Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Language
Publication year range
1.
Am J Dent ; 33(4): 187-190, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32794392

ABSTRACT

PURPOSE: To evaluate in vitro the effect of a continuous mechanical polishing protocol, performed in different periods, on the surface roughness of acrylic resin teeth subjected to toothbrushing (Br). METHODS: Artificial acrylic teeth (n=30) were randomly divided into three groups according to the polishing protocol and toothbrushing (Br): Br; Br+Pol15 (Br associated with a biweekly polishing); Br+Pol30 (monthly polishing). Br group was subjected to a total of 89,000 brushing cycles. Polishing was performed by applying aluminum oxide paste to the specimens with a felt wheel coupled to an electric motor (5 seconds, 3,000 rpm) after each 741 and 1482 brushing cycles for Br+Pol15 and Br+Pol30 groups, respectively. A contact profilometer and an analytical balance were used to measure surface roughness and mass changes before (T0) and after 1, 2, 3, and 5 years (T4) of simulated toothbrushing. Scanning electron microscopy (SEM) images were obtained. Differences among groups were tested by means of two-way ANOVA/Bonferroni tests (P= 0.05). RESULTS: Toothbrushing gradually increased surface roughness [T0 - 0.16 (0.01); T4 - 0.30 (0.10); P< 0.001]. The tested polishing promoted a significant roughness reduction (P< 0.001) for both biweekly [T4 - 0.09 (0.01) ] and monthly [T4 - 0.13 (0.02) ] regimes, and it did not influence the mass alterations caused by toothbrushing. SEM showed a smoother aspect of the material surface subjected to biweekly polishing with less defects caused by brushing abrasiveness. CLINICAL SIGNIFICANCE: In order to reduce the effects of various deleterious factors on the properties of acrylic resin for removable prostheses during their period of use, a frequent mechanical polishing protocol could increase clinical performance and extend the lifespan of these appliances. Furthermore, a polishing protocol by means of a simple technique could be employed by patients in a home environment.


Subject(s)
Dental Polishing , Toothbrushing , Acrylic Resins , Composite Resins , Humans , Materials Testing , Microscopy, Electron, Scanning , Surface Properties , Tooth, Artificial
2.
J Dent ; 99: 103357, 2020 08.
Article in English | MEDLINE | ID: mdl-32437857

ABSTRACT

OBJECTIVES: To compare one- vs two-step impression procedures for the provision of conventional complete dentures (CCDs) for edentulous individuals with severe mandibular resorption, in terms of (1) masticatory performance and ability; (2) satisfaction with mandibular CCDs; and (3) post-delivery adjustments. METHODS: Fifty-two patients requiring maxillary + mandibular CCDs were randomly divided into two parallel arms according to the impression method of the mandibular ridge: (SI) single impression with stock trays (irreversible hydrocolloid); (TI) two-step impression in custom trays, with border molding (impression compound) followed by the impression itself (polyether). Mastication performance was evaluated by a colorimetric test, whereas patients answered questions on masticatory ability and satisfaction with mandibular CCDs (100-mm visual analogue scale). The number of post-delivery sessions for adjustments were also quantified. Outcomes were assessed at 3 and 6 months after delivery. RESULTS: The masticatory performance was similar for both groups, regardless of time (3 months, P = 0.62; 6 months, P = 0.61). No significant difference was found for patient-reported (P > 0.05), i.e. masticatory ability (general ease of chewing and quality of grinding food; ability to chew specific foods), general satisfaction with the mandibular CCD (general satisfaction, comfort, aesthetics, ability to speak and to perform correct cleaning, retention and stability). Both methods resulted in a similar number of post-delivery adjustment sessions [SI: 3.8 (1.7); TI: 3.2 (1.4); P = 0.09]. CONCLUSIONS: Compared to a traditional approach, CCDs obtained from a single impression achieve similar masticatory performance/ability and patient satisfaction, even in patients with severely reabsorbed mandibular ridge. Both methods demand the same amount of post-delivery adjustment. CLINICAL SIGNIFICANCE: A simplified impression technique which eliminates the secondary impression can provide CCDs of good clinical quality, which influences the OHRQoL, and satisfaction in the same extent they would by a two-step procedure, even for patients with severely reabsorbed mandibular ridges (ClinicalTrials.gov: NCT02339194).


