Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Language
Publication year range
1.
Clin. transl. oncol. (Print) ; 25(4): 912-932, abr. 2023. ilus, tab
Article in English | IBECS | ID: ibc-217751

ABSTRACT

The present document includes consensus-based recommendations from the Brachytherapy Group (GEB) of the Spanish Society of Radiation Oncology (SEOR) and the Spanish Society of Medical Physics (SEFM) for interstitial high-dose-rate (HDR) brachytherapy (BT) for gynaecologic malignancies. A nine-item survey—which included questions on experience with interstitial BT; indications and technique; applicator type; magnetic resonance imaging (MRI)-based planning; dose; fractionation schedule; and treatment planning—was sent to all radiation oncology departments (n = 174) in Spain in 2021. Responses were received from 36 centres (50% of all centres [n = 72] with a BT unit). The consensus-based recommendations presented here are based on a review of the available literature, professional experience among the group of experts, and in-person discussions held during the annual meeting of these two societies. We describe the results of the survey and the following: indications; contraindications; patient selection; description of applicators; role of imaging in planning; contouring; dose prescription; dosimetric reconstruction; optimisation; and dose indications for cancers of the cervix, vagina, and vulva. The various clinical scenarios in which interstitial BT is used in the treatment of gynaecological tumours are described in detail, including cervix intracavitary/interstitial hybrid HDR-BT; cervix perineal templates/freehand implants; primary vaginal malignancies/vaginal recurrences; and vulvar interstitial implants (AU)


Subject(s)
Humans , Female , Brachytherapy/methods , Genital Neoplasms, Female/radiotherapy , Radiotherapy Dosage , Antineoplastic Protocols , Societies, Medical , Spain
3.
Clin Transl Oncol ; 25(4): 912-932, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36445642

ABSTRACT

The present document includes consensus-based recommendations from the Brachytherapy Group (GEB) of the Spanish Society of Radiation Oncology (SEOR) and the Spanish Society of Medical Physics (SEFM) for interstitial high-dose-rate (HDR) brachytherapy (BT) for gynaecologic malignancies. A nine-item survey-which included questions on experience with interstitial BT; indications and technique; applicator type; magnetic resonance imaging (MRI)-based planning; dose; fractionation schedule; and treatment planning-was sent to all radiation oncology departments (n = 174) in Spain in 2021. Responses were received from 36 centres (50% of all centres [n = 72] with a BT unit). The consensus-based recommendations presented here are based on a review of the available literature, professional experience among the group of experts, and in-person discussions held during the annual meeting of these two societies. We describe the results of the survey and the following: indications; contraindications; patient selection; description of applicators; role of imaging in planning; contouring; dose prescription; dosimetric reconstruction; optimisation; and dose indications for cancers of the cervix, vagina, and vulva. The various clinical scenarios in which interstitial BT is used in the treatment of gynaecological tumours are described in detail, including cervix intracavitary/interstitial hybrid HDR-BT; cervix perineal templates/freehand implants; primary vaginal malignancies/vaginal recurrences; and vulvar interstitial implants.


Subject(s)
Brachytherapy , Genital Neoplasms, Female , Radiation Oncology , Uterine Cervical Neoplasms , Vaginal Neoplasms , Female , Humans , Genital Neoplasms, Female/radiotherapy , Brachytherapy/methods , Radiotherapy Dosage , Physics , Radiotherapy Planning, Computer-Assisted/methods
4.
Brachytherapy ; 21(4): 389-396, 2022.
Article in English | MEDLINE | ID: mdl-35246391

ABSTRACT

INTRODUCTION: This study analyzes cases in which electronic brachytherapy (eBT) led to acceptable treatment plans in cervical cancer. Findings were compared with dosimetry values obtained in 192Ir-based treatments according to the high-risk clinical target volume (HR-CTV) and the disease stage. MATERIAL AND METHODS: We retrospectively analyzed 48 patients with cervical cancer from two centers. The patients were treated with 192Ir based on MRI. It was possible to use interstitial needles via an Utrecht-type applicator. Dosimetry was simulated using eBT and the parameters D90 and D98 (HR-CTV) and D2cc, D1cc, and D0.1cc (bladder, rectum, and sigmoid colon) were evaluated. The Mann-Whitney U test was used for comparison. The overall cohort of patients was analyzed, as were the sub-cohorts based on stage (FIGO stages I+IIA, IIB and III-IV). Finally, the dosimetry of the eBT plans was evaluated, and the plans obtained were classified as "good", "acceptable", or "poor". RESULTS: Statistically significant differences were found between the eBT and 192Ir plans for D98 (HR-CTV), D1cc and D0.1cc (bladder), and D1cc and D0.1cc (sigmoid colon). A total of 31 cases (64.6%) were considered good, seven (14.6%) were considered acceptable, and 10 (20.8%) were considered poor. For volumes <30 cc, all the plans were good or acceptable; for volumes >30 cc, 54.3% were good, and 71.4% were good or acceptable. By stage, eBT plans for patients with stage IB-IIA disease were good in 100%, whereas those for patients with stage IIB were good in 70.6% and III-IV disease were good in 50%. CONCLUSIONS: eBT provides appropriate dosimetry for treatment of cervical cancer in selected cases.


Subject(s)
Brachytherapy , Uterine Cervical Neoplasms , Brachytherapy/methods , Electronics , Feasibility Studies , Female , Humans , Organs at Risk , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Retrospective Studies , Tomography, X-Ray Computed/methods , Uterine Cervical Neoplasms/radiotherapy
SELECTION OF CITATIONS
SEARCH DETAIL