Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Language
Publication year range
1.
Braz. j. biol ; 82: 1-6, 2022. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-1468419

ABSTRACT

High doses of antibiotics used in hospitals can affect the microbial composition of sewers, selecting resistant bacteria. In this sense, we evaluated the antibiotic resistance profile and the multiresistant phenotype of bacteria isolated in sewage from a tertiary hospital in the interior São Paulo state, Brazil. For bacteria isolation, 10 µL of sewage samples were sown in selective culture media and the isolates were identified using VITEK-2 automatized system. The antibiotic sensitivity test was performed by disk diffusion. High percentages of resistance were found for amoxicillin, ampicillin, ceftazidime, clindamycin, vancomycin and the multidrug-resistant phenotype (MDR) was attributed to 60.7% of the isolates. Our results show bacteria classified as critical/high priority by WHO List of Priority Pathogens (Enterococcus and Staphylococcus aureus resistant to vancomycin and Enterobacteriaceae resistant to carbapenems) in hospital sewage. Therefore, the implementation of disinfection technologies for hospital sewage would reduce the bacterial load in the sewage that will reach urban wastewater treatment plants, minimizing superficial water contamination and bacterial resistance spread in the environment.


Altas doses de antibióticos utilizados em hospitais podem afetar a composição microbiana dos esgotos, selecionando bactérias resistentes. Nesse sentido, avaliamos o perfil de resistência a antibióticos e o fenótipo multirresistente de bactérias isoladas em esgoto de um hospital terciário no interior do estado de São Paulo, Brasil. Para o isolamento de bactérias, foram semeados 10 µL das amostras de esgoto em meios de cultura seletivos e os isolados foram identificados usando o sistema automatizado VITEK-2. O teste de sensibilidade aos antibióticos foi realizado por disco-difusão em ágar. Elevadas porcentagens de resistência foram encontradas para amoxicilina, ampicilina, ceftazidima, clindamicina, vancomicina e o fenótipo multirresistente (MDR) foi atribuído a 60,7% dos isolados. Nossos resultados mostram bactérias classificadas como prioridade crítica/alta pela Lista de Patógenos Prioritários da OMS (Enterococcus e Staphylococcus aureus resistentes à vancomicina e Enterobacteriaceae resistentes aos carbapenêmicos) no esgoto hospitalar. Sendo assim, implementação de tecnologias de desinfecção do esgoto hospitalar reduziriam a carga bacteriana no esgoto que chegará às estações de tratamento de esgoto urbanas, minimizando a contaminação dos ecossistemas hídricos receptores e a disseminação da resistência bacteriana no ambiente.


Subject(s)
Enterococcus/pathogenicity , Sewage/analysis , Water Microbiology/standards , Water Pollutants, Chemical/analysis , Water Pollutants, Chemical/toxicity , Drug Resistance, Microbial , Staphylococcus aureus/pathogenicity
2.
Braz. j. biol ; 822022.
Article in English | LILACS-Express | LILACS, VETINDEX | ID: biblio-1468606

ABSTRACT

Abstract High doses of antibiotics used in hospitals can affect the microbial composition of sewers, selecting resistant bacteria. In this sense, we evaluated the antibiotic resistance profile and the multiresistant phenotype of bacteria isolated in sewage from a tertiary hospital in the interior São Paulo state, Brazil. For bacteria isolation, 10 µL of sewage samples were sown in selective culture media and the isolates were identified using VITEK-2 automatized system. The antibiotic sensitivity test was performed by disk diffusion. High percentages of resistance were found for amoxicillin, ampicillin, ceftazidime, clindamycin, vancomycin and the multidrug-resistant phenotype (MDR) was attributed to 60.7% of the isolates. Our results show bacteria classified as critical/high priority by WHO List of Priority Pathogens (Enterococcus and Staphylococcus aureus resistant to vancomycin and Enterobacteriaceae resistant to carbapenems) in hospital sewage. Therefore, the implementation of disinfection technologies for hospital sewage would reduce the bacterial load in the sewage that will reach urban wastewater treatment plants, minimizing superficial water contamination and bacterial resistance spread in the environment.


Resumo Altas doses de antibióticos utilizados em hospitais podem afetar a composição microbiana dos esgotos, selecionando bactérias resistentes. Nesse sentido, avaliamos o perfil de resistência a antibióticos e o fenótipo multirresistente de bactérias isoladas em esgoto de um hospital terciário no interior do estado de São Paulo, Brasil. Para o isolamento de bactérias, foram semeados 10 µL das amostras de esgoto em meios de cultura seletivos e os isolados foram identificados usando o sistema automatizado VITEK-2. O teste de sensibilidade aos antibióticos foi realizado por disco-difusão em ágar. Elevadas porcentagens de resistência foram encontradas para amoxicilina, ampicilina, ceftazidima, clindamicina, vancomicina e o fenótipo multirresistente (MDR) foi atribuído a 60,7% dos isolados. Nossos resultados mostram bactérias classificadas como prioridade crítica/alta pela Lista de Patógenos Prioritários da OMS (Enterococcus e Staphylococcus aureus resistentes à vancomicina e Enterobacteriaceae resistentes aos carbapenêmicos) no esgoto hospitalar. Sendo assim, implementação de tecnologias de desinfecção do esgoto hospitalar reduziriam a carga bacteriana no esgoto que chegará às estações de tratamento de esgoto urbanas, minimizando a contaminação dos ecossistemas hídricos receptores e a disseminação da resistência bacteriana no ambiente.

3.
Braz. j. biol ; 82: e234471, 2022. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-1153460

ABSTRACT

High doses of antibiotics used in hospitals can affect the microbial composition of sewers, selecting resistant bacteria. In this sense, we evaluated the antibiotic resistance profile and the multiresistant phenotype of bacteria isolated in sewage from a tertiary hospital in the interior São Paulo state, Brazil. For bacteria isolation, 10 µL of sewage samples were sown in selective culture media and the isolates were identified using VITEK-2 automatized system. The antibiotic sensitivity test was performed by disk diffusion. High percentages of resistance were found for amoxicillin, ampicillin, ceftazidime, clindamycin, vancomycin and the multidrug-resistant phenotype (MDR) was attributed to 60.7% of the isolates. Our results show bacteria classified as critical/high priority by WHO List of Priority Pathogens (Enterococcus and Staphylococcus aureus resistant to vancomycin and Enterobacteriaceae resistant to carbapenems) in hospital sewage. Therefore, the implementation of disinfection technologies for hospital sewage would reduce the bacterial load in the sewage that will reach urban wastewater treatment plants, minimizing superficial water contamination and bacterial resistance spread in the environment.


Altas doses de antibióticos utilizados em hospitais podem afetar a composição microbiana dos esgotos, selecionando bactérias resistentes. Nesse sentido, avaliamos o perfil de resistência a antibióticos e o fenótipo multirresistente de bactérias isoladas em esgoto de um hospital terciário no interior do estado de São Paulo, Brasil. Para o isolamento de bactérias, foram semeados 10 µL das amostras de esgoto em meios de cultura seletivos e os isolados foram identificados usando o sistema automatizado VITEK-2. O teste de sensibilidade aos antibióticos foi realizado por disco-difusão em ágar. Elevadas porcentagens de resistência foram encontradas para amoxicilina, ampicilina, ceftazidima, clindamicina, vancomicina e o fenótipo multirresistente (MDR) foi atribuído a 60,7% dos isolados. Nossos resultados mostram bactérias classificadas como prioridade crítica/alta pela Lista de Patógenos Prioritários da OMS (Enterococcus e Staphylococcus aureus resistentes à vancomicina e Enterobacteriaceae resistentes aos carbapenêmicos) no esgoto hospitalar. Sendo assim, implementação de tecnologias de desinfecção do esgoto hospitalar reduziriam a carga bacteriana no esgoto que chegará às estações de tratamento de esgoto urbanas, minimizando a contaminação dos ecossistemas hídricos receptores e a disseminação da resistência bacteriana no ambiente.


