Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 56
Filter
1.
Front Immunol ; 15: 1447980, 2024.
Article in English | MEDLINE | ID: mdl-39295866

ABSTRACT

The ubiquitous Torque teno virus (TTV) establishes a chronically persistent infection in the human host. TTV has not been associated with any apparent disease, but, as part of the human virome, it may confer a regulatory imprint on the human immune system with as yet unclear consequences. However, so far, only few studies have characterized the TTV-specific immune responses or the overall immunological imprints by TTV. Here, we reveal that TTV infection leads to a highly exhausted TTV-specific CD8+ T-cell response, hallmarked by decreased IFN-γ production and the expression of the inhibitory NKG2A-receptor. On a functional level, we identified a panel of highly polymorphic TTV-encoded peptides that lead to an expansion of regulatory NKG2A+ natural killer, NKG2A+CD4+, and NKG2A+CD8+ T cells via the stabilization of the non-classical HLA-E molecule. Our results thus demonstrate that TTV leads to a distinct imprint on the human immune system that may further regulate overall human immune responses in infectious, autoimmune, and malignant diseases.


Subject(s)
CD8-Positive T-Lymphocytes , DNA Virus Infections , HLA-E Antigens , Histocompatibility Antigens Class I , NK Cell Lectin-Like Receptor Subfamily C , Torque teno virus , Humans , Torque teno virus/immunology , NK Cell Lectin-Like Receptor Subfamily C/metabolism , NK Cell Lectin-Like Receptor Subfamily C/immunology , CD8-Positive T-Lymphocytes/immunology , Histocompatibility Antigens Class I/immunology , Histocompatibility Antigens Class I/metabolism , DNA Virus Infections/immunology , Interferon-gamma/metabolism , Interferon-gamma/immunology , Killer Cells, Natural/immunology , Killer Cells, Natural/metabolism , Male
2.
mBio ; : e0181224, 2024 Sep 24.
Article in English | MEDLINE | ID: mdl-39315800

ABSTRACT

Cell entry is a crucial step for a virus to infect a host cell. Human cytomegalovirus utilizes glycoprotein B (gB) to fuse the viral and host cell membranes upon receptor binding of gH/gL-containing complexes. Fusion is mediated by major conformational changes of gB from a metastable pre-fusion to a stable post-fusion state whereby the central trimeric coiled-coils, formed by domain (Dom)III α helices, remain structurally nearly unchanged. To better understand the role of the stable core, we individually introduced three potentially helix-breaking or one disulfide bond-breaking mutation in the DIII α3 to study different aspects of the viral behavior upon long-term culturing. Two of the three helix-breaking mutations, gB_Y494P and gB_I495P, were lethal for the virus in either fibroblasts or epithelial cells. The third substitution, gB_G493P, on the other hand, displayed a delayed replication and spread, which was more pronounced in epithelial cells, hinting at an impaired fusion. Interestingly, the disulfide bond-breaker mutation, gB_C507S, performed strikingly differently in the two cell types - lethal in epithelial cells and an atypical phenotype in fibroblasts, respectively. Replication curve analyses paired with the infection efficiency, the spread morphology, and the cell-cell fusogenicity suggest a dysregulated fusion process, which could be reverted by second-site mutations mapping predominantly to gB DomV. Our findings underline the functional importance of a stable DomIII core for a well-regulated DomV rearrangement during fusion.IMPORTANCEHuman cytomegalovirus (HCMV) can establish a lifelong infection. In most people, the infection follows an asymptomatic course; however, it is a major cause of morbidity and mortality in immunocompromised patients or neonates. HCMV has a very broad cell tropism, ranging from fibroblasts to epi- and endothelial cells. The virus uses different entry pathways utilizing the core fusion machinery consisting of glycoprotein complexes gH/gL and glycoprotein B (gB). The fusion protein gB undergoes fundamental rearrangements from a metastable pre-fusion to a stable post-fusion conformation. Here, we characterized the viral behavior after the introduction of four single-point mutations in the gB central core. These led to various cell type-specific atypical phenotypes and the emergence of compensatory mutations, demonstrating an important interaction between domains III and V. We provide a new basis for the development of a structurally and functionally altered gB, which can further serve as a tool for drug and vaccine development.

