specific food composition database were employed for nutritional assessment. Nutritional adequacy was assessed based on the recommendations of the EFSA and WHO. Caloric intake in Spanish NHs was higher than in Portuguese facilities; 20.3% and 35.8% of Spanish and Portuguese residents, respectively, had a protein intake below the EFSA recommendation, and 46.2% and 44.9% of residents in Portugal and Spain, respectively, had lipid intakes below the reference intake range. Further, 45.5% of the residents in Portugal and 66.9% in Spain had a carbohydrate intake within the recommended range. Salt intake was higher than the recommendation for 67.0% and 32.3% of the residents in Spain and Portugal, respectively. This study supports the notion that institutionalized older adults are prone to significant nutritional inadequacies.


Subject(s)
Diet , Malnutrition , Humans , Aged , Cross-Sectional Studies , Energy Intake , Nutrition Assessment , Nursing Homes , Spain , Nutritional Status
12.
PLoS One ; 19(3): e0299687, 2024.
Article in English | MEDLINE | ID: mdl-38512973

ABSTRACT

Phytotherapy is an attractive strategy to treat inflammatory bowel disease (IBD) that could be especially useful in developing countries. We previously demonstrated the intestinal anti-inflammatory effect of the total ethereal extract from the Physalis peruviana (Cape gooseberry) calyces in TNBS-induced colitis. This work investigates the therapeutic potential of Peruviose A and B, two sucrose esters that constitute the major metabolites of its calyces. The effect of the Peruvioses A and B mixture on TNBS-induced colitis was studied after 3 (preventive) and 15-days (therapy set-up) of colitis induction in rats. Colonic inflammation was assessed by measuring macroscopic/histologic damage, MPO activity, and biochemical changes. Additionally, LPS-stimulated RAW 264.7 macrophages were treated with test compounds to determine the effect on cytokine imbalance in these cells. Peruvioses mixture ameliorated TNBS-induced colitis in acute (preventive) or established (therapeutic) settings. Although 3-day treatment with compounds did not produce a potent effect, it was sufficient to significantly reduce the extent/severity of tissue damage and the microscopic disturbances. Beneficial effects in the therapy set-up were substantially higher and involved the inhibition of pro-inflammatory enzymes (iNOS, COX-2), cytokines (TNF-α, IL-1ß, and IL-6), as well as epithelial regeneration with restoration of goblet cells numbers and expression of MUC-2 and TFF-3. Consistently, LPS-induced RAW 264.7 cells produced less NO, PGE2, TNF-α, IL-6, and MCP-1. These effects might be related to the inhibition of the NF-κB signaling pathway. Our results suggest that sucrose esters from P. peruviana calyces, non-edible waste from fruit production, might be useful as an alternative IBD treatment.


Subject(s)
Colitis , Inflammatory Bowel Diseases , Physalis , Ribes , Rats , Animals , Tumor Necrosis Factor-alpha/metabolism , Esters/metabolism , Sucrose/metabolism , Interleukin-6/metabolism , Lipopolysaccharides/pharmacology , Colitis/chemically induced , Colitis/drug therapy , Colitis/metabolism , Cytokines/metabolism , Colon/pathology , Inflammatory Bowel Diseases/pathology , Trinitrobenzenesulfonic Acid/toxicity
13.
Eur Heart J ; 45(21): 1904-1916, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38554125

ABSTRACT

BACKGROUND AND AIMS: There is significant potential to streamline the clinical pathway for patients undergoing transcatheter aortic valve implantation (TAVI). The purpose of this study was to evaluate the effect of implementing BENCHMARK best practices on the efficiency and safety of TAVI in 28 sites in 7 European countries. METHODS: This was a study of patients with severe symptomatic aortic stenosis (AS) undergoing TAVI with balloon-expandable valves before and after implementation of BENCHMARK best practices. Principal objectives were to reduce hospital length of stay (LoS) and duration of intensive care stay. Secondary objective was to document patient safety. RESULTS: Between January 2020 and March 2023, 897 patients were documented prior to and 1491 patients after the implementation of BENCHMARK practices. Patient characteristics were consistent with a known older TAVI population and only minor differences. Mean LoS was reduced from 7.7 ± 7.0 to 5.8 ± 5.6 days (median 6 vs. 4 days; P < .001). Duration of intensive care was reduced from 1.8 to 1.3 days (median 1.1 vs. 0.9 days; P < .001). Adoption of peri-procedure best practices led to increased use of local anaesthesia (96.1% vs. 84.3%; P < .001) and decreased procedure (median 47 vs. 60 min; P < .001) and intervention times (85 vs. 95 min; P < .001). Thirty-day patient safety did not appear to be compromised with no differences in all-cause mortality (0.6% in both groups combined), stroke/transient ischaemic attack (1.4%), life-threatening bleeding (1.3%), stage 2/3 acute kidney injury (0.7%), and valve-related readmission (1.2%). CONCLUSIONS: Broad implementation of BENCHMARK practices contributes to improving efficiency of TAVI pathway reducing LoS and costs without compromising patient safety.


