Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Arch Dis Child ; 97(3): 221-6, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22247242

ABSTRACT

OBJECTIVE: To undertake a cost-effectiveness analysis that compares pulse oximetry as an adjunct to clinical examination with clinical examination alone in newborn screening for congenital heart defects (CHDs). DESIGN: Model-based economic evaluation using accuracy and cost data from a primary study supplemented from published sources taking an NHS perspective. SETTING: Six large maternity units in the UK. PATIENTS: 20 055 newborn infants prior to discharge from hospital. INTERVENTION: Pulse oximetry as an adjunct to clinical examination. MAIN OUTCOME MEASURE: Cost effectiveness based on incremental cost per timely diagnosis. RESULTS: Pulse oximetry as an adjunct to clinical examination is twice as costly but provides a timely diagnosis to almost 30 additional cases of CHD per 100 000 live births compared with a modelled strategy of clinical examination alone. The incremental cost-effectiveness ratio for this strategy compared with clinical examination alone is approximately £24 000 per case of timely diagnosis in a population in which antenatal screening for CHDs already exists. The probabilistic sensitivity analysis suggests that at a willingness-to-pay (WTP) threshold of £100 000, the probability of 'pulse oximetry as an adjunct to clinical examination' being cost effective is more than 90%. Such a WTP threshold is plausible if a newborn with timely diagnosis of a CHD gained just five quality-adjusted life years, even when treatment costs are taken into consideration. CONCLUSION: Pulse oximetry as an adjunct to current routine practice of clinical examination alone is likely to be considered a cost-effective strategy in the light of currently accepted thresholds.


Subject(s)
Heart Defects, Congenital/diagnosis , Neonatal Screening/economics , Oximetry/economics , Cost-Benefit Analysis , Health Care Costs/statistics & numerical data , Health Resources/statistics & numerical data , Heart Defects, Congenital/economics , Heart Defects, Congenital/epidemiology , Humans , Infant, Newborn , Models, Econometric , Neonatal Screening/methods , United Kingdom/epidemiology
2.
Health Technol Assess ; 16(2): v-xiii, 1-184, 2012.
Article in English | MEDLINE | ID: mdl-22284744

ABSTRACT

BACKGROUND: Screening for congenital heart defects (CHDs) relies on antenatal ultrasound and postnatal clinical examination; however, life-threatening defects often go undetected. OBJECTIVE: To determine the accuracy, acceptability and cost-effectiveness of pulse oximetry as a screening test for CHDs in newborn infants. DESIGN: A test accuracy study determined the accuracy of pulse oximetry. Acceptability of testing to parents was evaluated through a questionnaire, and to staff through focus groups. A decision-analytic model was constructed to assess cost-effectiveness. SETTING: Six UK maternity units. PARTICIPANTS: These were 20,055 asymptomatic newborns at ≥ 35 weeks' gestation, their mothers and health-care staff. INTERVENTIONS: Pulse oximetry was performed prior to discharge from hospital and the results of this index test were compared with a composite reference standard (echocardiography, clinical follow-up and follow-up through interrogation of clinical databases). MAIN OUTCOME MEASURES: Detection of major CHDs - defined as causing death or requiring invasive intervention up to 12 months of age (subdivided into critical CHDs causing death or intervention before 28 days, and serious CHDs causing death or intervention between 1 and 12 months of age); acceptability of testing to parents and staff; and the cost-effectiveness in terms of cost per timely diagnosis. RESULTS: Fifty-three of the 20,055 babies screened had a major CHD (24 critical and 29 serious), a prevalence of 2.6 per 1000 live births. Pulse oximetry had a sensitivity of 75.0% [95% confidence interval (CI) 53.3% to 90.2%] for critical cases and 49.1% (95% CI 35.1% to 63.2%) for all major CHDs. When 23 cases were excluded, in which a CHD was already suspected following antenatal ultrasound, pulse oximetry had a sensitivity of 58.3% (95% CI 27.7% to 84.8%) for critical cases (12 babies) and 28.6% (95% CI 14.6% to 46.3%) for all major CHDs (35 babies). False-positive (FP) results occurred in 1 in 119 babies (0.84%) without major CHDs (specificity 99.2%, 95% CI 99.0% to 99.3%). However, of the 169 FPs, there were six cases of significant but not major CHDs and 40 cases of respiratory or infective illness requiring medical intervention. The prevalence of major CHDs in babies with normal pulse oximetry was 1.4 (95% CI 0.9 to 2.0) per 1000 live births, as 27 babies with major CHDs (6 critical and 21 serious) were missed. Parent and staff participants were predominantly satisfied with screening, perceiving it as an important test to detect ill babies. There was no evidence that mothers given FP results were more anxious after participating than those given true-negative results, although they were less satisfied with the test. White British/Irish mothers were more likely to participate in the study, and were less anxious and more satisfied than those of other ethnicities. The incremental cost-effectiveness ratio of pulse oximetry plus clinical examination compared with examination alone is approximately £24,900 per timely diagnosis in a population in which antenatal screening for CHDs already exists. CONCLUSIONS: Pulse oximetry is a simple, safe, feasible test that is acceptable to parents and staff and adds value to existing screening. It is likely to identify cases of critical CHDs that would otherwise go undetected. It is also likely to be cost-effective given current acceptable thresholds. The detection of other pathologies, such as significant CHDs and respiratory and infective illnesses, is an additional advantage. Other pulse oximetry techniques, such as perfusion index, may enhance detection of aortic obstructive lesions. FUNDING: The National Institute for Health Research Health Technology programme.


