Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Endosc ; 2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38549245

ABSTRACT

Background/Aims: Endoscopic ultrasound (EUS)-guided hepaticogastrostomy (EUS-HGS) performed at the intrahepatic bile duct segment 3 (B3) is widely used for biliary drainage. Although performing post-puncture procedures is easier in the intrahepatic bile duct segment 2 (B2) when using a conventional oblique-viewing (OV) EUS scope, this method may cause transesophageal puncture and severe adverse events. We evaluated the safety and efficacy of B2 puncture using a novel OV-EUS scope. Methods: In this single-center retrospective study, we prospectively enrolled and collected data from 45 patients who consecutively underwent EUS-HGS procedures with a novel OV-EUS scope between September 2021 and December 2022 at our cancer center. Results: The technical success rates of B2-EUS-HGS and EUS-HGS were 93.3% (42/45) and 97.8% (44/45), respectively. The early adverse event rate was 8.9% (4/45) with no cases of scope changes or transesophageal punctures. The median procedure time was 13 minutes (range, 5-30). Conclusions: B2-EUS-HGS can be performed safely with the novel EG-740UT (Fujifilm) OV-scope without transesophageal puncture and with a high success rate. B2-EUS-HGS using this novel OV scope may be the preferred strategy for EUS-HGS.

2.
Intern Med ; 2024 Feb 26.
Article in English | MEDLINE | ID: mdl-38403760

ABSTRACT

Objective Adverse events such as bile leakage and bleeding are among the issues that need to be resolved in EUS-guided choledochoduodenostomy (EUS-CDS). To overcome this problem, we developed a new EUS-CDS technique using a 19-G Franseen needle without tract dilation. This study aimed to evaluate the safety and efficacy of the new EUS-CDS technique. Methods This single-center retrospective study included 20 consecutive patients who underwent EUS-CDS for primary drainage using a 19-G Franseen needle between March 2020 and May 2023. The primary endpoint was the technical success rate of EUS-CDS without tract dilation. Results The technical success rate of EUS-CDS was 20/20 (100%). None of the patients required any additional tract dilation, such as by using a balloon or electric cautery. The median procedure time was 7.8 (range, 3.2-19.4) min. No early adverse events were observed. Conclusion The 19-G Franseen needle appeared to have a sufficient dilatory effect during puncturing. This EUS-CDS technique appears to be safe and effective and has the advantages of no adverse events and it is also a simplified procedure, which suggests its potential for widespread use in primary drainage.

3.
Dig Endosc ; 36(2): 206-214, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37186389

ABSTRACT

OBJECTIVES: Endoscopic ultrasound-guided fine-needle aspiration and fine-needle biopsy (EUS-FNA/FNB) is not fully established as a pathological sampling tool for gallbladder lesions due to limited evidence. We therefore aimed to clarify the effectiveness and safety of this procedure in a large-population cohort. METHODS: This study retrospectively evaluated the diagnostic yield of EUS-FNA/FNB for accurately differentiating between benign and malignant gallbladder lesions. Puncture targets included the gallbladder mass, lymph node, and liver mass. Adverse events and factors associated with diagnostic accuracy were analyzed as well. RESULTS: In 187 patients with gallbladder lesions undergoing EUS-FNA/FNB, 18 benign lesions and 169 malignant lesions were identified. Overall sampling adequacy was 98% (184/187). The diagnostic accuracy of EUS-FNA/FNB was 97% (182/187), sensitivity was 97% (164/169), and specificity was 100% (18/18). A single postprocedural complication (minor bleeding) was recorded in one patient. In the 169 cases of malignancy, 203 sites were punctured for pathological sampling of the primary mass (n = 94), lymph node (n = 79), and metastatic liver mass (n = 30). No significant difference was found for diagnostic accuracy among the puncture sites (P = 0.70). In cases having specimens obtained from the primary mass, the accuracy of those targeting liver invasion sites was significantly higher than that of other sites (98% vs. 83%, P < 0.01). CONCLUSION: EUS-FNA/FNB demonstrated clinical usefulness and safety for the pathological diagnosis of gallbladder lesions, with high diagnostic yield and a low incidence of adverse events. Targeting the site of liver infiltration may improve the diagnostic rate of EUS-FNA/FNB in the primary mass.


Subject(s)
Endoscopic Ultrasound-Guided Fine Needle Aspiration , Pancreatic Neoplasms , Humans , Endoscopic Ultrasound-Guided Fine Needle Aspiration/methods , Gallbladder/pathology , Retrospective Studies , Pancreatic Neoplasms/pathology
4.
Clin Endosc ; 57(2): 246-252, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37743069

ABSTRACT

BACKGROUND/AIMS: Endoscopic ultrasound (EUS)-guided hepaticogastrostomy (EUS-HGS) is useful for patients with biliary cannulation failure or inaccessible papillae. However, it can lead to serious complications such as bile peritonitis in patients with ascites; therefore, development of a safe method to perform EUS-HGS is important. Herein, we evaluated the safety of EUS-HGS with continuous ascitic fluid drainage in patients with ascites. METHODS: Patients with moderate or severe ascites who underwent continuous ascites drainage, which was initiated before EUS-HGS and terminated after the procedure at our institution between April 2015 and December 2022, were included in the study. We evaluated the technical and clinical success rates, EUS-HGS-related complications, and feasibility of re-intervention. RESULTS: Ten patients underwent continuous ascites drainage, which was initiated before EUS-HGS and terminated after completion of the procedure. Median duration of ascites drainage before and after EUS-HGS was 2 and 4 days, respectively. Technical success with EUS-HGS was achieved in all 10 patients (100%). Clinical success with EUS-HGS was achieved in 9 of the 10 patients (90 %). No endoscopic complications such as bile peritonitis were observed. CONCLUSION: In patients with ascites, continuous ascites drainage, which is initiated before EUS-HGS and terminated after completion of the procedure, may prevent complications and allow safe performance of EUS-HGS.

5.
Clin Endosc ; 2023 Sep 12.
Article in English | MEDLINE | ID: mdl-37743070

ABSTRACT

Background/Aims: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is a highly accurate method for diagnosing pancreatic neuroendocrine tumors (PNETs); however, some PNETs are difficult to diagnose. Recently, the efficacy of needle-based confocal laser endomicroscopy (nCLE) in diagnosing solid pancreatic masses has been reported. However, the efficacy of nCLE in the diagnosis of PNETs remains unknown and only a small number of cases have been reported. Hence, this study aimed to evaluate the efficacy of nCLE in the diagnosis of PNETs. Methods: This single-center retrospective study evaluated 30 consecutive patients with suspected PNETs on contrast-enhanced computed tomography, who consented to nCLE combined with EUS-FNA and were diagnosed using EUS-FNA or surgical resection. The diagnostic criteria for PNETs using nCLE were based on the nesting and trabecular and glandular arrangement of tumor cell clusters surrounded by capillary vessels and fibrosis, as reported in previous studies. Results: The diagnosis using nCLE was classified into three categories: misdiagnosis in three cases (10%), non-diagnostic in six cases (20%), and diagnostic in 21 cases (70%). nCLE was able to diagnose PNET in one of the two cases with inconclusive EUS-FNA. Conclusions: Although further development of the resolution and optimization of the diagnostic criteria are required, nCLE may constitute a useful diagnostic option in cases of inconclusive EUS-FNA for PNETs.

6.
DEN Open ; 3(1): e236, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37125072

ABSTRACT

Objectives: We evaluated the safety and efficacy of aggressive hydration with rectal non-steroidal anti-inflammatory drugs for the prevention of post-endoscopic retrograde cholangiopancreatography (ERCP) pancreatitis (PEP). Methods: This prospective, single-arm, multicenter trial was conducted at 12 institutions between October 2020 and August 2021. We enrolled 231 patients who had intact papillae and were scheduled to undergo ERCP. All patients were administered rectal diclofenac before ERCP. They received aggressive hydration with intravenous lactated Ringer's solution in an initial bolus of 5 ml/kg at the start of ERCP, followed by 3 ml/kg/h for 8 h after the procedure. The primary outcome was the occurrence of PEP. Secondary outcomes included PEP severity, hyperamylasemia, and adverse events. Results: The mean age of the patients was 68.8 ± 13.7 years, and 81 patients (35.1%) were 75 years or older. Thirteen patients developed PEP (5.6%, 95% confidence interval 3.0%-9.4%). There were 11 cases (4.8%) of mild pancreatitis and two cases (0.9%) of severe pancreatitis. Forty-five patients (19.5%) developed hyperamylasemia and one patient developed non-severe peripheral edema. Conclusions: Aggressive hydration combined with rectal diclofenac may be a promising strategy for the prevention of PEP. Furthermore, it is safe even for older individuals.

7.
Dig Endosc ; 35(3): 389-393, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36170547

ABSTRACT

Tract dilation is one of the most difficult stages of endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS), especially for beginners. To overcome this problem, we applied a special dedicated dilator. Herein, we retrospectively evaluate the safety and usefulness of a novel drill dilator in EUS-HGS. This single-center retrospective study included 20 consecutive patients who underwent EUS-HGS with a novel drill dilator. The tip is 0.77 mm, and it becomes 7F at 3 cm from tip. The track is dilated to 7F by simple clockwise rotation. The technical success rate of both initial tract dilation and stent placement was 20/20 (100%). No cases required additional dilation such as balloon or electric cautery. In 13/20 cases (65.0%), EUS-HGS was performed by beginner endoscopists. Median time required for dilation was 62.5 s (range, 30-144 s). Median procedure time was 13 min (range, 7-25 min). Early adverse events were two cases of mild fever. There was no bile leakage or bleeding. The novel drill dilator appears to be safe and useful for EUS-HGS. As it is not necessary to press the device strongly, there is no pushback during dilation and the scope position is stable. These characteristics facilitate EUS-HGS even for beginners. This device may enable the further development and increased dissemination of EUS intervention.


Subject(s)
Biliary Tract Surgical Procedures , Cholestasis , Humans , Retrospective Studies , Drainage/methods , Liver , Biliary Tract Surgical Procedures/methods , Endosonography/methods , Ultrasonography, Interventional , Stents , Cholestasis/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...