3.
Kidney Int Rep ; 9(6): 1730-1741, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38899213

ABSTRACT

Introduction: Earlier reports suggest that patients after ABO-incompatible kidney transplantation (ABOi) are at enhanced risk of developing BK-virus (BKV, also known as BK polyomavirus [BKPyV]) nephropathy (BKPyVAN). It remains elusive whether this is a result of more intense immunosuppression or an ABOi-associated "intrinsic attribute." To address this question, we measured Torque Teno virus (TTV) loads as a quantitative proxy for immunosuppressive depth in ABOi recipients and compared them to human leukocyte antigen-incompatible (HLAi, i.e. pretransplant donor-specific antibody-positive) and standard-risk transplant recipients. Methods: Our retrospective study screened 2256 consecutive kidney transplantations performed between 2007 and 2020 at the Medical University of Vienna. Out of 629 in-principle eligible transplantations, we were able to include 465 patients: 42 ABOi, 106 HLAi, and 317 control recipients. Longitudinal TTV- polymerase chain reaction (PCR) and BKV-PCR was carried out at predefined timepoints and ranged from pretransplant until month 24 posttransplantation. TTV loads and immunosuppression were evaluated in the context of BKV-associated complications. Results: ABOi recipients had a higher TTV load compared to HLAi and controls both at month 3 (median 1.5 × 109 vs. 2.4 × 108 vs. 9.1 × 107; P = 0.010) and at month 6 (3.1 × 109 vs. 1.4 × 107 vs. 6.4 × 107; P = 0.014) posttransplantation. Tacrolimus exposure was significantly higher in ABOi patients compared to HLAi and control patients (ABOi vs. HLAi: P = 0.007; ABOi vs. controls: P < 0.0001). Biopsy-proven BKPyVAN was more frequent in ABOi recipients when compared to HLAi and control recipients (11.9% vs. 2.8% vs. 4.1%; P = 0.046). Conclusion: Our data support the assumption that ABOi patients are indeed at higher risk to develop BKPyVAN. A higher TTV load and immunosuppressive burden suggest that intense immunosuppression, rather than an "intrinsic attribute" conferred by ABOi, may contribute to this finding.

4.
Wien Klin Wochenschr ; 136(15-16): 429-438, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38653873

ABSTRACT

BACKGROUND: External quality assessment (EQA) schemes provide objective feedback to participating laboratories about the performance of their analytical systems and information about overall regional analytical performance. The EQAs are particularly important during pandemics as they also assess the reliability of individual test results and show opportunities to improve test strategies. With the end of the COVID-19 pandemic, the testing frequency significantly decreased in Austria. Here, we analyzed whether this decrease had an effect on participation and/or performance in SARS-CoV­2 virus detection EQAs, as compared to the pandemic era. MATERIAL AND METHODS: Identical samples were sent to all participating laboratories, and the EQA provider evaluated the agreement of the reported results with defined targets. The EQA was operated under two schemes with identical samples and therefore we analyzed it as a single EQA round. The performance of testing was reported as true positive ratios, comparing the post-pandemic data to previous rounds. Furthermore, subgroups of participants were analyzed stratified by laboratory type (medical or nonmedical) and the test system format (fully automated or requiring manual steps). RESULTS: While the frequency of false negative results per sample did not change during the 3 years of the pandemic (5.7%, 95% confidence interval [CI] 3.1-8.4%), an average per sample false negative ratio of 4.3% was observed in the first post-pandemic EQA (0%, 1.8%, and 11% for the 3 positive samples included in the test panel, n = 109 test results per sample). In this first post-pandemic EQA medical laboratories (average 0.4% false negative across 3 samples, n = 90) and automated test systems (average 1.2% false negative, n = 261) had lower false negative ratios than nonmedical laboratories (22.8%, n = 19) and manual test systems (16.7%, n = 22). These lower average ratios were due to a low concentration sample, where nonmedical laboratories reported 36.8% and manual test systems 54.5% true positive results. CONCLUSION: Overall ratios of true positive results were below the mean of all results during the pandemic but were similar to the first round of the pandemic. A lower post-pandemic true positive ratio was associated with specific laboratory types and assay formats, particularly for samples with low concentration. The EQAs will continue to monitor the laboratory performance to ensure the same quality of epidemiological data after the pandemic, even if vigilance has decreased.


