Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
Add more filters










Publication year range
1.
Phys Rev Lett ; 127(22): 225001, 2021 Nov 24.
Article in English | MEDLINE | ID: mdl-34889640

ABSTRACT

We assess the magnetic field configuration in modern fusion devices by comparing experiments with the same heating power, between a stellarator and a heliotron. The key role of turbulence is evident in the optimized stellarator, while neoclassical processes largely determine the transport in the heliotron device. Gyrokinetic simulations elucidate the underlying mechanisms promoting stronger ion scale turbulence in the stellarator. Similar plasma performances in these experiments suggests that neoclassical and turbulent transport should both be optimized in next step reactor designs.

3.
Nature ; 596(7871): 221-226, 2021 08.
Article in English | MEDLINE | ID: mdl-34381232

ABSTRACT

Research on magnetic confinement of high-temperature plasmas has the ultimate goal of harnessing nuclear fusion for the production of electricity. Although the tokamak1 is the leading toroidal magnetic-confinement concept, it is not without shortcomings and the fusion community has therefore also pursued alternative concepts such as the stellarator. Unlike axisymmetric tokamaks, stellarators possess a three-dimensional (3D) magnetic field geometry. The availability of this additional dimension opens up an extensive configuration space for computational optimization of both the field geometry itself and the current-carrying coils that produce it. Such an optimization was undertaken in designing Wendelstein 7-X (W7-X)2, a large helical-axis advanced stellarator (HELIAS), which began operation in 2015 at Greifswald, Germany. A major drawback of 3D magnetic field geometry, however, is that it introduces a strong temperature dependence into the stellarator's non-turbulent 'neoclassical' energy transport. Indeed, such energy losses will become prohibitive in high-temperature reactor plasmas unless a strong reduction of the geometrical factor associated with this transport can be achieved; such a reduction was therefore a principal goal of the design of W7-X. In spite of the modest heating power currently available, W7-X has already been able to achieve high-temperature plasma conditions during its 2017 and 2018 experimental campaigns, producing record values of the fusion triple product for such stellarator plasmas3,4. The triple product of plasma density, ion temperature and energy confinement time is used in fusion research as a figure of merit, as it must attain a certain threshold value before net-energy-producing operation of a reactor becomes possible1,5. Here we demonstrate that such record values provide evidence for reduced neoclassical energy transport in W7-X, as the plasma profiles that produced these results could not have been obtained in stellarators lacking a comparably high level of neoclassical optimization.

4.
Rev Sci Instrum ; 92(4): 043505, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-34243367

ABSTRACT

In nuclear fusion research, the effective ion charge Zeff, which characterizes the overall content of impurities, can be experimentally derived from the plasma electron-ion bremsstrahlung, given the electron density ne and temperature Te. At Wendelstein 7-X, a multichannel near-infrared spectrometer is installed to collect the plasma bremsstrahlung along 27 lines of sight covering more than half the plasma cross section, which provides information on Zeff over the entire plasma radius. To infer spatially resolved Zeff profiles, a Bayesian model is developed in the Minerva framework. Zeff, ne, and Te profiles are modeled as Gaussian processes, whose smoothness is determined by hyperparameters. These profiles are transformed to fields in Cartesian coordinates, given the poloidal magnetic flux surfaces calculated by the variational moments equilibrium code. Given all these physical quantities, the model predicts line-of-sight integrals of near-infrared bremsstrahlung spectra. The model includes the predictive (forward) models of the interferometer, Thomson scattering system, and visible and near-infrared spectrometers. Given the observations of all these diagnostics, the posterior probability distribution of Zeff profiles is calculated and shown as an inference solution. The smoothness (gradient) of the profiles is optimally chosen by Bayesian Occam's razor. Furthermore, wall reflections can significantly pollute the measurements of the plasma bremsstrahlung, which leads to over-estimation of Zeff values in the edge region. In the first results presented in this work, this problem does not appear, and the posterior samples of Zeff profiles are overall plausible and consistent with Zeff values inferred, given the data from the single-channel visible spectrometer.

5.
Phys Rev Lett ; 125(7): 075001, 2020 Aug 14.
Article in English | MEDLINE | ID: mdl-32857529

ABSTRACT

We theoretically assess two mechanisms thought to be responsible for the enhanced performance observed in plasma discharges of the Wendelstein 7-X stellarator experiment fueled by pellet injection. The effects of the ambipolar radial electric field and the electron density peaking on the turbulent ion heat transport are separately evaluated using large-scale gyrokinetic simulations. The essential role of the stellarator magnetic geometry is demonstrated, by comparison with a tokamak.

6.
Rev Sci Instrum ; 91(2): 023507, 2020 Feb 01.
Article in English | MEDLINE | ID: mdl-32113444

ABSTRACT

The Charge Exchange Recombination Spectroscopy (CXRS) diagnostic has become a routine diagnostic on almost all major high temperature fusion experimental devices. For the optimized stellarator Wendelstein 7-X (W7-X), a highly flexible and extensive CXRS diagnostic has been built to provide high-resolution local measurements of several important plasma parameters using the recently commissioned neutral beam heating. This paper outlines the design specifics of the W7-X CXRS system and gives examples of the initial results obtained, including typical ion temperature profiles for several common heating scenarios, toroidal flow and radial electric field derived from velocity measurements, beam attenuation via beam emission spectra, and normalized impurity density profiles under some typical plasma conditions.

7.
Phys Rev Lett ; 123(2): 025002, 2019 Jul 12.
Article in English | MEDLINE | ID: mdl-31386539

ABSTRACT

For the first time, the optimized stellarator Wendelstein 7-X has operated with an island divertor. An operation regime in hydrogen was found in which the total plasma radiation approached the absorbed heating power without noticeable loss of stored energy. The divertor thermography recorded simultaneously a strong reduction of the heat load on all divertor targets, indicating almost complete power detachment. This operation regime was stably sustained over several energy confinement times until the preprogrammed end of the discharge. The plasma radiation is mainly due to oxygen and is located at the plasma edge. This plasma scenario is reproducible and robust at various heating powers, plasma densities, and gas fueling locations. These experimental results show that the island divertor concept actually works and displays good power dissipation potential, producing a promising exhaust concept for the stellarator reactor line.

8.
Rev Sci Instrum ; 90(6): 063505, 2019 Jun.
Article in English | MEDLINE | ID: mdl-31255024

ABSTRACT

At the Wendelstein 7-X stellarator, the X-ray imaging crystal spectrometer provides line integrated measurements of ion and electron temperatures, plasma flows, as well as impurity densities from a spectroscopic analysis of tracer impurity radiation. In order to infer the actual profiles from line integrated data, a forward modeling approach has been developed within the Minerva Bayesian analysis framework. In this framework, the inversion is realized on the basis of a complete forward model of the diagnostic, including error propagation and utilizing Gaussian processes for generation and inference of arbitrary shaped plasma parameter profiles. For modeling of line integrated data as measured by the detector, the installation geometry of the spectrometer, imaging properties of the crystal, and Gaussian detection noise are considered. The inversion of line integrated data is achieved using the maximum posterior method for plasma parameter profile inference and a Markov chain Monte Carlo sampling of the posterior distribution for calculating uncertainties of the inference process. The inversion method shows a correct and reliable inference of temperature and impurity density profiles from synthesized data within the estimated uncertainties along the whole plasma radius. The application to measured data yields a good match of derived electron temperature profiles to data of the Thomson scattering diagnostic for central electron temperatures between 2 and 5 keV using argon impurities.

9.
Rev Sci Instrum ; 90(3): 033505, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30927799

ABSTRACT

A new method for in situ spectral calibration of Thomson scattering diagnostics is proposed. The idea of the method is to apply a wavelength tunable optical parametric oscillator for measurements of Rayleigh scattering at different wavelengths, from which relative sensitivities can be calculated. This extends the usual approach where Rayleigh scattering is used only at a single wavelength for the absolute calibration and spectral sensitivities are obtained separately. With the new approach, the full diagnostic setup is spectrally calibrated at once. Such a calibration can be repeated at regular intervals during an experimental campaign since it does not require a break of the vacuum. In this paper, the Rayleigh scattering calibration is tested in a laboratory setup with a sample Wendelstein 7-X (W7-X) polychromator. It is shown that relative sensitivities of spectral channels can be recovered with a sufficient resolution even under conditions of significant stray light. The stray light is overcome by measuring the linear dependence of the scattered signal on the gas pressure. Good results of laboratory tests motivate the installation of the new calibration system for the Thomson scattering diagnostic at W7-X.

10.
Phys Rev Lett ; 122(3): 035002, 2019 Jan 25.
Article in English | MEDLINE | ID: mdl-30735428

ABSTRACT

Electron temperature gradient (ETG)-driven turbulence, despite its ultrafine scale, is thought to drive significant thermal losses in magnetic fusion devices-but what role does it play in stellarators? The first numerical simulations of ETG turbulence for the Wendelstein 7-X stellarator, together with power balance analysis from its initial experimental operation phase, suggest that the associated transport should be negligible compared to other channels. The effect, we argue, originates essentially from the geometric constraint of multiple field periods, a generic feature of stellarators.

11.
Rev Sci Instrum ; 89(10): 10C115, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399715

ABSTRACT

This paper presents the approach of the dual-laser wavelength Thomson scattering (TS) system for the Wendelstein 7-X stellarator. The dual-laser wavelength TS method is based on two lasers with different wavelengths being fired quasi-simultaneously. This method has two advantages compared to a single laser wavelength TS system. First, the dual laser availability allows an in situ spectral calibration, and second, higher electron temperatures can be measured without any change in the spectral filter setup of the polychromators. The W7-X dual-laser wavelength TS concept is based on high power lasers: a set of standard Nd:YAG lasers with λ = 1064 nm wavelength and a Nd:YAG laser with λ = 1319 nm wavelength newly developed for this application. This laser uses a different transition line with 34% efficiency compared to the main 1064 nm Nd:YAG line. Simulations of the expected performance of the new dual-laser wavelength system show that electron temperatures up to Te = 15 keV can be measured compared to the original design parameter up to Te = 10 keV. The in situ spectral calibration can be performed using a range of temperatures from 1 keV to 10 keV using TS measurements of the 1064 nm versus 1319 nm TS simultaneously.

12.
Rev Sci Instrum ; 89(10): 10G101, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399890

ABSTRACT

This paper reports on the design and the performance of the recently upgraded X-ray imaging spectrometer systems, X-ray imaging crystal spectrometer and high resolution X-ray imaging spectrometer, installed at the optimized stellarator Wendelstein 7-X. High resolution spectra of highly ionized, He-like Si, Ar, Ti, and Fe as well as H-like Ar have been observed. A cross comparison of ion and electron temperature profiles derived from a spectral fit and tomographic inversion of Ar and Fe spectra shows a reasonable match with both the spectrometers. The also measured impurity density profiles of Ar and Fe have peaked densities at radial positions that are in qualitative agreement with the expectations from the He-like impurity fractional abundances, given the measured temperature profiles. Repeated measurements of impurity decay times have been demonstrated with an accuracy of 1 ms via injection of non-recycling Ti, Fe, and Mo impurities using a laser blow-off system.

13.
Rev Sci Instrum ; 89(10): 10H115, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399932

ABSTRACT

A passive phased array Doppler reflectometry system has recently been installed in the Wendelstein-7X stellarator. In contrast to conventional Doppler reflectometry systems, the microwave beam can be steered on short time scales in the measurement plane perpendicular to the magnetic field in the range of ±25° without mechanical steering components. This paper characterizes the design and properties of the phased array antenna system and presents the first measurement results from the latest OP1.2a campaign.

14.
Rev Sci Instrum ; 88(3): 033509, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28372367

ABSTRACT

In magnetically confined fusion plasmas controlled gas injection is crucial for plasma fuelling as well as for various diagnostic applications such as active spectroscopy. We present a new, versatile system for the injection of collimated thermal gas beams into a vacuum chamber. This system consists of a gas pressure chamber, sealed by a custom made piezo valve towards a small capillary for gas injection. The setup can directly be placed inside of the vacuum chamber of fusion devices as it is small and immune against high magnetic fields. This enables gas injection close to the plasma periphery with high duty cycles and fast switch on/off times ≲ 0.5 ms. In this work, we present the design details of this new injection system and a systematic characterization of the beam properties as well as the gas flowrates which can be accomplished. The thin and relatively short capillary yields a small divergence of the injected beam with a half opening angle of 20°. The gas box is designed for pre-fill pressures of 10 mbar up to 100 bars and makes a flowrate accessible from 1018 part/s up to 1023 part/s. It hence is a versatile system for both diagnostic as well as fuelling applications. The implementation of this system in ASDEX Upgrade will be described and its application for line ratio spectroscopy on helium will be demonstrated on a selected example.

15.
Rev Sci Instrum ; 87(11): 11D304, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910389

ABSTRACT

Wendelstein 7-X, a superconducting optimized stellarator built in Greifswald/Germany, started its first plasmas with the last closed flux surface (LCFS) defined by 5 uncooled graphite limiters in December 2015. At the end of the 10 weeks long experimental campaign (OP1.1) more than 20 independent diagnostic systems were in operation, allowing detailed studies of many interesting plasma phenomena. For example, fast neutral gas manometers supported by video cameras (including one fast-frame camera with frame rates of tens of kHz) as well as visible cameras with different interference filters, with field of views covering all ten half-modules of the stellarator, discovered a MARFE-like radiation zone on the inboard side of machine module 4. This structure is presumably triggered by an inadvertent plasma-wall interaction in module 4 resulting in a high impurity influx that terminates some discharges by radiation cooling. The main plasma parameters achieved in OP1.1 exceeded predicted values in discharges of a length reaching 6 s. Although OP1.1 is characterized by short pulses, many of the diagnostics are already designed for quasi-steady state operation of 30 min discharges heated at 10 MW of ECRH. An overview of diagnostic performance for OP1.1 is given, including some highlights from the physics campaigns.

16.
Rev Sci Instrum ; 87(11): 11E729, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910540

ABSTRACT

This paper describes the design of the Thomson scattering system at the Wendelstein 7-X stellarator. For the first operation campaign we installed a 10 spatial channel system to cover a radial half profile of the plasma cross section. The start-up system is based on one Nd:YAG laser with 10 Hz repetition frequency, one observation optics, five fiber bundles with one delay line each, and five interference filter polychromators with five spectral channels and silicon avalanche diodes as detectors. High dynamic range analog to digital converters with 14 bit, 1 GS/s are used to digitize the signals. The spectral calibration of the system was done using a pulsed super continuum laser together with a monochromator. For density calibration we used Raman scattering in nitrogen gas. Peaked temperature profiles and flat density profiles are observed in helium and hydrogen discharges.

SELECTION OF CITATIONS
SEARCH DETAIL
...