Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
J Neurovirol ; 28(3): 355-366, 2022 06.
Article in English | MEDLINE | ID: mdl-35776340

ABSTRACT

Altered white matter microstructure has been reported repeatedly using diffusion tensor imaging (DTI) in HIV-associated neurocognitive disorders. However, the associations between neurocognitive deficits and impaired white matter remains obscure due to frequent physical and psychiatric comorbidities in the patients. Severe immune suppression, reflected by low nadir CD4 T-cell counts, is reported to be associated with the neurocognitive deficits in the patients. In the present study, we examined white matter integrity using DTI and tract-based spatial statistics (TBSS), and neurocognitive functions using a battery of tests, in 15 HIV-infected patients with low nadir CD4, 16 HIV-infected patients with high nadir CD4, and 33 age- and sex-matched healthy controls. As DTI measures, we analyzed fractional anisotropy (FA) and mean diffusivity (MD). In addition, we investigated the correlation between white matter impairments and neurocognitive deficits. Among the three participant groups, the patients with low nadir CD4 showed significantly lower performance in processing speed and motor skills, and had significantly increased MD in widespread regions of white matter in both hemispheres. In the patients with low nadir CD4, there was a significant negative correlation between motor skills and MD in the right motor tracts, as well as in the corpus callosum. In summary, this study may provide white matter correlates of neurocognitive deficits in HIV-infected patients with past severe immune suppression as legacy effects.


Subject(s)
HIV Infections , White Matter , Anisotropy , Corpus Callosum/diagnostic imaging , Diffusion Tensor Imaging , HIV Infections/complications , HIV Infections/diagnostic imaging , Humans , White Matter/diagnostic imaging
2.
J Neurovirol ; 26(4): 590-601, 2020 08.
Article in English | MEDLINE | ID: mdl-32572834

ABSTRACT

Although neuropsychological studies of human immunodeficiency virus (HIV)-infected patients have demonstrated heterogeneity in neurocognitive impairment and neuroimaging studies have reported diverse brain regions affected by HIV, it remains unclear whether individual differences in neurocognitive impairment are underpinned by their neural bases. Here, we investigated spatial distribution patterns of correlation between neurocognitive function and regional gray matter (GM) volume across patients with HIV. Thirty-one combination antiretroviral therapy-treated HIV-infected Japanese male patients and 33 age- and sex-matched healthy controls were included in the analysis after strict exclusion criteria, especially for substance use. Fifteen neurocognitive tests were used, and volumetric magnetic resonance imaging was performed. We used voxel-based morphometry to compare GM volume between groups and identify regional GM volumes that correlated with neurocognitive tests across patients. Using the Frascati criteria, 10 patients were diagnosed with asymptomatic neurocognitive impairment, while the others were not diagnosed with HIV-associated neurocognitive disorders. Patients showed a significantly lower performance in five neurocognitive tests as well as significantly reduced GM volume relative to controls, with volume-reduced regions spread diffusely across the whole brain. Different aspects of neurocognitive impairment (i.e., figural copy, finger tapping, and Pegboard) were associated with different GM regions. Our findings suggest a biological background constituting heterogeneity of neurocognitive impairment in HIV infection and support the clinical importance of considering individual differences for tailor-made medicine for people living with HIV.


Subject(s)
Anti-HIV Agents/therapeutic use , Cognitive Dysfunction/physiopathology , Gray Matter/physiopathology , HIV Infections/physiopathology , Adult , Antiretroviral Therapy, Highly Active , Asymptomatic Diseases , Attention/drug effects , Case-Control Studies , Cognitive Dysfunction/diagnostic imaging , Cognitive Dysfunction/drug therapy , Cognitive Dysfunction/virology , Executive Function/drug effects , Gray Matter/diagnostic imaging , Gray Matter/drug effects , Gray Matter/virology , Gyrus Cinguli/diagnostic imaging , Gyrus Cinguli/drug effects , Gyrus Cinguli/physiopathology , Gyrus Cinguli/virology , HIV Infections/diagnostic imaging , HIV Infections/drug therapy , HIV Infections/virology , Hippocampus/diagnostic imaging , Hippocampus/drug effects , Hippocampus/physiopathology , Hippocampus/virology , Humans , Magnetic Resonance Imaging , Male , Memory/drug effects , Mental Status and Dementia Tests , Middle Aged , Motor Skills/drug effects , Neuroimaging/methods , Occipital Lobe/diagnostic imaging , Occipital Lobe/drug effects , Occipital Lobe/physiopathology , Occipital Lobe/virology , Parietal Lobe/diagnostic imaging , Parietal Lobe/drug effects , Parietal Lobe/physiopathology , Parietal Lobe/virology , Prefrontal Cortex/diagnostic imaging , Prefrontal Cortex/drug effects , Prefrontal Cortex/physiopathology , Prefrontal Cortex/virology , Severity of Illness Index , Speech/drug effects
3.
Ann Nucl Med ; 28(9): 917-25, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25049112

ABSTRACT

OBJECTIVES: Thallium-201 ((201)Tl) single photon emission computed tomography (SPECT) is an important tool in the diagnosis of ischemic heart disease. Absolute quantification of myocardial blood flow (MBF) has the potential to provide more useful information on myocardial perfusion than semi-quantitative assessments. This study aimed to validate the quantification of MBF using (201)Tl cardiac SPECT based on a population-averaged input function (STD-IF) and one-point blood sample technique. METHODS: (201)Tl emission and computed tomography (CT)-based attenuation scans were performed on 11 healthy volunteers at rest using a SPECT/CT scanner. Individual input functions (IND-IFs) during the emission scans were based on arterial blood samples. The STD-IF technique was validated as follows: (1) optimal time to calibrate a STD-IF was determined to minimize differences between the calibrated STD-IF and the IND-IFs. (2) Tissue time-activity curves (TTACs) were generated based on a single-tissue compartment model for MBFtrue = 0.5, 1.0, 1.5, and 2.0 mL/min/g, a constant distribution volume of 45 mL/mL, and IND-IFs. The pseudo STD-IF for each subject was generated using the leave-one-out technique. Using the optimal calibration time and the pseudo STD-IFs, MBF values were estimated on the TTACs with an autoradiography method. Optimal mid-scan time (MST) with a fixed duration of 20 min was determined to minimize intersubject variation in estimated MBF errors, and (3) Global and regional MBF values estimated with pseudo STD-IFs were compared to those with IND-IFs using the optimal calibration time and MST. RESULTS: The optimal calibration time and MST were both 20 min after (201)Tl injection. Global MBF determined using both IND-IFs and pseudo STD-IF showed significant correlations with rate-pressure products, R (2) = 0.645; p < 0.01 and R (2) = 0.303; p < 0.05, respectively. The mean percent error in regional MBF using pseudo STD-IFs was 0.69 ± 7.80 % (-12.80 to 14.25 %). No significant difference was observed between regional MBF values using IND-IFs and pseudo STD-IFs. CONCLUSION: This study demonstrated that the proposed technique based on a STD-IF and one-point blood sample provided hemodynamically reasonable global MBF values and the regional MBF values comparable to those with IND-IFs.


Subject(s)
Coronary Circulation , Heart/diagnostic imaging , Radioisotopes , Radiopharmaceuticals , Thallium , Tomography, Emission-Computed, Single-Photon/methods , Adolescent , Adult , Autoradiography/methods , Blood Pressure , Calibration , Computer Simulation , Female , Heart/physiology , Heart Rate , Humans , Male , Time Factors , Young Adult
4.
EJNMMI Res ; 2(1): 33, 2012 Jun 22.
Article in English | MEDLINE | ID: mdl-22726667

ABSTRACT

BACKGROUND: Attenuation correction of a single photon emission computed tomography (SPECT) image is possible using computed tomography (CT)-based attenuation maps with hybrid SPECT/CT. CT attenuation maps acquired during breath holding can be misaligned with SPECT, generating artifacts in the reconstructed images. The purpose of this study was to investigate the effects of respiratory phase during breath-hold CT acquisition on attenuation correction of cardiac SPECT imaging. METHODS: A series of 201Tl-emission and 99mTc-based transmission computed tomography (TCT) scans was carried out along with CT-attenuation scans on 11 young normal volunteers using a hybrid SPECT/CT scanner. The CT scans were performed at three respiratory phases: end-inspiration (INS), end-expiration (EXP), and the midpoint (MID) between these phases. Using alignment parameters between attenuation maps and SPECT images without attenuation or scatter corrections, quantitative SPECT images were reconstructed, including corrections for attenuation and scatter. Regional radioactivity concentrations normalized by the subjects' weights were compared between CT- and TCT-based attenuation correction techniques. RESULTS: SPECT images with CT attenuation maps at the EXP phase showed significant differences in regional weight-normalized radioactivity concentrations relative to the images using the other attenuation maps (p < 0.05), as well as systematic positive bias errors, compared to TCT-based images for all myocardial segments, 5.7% ± 2.7% (1.9% to 10.0%). No significant differences in regional weight-normalized radioactivity concentrations were observed between images with CT attenuation maps at MID and INS phases or between these and the TCT-based images, but regional tendencies were found: for anterior to anterolateral segment, positive bias of 5.0% ± 2.2% (1.3% to 8.1%) and 5.6% ± 1.9% (2.6% to 8.5%) and for inferior to inferoseptal segment, negative bias of -5.3% ± 2.6% (-9.1% to -1.7%) and -4.6% ± 2.5% (-8.8% to -1.5%) for the MID and INS phases, respectively. CONCLUSIONS: Use of breath-hold CT attenuation maps at INS and MID phases for attenuation and scatter corrections demonstrated accurate quantitative images that would prove beneficial in cardiac SPECT/CT studies.

SELECTION OF CITATIONS
SEARCH DETAIL