Subject(s)
Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/epidemiology , Neonatal Screening/methods , Oximetry/standards , Adult , Analysis of Variance , Attitude of Health Personnel , Cohort Studies , Cost-Benefit Analysis , Echocardiography/economics , Female , Humans , Infant, Newborn , Male , Mothers/psychology , Neonatal Screening/economics , Neonatal Screening/psychology , Obstetrics and Gynecology Department, Hospital , Oximetry/economics , Oximetry/psychology , Patient Satisfaction , Risk Factors , Sensitivity and Specificity , Surveys and Questionnaires , United Kingdom/epidemiology , Young Adult
3.
J Neurol Neurosurg Psychiatry ; 80(9): 976-8, 2009 Sep.
Article in English | MEDLINE | ID: mdl-18339727

ABSTRACT

OBJECTIVE: To perform a pilot trial of occupational therapy (OT) to optimise functional independence in Parkinson disease (PD) to assess accrual/withdrawal rates, acceptability, outcome measures, and inform sample-size calculation. METHOD: Non-demented patients with idiopathic PD and difficulties with activities of daily living (ADL) were recruited provided they had not received OT in the last 2 years and/or physiotherapy in the last year. Patients were randomised to immediate OT or OT after completion of the trial. Patients randomised to OT were assessed at home by an experienced therapist and then received six home treatment sessions over 2 months. Interventions were targeted at functional independence and mobility goals. Outcome measures were: Nottingham Extended Activity of Daily Living Scale, Rivermead Mobility Index, Unified Parkinson's Disease Rating Scale ADL scale, Parkinson's Disease Questionnaire 39, EuroQol-EQ-5D, Hospital Anxiety and Depression Scale, and health economics analysis. RESULTS: 39 patients (25 male; mean age 73 years) were recruited from four centres over 16 months. The mean difference in NEADL at 8 months was 3.5 (95% CI -3.2 to 10.2). The mean difference in PDQ-39 Summary Score was 3.8 (95% CI -4.94 to 12.6). There were strong correlations between the PDQ-39 and other outcomes. The intervention was acceptable to patients, with a low withdrawal rate and good questionnaire completion. CONCLUSION: Randomisation to a trial of OT in PD is feasible. NEADL and PDQ-39 are relevant outcomes and provided data to inform sample size for an adequately powered randomised trial for which there is pressing need.


Subject(s)
Activities of Daily Living/psychology , Occupational Therapy , Parkinson Disease/psychology , Parkinson Disease/therapy , Aged , Anxiety/psychology , Depression/psychology , Female , Humans , Male , Occupational Therapy/economics , Parkinson Disease/economics , Pilot Projects , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL