Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 293
Filter
1.
Biosens Bioelectron ; 267: 116793, 2024 Sep 18.
Article in English | MEDLINE | ID: mdl-39316866

ABSTRACT

Pulse arrival time (PAT), Pulse transit time (PTT), and Pulse Wave Velocity (PWV) have all been used as metrics for assessing a number of cardiovascular applications, including arterial stiffness and cuffless blood pressure monitoring. These have been measured using various sensing methods, including electrocardiogram (ECG) with photoplethysmogram (PPG), two PPG sensors, or two Bioimpedance (BioZ) sensors. Our study addresses the mathematical inaccuracies of previous bioimpedance approaches and incorporates PTT weights for the peak-peak (PTTpp), middle-middle (PTTmm), and foot-foot (PTTff) segments of the sensing signal into a single neuron model to determine a more accurate and stable PWV. In addition, we developed a tetherless bioimpedance device and compared our PTT estimation approaches, which yielded PWV across six subjects and two different arteries. Specifically, using our model, we found that the most reliable combination of weights corresponding to PTTpp, PTTmm, and PTTff was (0.260, 0.704, 0.036) for the brachial artery and (0.104, 0.858, 0.038) for radial artery. This model consistently yielded stable values across repetitions, with PWV values of 5.2 m/s, 5.3 m/s, and 5.9 m/s for the brachial artery and values of 5.8 m/s, 6.6 m/s, and 6.5 m/s for the radial artery. This system and model offer the possibility of obtaining higher reliability PTT and PWV values yielding better monitoring of cardiovascular health measures such as blood pressure and arterial stiffness.

2.
Vaccine ; 42(26): 126292, 2024 Sep 07.
Article in English | MEDLINE | ID: mdl-39245584

ABSTRACT

Rapid and early identification of emergent infections is essential for delivering prompt clinical care. To advance the development of algorithms for the clinical management of infection identification, we performed a vaccination clinical trial to investigate the potential of using vaccination as a model for studying mild inflammation responses associated with different infections (NCT05346302). We collected data at various time points over 4 weeks from blood samples, wearable devices, and questionnaires. Following a 2-week baseline period, 210 healthy participants, aged 18-40 years, were administered either a Pneumococcal Polysaccharide vaccine (PPSV23), Typhoid Vi Polysaccharide vaccine (Typhim Vi), or placebo. In longitudinal analyses of blood biomarkers, we found that CRP was significantly higher at 2 days post-vaccination, whereas basophils, IL-10, IL-12p40, and MIG were significantly higher at 7 days post-vaccination in the PPSV23 group compared to both other groups (all p < 0.05). MIP-1ß was significantly lower in the PPSV23 group than in the placebo group, while monocytes and MPV were significantly lower in the Typhim Vi group than in the placebo group at 7 days post-vaccination (all p < 0.05). The PPSV3 group showed a higher inflammatory profile, suggesting that PPSV23 induces a stronger immune response compared to Typhim Vi. The distinct immune responses induced by the two vaccines indicate the potential for utilizing vaccines as models for studying inflammation responses associated with different infectious pathogens.

3.
Proc Natl Acad Sci U S A ; 121(37): e2403256121, 2024 Sep 10.
Article in English | MEDLINE | ID: mdl-39186667

ABSTRACT

This study reports the earliest directly dated occurrence of archaeological wheat and cotton in the humid forests of West Africa. These are the first archaeobotanical results from the medieval urban center of Ile-Ife, southwestern Nigeria, best known for its famous artworks. Both wheat and cotton likely spread through trans-Saharan trade networks that laid the foundation for later European trade systems. Forty-eight (48) grains of free-threshing wheat (Triticum aestivum/durum) represent the largest assemblage of wheat recovered in sub-Saharan West Africa, which is surprising given that wheat cannot be cultivated locally. Larger quantities of cotton (Gossypium sp.) recovered from late 12th- to early 13th-century CE contexts suggest earlier and more widespread use than wheat. Cotton may have been cultivated and manufactured into cloth locally. The quick adoption of these exotic crops illustrates the active negotiation of prestige through culinary and adornment practices, as well as a high degree of agricultural experimentation.