Subject(s)
COVID-19 , Pandemics , Quality Assurance, Health Care , SARS-CoV-2 , Austria/epidemiology , Humans , COVID-19/epidemiology , SARS-CoV-2/genetics , Reproducibility of Results , Laboratories, Clinical , COVID-19 Nucleic Acid Testing/standards
5.
J Med Virol ; 96(3): e29554, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38511586

ABSTRACT

Torque Teno virus (TTV) is nonpathogenic, highly prevalent, and reflects the immune status of its host. Thus, TTV plasma load was suggested for the guidance of immunosuppression post solid organ transplantation. The present study was designed to determine the kinetics of TTV following changes in calcineurin inhibitor (CNI) dose. A total of 48 adult recipients of a kidney graft transplanted at the Medical University of Vienna between 2018 and 2019 with isolated changes in CNI dose were selected from the prospective TTV-POET trial. TTV plasma load was quantified by in-house PCR. At Day 30 following CNI dose adaptation (median 33% of daily dose) no changes in TTV load were noted. However, at Day 60, following CNI dose reduction a lower TTV load of 6.4 log10 c/mL (median; interquartile range [IQR] 4.9-8.1) compared with the baseline of 7.1 log10 c/mL (IQR 5.3-8.9) was noted (p = 0.001); there was also a trend toward a higher TTV load following CNI increase (6.6 log10 c/mL, IQR 4.1-9.7 vs. 5.2 log10 c/mL, IQR 4.5-6.8; p = 0.09). The data suggested that TTV load changes become noticeable only 2 months after CNI dose adaptation, which might be the ideal time point for TTV load monitoring.


Subject(s)
DNA Virus Infections , Kidney Transplantation , Torque teno virus , Humans , Adult , Calcineurin Inhibitors , Torque teno virus/genetics , Prospective Studies , Immunosuppression Therapy , Transplant Recipients , Viral Load , DNA, Viral
6.
Lancet Microbe ; 4(12): e1015-e1023, 2023 12.
Article in English | MEDLINE | ID: mdl-37979591

ABSTRACT

BACKGROUND: The aim of external quality assessment (EQA) schemes is to evaluate the analytical performance of laboratories and test systems in a near-to-real-life setting. This monitoring service provides feedback to participant laboratories and serves as a control measure for the epidemiological assessment of the regional incidence of a pathogen, particularly during epidemics. Using data from EQA schemes implemented as a result of the intensive effort to monitor SARS-CoV-2 infections in Austria, we aimed to identify factors that explained the variation in laboratory performance for SARS-CoV-2 detection over the course of the COVID-19 pandemic. METHODS: For this observational study, we retrospectively analysed 6308 reverse transcriptase quantitative PCR (RT-qPCR) test results reported by 191 laboratories on 71 samples during 14 rounds of three SARS-CoV-2 pathogen detection EQA schemes in Austria between May 18, 2020, and Feb 20, 2023. We calculated the overall rates of false and true-negative, false and true-positive, and inconclusive results. We then assessed laboratory performance by estimating the sensitivity by testing whether significant variation in the odds of obtaining a true-positive result could be explained by virus concentration, laboratory type, or assay format. We also assessed whether laboratory performance changed over time. FINDINGS: 4371 (93·7%) of 4663 qPCR test results were true-positive, 241 (5·2%) were false-negative, and 51 (1·1%) were inconclusive. The mean per-sample sensitivity was 99·7% in samples with high virus concentrations (1383 [99·4%] true-positive, three [0·2%] false-negative, and five [0·4%] inconclusive results for 1391 tests in which the sample cycle threshold was ≤32), whereas detection rates were lower in samples with low virus concentrations (mean per-sample sensitivity 92·5%; 2988 [91·3%] true-positive, 238 [7·3%] false-negative, and 46 [1·4%] inconclusive results for 3272 tests in which the cycle threshold was >32). Of the 1645 results expected to be negative, 1561 (94·9%) were correctly reported as negative, 10 (0·6%) were incorrectly reported as positive, and 74 (4·5%) were reported as inconclusive. Notably, the overall performance of the tests did not change significantly over time. The odds of reporting a correct result were 2·94 (95% CI 1·75-4·96) times higher for a medical laboratory than for a non-medical laboratory, and 4·60 (2·91-7·41) times greater for automated test systems than for manual test systems. Automated test systems within medical laboratories had the highest sensitivity when compared with systems requiring manual intervention in both medical and non-medical laboratories. INTERPRETATION: High rates of false-negativity in all PCR analyses evaluated in comprehensive, multiple, and repeated EQA schemes outline a clear path for improvement in the future. The performance of some laboratories (eg, non-medical laboratories or those using non-automated test systems) should receive additional scrutiny-for example, by requiring additional EQA schemes for certification or accreditation-if the aggregated data from EQA rounds suggest lower sensitivity than that recorded by others. This strategy will provide assurances that epidemiological data as a whole are reliable when testing on such a large scale. Although performance did not improve over time, we cannot exclude extenuating circumstances-such as shortages and weakened supply chains-that could have prevented laboratories from seeking alternative methods to improve performance. FUNDING: None.


Subject(s)
COVID-19 , Nucleic Acids , Humans , COVID-19/diagnosis , COVID-19/epidemiology , SARS-CoV-2/genetics , Retrospective Studies , Pandemics , Austria/epidemiology
7.
Front Immunol ; 14: 1215868, 2023.
Article in English | MEDLINE | ID: mdl-37533865

ABSTRACT

Introduction: Torque teno virus (TTV) replication is controlled by immune status, mirroring a degree of immunosuppression after solid organ transplantation. TTV viraemia (TTVv) was associated with acute cellular rejection and infection within the first year after liver transplantation (LT). Long-term data on TTV after LT and correlation with graft injury from protocol biopsies are limited. Methods: One hundred plasma samples paired with graft biopsies from a prospective single-center biorepository were analyzed. Results: The median time post-LT was 23 months (range, 2-298). TTVv was detectable in 97%. TTVv decreased over time after LT and showed a significant decline from year 1 to later time points. Hence, TTVv correlated negatively with histologic liver fibrosis (liver allograft fibrosis and Ishak scores) and positively with the overall immunosuppression degree quantified by an immunosuppression score in the first year after LT. There was no association with dosages or trough levels of single immunosuppressants. The pharmacodynamic marker TTVv did not correlate with pharmacokinetic assessments of immunosuppression degree [calcineurin inhibitor (CNI) trough levels or immunosuppressant dosages]-our clinical gold standards to guide immunosuppressive therapy. TTVv was independently associated with histologically proven liver fibrosis after LT in the first year after LT in multivariate analysis. Discussion: The independent association of histological graft fibrosis with lower TTVv in year 1 underscores that a pharmacodynamic marker would be preferable to individualize immunosuppression after LT. However, a high variability of TTVv at the low immunosuppression doses given after the first year precludes TTV as a clinically useful marker after LT in the long-term liver transplant recipients.


Subject(s)
Liver Transplantation , Torque teno virus , Humans , Liver Transplantation/adverse effects , Viremia , Prospective Studies , Liver Cirrhosis/etiology , Liver Cirrhosis/surgery , Immunosuppressive Agents/adverse effects
8.
Lancet Microbe ; 4(7): e552-e562, 2023 07.
Article in English | MEDLINE | ID: mdl-37156257

ABSTRACT

During an epidemic, individual test results form the basis of epidemiological indicators such as case numbers or incidence. Therefore, the accuracy of measures derived from these indicators depends on the reliability of individual results. In the COVID-19 pandemic, monitoring and evaluating the performance of the unprecedented number of testing facilities in operation, and novel testing systems in use, was urgently needed. External quality assessment (EQA) schemes are unique sources of data reporting on testing performance, and their providers are recognised contacts and support for test facilities (for technical-analytical topics) and health authorities (for planning the monitoring of infection diagnostics). To identify information provided by SARS-CoV-2 genome detection EQA schemes that is relevant for public health microbiology, we reviewed the current literature published in PubMed between January, 2020, and July, 2022. We derived recommendations for EQA providers and their schemes for best practices to monitor pathogen-detection performance in future epidemics. We also showed laboratories, test facilities, and health authorities the information and benefits they can derive from EQA data, and from the non-EQA services of their providers.


Subject(s)
COVID-19 , Pandemics , Humans , Reproducibility of Results , SARS-CoV-2/genetics , COVID-19/diagnosis , COVID-19/epidemiology , Laboratories
9.
J Clin Virol ; 162: 105428, 2023 05.
Article in English | MEDLINE | ID: mdl-36989730

ABSTRACT

BACKGROUND: Immunosuppressed individuals such as kidney transplant recipients (KTR) and hemodialysis patients (DP) show impaired immune responses to COVID-19 vaccination. Plasma Torque Teno Virus (TTV) DNA load is used as surrogate for the individual degree of immunosuppression. We now assessed the association of TTV load at time of COVID-19 vaccination with humoral and cellular immune response rates to vaccination in KTR, DP, and healthy medical personnel (MP). METHODS: A total of 100 KTR, 115 DP and 54 MP were included. All were SARS-CoV-2 seronegative at the time of vaccination with either BNT162b2 or mRNA-1273. Plasma TTV loads were assessed at the time of first vaccination. After two-dose vaccination, seroconversion (de novo detection of SARS-CoV-2 S1-IgA and/or IgG) was determined. In addition, cellular responses as assessed by interferon γ release and neutralizing antibodies were assessed in a subset of participants. ROC analyses were performed to define TTV load cut-offs predicting specific immune responses to vaccination. RESULTS: Plasma TTV loads at the time of first vaccination were negatively associated with seroconversion after two-dose vaccination in KTR (OR 0.87, 95% CI 0.76-0.99). TTV loads were significantly lower in KTR who developed humoral and cellular immune responses to vaccination compared to non-responders (p = 0.0411 and 0.0030, respectively). Of patients with TTV loads above 106 copies/ml, none developed cellular immune responses against SARS-CoV-2, and only 2 of 17 (12%) seroconverted in response to vaccination. CONCLUSION: Plasma TTV loads at the time of first vaccination in immunosuppressed individuals may be useful to predict individual vaccine-specific immune responses.


Subject(s)
COVID-19 , Kidney Transplantation , Humans , BNT162 Vaccine , COVID-19/prevention & control , COVID-19 Vaccines , SARS-CoV-2 , Vaccination , RNA, Messenger , Transplant Recipients , Antibodies, Viral
11.
J Clin Virol ; 158: 105348, 2023 01.
Article in English | MEDLINE | ID: mdl-36463684

ABSTRACT

BACKGROUND: Torque Teno virus (TTV) is non-pathogenic, highly prevalent and reflects the immune status of its host. TTV plasma load was suggested for risk stratification of graft rejection and infection post kidney-transplantation, for which most studies applied an in-house PCR. Recently, a commercial PCR was CE-certified for clinical use. The present study was designed to assess the performance of TTV load as quantified by the commercial PCR in the prediction of graft rejection and infection. METHODS: Patients and events were selected from the prospective TTV-POET trial, including 683 consecutive adult recipients of a kidney-graft transplanted at the Medical University Vienna, 2016-2020. TTV was quantified in plasma drawn in Months 4-12 post-transplant by in-house and commercial PCR and associated with consecutive infections and graft rejections until Month 12 post-transplantation. RESULTS: A total of 342 samples from 314 patients with 85 biopsies (rejection, n = 18) and 79 infectious events were assessed. The two PCRs were highly associated (estimate 0.91, 95%CI 0.89-0.93), with a mean difference of 1.38 log10 copies/mL (95%CI 1.46-1.30). The risk of rejection decreased by 25% with every log10 increase in TTV load as quantified by commercial PCR (RR 0.75, 95%CI 0.67-0.85), and the risk of infection increased by 6% (RR 1.06, 95%CI 1.00-1.12). CONCLUSION: These data support the value of TTV quantification by commercial PCR for the risk stratification of graft rejection and infection in the first year post kidney-transplantation. The test performance determined within this study may serve to design clinical trials and subsequently, support application in clinical routine.


Subject(s)
DNA Virus Infections , Kidney Transplantation , Torque teno virus , Adult , Humans , Kidney Transplantation/adverse effects , Torque teno virus/genetics , Prospective Studies , Polymerase Chain Reaction , Risk Assessment , DNA, Viral
12.
J Clin Virol ; 158: 105352, 2023 01.
Article in English | MEDLINE | ID: mdl-36525853

ABSTRACT

BACKGROUND: The detection of SARS-CoV-2 vRNA in clinical samples has relied almost exclusively on RT-qPCR as the gold standard test. Published results from various external quality assessments ("ring trials") worldwide have shown that there is still a large variability in results reported for the same samples. As reference standards of SARS-CoV-2 RNA are available, we tested whether using standard curves to convert Ct values into copies/mL (cp/mL) improved harmonization. METHODS: Nine laboratories using 23 test systems (15 of which were unique) prepared standard dilution curves to convert Ct values of 13 SARS-CoV-2 positive samples to cp/mL (hereafter IU/mL). The samples were provided in three rounds of a virus genome detection external quality assessment (EQA) scheme. We tested the precision and accuracy of results reported in IU/mL, and attempted to identify the sources of variability. RESULTS: Reporting results as IU/mL improved the precision of the estimated concentrations of all samples compared to reporting Ct values, although some inaccuracy remained. Variance analysis showed that nearly all variability in data was explained by individual test systems within individual laboratories. When controlling for this effect, there was no significant difference between all other factors tested (test systems, EQA rounds, sample material). CONCLUSIONS: Converting results to copies/mL improved precision across laboratory test systems. However, it seems the results are still very specific to test systems within laboratories. Further efforts could be made to improve accuracy and achieve full harmonization across diagnostic laboratories.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , SARS-CoV-2/genetics , COVID-19/diagnosis , RNA, Viral/genetics , RNA, Viral/analysis , COVID-19 Testing , Laboratories , Sensitivity and Specificity
13.
Viruses ; 14(7)2022 07 09.
Article in English | MEDLINE | ID: mdl-35891489

ABSTRACT

Human cytomegalovirus (CMV) utilizes different glycoproteins to enter into fibroblast and epithelial cells. A trimer of glycoproteins H, L, and O (gH/gL/gO) is required for entry into all cells, whereas a pentamer of gH/gL/UL128/UL130/UL131A is selectively required for infection of epithelial, endothelial, and some myeloid-lineage cells, but not of fibroblasts. Both complexes are of considerable interest for vaccine and immunotherapeutic development but present a conundrum: gH/gL-specific antibodies have moderate potency yet neutralize CMV entry into all cell types, whereas pentamer-specific antibodies are more potent but do not block fibroblast infection. Which cell types and neutralizing activities are important for protective efficacy in vivo remain unclear. Here, we present evidence that certain CMV strains have evolved polymorphisms in gO to evade trimer-specific neutralizing antibodies. Using luciferase-tagged variants of strain TB40/E in which the native gO is replaced by gOs from other strains, we tested the effects of gO polymorphisms on neutralization by monoclonal antibodies (mAbs) targeting four independent epitopes in gH/gL that are common to both trimer and pentamer. Neutralization of fibroblast entry by three mAbs displayed a range of potencies that depended on the gO type, a fourth mAb failed to neutralize fibroblast entry regardless of the gO type, while neutralization of epithelial cell entry by all four mAbs was potent and independent of the gO type. Thus, specific polymorphisms in gO protect the virus from mAb neutralization in the context of fibroblast but not epithelial cell entry. No influence of gO type was observed for protection against CMV hyperimmune globulin or CMV-seropositive human sera, suggesting that antibodies targeting protected gH/gL epitopes represent a minority of the polyclonal neutralizing repertoire induced by natural infection.