Subject(s)
Sewage , Bacteria/genetics , Phenotype , Brazil , Microbial Sensitivity Tests , Tertiary Care Centers
4.
Braz J Biol ; 82: e234471, 2021.
Article in English | MEDLINE | ID: mdl-33681897

ABSTRACT

High doses of antibiotics used in hospitals can affect the microbial composition of sewers, selecting resistant bacteria. In this sense, we evaluated the antibiotic resistance profile and the multiresistant phenotype of bacteria isolated in sewage from a tertiary hospital in the interior São Paulo state, Brazil. For bacteria isolation, 10 µL of sewage samples were sown in selective culture media and the isolates were identified using VITEK-2 automatized system. The antibiotic sensitivity test was performed by disk diffusion. High percentages of resistance were found for amoxicillin, ampicillin, ceftazidime, clindamycin, vancomycin and the multidrug-resistant phenotype (MDR) was attributed to 60.7% of the isolates. Our results show bacteria classified as critical/high priority by WHO List of Priority Pathogens (Enterococcus and Staphylococcus aureus resistant to vancomycin and Enterobacteriaceae resistant to carbapenems) in hospital sewage. Therefore, the implementation of disinfection technologies for hospital sewage would reduce the bacterial load in the sewage that will reach urban wastewater treatment plants, minimizing superficial water contamination and bacterial resistance spread in the environment.


Subject(s)
Bacteria , Sewage , Bacteria/genetics , Brazil , Microbial Sensitivity Tests , Phenotype , Tertiary Care Centers
5.
J Parasitol ; 99(6): 1144-7, 2013 Dec.
Article in English | MEDLINE | ID: mdl-23718640

ABSTRACT

Abstract : The persistence of Giardia, Cryptosporidium, Rotavirus, and Adenovirus in samples of raw and treated sewage collected monthly in 2010 at the Biological Wastewater Treatment Plant of Ribeirão Preto, SP, Brazil, was analyzed. The USEPA Method 1623 was used to detect and quantify Giardia and Cryptosporidium. An enzyme immunoassay was carried out to test Rotavirus and Adenovirus antigen optical density (Rotascreen® and Adenoscreen®). The results show a significant decrease in the concentrations of Giardia, Rotavirus and Adenovirus (P < 0.05) and a trend of decreasing Cryptosporidium densities, without statistical significance. Giardia concentrations ranged from 120 to 2,200 cysts/L in raw sewage and from 0.45 to 3.5 cysts/L in treated sewage. Cryptosporidium concentration ranged from undetectable to 28.9 oocysts/L in raw sewage and undetectable to 1.05 oocysts/L in treated sewage. Rotavirus presented absorbance values that ranged from 1.17 ± 0.81 in raw sewage to 0.46 ± 0.32 in treated sewage. Adenovirus, in turn, presented absorbance values of 0.64 ± 0.20 in raw sewage and of 0.45 ± 0.04 in treated sewage. There was no significant seasonal tendency observed in the distribution of protozoa (oo)cysts and in the viral antigen density in the monthly sewage samples during 2010 (P > 0.05). Even though these pathogenic agents decreased after treatment, the remaining loads observed in treated sewage can reach the watercourses receiving it. Giardia, Cryptosporidium, Rotavirus, and Adenovirus are pathogens with very low infectious doses, representing a public health risk especially for vulnerable groups, such as children living near these watercourses and homeless people using this water for various purposes. Studies addressing the environmental persistence of opportunistic pathogens in watercourses are hugely important in the public health sphere, especially in developing countries, where economic, social, cultural, and environmental factors still persist that are favorable to population's exposure to diarrhea-causing agents.


Subject(s)
Adenoviridae/isolation & purification , Cryptosporidium/isolation & purification , Giardia/isolation & purification , Rotavirus/isolation & purification , Sewage/parasitology , Sewage/virology , Adenoviridae/growth & development , Adenoviridae/immunology , Antigens, Viral/analysis , Brazil , Cryptosporidium/growth & development , Giardia/growth & development , Oocysts , Rotavirus/growth & development , Rotavirus/immunology , Waste Disposal, Fluid/methods , Waste Disposal, Fluid/standards
SELECTION OF CITATIONS
SEARCH DETAIL
...