Ann Med ; 55(2): 2247422, 2023.
Article in English | MEDLINE | ID: mdl-37619404

ABSTRACT

OBJECTIVE: This study aimed to evaluate the effects on the dislocation and misalignment of the cuffed end of a double-lumen endobronchial tube (DLT) when a patient moves from a horizontal to a lateral position without fixation. METHODS: A total of 148 patients who had undergone video-assisted thoracoscope surgery were enrolled and randomly divided into two groups: a group in which the periportal end of the DLT was fixed with tape (group I; n = 74) and a group in which the periportal end of the DLT remained unfixed (group II; n = 74). Both groups were given an intravenous induction for double-lumen endobronchial intubation and then moved from a horizontal position to a lateral position, after which the alignment of the bronchial cuffed end of the DLT was assessed using a fiberoptic bronchoscope. RESULTS: After lateral position, the dislocation rate of group I and group II was 44.6% and 20.2%, and the misalignment rate was 27.0% and 8.1%, respectively, the incidence of dislocation and misalignment was significantly lower in group II than in group I after the change to a lateral position (p < 0.05). After lateral position, the total rate of airway injury was 25.7% in group I and 5.4% in group II, the incidence of airway injury was significantly lower in group II than in group I (p < 0.05), as was the incidence of sore throat, hoarseness, and cough on postoperative day 1 (p < 0.05). The average outward dislocation of the periportal end of the DLT in group II was 1.5 cm. CONCLUSION: A DLT without periportal fixation is less likely to be displaced and poorly aligned when the patient moves from a horizontal to a lateral position, which could facilitate intra-operative management and reduce the incidence of postoperative complications.


Through a randomized controlled trial, this study innovatively found that no double-lumen endobronchial tube (DLT) peripheral tape binding can prevent the dislocation and misalignment of the DLT bronchial cuffed end in patients undergoing thoracic surgery from horizontal to lateral position.


Subject(s)
Cough , Pain , Humans , Administration, Intravenous , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Postoperative Complications/prevention & control , Postoperative Period
SELECTION OF CITATIONS