Subject(s)
Cytomegalovirus Infections , Cytomegalovirus , Membrane Glycoproteins , Viral Envelope Proteins , Antibodies, Monoclonal , Antibodies, Neutralizing , Epitopes/metabolism , Fibroblasts , Humans , Membrane Glycoproteins/metabolism , Viral Envelope Proteins/metabolism , Virus Internalization
15.
Clin Chem Lab Med ; 60(8): 1308-1312, 2022 07 26.
Article in English | MEDLINE | ID: mdl-35599330

ABSTRACT

OBJECTIVES: Results of earlier external quality assessment (EQA) rounds suggested remarkable differences in the sensitivity of SARS-CoV PCR assays. Although the test systems are intended to detect SARS-CoV-2 in individual samples, screening is often applied to sample pools to increase efficiency and decrease costs. However, it is unknown to what extent these tests actually meet the manufacturer's specifications for sensitivity and how they perform when testing sample pools. METHODS: The sensitivity of assays in routine use was evaluated with a panel of positive samples in a round of a SARS-CoV-2 virus genome detection EQA scheme. The panel consisted of samples at or near the lower limit of detection ("weakly positive"). Laboratories that routinely test sample pools were asked to also analyze the pooled EQA samples according to their usual pool size and dilution method. RESULTS: All participants could detect a highly positive patient-derived sample (>106 copies/mL). Most (96%) of the test systems could detect at least 1,000 copies/mL, meeting the minimum acceptable benchmark, and many (94%) detected the vRNA in a sample with lower concentration (500 copies/mL). The false negative ratio increased to 16 and 26% for samples with 100 and 50 copies/mL, respectively. CONCLUSIONS: The performance of most assays met or exceeded their specification on sensitivity. If assays are to be used to analyze sample pools, the sensitivity of the assay and the number of pooled samples must be balanced.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19 Testing , Humans , SARS-CoV-2/genetics , Sensitivity and Specificity
16.
Viruses ; 14(5)2022 04 21.
Article in English | MEDLINE | ID: mdl-35632596

ABSTRACT

Human cytomegalovirus (HCMV) can cause significant end-organ diseases such as pneumonia in HIV-exposed infants. Complex viral factors may influence pathogenesis including: a large genome with a sizeable coding capacity, numerous gene regions of hypervariability, multiple-strain infections, and tissue compartmentalization of strains. We used a whole genome sequencing approach to assess the complexity of infection by comparing high-throughput sequencing data obtained from respiratory and blood specimens of HIV-exposed infants with severe HCMV pneumonia with those of lung transplant recipients and patients with hematological disorders. There were significantly more specimens from HIV-exposed infants showing multiple HCMV strain infection. Some genotypes, such as UL73 G4B and UL74 G4, were significantly more prevalent in HIV-exposed infants with severe HCMV pneumonia. Some genotypes were predominant in the respiratory specimens of several patients. However, the predominance was not statistically significant, precluding firm conclusions on anatomical compartmentalization in the lung.


Subject(s)
Cytomegalovirus Infections , HIV Infections , Pneumonia , Cytomegalovirus/genetics , Cytomegalovirus Infections/epidemiology , HIV Infections/complications , Humans , Infant , South Africa/epidemiology
17.
Transplantation ; 106(10): 1940-1951, 2022 10 01.
Article in English | MEDLINE | ID: mdl-35509090

ABSTRACT

Potent immunosuppressive drugs have been introduced into clinical care for solid organ transplant recipients. It is now time to guide these drugs on an individual level to optimize their efficacy. An ideal tool simultaneously detects overimmunosuppression and underimmunosuppression, is highly standardized, and is straightforward to implement into routine. Randomized controlled interventional trials are crucial to demonstrate clinical value. To date, proposed assays have mainly focused on the prediction of rejection and were based on the assessment of few immune compartments. Recently, novel tools have been introduced based on a more integrated approach to characterize the immune function and cover a broader spectrum of the immune system. In this respect, the quantification of the plasma load of a highly prevalent and apathogenic virus that might reflect the immune function of its host has been proposed: the torque teno virus (TTV). Although TTV control is driven by T cells, other major immune compartments might contribute to the hosts' response. A standardized in-house polymerase chain reaction and a conformité européenne-certified commercially available polymerase chain reaction are available for TTV quantification. TTV load is associated with rejection and infection in solid organ transplant recipients, and cutoff values for risk stratification of such events have been proposed for lung and kidney transplantation. Test performance of TTV load does not allow for the diagnosis of rejection and infection but is able to define at-risk patients. Hitherto TTV load has not been used in interventional settings, but two interventional randomized controlled trials are currently testing the safety and efficacy of TTV-guided immunosuppression.


Subject(s)
Organ Transplantation , Torque teno virus , DNA, Viral/genetics , Humans , Immunosuppression Therapy , Monitoring, Immunologic , Organ Transplantation/adverse effects , Torque teno virus/genetics , Viral Load
18.
Microbiome ; 10(1): 66, 2022 04 23.
Article in English | MEDLINE | ID: mdl-35459224

ABSTRACT

BACKGROUND: The virome of lung transplant recipients (LTRs) under immunosuppressive therapy is dominated by non-pathogenic Anelloviridae and further includes several pathogenic viruses such as Herpesviruses or respiratory viruses. It is unclear whether the donor-derived virome in the transplanted lung influences recipient virome dynamics in other body compartments and if so, to which degree. Likewise, it is unknown whether dependencies exist among virus populations that mutually shape viral loads and kinetics. RESULTS: To address these questions, we characterized viral communities in airways and plasma of 49 LTRs and analyzed their abundance patterns in a data modeling approach. We found distinct viral clusters that were specific for body compartments and displayed independent dynamics. These clusters robustly gathered specific viral species across the patient cohort. In the lung, viral cluster abundance associated with time after transplantation and we detected mutual exclusion of viral species within the same human host. In plasma, viral cluster dynamics were associated with the indication for transplantation lacking significant short-time changes. Interestingly, pathogenic viruses in the plasma co-occurred specifically with Alpha torque virus genogroup 4 and Gamma torque virus strains suggesting shared functional or ecological requirements. CONCLUSIONS: In summary, the detailed analysis of virome dynamics after lung transplantation revealed host, body compartment, and time-specific dependency patterns among viruses. Furthermore, our results suggested genetic adaptation to the host microenvironment at the level of the virome and support the hypothesis of functional complementarity between Anellovirus groups and other persistent viruses. Video abstract.


Subject(s)
Lung Transplantation , Humans , Lung , Metagenome , Metagenomics/methods , Transplant Recipients
19.
Clin Chem Lab Med ; 60(2): 291-298, 2022 01 27.
Article in English | MEDLINE | ID: mdl-34751522

ABSTRACT

OBJECTIVES: Mutation-specific PCR assays have quickly found their way into laboratory diagnostics due to their capacity to be a fast, easy to implement and high-throughput method for the detection of known SARS-CoV-2 variants of concern (VoCs). However, little is known about the performance of such assays in routine laboratory analysis. METHODS: The results reported in a recent round of an external quality assessment (EQA) scheme for SARS-CoV-2 mutation-specific PCR were retrospectively analyzed. For the determination of individual variant-specific sequences as well as for the interpretation results for certain virus variants, correct, incorrect, and unreported results were evaluated, and their possible causes were investigated. RESULTS: A total of 34 laboratories participated in this study. For five samples containing the VoC Alpha + E484K, Beta, Gamma, Delta, or B.1.1.318 (as a variant of interest), 848 results for SARS-2-CoV mutation detection were reported, 824 (97.2%, range per sample 88-100%) of which were correct. Melting curve assays gave 99% correct results, real-time RT-qPCR 94%, microarray-based assays 100%, and MALDI-TOF MS 96%. A total of 122/167 (73%) reported results for SARS-CoV-2 variant determination were correct. Of the 45 inconclusive or incorrect results, 33 (73%) were due to inadequate selection of targets that did not allow identification of contemporary VoC, 11 (24%) were due to incorrect results, and one (3%) was due to correct results of mutation-specific PCR. CONCLUSIONS: Careful and up-to-date selection of the targets used in mutation-specific PCR is essential for successful detection of current SARS-CoV-2 variants.


Subject(s)
COVID-19 , SARS-CoV-2/genetics , COVID-19/virology , Humans , Mutation , Real-Time Polymerase Chain Reaction , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL