Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Rev. esp. patol ; 53(4): 218-225, oct.-dic. 2020. ilus, tab
Article in Spanish | IBECS | ID: ibc-200567

ABSTRACT

INTRODUCCIÓN Y OBJETIVOS: Con frecuencia los urólogos remiten el tejido resecado durante las vasectomías para estudio anatomopatológico con el fin de confirmar la presencia de conducto deferente. El estudio microscópico es sencillo y se suele hacer con hematoxilina-eosina. En ocasiones, se ve dificultado por artefactos de la muestra y la inmunohistoquímica puede ayudar a reconocer la presencia de deferente. MATERIALES Y MÉTODOS: Hemos investigado la utilidad de la determinación inmunohistoquímica de cadherina E y GATA-3 para confirmar epitelio del deferente en 110 secciones de vasectomías con diferentes artefactos, utilizando anticuerpos monoclonales y técnica de multímero conjugado con peroxidasa; 5 arterias y 5 venas renales fueron controles negativos. RESULTADOS: Con cadherina E se observó tinción de membrana moderada (2,7%) o intensa (97,3%) en el epitelio del deferente en todos los casos: 35 sin artefacto, 7 con epitelio denudado, 56 con epitelio comprimido o distorsionado, 8 con epitelio desprendido y 4 con epitelio desplazado. GATA-3 mostró positividad nuclear moderada (31%) o intensa (69%) en todos los casos, incluyendo los 76 con los artefactos señalados. Las arterias y venas fueron negativas para ambos marcadores en el endotelio, con positividad para GATA-3 en ocasionales linfocitos de la pared. CONCLUSIONES: La inmunohistoquímica puede ayudar a reconocer la presencia de epitelio del deferente en vasectomías artefactadas con positividad de membrana para cadherina E y expresión nuclear de GATA-3. El endotelio vascular, por el contrario, es negativo para ambos marcadores. No se debe malinterpretar como positividad la posible tinción para GATA-3 de linfocitos de la pared


INTRODUCTION AND OBJECTIVES: Urologists often submit the resected tissue from vasectomies for histopathological examination in order to confirm the presence of the vas deferens. Microscopy is simple and based on haematoxylin-eosin staining; however, sample artefacts can sometimes cause confusion and immunohistochemistry can be used to identify the vas deferens. MATERIALS AND METHODS: We investigated the utility of immunohistochemical analysis using E-cadherin and GATA-3 to confirm the presence of vas deferens epithelium in 110 vasectomy sections with different artefacts, using monoclonal antibodies and a multimer conjugated with peroxidase based technique; 5 renal arteries and 5 renal veins were stained as negative controls. RESULTS: Membrane staining was observed for E-cadherin, which was moderate (2.7%) or strong (97.3%) in the vas deferens epithelium in all cases: 35 without artefacts, 7 with denuded epithelium, 56 with compressed/distorted epithelium, 8 with detached epithelium and 4 with displaced epithelium. GATA-3 showed moderate (31%) or strong (69%) nuclear staining in all cases, including the 76 with artefacts. In the control group, arteries and veins were negative for both markers in the endothelium, but GATA-3 occasionally stained lymphocytes in the blood vessel wall. CONCLUSIONS: E-cadherin membrane positivity and GATA-3 nuclear expression are useful for the identification of the vas deferens in vasectomy samples containing artefacts. Vascular endothelium is negative for both markers and any possible GATA-3 staining of the lymphocytes in the blood vessel wall should not be misinterpreted


Subject(s)
Humans , Male , Cadherins/isolation & purification , GATA3 Transcription Factor/isolation & purification , Vasectomy/classification , Vas Deferens/cytology , Immunohistochemistry/methods , Antibodies, Monoclonal , Endothelium, Vascular/pathology
2.
Arch. esp. urol. (Ed. impr.) ; 73(6): 534-540, jul.-ago. 2020. ilus
Article in Spanish | IBECS | ID: ibc-195928