Subject(s)
Archaeology , Gossypium , Triticum , Nigeria , History, Medieval , Agriculture/history , Crops, Agricultural/history , Humans
4.
IEEE Trans Biomed Eng ; PP2024 Aug 06.
Article in English | MEDLINE | ID: mdl-39106139

ABSTRACT

OBJECTIVE: Rapid advances in cuffless blood pressure (BP) monitoring over the last decade have the potential to radically transform clinical care for cardiovascular health. However, due to the large heterogeneity in device design and evaluation, it is difficult to critically and quantitatively evaluate research progress in cuffless BP monitoring. In this two-part manuscript, we seek to provide a principled way of describing and accounting for the heterogeneity in device and study design. METHODS: We first provide an overview of foundational elements and design principles of three critical aspects in the pipeline: 1) sensors and systems, 2) pre-processing and feature extraction, and 3) BP estimation algorithms. Then, we critically analyze the state-of-theart methods via a systematic review. RESULTS: We find a large amount of heterogeneity in study designs making fair comparisons challenging. In addition, many study designs lead to data leakage, and underpowered studies. We suggest a first opencontribution BP estimation benchmark based on existing public datasets for standardized algorithmic comparisons. Second, we observe that BP distribution in the study sample and the time between calibration and test in emerging personalized devices are significant confounders in BP estimation error. We suggest accounting for these using a metric "explained deviation" which is closely related to the coefficient of determination (R2, a frequently used statistic). Finally, we complement this manuscript with a website, https://wearablebp.github.io, containing a bibliography, meta-analysis results, datasets, and benchmarks, providing a timely platform to understand the state-of-the-art devices. CONCLUSION: There is large heterogeneity in device and study design, which should be carefully accounted for when designing, comparing, and contrasting studies. SIGNIFICANCE: Our findings will allow readers to parse out the heterogeneous literature and move toward promising directions for safer and more reliable devices in clinical practice and beyond.

5.
ACS Appl Bio Mater ; 7(5): 3005-3013, 2024 05 20.
Article in English | MEDLINE | ID: mdl-38629141

ABSTRACT

Freeze-based immobilization of deoxyribonucleic acid (DNA) oligonucleotides on gold nanoparticles (AuNPs) is highly efficient for single-stranded oligonucleotides but typically does not accommodate structures such as snap-cooled DNA hairpins (Sc-HPs) and snap-cooled molecular beacons (Sc-MBs) frequently used for biorecognition applications. Recognizing this limitation, we have developed a modified, freeze-based technique specifically designed to enable the adsorption of such hairpin oligonucleotides onto AuNP surfaces while ensuring that they retain their biosensing capabilities. Successful hairpin oligonucleotide conjugation of varying lengths to a wide range of AuNP diameters was corroborated by dynamic light scattering, ζ-potential, and UV-vis spectrophotometry. Moreover, we conducted a thorough evaluation of this modified method, confirming the retention of the sensing functions of Sc-HPs and Sc-MBs. This advancement not only offers a more efficient route for DNA hairpin conjugation but also elucidates the underlying biorecognition functions, with implications for broader applications in molecular diagnostics.


Subject(s)
Biosensing Techniques , DNA , Gold , Metal Nanoparticles , Gold/chemistry , Metal Nanoparticles/chemistry , DNA/chemistry , Materials Testing , Particle Size , Biocompatible Materials/chemistry , Biocompatible Materials/chemical synthesis
6.
Adv Mater Technol ; 8(15)2023 Aug 11.
Article in English | MEDLINE | ID: mdl-37701636

ABSTRACT

Continuous monitoring of arterial blood pressure is clinically important for the diagnosis and management of cardiovascular diseases. Soft electronic devices with skin-like properties show promise in a wide range of applications, including the human-machine interface, the Internet of things, and health monitoring. Here, we report the use of add-on soft electronic interfaces to address the connection challenges between soft electrodes and rigid data acquisition circuitry for bioimpedance monitoring of cardiac signals, including heart rate and cuffless blood pressure. Nanocomposite films in add-on electrodes provide robust electrical and mechanical contact with the skin and the rigid circuitry. We demonstrate bioimpedance sensors composed of add-on electrodes for continuous blood pressure monitoring with high accuracy. Specifically, the bioimpedance collected with add-on nanocomposite electrodes shows a signal-to-noise ratio of 37.0 dB, higher than the ratio of 25.9 dB obtained with standard silver/silver chloride (Ag/AgCl gel) electrodes. Although the sample set is low, the continuously measured systolic and diastolic blood pressure offer accuracy of -2.0 ± 6.3 mmHg and -4.3 ± 3.9 mmHg, respectively, confirming the grade A performance based on the IEEE standard. These results show promise in bioimpedance measurements with add-on soft electrodes for cuffless blood pressure monitoring.

7.
ACS Omega ; 7(47): 42801-42808, 2022 Nov 29.
Article in English | MEDLINE | ID: mdl-36467937

ABSTRACT

A thermal sensor was used to better understand parameters which influenced the interaction between a laser beam and a 0.5% Mn-doped ZnAl2.2O4 material, especially the laser defocusing parameter. The optical properties of the material depend on whether the Mn2+ ions occupy octahedral and/or tetrahedral sites depending on thermal history. A screen printing process is performed to obtain material thin films. Laser irradiation of the films was carried out (patterning 1 cm length single laser track) with different z defocusing heights. Luminescence properties around laser tracks led to the thermal history determination at the micrometer scale. It was shown that spatial thermal gradients defined at the micrometer scale perpendicularly to the borders of the laser tracks could be semiquantified for different z conditions. Laser defocusing leads to decrease thermal gradients as confirmed by thermal modeling studies.

8.
J Biomed Opt ; 27(11)2022 11.
Article in English | MEDLINE | ID: mdl-36401344

ABSTRACT

Significance: Insertable optical continuous glucose monitors (CGMs) with wearable readers are a strong option for monitoring individuals with diabetes. However, a fully insertable CGM requires a small form factor while still delivering sufficient signal to be read through tissue by an external device. Previous work has suggested that a multimodal repeating unit (barcode) approach may meet these requirements, but the biosensor geometry must be optimized to meet performance criteria. Aim: This work details in silico trials conducted to evaluate the geometry of a fully insertable multimodal optical biosensor with respect to both optical output and species diffusion in vivo. Approach: Monte Carlo modeling is used to evaluate the luminescent output of three presupposed biosensor designs based on size constraints for an injectable and logical placement of the bar code compartments. Specifically, the sensitivity of the luminescent output to displacement of the biosensor in the X and Y directions, overall size of the selected design, and size of an individual repeating unit are analyzed. Further, an experimentally validated multiphysics model is used to evaluate the diffusion and reaction of glucose and oxygen within the biosensor to estimate the occurrence of chemical crosstalk between the assay components. Results: A stacked cylinder multimodal biosensor 4.4 mm in length with repeating units 0.36 mm in length was found to yield a greater luminescent output than the current "barcode" biosensor design. In addition, it was found that a biosensor with enzymatic elements does not significantly deplete glucose locally and thus does not impact the diffusion profile of glucose in adjacent compartments containing nonenzymatic assays. Conclusions: Computational modeling was used to design the geometry of a multimodal, insertable, and optical CGM to ensure that the optical output and chemical diffusion profile are sufficient for this device to function in vivo.


