Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
Add more filters










Publication year range
1.
Phys Rev Lett ; 126(10): 104802, 2021 Mar 12.
Article in English | MEDLINE | ID: mdl-33784160

ABSTRACT

We report the demonstration of optical compression of an electron beam and the production of controllable trains of femtosecond, soft x-ray pulses with the Linac Coherent Light Source (LCLS) free-electron laser (FEL). This is achieved by enhanced self-amplified spontaneous emission with a 2 µm laser and a dechirper device. Optical compression was achieved by modulating the energy of an electron beam with the laser and then compressing with a chicane, resulting in high current spikes on the beam which we observe to lase. A dechirper was then used to selectively control the lasing region of the electron beam. Field autocorrelation measurements indicate a train of pulses, and we find that the number of pulses within the train can be controlled (from 1 to 5 pulses) by varying the dechirper position and undulator taper. These results are a step toward attosecond spectroscopy with x-ray FELs as well as future FEL schemes relying on optical compression of an electron beam.

2.
Sci Rep ; 11(1): 796, 2021 Jan 12.
Article in English | MEDLINE | ID: mdl-33436972

ABSTRACT

The structural versatility of light underpins an outstanding collection of optical phenomena where both geometrical and topological states of light can dictate how matter will respond or display. Light possesses multiple degrees of freedom such as amplitude, and linear, spin angular, and orbital angular momenta, but the ability to adaptively engineer the spatio-temporal distribution of all these characteristics is primarily curtailed by technologies used to impose any desired structure to light. We demonstrate a laser architecture based on coherent beam combination offering integrated spatio-temporal field control and programmability, thereby presenting unique opportunities for generating light by design to exploit its topology.

3.
Opt Express ; 28(16): 23545-23553, 2020 Aug 03.
Article in English | MEDLINE | ID: mdl-32752349

ABSTRACT

We design and realize an arrival time diagnostic for ultrashort X-ray pulses achieving unprecedented high sensitivity in the soft X-ray regime via cross-correlation with a ≈1550 nm optical laser. An interferometric detection scheme is combined with a multi-layer sample design to greatly improve the sensitivity of the measurement. We achieve up to 275% of relative signal change when exposed to 1.6 mJ/cm2 of soft X-rays at 530 eV, more than a hundred-fold improvement in sensitivity as compared to previously reported techniques. The resolution of the arrival time measurement is estimated to around 2.8 fs (rms). The demonstrated X-ray arrival time monitor paves the way for sub-10 fs-level timing jitter at high repetition rate X-ray facilities.

4.
J Chem Phys ; 152(8): 084307, 2020 Feb 28.
Article in English | MEDLINE | ID: mdl-32113333

ABSTRACT

We report experimental results on the diffractive imaging of three-dimensionally aligned 2,5-diiodothiophene molecules. The molecules were aligned by chirped near-infrared laser pulses, and their structure was probed at a photon energy of 9.5 keV (λ ≈ 130 pm) provided by the Linac Coherent Light Source. Diffracted photons were recorded on the Cornell-SLAC pixel array detector, and a two-dimensional diffraction pattern of the equilibrium structure of 2,5-diiodothiophene was recorded. The retrieved distance between the two iodine atoms agrees with the quantum-chemically calculated molecular structure to be within 5%. The experimental approach allows for the imaging of intrinsic molecular dynamics in the molecular frame, albeit this requires more experimental data, which should be readily available at upcoming high-repetition-rate facilities.

5.
Opt Lett ; 44(17): 4287-4290, 2019 Sep 01.
Article in English | MEDLINE | ID: mdl-31465384

ABSTRACT

New high-repetition-rate x-ray free electron lasers (XFELs) require for their operation highly reliable ultrafast laser systems with high pulse energy, high repetition rate, and high average power. In this Letter, we present high-average-power scaling of near-infrared optical parametric chirped pulse amplification (OPCPA) in potassium titanyl arsenate (KTA) with tunable center wavelengths from 1.5 to 2.0 µm. Using a three-stage amplification scheme and a kW-level InnoSlab Yb:YAG pump amplifier for the final non-collinear KTA stage, we demonstrate an amplified output power of 106.2 W at a center wavelength of 1.75 µm and 100 kHz. Idler absorption introduces a potential upper limit on the average power scaling of center wavelengths <1.70 µm. Future scaling of average power to hundreds of Watts is possible at center wavelengths ≥1.70 µm.