ABSTRACT

OBJETIVOS: El estudio anatomopatológico de las muestras de vasectomía para confirmar la presencia de conducto deferente generalmente es sencillo se realiza con tinción rutinaria de hematoxilina-eosina. En aquellos casos con artefacto del epitelio, el uso de técnicas de inmunohistoquímica puede ayudar al diagnóstico y sirve, además para diferenciar deferente de vaso sanguíneo. Hemos investigado la utilidad de CD31, CD34, ERG y PAX8 para estos fines. MATERIAL Y MÉTODOS: Se han estudiado 81 secciones de muestras de vasectomía en las que alguna sección presentaba algún tipo de artefacto en el epitelio. Se realizó inmunohistoquímica con anticuerpos monoclonales para CD31 (clon JC70), CD34 (clon QBEnd/10), ERG (clon EPR3864) y PAX8 (clon MRQ-50) evaluando la tinción en el epitelio deferencial y en el endotelio vascular. RESULTADOS: Histológicamente, el epitelio del conducto deferente aparecía conservado en 18 secciones (22,2%), denudado en 6 (7,4%), con artefacto de compresión o distorsión en 48 secciones (59,3%), desprendidoen 5 (6,2%) y desplazado fuera de la luz del conducto en 4 (4,9%). En la mayoría de las secciones el epitelio del CD presentó positividad citoplasmática para CD31, que fue débil (86,4%) o moderada (9,9%), y expresó intensamente PAX8 en los núcleos, con tinción granular en el epitelio denudado o artefactado. Fueron negativos CD34 y ERG. El endotelio capilar de los vasos de la pared del conducto deferente mostró intensa positividad citoplasmática para CD31 y CD34, y nuclear para ERG, siendo PAX8 negativo. CONCLUSIONES: PAX8 es un anticuerpo útil para confirmar la presencia de conducto deferente en muestras de vasectomía con artefacto. Son negativos CD34 yERG, que, por el contrario, marcan endotelio vascular, presentando ERG la ventaja de que la tinción es nuclear.CD31, marcador endotelial clásico, no es tan específico como se había propuesto puesto que presenta expresión débil en el epitelio del deferente


OBJECTIVES: The pathological examination of vasectomy specimens to confirm the presence of vas deferens is usually simple and is done by routine hematoxylin and eosin staining. Use of immunohistochemical techniques can aid to the diagnosis in those cases with artifacts of the epithelium, and they are also useful to differentiate vas deferens from blood vessel. We have investigated the usefulness of CD31, CD34, ERG and PAX8 for these purposes. MATERIAL AND METHODS: 81 sections from vasectomy specimens in which any section showed some kind of epithelial artifact were analyzed. Immunohistochemistry was performed with monoclonal antibodies for CD31 (clone JC70), CD34 (clone QBEnd/10), ERG (clone EPR3864) and PAX8 (clone MRQ-50). Evaluation of the vas deferens and vascular endothelial staining was done. RESULTS: Histologically, vas deferens epithelium was well-preserved in 18 sections (22.2%), denuded in 6 (7.4%), crushed or distorted in 48 sections (59.3%), detached in 5 (6,2%), and misplaced out of the vas deferens lumen in 4 (4.9%). In most of the sections the epithelium showed weak (86.4%) or moderate (9.9%) CD31 cytoplasmic staining, as well as strong nuclear PAX8 reactivity in all of the sections, exhibiting a granular pattern in the detached or artifacted epithelium. CD34 and ERG were negative in the epithelium. Capillary vessel endothelium in the vas deferens wall showed strong cytoplasmic positivity for CD31 and CD34, as well as nuclear ERG reactivity, being PAX8 negative. CONCLUSIONS: PAX8 is a useful antibody to confirm the presence of vas deferens in artifacted vasectomy specimens. CD34 and ERG are negative in the epithelium, and, otherwise, they are expressed by vascular endothelium, with the advantage of nuclear staining pattern for ERG. CD31, a classic endothelial marker, is not so specific as it had been stated as it shows weak or moderate expression in the vas deferens epithelium


Subject(s)
Humans , Male , Vas Deferens/chemistry , Vasectomy/methods , Platelet Endothelial Cell Adhesion Molecule-1/analysis , Antigens, CD34/analysis , Antibodies, Bispecific/analysis , PAX8 Transcription Factor/analysis , Vas Deferens/surgery , Immunohistochemistry , Biomarkers/analysis , Sensitivity and Specificity , Reference Values , Reproducibility of Results
3.
Arch. esp. urol. (Ed. impr.) ; 71(10): 832-839, dic. 2018. ilus
Article in Spanish | IBECS | ID: ibc-178764

ABSTRACT

OBJETIVOS: La tecnología de matrices tisulares (MTs) se ha implantado como método de trabajo habitual en la investigación de marcadores tisulares relacionados con el cáncer. Su inconveniente es la necesidad de contar con un dispositivo especial de precio elevado. Presentamos dos métodos manuales, económicos, que han sido válidos para construir MTs de pequeño y mediano formato. MATERIAL Y MÉTODOS: Se han elaborado 16 MTs de forma manual a partir de bloques convencionales de parafina, mediante dos técnicas diferentes. En la primera se utilizó una aguja Tru-Cut 16G a la que se cortó el bisel, para realizar los orificios en los bloques donantes (80 casos) y en los receptores (resultando dos MTs de 55 casos y dos de 25 casos). Para la segunda técnica se utilizó un dispositivo "punch" para biopsias cutáneas, de 4 mm de diámetro, que se aplicó a los bloques donantes (obteniendo 210 cilindros de 108 bloques) y a los receptores (12 MTs). En las secciones de las MTs obtenidas se realizaron tinciones de hematoxilina-eosina, inmunohistoquímica (IHQ) e hibridación in situ. RESULTADOS: La tasa de pérdida de material en las secciones obtenidas con el primer método fue del 26,5%, pero al haberse incluído dos cilindros de cada caso, al menos uno de ellos se conservó. En las MTs obtenidas con el método de punch biopsia no hubo pérdidas de tejido. Los resultados de todas las tinciones realizadas fueron óptimos. CONCLUSIONES: Estos dos métodos manuales de elaboración de MTs resultan relativamente sencillos y son económicos. La tasa de pérdida de tejido es sólo significativa en el primero de los métodos pero se puede compensar incluyendo varios cilindros de cada bloque donante. En el segundo método no han existido problemas destacables en la fase de microtomía


OBJECTIVES: Tissue array (TA) technology is widely used as a method for the in situ investigation of tissue markers in cancer studies. A limitation of this technique is the high price of tissue arrayers. We describe two easy and non-expensive manual methods, that haveproduced small and medium format arrays. MATERIAL AND METHODS: 16 TAs were manually constructed from conventional paraffin blocks using two different techniques. For the first method, a 16G Tru-Cut needle whose bevel edge had been cut, was used to make the holes in the donor blocks (80 cases) and the receptor ones (resulting in 2 TAs each one with 55 cases and two with 25 cases). In the second technique, a 4 mm-diameter punch for cutaneous biopsies was applied to the donor blocks (obtaining 210 cylinders from 108 blocks) and to the receptor ones (12 TAs). Hematoxylin-eosin, immunohistochemical and in situ hybridization stains were performed on sections from these TAs. RESULTS: The tissue loss rate in the sections obtained from the TAs constructed with the first method was 26.5%, but as two cylinders were included from each case, at least one of them was retained. There was not any loss of tissue in the sections from the TAs constructed with the second method. The results of all of the stains performed were successful. CONCLUSIONS: These two manual methods of elaboration of TAs result rather simple and they are economical. The tissue loss rate is significant in the first method but it can be compensated embedding more than one cylinder from each donor block. There was not any problem in the sectioning of the TAs constructed with the second method


Subject(s)
Tissue Array Analysis , In Situ Hybridization , Tissue Array Analysis/methods , Immunohistochemistry , Biomarkers
SELECTION OF CITATIONS
SEARCH DETAIL