Subject(s)
Biosensing Techniques , Diabetes Mellitus , Humans , Glucose , Blood Glucose , Luminescence
9.
J Diabetes Sci Technol ; : 19322968221116393, 2022 Aug 04.
Article in English | MEDLINE | ID: mdl-35927975

ABSTRACT

BACKGROUND: Monitoring glucose excursions is important in diabetes management. This can be achieved using continuous glucose monitors (CGMs). However, CGMs are expensive and invasive. Thus, alternative low-cost noninvasive wearable sensors capable of predicting glycemic excursions could be a game changer to manage diabetes. METHODS: In this article, we explore two noninvasive sensor modalities, electrocardiograms (ECGs) and accelerometers, collected on five healthy participants over two weeks, to predict both hypoglycemic and hyperglycemic excursions. We extract 29 features encompassing heart rate variability features from the ECG, and time- and frequency-domain features from the accelerometer. We evaluated two machine-learning approaches to predict glycemic excursions: a classification model and a regression model. RESULTS: The best model for both hypoglycemia and hyperglycemia detection was the regression model based on ECG and accelerometer data, yielding 76% sensitivity and specificity for hypoglycemia and 79% sensitivity and specificity for hyperglycemia. This had an improvement of 5% in sensitivity and specificity for both hypoglycemia and hyperglycemia when compared with using ECG data alone. CONCLUSIONS: Electrocardiogram is a promising alternative not only to detect hypoglycemia but also to predict hyperglycemia. Supplementing ECG data with contextual information from accelerometer data can improve glucose prediction.

10.
Biosensors (Basel) ; 12(8)2022 Aug 04.
Article in English | MEDLINE | ID: mdl-36004994

ABSTRACT

Cardiovascular disease is the leading cause of death globally. To provide continuous monitoring of blood pressure (BP), a parameter which has shown to improve health outcomes when monitored closely, many groups are trying to measure blood pressure via noninvasive photoplethysmography (PPG). However, the PPG waveform is subject to variation as a function of patient-specific and device factors and thus a platform to enable the evaluation of these factors on the PPG waveform and subsequent hemodynamic parameter prediction would enable device development. Here, we present a computational workflow that combines Monte Carlo modeling (MC), gaussian combination, and additive noise to create synthetic dataset of volar fingertip PPG waveforms representative of a diverse cohort. First, MC is used to determine PPG amplitude across age, skin tone, and device wavelength. Then, gaussian combination generates accurate PPG waveforms, and signal processing enables data filtration and feature extraction. We improve the limitations of current synthetic PPG frameworks by enabling inclusion of physiological and anatomical effects from body site, skin tone, and age. We then show how the datasets can be used to examine effects of device characteristics such as wavelength, analog to digital converter specifications, filtering method, and feature extraction. Lastly, we demonstrate the use of this framework to show the insensitivity of a support vector machine predictive algorithm compared to a neural network and bagged trees algorithm.


Subject(s)
Photoplethysmography , Signal Processing, Computer-Assisted , Computer Simulation , Hemodynamics , Humans , Photoplethysmography/methods , Workflow
11.
Anal Chem ; 94(31): 11008-11015, 2022 08 09.
Article in English | MEDLINE | ID: mdl-35912577

ABSTRACT

Chip-scale infrared spectrometers consisting of a microring resonator array (MRA) were developed for volatile organic compound (VOC) detection. The MRA is serially positioned to serve as a wavelength sorting element that enables wavelength demultiplexing. Unlike conventional devices operated by a single microring, our MRA can perform multiwavelength mid-infrared (mid-IR) sensing by routing the resonant wavelength light from a broadband mid-IR source into different sensing channels. Miniaturized spectrometer devices were fabricated on mid-IR transparent silicon-rich silicon nitride (SiNx) thin films through complementary metal-oxide-semiconductor (CMOS) processes, thus enabling wafer-level manufacturing and packaging. The spectral distribution of the resonance lines and the optimization of the microring structures were designed using finite-difference time-domain (FDTD) modeling and then verified by laser spectrum scanning. Using small microring structures, the spectrum showed a large free spectral range (FSR) of 100 nm and held four spectral channels without crosstalk. Unlike near-infrared microrings using refractive index sensing, our MRA can detect hexane and ethanol vapor pulses by monitoring the intensity variation at their characteristic mid-IR absorption bands, thus providing high specificity. Applying multiwavelength detection, the sensor module can discriminate among various VOC vapors. Hence, our mid-IR MRA could be an essential component to achieve a compact spectroscopic sensing module that has the potential for applications such as remote environmental monitoring and portable health care devices.


Subject(s)
Volatile Organic Compounds , Gases , Light , Refractometry/methods
12.
Cardiovasc Intervent Radiol ; 45(9): 1391-1398, 2022 09.
Article in English | MEDLINE | ID: mdl-35790566

ABSTRACT

STUDY PURPOSE: The DRAGON 1 trial aims to assess training, implementation, safety and feasibility of combined portal- and hepatic-vein embolization (PVE/HVE) to accelerate future liver remnant (FLR) hypertrophy in patients with borderline resectable colorectal cancer liver metastases. METHODS: The DRAGON 1 trial is a worldwide multicenter prospective single arm trial. The primary endpoint is a composite of the safety of PVE/HVE, 90-day mortality, and one year accrual monitoring of each participating center. Secondary endpoints include: feasibility of resection, the used PVE and HVE techniques, FLR-hypertrophy, liver function (subset of centers), overall survival, and disease-free survival. All complications after the PVE/HVE procedure are documented. Liver volumes will be measured at week 1 and if applicable at week 3 and 6 after PVE/HVE and follow-up visits will be held at 1, 3, 6, and 12 months after the resection. RESULTS: Not applicable. CONCLUSION: DRAGON 1 is a prospective trial to assess the safety and feasibility of PVE/HVE. Participating study centers will be trained, and procedures standardized using Work Instructions (WI) to prepare for the DRAGON 2 randomized controlled trial. Outcomes should reveal the accrual potential of centers, safety profile of combined PVE/HVE and the effect of FLR-hypertrophy induction by PVE/HVE in patients with CRLM and a small FLR. TRIAL REGISTRATION: Clinicaltrials.gov: NCT04272931 (February 17, 2020). Toestingonline.nl: NL71535.068.19 (September 20, 2019).


Subject(s)
Embolization, Therapeutic , Liver Neoplasms , Accreditation , Embolization, Therapeutic/methods , Hepatectomy/methods , Hepatic Veins/pathology , Hepatomegaly , Humans , Hypertrophy/etiology , Hypertrophy/pathology , Hypertrophy/surgery , Liver/surgery , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/pathology , Liver Neoplasms/therapy , Multicenter Studies as Topic , Portal Vein/pathology , Prospective Studies , Treatment Outcome
13.
J Biomed Opt ; 27(8)2022 05.
Article in English | MEDLINE | ID: mdl-35505461

ABSTRACT

SIGNIFICANCE: Continuous glucose monitors (CGMs) are increasingly utilized as a way to provide healthcare to the over 10% of Americans that have diabetes. Fully insertable and optically transduced biosensors are poised to further improve CGMs by extending the device lifetime and reducing cost. However, optical modeling of light propagation in tissue is necessary to ascertain device performance. AIM: Monte Carlo modeling of photon transport through tissue was used to assess the luminescent output of a fully insertable glucose biosensor that uses a multimodal Förster resonance energy transfer competitive binding assay and a phosphorescence lifetime decay enzymatic assay. APPROACH: A Monte Carlo simulation framework of biosensor luminescence and tissue autofluorescence was built using MCmatlab. Simulations were first validated against previous research and then applied to predict the response of a biosensor in development. RESULTS: Our results suggest that a diode within the safety standards for light illumination on the skin, with far-red excitation, allows the luminescent biosensor to yield emission strong enough to be detectable by a common photodiode. CONCLUSIONS: The computational model showed that the expected fluorescent power output of a near-infrared light actuated barcode was five orders of magnitude greater than a visible spectrum excited counterpart biosensor.


