ABSTRACT

BACKGROUND: Balloon aortic valvuloplasty (BAV) has gained renewed interest as a bridge to transcatheter aortic valve replacement (TAVR) for patients with aortic stenosis (AS). However, it is unclear whether they patients should undergo TAVR directly or receive a staged bridge to BAV before TAVR is unclear. We used a national database to examine the association between BAV and TAVR in patients with TAVR and its effect on in-hospital mortality. METHODS: Using the nationwide inpatient database of the Japanese registry of all cardiac and vascular diseases and the combination of the diagnosis procedure combination, we retrospectively analyzed 27,600 patients with AS who underwent TAVR between October 2013 and March 2021. Outcomes of the direct TAVR group (n = 27,387) were compared with those of the BAV bridge to TAVR group (n = 213), which received BAV at least 1 day before TAVR. RESULTS: The median age was 85 (interquartile range: 82-88) years, with 33.3% (n = 9188) being male. Unplanned/emergent admissions increased with TAVR, whereas the use of BAV bridge to TAVR decreased. The in-hospital mortality rate was 1.3% and decreased over time. However, the BAV bridge to TAVR had a significantly higher in-hospital mortality than direct TAVR (5.6% vs. 1.3%; p < .0001). Factors associated with in-hospital mortality included age, body mass index, chronic renal disease, percutaneous coronary intervention, and BAV bridge to TAVR. CONCLUSIONS: In unplanned/emergent and planned admission settings, the in-hospital mortality rate for BAV bridge to TAVR is worse than that for direct TAVR. Practical criteria for BAV bridge to TAVR should be proposed to improve outcomes.


Subject(s)
Aortic Valve Stenosis , Balloon Valvuloplasty , Hospital Mortality , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/trends , Male , Female , Hospital Mortality/trends , Aged, 80 and over , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Retrospective Studies , Balloon Valvuloplasty/mortality , Balloon Valvuloplasty/trends , Aged , Japan/epidemiology
4.
Am J Cardiol ; 195: 28-36, 2023 05 15.
Article in English | MEDLINE | ID: mdl-37003082

ABSTRACT

We sought to clarify characteristics of patients with severe aortic stenosis (AS) in whom transvalvular mean pressure gradient (MPG) was underestimated with Doppler compared with catheterization. Study subjects included 127 patients with severe AS who underwent transcatheter aortic valve implantation. Between subjects with Doppler MPG underestimation ≥10 mm Hg (group U) and those without (group C), we retrospectively compared echocardiographic parameters and aortic valve calcification score using the Agatston method. Despite a strong correlation (rS = 0.88) and small absolute difference (2.1 ± 10.1 mm Hg) between Doppler and catheter MPG, 27 patients (21%) were in group U. Among 48 patients with catheter MPG ≥60 mm Hg, 10 patients (21%) revealed Doppler MPG of 40 to 59 mm Hg, suggesting they had been misclassified as having severe AS instead of very severe AS. According to the guidelines, indication of valve replacement for patients without symptoms should be considered for very severe AS but not for severe AS. Therefore, sole reliance on Doppler MPG could cause clinical misjudgments. Group U had larger relative wall thickness (median [interquartile range: 0.60 [0.50 to 0.69] vs 0.53 [0.46 to 0.60], p = 0.003) and higher calcification score (3,024 [2,066 to 3,555] vs 1,790 [1,293 to 2,501] arbitrary units, p <0.001). Both calcification score (per 100 arbitrary unit increment, odds ratio 1.10, 1.04 to 1.17, p = 0.002) and relative wall thickness (per 0.05 increment, odds ratio 1.29, 95% confidence interval 1.05 to 1.60, p = 0.02) were independently associated with Doppler underestimation. In conclusion, Doppler might underestimate transvalvular gradient compared with catheterization in patients with severe AS who have heavy valve calcification and prominent concentric remodeling left ventricular geometry.


Subject(s)
Aortic Valve Stenosis , Echocardiography, Doppler , Humans , Retrospective Studies , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Cardiac Catheterization
5.
ESC Heart Fail ; 10(2): 1336-1346, 2023 04.
Article in English | MEDLINE | ID: mdl-36725669

ABSTRACT

AIMS: This study aimed to clarify the relationship between cardiovascular prognosis and left ventricular hypertrophy (LVH) in patients with severe aortic stenosis who underwent transcatheter aortic valve replacement (TAVR) and to investigate the relationship between cardiac sympathetic nerve (CSN) function and these factors using 123 I-metaiodobenzylguanidine scintigraphy. METHODS AND RESULTS: In this single-centre, retrospective observational study, 349 patients who underwent TAVR at our institution between July 2017 and May 2020 were divided into two groups: those with severe LVH pre-operatively [severe LVH (+) group] and those without LVH pre-operatively [severe LVH (-) group]. The rates of freedom from cardiovascular events (cardiovascular death and heart failure hospitalization) were compared. The relationship between changes in left ventricular mass index (LVMi) and changes in delay heart-mediastinum ratio (H/M) from before TAVR to 6 months after TAVR was also investigated. The event-free rate was significantly lower in the severe LVH (+) group (87.1% vs. 96.0%, log-rank P = 0.021). The severe LVH (+) group exhibited a significantly lower delay H/M value, scored by 123 I-metaiodobenzylguanidine scintigraphy, than the severe LVH (-) group (2.33 [1.92-2.67] vs. 2.67 [2.17-3.68], respectively, P < 0.001). Moreover, the event-free rate of post-operative cardiovascular events was lower among patients with a delay H/M value < 2.50 than that among other patients (87.7% vs. 97.2%, log-rank P = 0.012). LVMi was significantly higher (115 [99-130] vs. 90 [78-111] g/m2 , P < 0.001) and delay H/M value was significantly lower (2.53 [1.98-2.83] vs. 2.71 [2.25-3.19], P = 0.025) in the severe LVH (+) group than in the severe LVH (-) group at 6 months after TAVR. Patients with improved LVH at 6 months after TAVR also had increased delay H/M (from 2.51 [2.01-2.81] to 2.67 [2.26-3.02], P < 0.001), whereas those without improved LVH had no significant change in delay H/M (from 2.64 [2.23-3.06] to 2.53 [1.97-3.00], P = 0.829). CONCLUSIONS: Severe LVH before TAVR is a prognostic factor for poor post-operative cardiovascular outcomes. LVH associated with aortic stenosis and CSN function are correlated, suggesting their involvement in LVH prognosis.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Hypertrophy, Left Ventricular/diagnosis , Hypertrophy, Left Ventricular/epidemiology , Hypertrophy, Left Ventricular/complications , Mediastinum/surgery , Treatment Outcome , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery
6.
Int J Cardiovasc Imaging ; 38(8): 1741-1750, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35211830

ABSTRACT

During transfemoral (TF) or transcatheter aortic valve replacement (TAVR), transesophageal echocardiography (TEE) sometimes reveals an unexpected mobile membranous mass on the catheter tip within the proximal part of the descending thoracic aorta. Such mobile masses may cause critical embolic events if the TAVR device advances into the ascending aorta in the absence of preventive measures. This study aimed to investigate the incidence and predictors of emboligenic matter (EM) during TAVR, impact of EM on the procedure, and incidence of symptomatic ischemic stroke post procedure. Among 436 consecutive patients who underwent TF-TAVR, 407 were evaluated in this study. The primary end point was incidence of symptomatic ischemic stroke within 24 h post procedure while taking appropriate preventive measures. Incidence of EM, factors associated with EM, and the impact of EM on the procedure were also investigated. Among the 407 cases, 15 cases (3.7%) of EM were identified but no ischemic stroke occurred in the EM (+) group (0% vs. 2.04%, p = 1.00). In the EM (+) group, a self-expandable valve was used in all 15 cases (100% vs. 42.6%, p < 0.0001) while 14 cases used a CoreValve's InLine sheath system initially (93.3% vs. 27.3%, p < 0.0001). CoreValve's InLine sheath system usage was the only independent predictor of EM. The CoreValve's InLine delivery system was identified as a predictor of EM during TF-TAVR, but symptomatic ischemic stroke was avoided while taking appropriate embolization preventive measures.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Ischemic Stroke , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Echocardiography, Transesophageal , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/epidemiology , Incidence , Treatment Outcome , Risk Factors , Predictive Value of Tests , Ischemic Stroke/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
7.
J Nucl Cardiol ; 29(5): 2652-2663, 2022 Oct.
Article in English | MEDLINE | ID: mdl-34561849