Subject(s)
Mastication , Mouth, Edentulous , Denture Retention , Denture, Complete , Humans , Mandible , Patient Satisfaction
3.
J Dent ; 98: 103356, 2020 07.
Article in English | MEDLINE | ID: mdl-32380132

ABSTRACT

OBJECTIVES: To evaluate the effectiveness of CCDs produced by two impression procedures for the mandibular ridge, in patients with severe mandibular atrophy. METHODS: Fifty-two completely edentulous patients with severely resorbed mandibles were randomly allocated into two groups according to the impression procedure of the mandibular ridge: SI - single impression (stock tray and irreversible hydrocolloid); TI - two-step impression (custom tray, border molding with compound, and polyether). Assessments of oral health related quality of life (OHRQoL, primary outcome) and denture satisfaction were performed by using validated questionnaires. Denture quality was evaluated by means of functional tests. RESULTS: Regardless of the technique, participants reported better OHRQoL (P < 0.001) in both follow-up periods (3 and 6 months after denture delivery), and groups resulted in similar OHIP-EDENT scores in its different domains (P > 0.05). Between-group differences were insignificant for general satisfaction (3 months, P = 0.699, 6 months, P = 0.392), as well as for aspects such as esthetics, comfort, mastication, speech, and prosthesis retention (P > 0.05). Overall clinical quality of the CCDs (P = 0.383) was similar between-group, as well as in specific aspects - interocclusal distance, occlusion, articulation, retention of the maxillary denture, and stability of both maxillary and mandibular dentures (P > 0.05). CONCLUSIONS: Mandibular CCDs based on a single impression technique showed quality levels comparable to those generated by a two-step impression, both from the patient and clinician perspective. CLINICAL SIGNIFICANCE: A simplified impression technique which eliminates the secondary impression can provide CCDs of good clinical quality, which influences the OHRQoL, and satisfaction in the same extent they would by a two-step procedure, even for patients with severely reabsorbed mandibular ridges. (ClinicalTrials.gov: NCT02339194).


Subject(s)
Denture Retention , Quality of Life , Denture, Complete , Humans , Mandible , Patient Satisfaction , Perception
4.
J Prosthet Dent ; 114(2): 293-6, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25976710

ABSTRACT

Malignant tumors in the nasal region may be treated by means of invasive surgical procedures, with large facial losses. Nasal prostheses, retained by osseointegrated facial implants, instead of plastic surgery, will, in most patients, offer good biomechanical and cosmetic results. This clinical report describes the prosthetic rehabilitation of a patient with nasal cancer who had the entire nasal vestibule removed in a single-stage surgical procedure in order to shorten the rehabilitation time. The nasal prosthesis was built on a 3-magnet bar and was made of platinum silicone with intrinsic pigmentation, thereby restoring the patient's appearance and self-esteem. The authors concluded that single-stage implants may reduce the rehabilitation time to as little as 1 month, and the correct use of materials and techniques may significantly improve the nasal prosthesis.


Subject(s)
Nose , Osseointegration/physiology , Prostheses and Implants , Aged , Carcinoma, Basal Cell/rehabilitation , Carcinoma, Basal Cell/surgery , Chromium Alloys/chemistry , Esthetics , Humans , Magnets , Male , Nose Neoplasms/rehabilitation , Nose Neoplasms/surgery , Platinum/chemistry , Prosthesis Coloring , Prosthesis Design , Prosthesis Retention , Self Concept , Silicones/chemistry
5.
J Prosthodont ; 18(5): 427-31, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19486455

ABSTRACT

PURPOSE: The aim of this study was to evaluate the effect of three denture hygiene methods against different microbial biofilms formed on acrylic resin specimens. MATERIALS AND METHODS: The set (sterile stainless steel basket and specimens) was contaminated (37 degrees C for 48 hours) by a microbial inoculum with 10(6) colony-forming units (CFU)/ml (standard strains: Staphylococcus aureus, Streptococcus mutans, Escherichia coli, Candida albicans, Pseudomonas aeruginosa, and Enterococcus faecalis; field strains: S. mutans, C. albicans, C. glabrata, and C. tropicalis). After inoculation, specimens were cleansed by the following methods: (1) chemical: immersion in an alkaline peroxide solution (Bonyplus tablets) for 5 minutes; (2) mechanical: brushing with a dentifrice for removable prostheses (Dentu Creme) for 20 seconds; and (3) a combination of chemical and mechanical methods. Specimens were applied onto a Petri plate with appropriate culture medium for 10 minutes. Afterward, the specimens were removed and the plates incubated at 37 degrees C for 48 hours. RESULTS: Chemical, mechanical, and combination methods showed no significant difference in the reduction of CFU for S. aureus, S. mutans (ATCC and field strain), and P. aeruginosa. Mechanical and combination methods were similar and more effective than the chemical method for E. faecalis, C. albicans (ATCC and field strain), and C. glabrata. The combination method was better than the chemical method for E. coli and C. tropicalis, and the mechanical method showed intermediate results. CONCLUSION: The three denture hygiene methods showed different effects depending on the type of microbial biofilms formed on acrylic base resin specimens.


Subject(s)
Biofilms/drug effects , Denture Cleansers , Denture, Complete/microbiology , Oral Hygiene/methods , Toothbrushing/methods , Acrylic Resins , Colony Count, Microbial , Denture Bases/microbiology , Disinfection/methods , Statistics, Nonparametric
6.
J. appl. oral sci ; 17(2): 116-121, Mar.-Apr. 2009. graf, tab
Article in English | LILACS | ID: lil-503989

ABSTRACT

The association between a toothbrush and a dentifrice is the most used denture cleaning method. The purpose of this study was to evaluate the abrasiveness of specific and non-specific denture cleaning dentifrices on different heat-polymerized acrylic resins. Sixteen specimens (90x30x3mm) of each acrylic resin (QC-20, Lucitone 550, Clássico, Vipi-Cril) were prepared and randomly assigned to 4 groups: 1: control (distilled water), 2: Colgate, 3: Bonyplus and 4: Dentu-Creme. The specimens were subjected to simulated toothbrushing in an automatic brushing machine using 35,600 brush strokes for each specimen. Brushing abrasion run at a 200-g load with the specimens immersed in 2:1 dentifrice/water slurry. Specimens were reconditioned to constant mass and the mass loss (mg) was evaluated. Data were analyzed by 2-way ANOVA and Tukey's test (a=0.05). Analysis of dentifrices' abrasive particles was made by scanning electron microscopy. Colgate produced the greatest mass reduction (42.44 mg, p<0.05), followed by Dentu-Creme (33.60 mg). Bonyplus was the less abrasive (19.91 mg), similar to the control group (19.69 mg) (p>0.05). The mass loss values indicated that QC-20 (33.13 mg) and Lucitone 550 (33.05 mg) resins were less (p<0.05) resistant to abrasion than Clássico (26.04 mg) and Vipi-Cril (23.43 mg). In conclusion, Colgate produced the greatest abrasion. Specific dentifrices for dentures tend to cause less damage to acrylic resins.


Subject(s)
Acrylic Resins/chemistry , Dental Restoration Wear , Denture Cleansers/chemistry , Dental Stress Analysis , Materials Testing , Random Allocation , Toothbrushing
7.
J Appl Oral Sci ; 17(2): 116-21, 2009.
Article in English | MEDLINE | ID: mdl-19274397

ABSTRACT

The association between a toothbrush and a dentifrice is the most used denture cleaning method. The purpose of this study was to evaluate the abrasiveness of specific and non-specific denture cleaning dentifrices on different heat-polymerized acrylic resins. Sixteen specimens (90 x 30 x 3 mm) of each acrylic resin (QC-20, Lucitone 550, Clássico, Vipi-Cril) were prepared and randomly assigned to 4 groups: 1: control (distilled water), 2: Colgate, 3: Bonyplus and 4: Dentu-Creme. The specimens were subjected to simulated toothbrushing in an automatic brushing machine using 35,600 brush strokes for each specimen. Brushing abrasion run at a 200-g load with the specimens immersed in 2:1 dentifrice/water slurry. Specimens were reconditioned to constant mass and the mass loss (mg) was evaluated. Data were analyzed by 2-way ANOVA and Tukey's test (a=0.05). Analysis of dentifrices' abrasive particles was made by scanning electron microscopy. Colgate produced the greatest mass reduction (42.44 mg, p<0.05), followed by Dentu-Creme (33.60 mg). Bonyplus was the less abrasive (19.91 mg), similar to the control group (19.69 mg) (p>0.05). The mass loss values indicated that QC-20 (33.13 mg) and Lucitone 550 (33.05 mg) resins were less (p<0.05) resistant to abrasion than Clássico (26.04 mg) and Vipi-Cril (23.43 mg). In conclusion, Colgate produced the greatest abrasion. Specific dentifrices for dentures tend to cause less damage to acrylic resins.


Subject(s)
Acrylic Resins/chemistry , Dental Restoration Wear , Denture Cleansers/chemistry , Dental Stress Analysis , Materials Testing , Random Allocation , Toothbrushing
SELECTION OF CITATIONS
SEARCH DETAIL
...