Subject(s)
Biosensing Techniques , Fluorescence Resonance Energy Transfer , Glucose , Humans , Monte Carlo Method , Photons
14.
PLoS One ; 17(4): e0266441, 2022.
Article in English | MEDLINE | ID: mdl-35390054

ABSTRACT

Malaria is often most endemic in remote regions where diagnostic microscopy services are unavailable. In such regions, the use of rapid diagnostic tests fails to quantify parasitemia measurements which reflect the concentration of Plasmodium parasites in the bloodstream. Thus, novel diagnostic and monitoring technologies capable of providing such information could improve the quality of treatment, monitoring, and eradication efforts. A low-cost, portable microscope for gathering quantitative parasitemia data from fluorescently stained thin blood smears is presented. The system employs bimodal imaging using components optimized for cost savings, system robustness, and optical performance. The microscope is novel for its use of monochromatic visible illumination paired with a long working distance singlet aspheric objective lens that can image both traditionally mounted and cartridge-based blood smears. Eight dilutions of red blood cells containing laboratory cultured wild-type P. falciparum were used to create thin smears which were stained with SYBR Green-1 fluorescent dye. Two subsequent images are captured for each field-of-view, with brightfield images providing cell counts and fluorescence images providing parasite localization data. Results indicate the successful resolution of sub-micron sized parasites, and parasitemia measurements from the prototype microscope display linear correlation with measurements from a benchtop microscope with a limit of detection of 0.18 parasites per 100 red blood cells.


Subject(s)
Malaria/diagnosis , Erythrocytes/parasitology , Fluorescent Dyes , Humans , Malaria/blood , Malaria/parasitology , Malaria, Falciparum/diagnosis , Malaria, Falciparum/parasitology , Microscopy, Fluorescence , Parasitemia/blood , Parasitemia/diagnosis , Parasitemia/parasitology , Plasmodium falciparum/isolation & purification
15.
Sci Rep ; 12(1): 5572, 2022 04 02.
Article in English | MEDLINE | ID: mdl-35368033

ABSTRACT

Mid-infrared (mid-IR) sensors consisting of silicon nitride (SiN) waveguides were designed and tested to detect volatile organic compounds (VOCs). SiN thin films, prepared by low-pressure chemical vapor deposition (LPCVD), have a broad mid-IR transparent region and a lower refractive index (nSiN = 2.0) than conventional materials such as Si (nSi = 3.4), which leads to a stronger evanescent wave and therefore higher sensitivity, as confirmed by a finite-difference eigenmode (FDE) calculation. Further, in-situ monitoring of three VOCs (acetone, ethanol, and isoprene) was experimentally demonstrated through characteristic absorption measurements at wavelengths λ = 3.0-3.6 µm. The SiN waveguide showed a five-fold sensitivity improvement over the Si waveguide due to its stronger evanescent field. To our knowledge, this is the first time SiN waveguides are used to perform on-chip mid-IR spectral measurements for VOC detection. Thus, the developed waveguide sensor has the potential to be used as a compact device module capable of monitoring multiple gaseous analytes for health, agricultural and environmental applications.


Subject(s)
Volatile Organic Compounds , Acetone , Silicon Compounds
16.
J Biomed Opt ; 27(3)2022 03.
Article in English | MEDLINE | ID: mdl-35352513

ABSTRACT

SIGNIFICANCE: Obesity is a worldwide epidemic contributing directly to several cardiovascular risk factors including hypertension and type 2 diabetes. Wearable devices are becoming better at quantifying biomarkers relevant for the management of health and fitness. Unfortunately, both anecdotal evidence and recent studies indicate that some wearables have higher levels of error when utilized by populations with darker skin tones and high body mass index (BMI). There is an urgent need for a better evaluation of the limits of wearable health technologies when used by obese individuals. AIMS: (1) To review the current know-how on changes due to obesity in the skin epidermis, dermis, and subcutis that could affect the skin optical properties; (2) for the green wavelength range, to evaluate the difference in absorption and scattering coefficients from the abdominal skin between individuals with and without elevated BMI. The changes include alterations in layer thickness and cell size, as well as significant differences in chromophores and scatterer content, e.g., water, hemoglobin, collagen, and lipids. APPROACH: We have summarized literature pertaining to changes in skin and its components in obesity and report the results of our search using articles published between years 1971 and 2020. A linear model was used to demonstrate the absorption and reduced scattering coefficient of the abdominal skin of individuals with and without elevated BMI in the green wavelength range (530 to 550 nm) that is typically found in most wearables. RESULTS: The general trends indicate a decrease in absorption for both dermis and subcutis and an increase in reduced scattering for both epidermis and dermis. At 544-nm wavelength, a typical wavelength used for photoplethysmography (PPG), the absorption coefficient's relative percentage difference between high and low BMI skin, was 49% in the subcutis, 19% in the dermis, and negligible in the epidermis, whereas the reduced scattering coefficient relative difference was 21%, 29%, and 165% respectively. CONCLUSIONS: These findings suggest that there could be significant errors in the output of optical devices used for monitoring health and fitness if changes due to obesity are not accounted for in their design.


Subject(s)
Diabetes Mellitus, Type 2 , Body Mass Index , Epidermis , Humans , Obesity/diagnostic imaging , Skin/blood supply , Skin/diagnostic imaging
17.
Anal Chim Acta ; 1198: 339562, 2022 Mar 15.
Article in English | MEDLINE | ID: mdl-35190126

ABSTRACT

Multiplexed assays are essential for the detection of biomarker panels. Differentiating signals from different biomarkers in a single test zone makes the detection more efficient. In this paper, a new method is designed for the synthesis of gap-enhanced nanoparticles (GeNPs) using Raman reporter molecules (RRM) and 6-amino-1-hexanethiol (6-AHT) as the spacer. The GeNPs show a nanometer-size gap, generate strong surface-enhanced Raman scattering (SERS) attributed to the gap, and exhibit discriminative spectral peaks. The strong Au-S bonds on both core and shell sides and the covalent bond between RRM and 6-AHT led to a stable structure, which ensured the stable SERS signal generation from the GeNPs. Using the GeNPs, a spectrally multiplexed assay for the detection of a biomarker panel is developed. The biomarker panel is composed of cardiac troponin I (cTnI), copeptin, and heart-type fatty acid-binding protein (h-FABP), which improves myocardial infarction (MI) diagnostic performance. A paper-based platform that is more amenable to point-of-care diagnostic analysis is used. The developed single biomarker assay achieves limits of detection of 0.01 ng mL-1, 0.86 ng mL-1, 0.004 ng mL-1 for cTnI, h-FABP, and copeptin in buffer solutions. The dynamic range of the assay in human serum samples also covers the clinically relevant range of the biomarkers. The cross interference in the multiplexed assay is low. These results show the strong potential of the developed GeNPs in multiplexed detection of biomarkers and the developed simple-to-use multiplexed assay in the diagnosis of MI at the point of care.


Subject(s)
Metal Nanoparticles , Myocardial Infarction , Biomarkers/analysis , Humans , Metal Nanoparticles/chemistry , Myocardial Infarction/diagnosis , Spectrum Analysis, Raman/methods , Troponin I
18.
Zootaxa ; 5219(3): 265-275, 2022 Dec 09.
Article in English | MEDLINE | ID: mdl-37044864

ABSTRACT

Colobothea batesi sp. nov. is described based on specimens from Peru, French Guiana, and Brazil. Photographs of the male holotype and one female paratype are provided, as well as photographs of a male and a female of C. hirtipes (Degeer, 1775) to facilitate comparison. Notes on host plants of C. hirtipes are also provided.


Subject(s)
Coleoptera , Animals , Brazil , French Guiana , Peru
19.
J Environ Manage ; 302(Pt A): 113960, 2022 Jan 15.
Article in English | MEDLINE | ID: mdl-34700076

ABSTRACT

The rapid specialization of livestock production in China has contributed to spatially decoupled crop and livestock production, leading to various environmental pollution issues. Some regional agro-environmental policies have recently promoted the coupling of specialized crop and livestock farms through cooperation. However, the environmental and economic performances of such cooperation remain unclear. This study investigated multiple environmental footprints of two contrasting production systems: cooperative crop-livestock systems (CCLS) and decoupled specialized livestock systems (DSLS), using survey data of 87 ruminant farms in Northwest China. Results show that farms in CCLS had lower net greenhouse gas (GHG) emissions (12-29%), lower reactive nitrogen (Nr) emissions (21-40%), lower phosphorus footprints (PF) (41-54%), and used less cropland (24-31%) per kg animal product, compared to those in DSLS. The large differences in GHG emissions between the two systems were mainly related to enteric fermentation and resource production (used for feed production). The differences in Nr emissions and PF were mainly related to manure management. Net profits per kg animal product were higher in CCLS (13-35%) than in DSLS, and most profits originated from lower purchasing costs of feed and young livestock. Net profits and environmental footprints were negatively correlated, suggesting an environmental and economic win-win situation for CCLS. The possible obstacles to recoupling specialized crop and livestock farms through cooperation have been discussed, including farm size, contract stability, and local policies. Our study provides science-based evidence to support policymakers and specialized farms to close nutrient loops between crop and livestock production sectors through regional cooperation.


Subject(s)
Greenhouse Gases , Livestock , Animals , Farms , Manure , Nitrogen
20.
IEEE J Biomed Health Inform ; 26(6): 2726-2736, 2022 06.
Article in English | MEDLINE | ID: mdl-34882568

ABSTRACT

Diet monitoring is an essential intervention component for a number of diseases, from type 2 diabetes to cardiovascular diseases. However, current methods for diet monitoring are burdensome and often inaccurate. In prior work, we showed that continuous glucose monitors (CGMs) may be used to predict meal macronutrients (e.g., carbohydrates, protein, fat) by analyzing the shape of the post-prandial glucose response. In this study, we examine a number of additional dietary biomarkers in blood by their ability to improve macronutrient prediction, compared to using CGMs alone. For this purpose, we conducted a nutritional study where (n = 10) participants consumed nine different mixed meals with varied but known macronutrient amounts, and we analyzed the concentration of 33 dietary biomarkers (including amino acids, insulin, triglycerides, and glucose) at various times post-prandially. Then, we built machine learning models to predict macronutrient amounts from (1) individual biomarkers and (2) their combinations. We find that the additional blood biomarkers provide complementary information, and more importantly, achieve lower normalized root mean squared error (NRMSE) for the three macronutrients (carbohydrates: 22.9%; protein: 23.4%; fat: 32.3%) than CGMs alone (carbohydrates: 28.9%, t(18) =1.64, p =0.060; protein: 46.4%, t(18) =5.38, p 0.001; fat: 40.0%, t(18) =2.09, p =0.025). Our main conclusion is that augmenting CGMs to measure these additional dietary biomarkers improves macronutrient prediction performance, and may ultimately lead to the development of automated methods to monitor nutritional intake. This work is significant to biomedical research as it provides a potential solution to the long-standing problem of diet monitoring, facilitating new interventions for a number of diseases.


Subject(s)
Diabetes Mellitus, Type 2 , Dietary Carbohydrates , Biomarkers , Blood Glucose/metabolism , Diet , Dietary Fats/metabolism , Dietary Proteins/metabolism , Glucose , Humans , Insulin , Meals/physiology , Nutrients
SELECTION OF CITATIONS
SEARCH DETAIL