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) can rapidly improve cardiac sympathetic nervous function (CSNF) within 2 weeks in patients with aortic stenosis (AS). However, whether such short-term improvements will be sustained thereafter remains unclear. METHODS: Patients with severe AS who underwent TAVR between October 2017 and June 2019 were enrolled in this single-center, prospective, observational study. 123I-meta-iodobenzylguanidine imaging was performed at baseline, within 2 weeks after TAVR, and at 6 to 12 months post-TAVR to evaluate the heart-mediastinum ratio (H/M) and washout rate. RESULTS: Of 183 consecutive patients, 75 (19 men; median age: 86 years) were evaluated. The late H/M significantly improved within 2 weeks after TAVR (P = .041) and further improved over 6 to 12 months after TAVR (P = .041). Multivariate analysis revealed that the baseline mean aortic valve pressure gradient (mPG) was an independent predictor of mid-term improvement in the late H/M (> 0.1) (P = .037). Patients with a high baseline mPG (≥ 58 mmHg) exhibited a significantly greater increase in the late H/M than those with a low baseline mPG (< 42 mmHg) (0.24 vs 0.01; P = .029). CONCLUSION: CSNF demonstrated sustained improvement from within 2 weeks after TAVR until 6 to 12 months later. Such improvement was related to baseline hemodynamic AS severity.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , 3-Iodobenzylguanidine , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Iodine Radioisotopes , Male , Prospective Studies , Risk Factors , Severity of Illness Index , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
8.
Eur Heart J Case Rep ; 5(12): ytab484, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34909575

ABSTRACT

BACKGROUND: Spontaneous coronary artery rupture (SCAR) is an extremely rare and highly lethal disease. CASE SUMMARY: A 74-year-old man who had undergone respiratory surgery (robot-assisted thoracoscopic surgery) presented with exertional dyspnoea since postoperative day (POD) 6. Echocardiography and contrast-enhanced computed tomography showed diffuse pericardial effusion, and a 12-lead electrocardiogram showed widespread concave ST-segment elevation. The diagnosis of acute pericarditis was made based on the absence of significant elevation of cardiac enzymes and the presence of elevated C-reactive peptide levels. The patient was started on anti-inflammatory medication, including steroids; however, on POD 11, the patient developed a sudden cardiopulmonary arrest due to cardiac tamponade. Extracorporeal cardiopulmonary resuscitation was performed, and an emergency coronary angiography showed contrast extravasation from the left anterior descending artery to the epicardium. He was diagnosed with SCAR and underwent transcatheter arterial embolization (TAE) and pericardial drainage. DISCUSSION: In this case, SCAR occurred during the course of acute pericarditis. We speculated that the cause of SCAR was more affected with pericarditis than injury by the respiratory surgery. The clinical course of acute pericarditis generally has a good prognosis, but the rare occurrence of fatal complications should be considered, suggesting the need for careful follow-up. In addition, TAE was a less invasive and feasible treatment for SCAR.

10.
Int J Cardiovasc Imaging ; 37(1): 15-23, 2021 Jan.
Article in English | MEDLINE | ID: mdl-32734495

ABSTRACT

The purpose of this study was to evaluated the clinical characteristics of calcified nodule-like in-stent restenosis (ISR) lesions using optical coherence tomography (OCT) in vivo. A total of 124 ISR lesions that were treated with a repeat coronary intervention under OCT guidance were included in this analysis. ISR neointimal morphology was classified as "calcified nodule-like ISR", that appeared as a high-backscattering protruding mass with an irregular surface covered by signal-rich bands, or "non-calcified nodule-like ISR". The maximum arc and thickness of calcium behind the stent struts was also measured. Of the 124 ISR lesions, calcified nodule-like ISR was observed in 11 lesions (9%). OCT analysis data showed that the maximum arc of calcium and the maximum calcium thickness behind the stent were significantly larger in the calcified nodule-like ISR lesions than in the non-calcified nodule-like ISR lesions (269 ± 51 vs. 179 ± 92°, p < 0.01 and 989 ± 174 vs. 684 ± 241 µm, p < 0.01, respectively). The enlargement of the stent area was significantly larger in the calcified nodule-like ISR lesions than in the non-calcified nodule-like ISR lesions (1.6 ± 2.3 vs. 0.7 ± 1.3 mm2, p = 0.02). As a result, the enlargement of the lumen area tended to be larger in the calcified group (2.8 ± 1.7 vs. 2.4 ± 1.3 mm2, p = 0.3). Calcified nodule-like neointima within the stent could develop in approximately 10% of all ISR lesions, especially within stents deployed in severely calcified lesions.


Subject(s)
Coronary Artery Disease/therapy , Coronary Restenosis/diagnostic imaging , Coronary Vessels/diagnostic imaging , Percutaneous Coronary Intervention/instrumentation , Stents , Tomography, Optical Coherence , Vascular Calcification/diagnostic imaging , Aged , Aged, 80 and over , Coronary Artery Disease/diagnostic imaging , Coronary Restenosis/etiology , Female , Humans , Male , Middle Aged , Neointima , Percutaneous Coronary Intervention/adverse effects , Predictive Value of Tests , Retrospective Studies , Risk Factors , Treatment Outcome , Vascular Calcification/etiology
11.
J Atheroscler Thromb ; 28(4): 365-374, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-32669483

ABSTRACT

AIMS: This study aimed to assess the clinical efficacy of intravascular ultrasound (IVUS)-guided intraplaque wiring for femoropopliteal (FP) chronic total occlusion (CTO). METHODS: This single-center, retrospective, observational study was performed at the Japanese Red Cross Kyoto Daini Hospital. From March 2013 to June 2017, a total of 75 consecutive patients (mean age: 75.4±8.5 years; 59 males), who underwent endovascular treatment (EVT), having 82 de novo FP-CTO lesions, were enrolled in this study. Eleven of the lesions that met the exclusion criteria were excluded, and the remaining 71 lesions were divided into the IVUS-guided wiring group (n=34) and non-IVUS-guided wiring group (n=37). Primary patency, defined as a peak systolic velocity ratio of <2.4 on duplex ultrasonography, and freedom from clinically driven target lesion revascularization (CD-TLR) at 12 months were the primary outcomes. RESULTS: The mean lesion length was 21.6±8.9 cm. The frequencies of primary patency and freedom from CD-TLR were significantly higher in the IVUS-guided wiring group than in the non-IVUS-guided wiring group (70.0% vs. 52.2%, p=0.045; 83.9% vs. 62.8%, p=0.036, respectively). The complete clinically true lumen angioplasty rate was also higher in the IVUS-guided wiring group than in the non-IVUS-guided wiring group (91.1% vs. 51.3%, p<0.001, respectively). The clinically true and false wire passage rates were respectively 97.3% and 2.7% in the IVUS-guided wiring group. CONCLUSION: IVUS-guided wiring improves the clinical outcomes of EVT for FP-CTO by achieving a high clinically true lumen wire passage rate.


Subject(s)
Angioplasty , Arterial Occlusive Diseases , Endovascular Procedures , Femoral Artery , Popliteal Artery , Ultrasonography, Interventional/methods , Aged , Angioplasty/adverse effects , Angioplasty/methods , Arterial Occlusive Diseases/diagnosis , Arterial Occlusive Diseases/epidemiology , Arterial Occlusive Diseases/physiopathology , Arterial Occlusive Diseases/surgery , Chronic Disease , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Female , Femoral Artery/diagnostic imaging , Femoral Artery/pathology , Femoral Artery/surgery , Humans , Japan/epidemiology , Male , Outcome Assessment, Health Care , Popliteal Artery/diagnostic imaging , Popliteal Artery/pathology , Popliteal Artery/surgery , Quality Improvement , Reoperation/methods , Reoperation/statistics & numerical data , Severity of Illness Index , Surgery, Computer-Assisted/methods , Surgery, Computer-Assisted/standards , Vascular Patency