Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
AJNR Am J Neuroradiol ; 21(5): 964-7, 2000 May.
Article in English | MEDLINE | ID: mdl-10815678

ABSTRACT

BACKGROUND AND PURPOSE: Despite improvements in noninvasive imaging, some patients with contraindications to iodine-based contrast material still require angiography for the evaluation of carotid stenosis. Our aim was to assess the utility of gadopentetate dimeglumine as an intraarterial contrast agent in common carotid angiography. METHODS: Twelve patients with suspected carotid artery stenosis were enrolled in the study. In addition to the standard injection sequences with iohexol, common carotid arteriograms were obtained after administration of gadopentetate dimeglumine. Neurologic status and vital signs were monitored during and for 6 hours after the examination. For each injection, five independent observers, blinded to the contrast agent used, measured the percentage of carotid stenosis and assessed their confidence in grading the stenosis, the overall quality of the examination, and, in cases of decreased quality, the reason(s) for it. Statistical analysis was done with paired and unpaired t-tests with equal variances. RESULTS: No patient had an adverse clinical outcome, and measurements of carotid artery stenosis showed no statistically significant differences between the gadopentetate dimeglumine and iohexol examinations. Overall image quality and observer confidence in measurements of stenosis on the gadolinium-based studies were slightly but significantly lower than those of identical iodine-based studies. CONCLUSION: Gadopentetate dimeglumine may be an alternative to iodine in selected patients undergoing carotid angiography. Although overall image quality of the gadolinium studies is slightly inferior to that of the iohexol studies, measurements of carotid artery stenosis are similar for the two examinations.


Subject(s)
Angiography, Digital Subtraction , Carotid Stenosis/diagnostic imaging , Contrast Media , Gadolinium DTPA , Adult , Carotid Artery, Common/diagnostic imaging , Female , Humans , Iohexol , Male , Sensitivity and Specificity
2.
Invest Radiol ; 35(1): 86-9, 2000 Jan.
Article in English | MEDLINE | ID: mdl-10639040

ABSTRACT

RATIONALE AND OBJECTIVES: To evaluate the use of a new thrombus-specific ultrasound contrast agent, MRX-408, in the ultrasonic detection of thrombus in arteriovenous (AV) fistulae. METHODS: Six purpose-bred mongrels with two AV fistulae each were imaged with gray-scale ultrasound 7 weeks after graft implantation before and after the intravenous bolus injection of MRX-408 (a GPIIb receptor-targeted ultrasound contrast agent). Pre- and postcontrast videotaped segments were randomized and reviewed by four radiologists blinded to the presence of thrombus in the grafts. RESULTS: After the use of MRX-408, there was improved visualization of thrombus within the grafts (P < 0.0001). This was due to the enhancement of the thrombus (P < 0.0001). The improved visualization and contrast enhancement were more marked in the grafts that contained thrombus nonhyperechoic to surrounding soft tissues. CONCLUSIONS: MRX-408 demonstrated better visualization of thrombus within AV fistulae. This was shown in both patent and occluded grafts. These results are encouraging and suggest that this contrast agent merits further development.


Subject(s)
Contrast Media , Graft Occlusion, Vascular/diagnostic imaging , Phospholipids , Thrombosis/diagnostic imaging , Animals , Arteriovenous Shunt, Surgical , Dogs , Hindlimb , Microspheres , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...