Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Pacing Clin Electrophysiol ; 47(2): 292-299, 2024 02.
Article in English | MEDLINE | ID: mdl-38078545

ABSTRACT

BACKGROUND: Cardiac implantable electronic device (CIED) procedures are prone to complications. In our study, we investigated the effect of body mass index (BMI) on CIED-related complications. METHODS: 1676 patients who had undergone CIED surgery (de novo implantation, system upgrade, generator change, pocket revision or lead replacement) at two heart centers in Turkey and met the study criteria were included in our study. For analysis of primary and secondary endpoints, patients were classified as non-obese (BMI < 25 kg/m2 ), overweight (25 ≤ BMI < 30 kg/m2 ), and obese (BMI ≥ 30 kg/m2 ). The primary endpoint was accepted as cumulative events, including the composite of clinically significant hematoma (CSH), pericardial effusion or tamponade, pneumothorax, and infection related to the device system. Secondary outcomes included each component of cumulative events. RESULTS: The rate of cumulative events, defined as primary outcome, was higher in the obese patient group, and we found a significant difference between the groups (3.0%, 4.3%, 8.9%, p = .001). CSH and pneumothorax rates were significantly higher in the obese patient group (0.3%, 0.9%, 1.9%, p = .04; 1.0%, 1.4%, 3.3%, p = .04, respectively). According to our multivariate model analysis; gender (OR:1.882, 95%CI:1.156-3.064, p = .01), hypertension (OR:4.768, 95%CI:2.470-9.204, p < .001), BMI (OR:1.069, 95%CI:1.012-1.129, p = .01) were independent predictors of cumulative events rates. CONCLUSIONS: Periprocedural complications associated with CIED (especially hematoma and pneumothorax) are more common in the group with high BMI.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Pericardial Effusion , Pneumothorax , Humans , Defibrillators, Implantable/adverse effects , Body Mass Index , Pneumothorax/epidemiology , Pneumothorax/etiology , Obesity/complications , Hematoma/etiology , Pacemaker, Artificial/adverse effects , Retrospective Studies
2.
Aging Clin Exp Res ; 35(11): 2445-2452, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37599325

ABSTRACT

BACKGROUND: In this study, we investigated whether there is a higher incidence of cardiac implantable electronic devices (CIED) procedures related complications in older (≥ 75 years) than in younger (< 75 years) patients. METHODS: This retrospective cohort study enrolled patients who had undergone CIED procedures (de novo implantation, system upgrade, generator substitution, pocket revision or lead replacement) at two heart centers in Turkey between January 2011 and May 2023. The primary composite endpoint included clinically significant hematoma (CSH), pericardial effusion or tamponade, pneumothorax, and infection related to the device system. Secondary outcomes included each component of the composite end point. RESULTS: The overall sample included 1923 patients (1419 < 75 years and 504 aged ≥ 75 years). There was no difference between the groups in terms of cumulative events defined as primary outcome (3.5% vs. 4.4%, p = 0.393). Infection related to device system was significantly higher in the ≥ 75 age group (1.8% vs. 3.4%, p = 0.034). There was no significant difference between the groups in terms of clinically significant hematoma and pneumothorax (0.7% vs. 0.4%, p = 0.451, 1.4% vs. 1.0%, p = 0.477, respectively). In multivariate model analysis, no association was found between age ≥ 75 years and infection related to the device system. CONCLUSION: Infection rates were relatively higher in the patient group aged ≥ 75 years. This patient group should be evaluated more carefully in terms of infection development before and after the procedure.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Pneumothorax , Humans , Aged , Retrospective Studies , Hematoma , Aging , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...