6.
Opt Lett ; 44(5): 1257-1260, 2019 Mar 01.
Article in English | MEDLINE | ID: mdl-30821762

ABSTRACT

We present a 100 kHz, sub-20 fs optical parametric chirped-pulse amplifier (OPCPA) system delivering 88.6 W average power at a center wavelength of 800 nm. The seed pulses are derived from the pump laser via white-light continuum generation and are amplified in three non-collinear OPCPA stages. The final two high-power stages are pumped with a 661 W Yb:YAG InnoSlab amplifier. A simple and robust design is used for the OPCPA system to avoid thermal effects and enhance long-term stability, resulting in excellent beam quality and high conversion efficiency. To the best of our knowledge, this is the highest average power OPCPA system reported to date.

7.
Rev Sci Instrum ; 88(10): 105113, 2017 Oct.
Article in English | MEDLINE | ID: mdl-29092479

ABSTRACT

We measure the shock drive capabilities of a 30 J, nanosecond, 527 nm laser system at the matter in extreme conditions hutch of the Linac Coherent Light Source. Using a velocity interferometer system for any reflector, we ascertain the maximum instantaneous ablation pressure and characterize its dependence on a drive laser spot size, spatial profile, and temporal profile. We also examine the effects of these parameters on shock spatial and temporal uniformity. Our analysis shows the drive laser capable of generating instantaneous ablation pressures exceeding 160 GPa while maintaining a 1D shock profile. We find that slope pulses provide higher instantaneous ablation pressures than plateau pulses. Our results show instantaneous ablation pressures comparable to those measured at the Omega Laser Facility in Rochester, NY under similar optical drive parameters. Finally, we analyze how optical laser ablation pressures are compare with known scaling relations, accounting for variable laser wavelengths.

8.
Sci Adv ; 3(7): e1602388, 2017 07.
Article in English | MEDLINE | ID: mdl-28782016

ABSTRACT

Femtosecond resolution electron scattering techniques are applied to resolve the first atomic-scale steps following absorption of a photon in the prototypical hybrid perovskite methylammonium lead iodide. Following above-gap photoexcitation, we directly resolve the transfer of energy from hot carriers to the lattice by recording changes in the mean square atomic displacements on 10-ps time scales. Measurements of the time-dependent pair distribution function show an unexpected broadening of the iodine-iodine correlation function while preserving the Pb-I distance. This indicates the formation of a rotationally disordered halide octahedral structure developing on picosecond time scales. This work shows the important role of light-induced structural deformations within the inorganic sublattice in elucidating the unique optoelectronic functionality exhibited by hybrid perovskites and provides new understanding of hot carrier-lattice interactions, which fundamentally determine solar cell efficiencies.

9.
Rev Sci Instrum ; 87(10): 103701, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27802688

ABSTRACT

We describe the phase-contrast imaging instrument at the Matter in Extreme Conditions (MEC) endstation of the Linac Coherent Light Source. The instrument can image phenomena with a spatial resolution of a few hundreds of nanometers and at the same time reveal the atomic structure through X-ray diffraction, with a temporal resolution better than 100 fs. It was specifically designed for studies relevant to high-energy-density science and can monitor, e.g., shock fronts, phase transitions, or void collapses. This versatile instrument was commissioned last year and is now available to the MEC user community.

10.
Faraday Discuss ; 194: 563-581, 2016 12 16.
Article in English | MEDLINE | ID: mdl-27711826

ABSTRACT

We present results on ultrafast gas electron diffraction (UGED) experiments with femtosecond resolution using the MeV electron gun at SLAC National Accelerator Laboratory. UGED is a promising method to investigate molecular dynamics in the gas phase because electron pulses can probe the structure with a high spatial resolution. Until recently, however, it was not possible for UGED to reach the relevant timescale for the motion of the nuclei during a molecular reaction. Using MeV electron pulses has allowed us to overcome the main challenges in reaching femtosecond resolution, namely delivering short electron pulses on a gas target, overcoming the effect of velocity mismatch between pump laser pulses and the probe electron pulses, and maintaining a low timing jitter. At electron kinetic energies above 3 MeV, the velocity mismatch between laser and electron pulses becomes negligible. The relativistic electrons are also less susceptible to temporal broadening due to the Coulomb force. One of the challenges of diffraction with relativistic electrons is that the small de Broglie wavelength results in very small diffraction angles. In this paper we describe the new setup and its characterization, including capturing static diffraction patterns of molecules in the gas phase, finding time-zero with sub-picosecond accuracy and first time-resolved diffraction experiments. The new device can achieve a temporal resolution of 100 fs root-mean-square, and sub-angstrom spatial resolution. The collimation of the beam is sufficient to measure the diffraction pattern, and the transverse coherence is on the order of 2 nm. Currently, the temporal resolution is limited both by the pulse duration of the electron pulse on target and by the timing jitter, while the spatial resolution is limited by the average electron beam current and the signal-to-noise ratio of the detection system. We also discuss plans for improving both the temporal resolution and the spatial resolution.

11.
Phys Rev Lett ; 117(15): 153002, 2016 Oct 07.
Article in English | MEDLINE | ID: mdl-27768362

ABSTRACT

Observing the motion of the nuclear wave packets during a molecular reaction, in both space and time, is crucial for understanding and controlling the outcome of photoinduced chemical reactions. We have imaged the motion of a vibrational wave packet in isolated iodine molecules using ultrafast electron diffraction with relativistic electrons. The time-varying interatomic distance was measured with a precision 0.07 Å and temporal resolution of 230 fs full width at half maximum. The method is not only sensitive to the position but also the shape of the nuclear wave packet.

12.
Nat Commun ; 7: 11232, 2016 Apr 05.
Article in English | MEDLINE | ID: mdl-27046298

ABSTRACT

Imaging changes in molecular geometries on their natural femtosecond timescale with sub-Angström spatial precision is one of the critical challenges in the chemical sciences, as the nuclear geometry changes determine the molecular reactivity. For photoexcited molecules, the nuclear dynamics determine the photoenergy conversion path and efficiency. Here we report a gas-phase electron diffraction experiment using megaelectronvolt (MeV) electrons, where we captured the rotational wavepacket dynamics of nonadiabatically laser-aligned nitrogen molecules. We achieved a combination of 100 fs root-mean-squared temporal resolution and sub-Angstrom (0.76 Å) spatial resolution that makes it possible to resolve the position of the nuclei within the molecule. In addition, the diffraction patterns reveal the angular distribution of the molecules, which changes from prolate (aligned) to oblate (anti-aligned) in 300 fs. Our results demonstrate a significant and promising step towards making atomically resolved movies of molecular reactions.

13.
Nano Lett ; 15(10): 6889-95, 2015 Oct 14.
Article in English | MEDLINE | ID: mdl-26322659

ABSTRACT

Two-dimensional materials are subject to intrinsic and dynamic rippling that modulates their optoelectronic and electromechanical properties. Here, we directly visualize the dynamics of these processes within monolayer transition metal dichalcogenide MoS2 using femtosecond electron scattering techniques as a real-time probe with atomic-scale resolution. We show that optical excitation induces large-amplitude in-plane displacements and ultrafast wrinkling of the monolayer on nanometer length-scales, developing on picosecond time-scales. These deformations are associated with several percent peak strains that are fully reversible over tens of millions of cycles. Direct measurements of electron-phonon coupling times and the subsequent interfacial thermal heat flow between the monolayer and substrate are also obtained. These measurements, coupled with first-principles modeling, provide a new understanding of the dynamic structural processes that underlie the functionality of two-dimensional materials and open up new opportunities for ultrafast strain engineering using all-optical methods.

14.
J Synchrotron Radiat ; 22(3): 526-31, 2015 May.
Article in English | MEDLINE | ID: mdl-25931064

ABSTRACT

Ultrafast optical lasers play an essential role in exploiting the unique capabilities of recently commissioned X-ray free-electron laser facilities such as the Linac Coherent Light Source (LCLS). Pump-probe experimental techniques reveal ultrafast dynamics in atomic and molecular processes and reveal new insights in chemistry, biology, material science and high-energy-density physics. This manuscript describes the laser systems and experimental methods that enable cutting-edge optical laser/X-ray pump-probe experiments to be performed at LCLS.


Subject(s)
Crystallography, X-Ray/instrumentation , Lasers , Particle Accelerators/instrumentation , Spectrometry, X-Ray Emission/instrumentation , X-Rays , California , Energy Transfer , Equipment Design , Equipment Failure Analysis , Lighting/instrumentation
15.
Nat Commun ; 5: 4371, 2014 Jul 09.
Article in English | MEDLINE | ID: mdl-25006873

ABSTRACT

The dioxygen we breathe is formed by light-induced oxidation of water in photosystem II. O2 formation takes place at a catalytic manganese cluster within milliseconds after the photosystem II reaction centre is excited by three single-turnover flashes. Here we present combined X-ray emission spectra and diffraction data of 2-flash (2F) and 3-flash (3F) photosystem II samples, and of a transient 3F' state (250 µs after the third flash), collected under functional conditions using an X-ray free electron laser. The spectra show that the initial O-O bond formation, coupled to Mn reduction, does not yet occur within 250 µs after the third flash. Diffraction data of all states studied exhibit an anomalous scattering signal from Mn but show no significant structural changes at the present resolution of 4.5 Å. This study represents the initial frames in a molecular movie of the structural changes during the catalytic reaction in photosystem II.


Subject(s)
Photosynthesis/physiology , Spectrometry, X-Ray Emission/methods , Water/metabolism , X-Ray Diffraction/methods , Cyanobacteria/metabolism , Models, Chemical , Oxidation-Reduction , Oxygen/metabolism , Photosystem II Protein Complex/chemistry , Photosystem II Protein Complex/metabolism
16.
Nat Methods ; 11(5): 545-8, 2014 May.
Article in English | MEDLINE | ID: mdl-24633409

ABSTRACT

X-ray free-electron laser (XFEL) sources enable the use of crystallography to solve three-dimensional macromolecular structures under native conditions and without radiation damage. Results to date, however, have been limited by the challenge of deriving accurate Bragg intensities from a heterogeneous population of microcrystals, while at the same time modeling the X-ray spectrum and detector geometry. Here we present a computational approach designed to extract meaningful high-resolution signals from fewer diffraction measurements.


Subject(s)
Lasers , Macromolecular Substances/chemistry , Bacillus/enzymology , Calcium/chemistry , Calibration , Computer Simulation , Crystallization , Crystallography, X-Ray , Electrons , Equipment Design , Likelihood Functions , Models, Chemical , Molecular Conformation , Muramidase/chemistry , Nanotechnology , Reproducibility of Results , Software , Thermolysin/chemistry , X-Rays , Zinc/chemistry
17.
Science ; 340(6131): 491-5, 2013 Apr 26.
Article in English | MEDLINE | ID: mdl-23413188

ABSTRACT

Intense femtosecond x-ray pulses produced at the Linac Coherent Light Source (LCLS) were used for simultaneous x-ray diffraction (XRD) and x-ray emission spectroscopy (XES) of microcrystals of photosystem II (PS II) at room temperature. This method probes the overall protein structure and the electronic structure of the Mn4CaO5 cluster in the oxygen-evolving complex of PS II. XRD data are presented from both the dark state (S1) and the first illuminated state (S2) of PS II. Our simultaneous XRD-XES study shows that the PS II crystals are intact during our measurements at the LCLS, not only with respect to the structure of PS II, but also with regard to the electronic structure of the highly radiation-sensitive Mn4CaO5 cluster, opening new directions for future dynamics studies.


Subject(s)
Manganese Compounds/chemistry , Oxides/chemistry , Photosystem II Protein Complex/chemistry , Crystallography, X-Ray/methods , Cyanobacteria/enzymology , Electrons , Light , Oxidation-Reduction , Photosystem II Protein Complex/radiation effects , Protein Conformation , Spectrometry, X-Ray Emission/methods , Temperature , Water/chemistry , X-Ray Diffraction/methods
18.
Proc Natl Acad Sci U S A ; 109(47): 19103-7, 2012 Nov 20.
Article in English | MEDLINE | ID: mdl-23129631

ABSTRACT

The ultrabright femtosecond X-ray pulses provided by X-ray free-electron lasers open capabilities for studying the structure and dynamics of a wide variety of systems beyond what is possible with synchrotron sources. Recently, this "probe-before-destroy" approach has been demonstrated for atomic structure determination by serial X-ray diffraction of microcrystals. There has been the question whether a similar approach can be extended to probe the local electronic structure by X-ray spectroscopy. To address this, we have carried out femtosecond X-ray emission spectroscopy (XES) at the Linac Coherent Light Source using redox-active Mn complexes. XES probes the charge and spin states as well as the ligand environment, critical for understanding the functional role of redox-active metal sites. Kß(1,3) XES spectra of Mn(II) and Mn(2)(III,IV) complexes at room temperature were collected using a wavelength dispersive spectrometer and femtosecond X-ray pulses with an individual dose of up to >100 MGy. The spectra were found in agreement with undamaged spectra collected at low dose using synchrotron radiation. Our results demonstrate that the intact electronic structure of redox active transition metal compounds in different oxidation states can be characterized with this shot-by-shot method. This opens the door for studying the chemical dynamics of metal catalytic sites by following reactions under functional conditions. The technique can be combined with X-ray diffraction to simultaneously obtain the geometric structure of the overall protein and the local chemistry of active metal sites and is expected to prove valuable for understanding the mechanism of important metalloproteins, such as photosystem II.

19.
Acta Crystallogr D Biol Crystallogr ; 68(Pt 11): 1584-7, 2012 Nov.
Article in English | MEDLINE | ID: mdl-23090408

ABSTRACT

An electrospun liquid microjet has been developed that delivers protein microcrystal suspensions at flow rates of 0.14-3.1 µl min(-1) to perform serial femtosecond crystallography (SFX) studies with X-ray lasers. Thermolysin microcrystals flowed at 0.17 µl min(-1) and diffracted to beyond 4 Å resolution, producing 14,000 indexable diffraction patterns, or four per second, from 140 µg of protein. Nanoflow electrospinning extends SFX to biological samples that necessitate minimal sample consumption.


Subject(s)
Crystallography, X-Ray/instrumentation , Crystallization , Crystallography, X-Ray/economics , Electromagnetic Fields , Equipment Design , Kinetics , Lasers , Sample Size , Thermolysin/chemistry
20.
Proc Natl Acad Sci U S A ; 109(25): 9721-6, 2012 Jun 19.
Article in English | MEDLINE | ID: mdl-22665786

ABSTRACT

Most of the dioxygen on earth is generated by the oxidation of water by photosystem II (PS II) using light from the sun. This light-driven, four-photon reaction is catalyzed by the Mn(4)CaO(5) cluster located at the lumenal side of PS II. Various X-ray studies have been carried out at cryogenic temperatures to understand the intermediate steps involved in the water oxidation mechanism. However, the necessity for collecting data at room temperature, especially for studying the transient steps during the O-O bond formation, requires the development of new methodologies. In this paper we report room temperature X-ray diffraction data of PS II microcrystals obtained using ultrashort (< 50 fs) 9 keV X-ray pulses from a hard X-ray free electron laser, namely the Linac Coherent Light Source. The results presented here demonstrate that the "probe before destroy" approach using an X-ray free electron laser works even for the highly-sensitive Mn(4)CaO(5) cluster in PS II at room temperature. We show that these data are comparable to those obtained in synchrotron radiation studies as seen by the similarities in the overall structure of the helices, the protein subunits and the location of the various cofactors. This work is, therefore, an important step toward future studies for resolving the structure of the Mn(4)CaO(5) cluster without any damage at room temperature, and of the reaction intermediates of PS II during O-O bond formation.


Subject(s)
Crystallography, X-Ray/methods , Photosystem II Protein Complex/chemistry , Catalysis , Crystallization , Models, Molecular
SELECTION OF CITATIONS
SEARCH DETAIL
...