Subject(s)
Aortic Valve Stenosis , Benchmarking , Length of Stay , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Male , Female , Aged, 80 and over , Length of Stay/statistics & numerical data , Aged , Critical Pathways , Europe/epidemiology , Postoperative Complications/epidemiology , Postoperative Complications/prevention & control , Patient Safety
14.
Int Urogynecol J ; 35(5): 1021-1026, 2024 May.
Article in English | MEDLINE | ID: mdl-38520516

ABSTRACT

INTRODUCTION AND HYPOTHESIS: Single-incision slings (SIS) have emerged as a less invasive alternative to conventional slings for stress urinary incontinence (SUI) treatment. However, long-term efficacy and safety results remain uncertain owing to a lack of studies. MATERIAL AND METHODS: A retrospective review of 155 patients treated with Altis® for SUI between February 2012 and June 2017, held in 2022, as a continuation of a prospective study in which all patients (197) were reviewed for 2 years after surgery (1, 6, 12, and 24 months). Preoperative demographic data, comorbidities, and pressure-flow studies were also recorded. Continence status and satisfaction rates were assessed using the International Consultation on Incontinence Questionnaire-short form (ICIQ-SF) and the Patient Global Impression of Improvement (PGI-I) respectively. The assessment in the 2022 retrospective review was performed via a telephone survey. RESULTS: Mean follow-up time after surgery was 85.3 months (82.5-88.1). In 2022, complete continence was present in 75.4% of the patients. The presence of urinary urgency conditioned the ICIQ-SF score (10.9 vs 1.7 points, p < 0.01), with the ICIQ-SF = 0 in 84.5% of the patients with no associated urgency. Satisfaction assessed by the PGI-I was high, with 84.6% of the patients showing improvement. De novo urgency was present in 37,9% of the patients by 2022. Urinary tract infections were the most frequent complication (9.7%), with only 5 documented cases of mesh erosion. CONCLUSIONS: Altis® SIS is a safe and effective device for SUI treatment, with satisfaction rates comparable with those of the conventional slings. Persistence or development of urinary urgency influences the results.


Subject(s)
Patient Satisfaction , Suburethral Slings , Urinary Incontinence, Stress , Humans , Suburethral Slings/adverse effects , Urinary Incontinence, Stress/surgery , Female , Retrospective Studies , Middle Aged , Follow-Up Studies , Treatment Outcome , Aged , Time Factors , Adult
15.
Methods Mol Biol ; 2784: 113-132, 2024.
Article in English | MEDLINE | ID: mdl-38502482

ABSTRACT

Functional genomics and chemical screens can identify and characterize novel cellular factors regulating signaling networks and chemical tools to modulate their function for the treatment of disease. Screening methods have relied primarily on immortalized and/or transformed cancer cell lines, which can limit the generalization of results to more physiologically relevant systems. Most have also relied on immunofluorescence, or on stably expressed recombinant fluorescent proteins, to detect specific protein markers using high-content imaging readouts. In comparison, high-throughput methods to visualize and measure RNA species have been less explored. To address this, we have adapted an isothermal signal amplification chemistry for RNA FISH known as hybridization chain reaction (HCR) to an automated, high-content imaging assay format. We present a detailed protocol for this technique, which we have named high-content HCR (hcHCR). The protocol focuses on the measurement of changes in mRNA abundance at the single-cell level in human primary cells, but it can be applied to a variety of primary cell types and perturbing agents. We anticipate that hcHCR will be most suitable for low- to medium-throughput screening experiments in which changes in transcript abundance are the desired output measure.


Subject(s)
Diagnostic Imaging , RNA , Humans , RNA/genetics , RNA, Messenger/genetics , Nucleic Acid Hybridization , Signal Transduction
16.
J Phys Chem B ; 128(10): 2516-2527, 2024 Mar 14.
Article in English | MEDLINE | ID: mdl-38438957

ABSTRACT

Nanoporous materials are central to the energy and environmental crisis, with key applications in adsorption, separation, and catalysis. While confinement and surface effects on fluids severely confined in their porosity are well documented, the thermal behavior of nanoporous solids subjected to fluid adsorption remains puzzling in many aspects. With striking phenomena such as the so-called rattle effect, through which fluid/solid collisions decrease the overall thermal conductivity, the solid thermal conductivity and, more generally, heat transfer and dispersion in these complex systems challenge classical approaches (e.g., mixing rules including effective medium approaches fail to capture such effects as shown here). In particular, a robust molecular framework to describe the crossover between the decrease in thermal conductivity through the rattle effect in very narrow pores and the increase in thermal conductivity when replacing vacuum with a fluid phase in larger pores is still missing. Here, using a prototypical model of fluid-filled nanoporous materials (a Lennard-Jones phase confined in an all-silica zeolite), we perform a molecular simulation study to shed light on the parameters that govern the rattle effect in nanoporous solids. First, by varying the fluid/fluid, fluid/solid, and solid/solid interaction strengths as well as the fluid number density and mass density, we unravel the ingredients that lead to the essential coupling between fluid adsorption and phonon transport. Second, despite this complex interplay, inspired by pioneering molecular approaches on the rattle effect, we show that all data obey a simple statistical physics model that relies on the change in the speed of sound due to the fluid adsorbed density and the decrease in phonon lifetime due to scattering by fluid molecules. This framework, which provides a simple formalism to rationalize the thermal behavior of this class of solid/fluid composites, points to a decrease in thermal conductivity upon fluid confinement (up to 30% in some cases). Such an effect paves the way for the design of novel applications involving fluids in interaction with nanoporous materials.

17.
JACC Cardiovasc Interv ; 17(5): 681-692, 2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38479968

ABSTRACT

BACKGROUND: The performance of latest iteration transcatheter aortic valve replacement platforms in patients with small aortic anatomy remains underexplored. OBJECTIVES: The aim of this study was to evaluate effectiveness and performance between the self-expanding (SE) Evolut PRO and PRO+ and the balloon-expandable (BE) SAPIEN ULTRA in patients with small aortic annuli. METHODS: Data from the OPERA-TAVI (Comparative Analysis of Evolut PRO vs. SAPIEN 3 ULTRA Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry were used, with 1:1 propensity score matching. Primary endpoints included 1-year effectiveness composite (all-cause mortality, disabling stroke, or heart failure hospitalization) and 30-day device-related (hemodynamic structural valve dysfunction and nonstructural valve dysfunction) outcomes. RESULTS: Among 3,516 patients, 251 matched pairs with aortic annular area <430 mm2 were assessed. The 1-year primary effectiveness outcome did not differ significantly between cohorts (SE 10.8% vs BE 11.2%; P = 0.91). The 30-day device-oriented composite outcome was more favorable in the Evolut PRO group (SE 4.8% vs BE 10.4%; P = 0.027). Notably, SE valve recipients showed higher rates of disabling stroke (SE 4.0% vs BE 0.0%; P < 0.01) and paravalvular leaks (mild or greater: SE 48.5% vs BE 18.6% [P < 0.001]; moderate: SE 4.5% vs BE 1.2% [P = 0.070]). The BE group had higher rates of prosthesis-patient mismatch (moderate or greater: SE 16.0% vs BE 47.1% [P < 0.001]; severe: SE 1.3% vs BE 5.7% [P = 0.197]) and more patients with residual mean gradients >20 mm Hg (SE 1.0% vs BE 13.5%; P < 0.001). CONCLUSIONS: In patients with small aortic annuli, transcatheter aortic valve replacement with latest iteration devices is safe. SE platforms are associated with more favorable device performance in terms of hemodynamic structural and nonstructural dysfunction. Randomized data are needed to validate these findings and guide informed device selection.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Prosthesis Design , Treatment Outcome , Registries , Stroke/etiology
18.
ESC Heart Fail ; 11(2): 1218-1227, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38303542

ABSTRACT

AIMS: Acute mitral regurgitation (MR) in the setting of myocardial infarction (MI) may be the result of papillary muscle rupture (PMR). This condition is associated with high morbidity and mortality. We aim to evaluate the feasibility of transcatheter edge-to-edge mitral valve repair (TEER) in this acute setting. METHODS AND RESULTS: We analysed data from the International Registry of MitraClip in Acute Mitral Regurgitation following acute Myocardial Infarction (IREMMI) of 30 centres in Europe, North America, and the middle east. We included patients with post-MI PMR treated with TEER as a salvage procedure, and we evaluated immediate and 30-day outcomes. Twenty-three patients were included in this analysis (9 patients suffered complete papillary muscle rupture, 9 partial and 5 chordal rupture). The patients' mean age was 68 ± 14 years. Patients were at high surgical risk with median EuroSCORE II 27% (IQR 16, 28) and 20 out of 23 (87% were in cardiogenic shock). All patients were treated with vasopressors, and 17 out of 23 patients required mechanical support. TEER procedure was performed on the median 6 days after the index MI date IQR (3, 11). Procedural success was achieved in 87% of patients. The grade of MR was significantly decreased after the procedure. MR reduction to 0 or 1 + was achieved in 13 patients (57%), to 2 + in 7 patients (30%), P < 0.01. V-Wave was reduced from 49 ± 8 mmHg to 26 ± 10 mmHg post-procedure, P < 0.01. Sixteen out of 23 patients (70%) were discharged from hospital and 5 of them required reintervention with surgical mitral valve replacement. No additional death at 1 year was documented. CONCLUSIONS: TEER is a feasible therapy in critically ill patients with PMR due to a recent MI. TEER may have a role as salvage treatment or bridge to surgery in this population.


Subject(s)
Mitral Valve Insufficiency , Myocardial Infarction , Humans , Middle Aged , Aged , Aged, 80 and over , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Papillary Muscles , Myocardial Infarction/complications , Shock, Cardiogenic/etiology
19.
Am Heart J ; 271: 68-75, 2024 May.
Article in English | MEDLINE | ID: mdl-38401649

ABSTRACT

BACKGROUND: Both transcatheter edge-to-edge repair (TEER) of mitral regurgitation or left atrial appendage closure (LAAC) require periprocedural anticoagulation with unfractionated heparin (UFH) that is administered either before or immediately after transseptal puncture (TSP). The optimal timing of UFH administration (before or after TSP) is unknown. The Strategy To Optimize PeriproCeduraL AnticOagulation in Structural Transseptal Interventions trial (STOP CLOT Trial) was designed to determine if early anticoagulation is effective in reducing ischemic complications without increasing the risk of periprocedural bleeding. METHODS: The STOP CLOT trial is a multicenter, prospective, double-blind, placebo-controlled, randomized trial. A total of 410 patients scheduled for TEER or LAAC will be randomized 1:1 either early UFH administration (iv. bolus of 100 units/kg UFH or placebo, given after obtaining femoral vein access and at least 5 minutes prior to the start of the TSP) or late UFH administration (iv. bolus of 100 units/kg UFH or placebo given immediately after TSP). Prespecified preliminary statistical analysis will be performed after complete follow-up of the first 196 randomized subjects. To ensure blinding, a study nurse responsible for randomization and UFH/placebo preparation is not involved in the care of the patients enrolled into the study. The primary study endpoint is a composite of (1) major adverse cardiac and cerebrovascular events (death, stroke, TIA, myocardial infarction, or peripheral embolization) within 30 days post-procedure, (2) intraprocedural fresh thrombus formation in the right or left atrium as assessed with periprocedural transesophageal echocardiography, or (3) occurrence of new ischemic lesions (diameter ≥4 mm) on brain magnetic resonance imaging performed 2 to 5 days after the procedure. The safety endpoint is the occurrence of moderate or severe bleeding complications during the index hospitalization. CONCLUSIONS: Protocols of periprocedural anticoagulation administration during structural interventions have never been tested in a randomized clinical trial. The Stop Clot trial may help reach consensus on the optimal timing of initiation of periprocedural anticoagulation. CLINICAL TRIALS REGISTRATION NUMBER: The study protocol is registered at ClinicalTrials.gov, identifier NCT05305612.


Subject(s)
Anticoagulants , Atrial Appendage , Cardiac Catheterization , Heparin , Mitral Valve Insufficiency , Female , Humans , Male , Anticoagulants/administration & dosage , Atrial Appendage/surgery , Atrial Appendage/diagnostic imaging , Cardiac Catheterization/methods , Double-Blind Method , Heart Septum/surgery , Heparin/administration & dosage , Mitral Valve Insufficiency/surgery , Prospective Studies , Multicenter Studies as Topic , Randomized Controlled Trials as Topic
20.
Am J Cardiol ; 219: 60-70, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38401656

ABSTRACT

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Male , Female , Aortic Valve Stenosis/surgery , Sex Factors , Aged, 80 and over , Aged , Treatment Outcome , Postoperative Complications/epidemiology , Aortic Valve/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...