Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Innov Surg Sci ; 9(1): 25-35, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38826630

ABSTRACT

Objectives: Intraoperative monitoring of blood flow (BF) remains vital to guiding surgical decisions. Here, we report the use of SurgeON™ Blood Flow Monitor (BFM), a prototype system that attaches to surgical microscopes and implements laser speckle contrast imaging (LSCI) to noninvasively obtain and present vascular BF information in real-time within the microscope's eyepiece. Methods: The ability of SurgeON BFM to monitor BF status during reversible vascular occlusion procedures was investigated in two large animal models: occlusion of saphenous veins in six NZW rabbit hindlimbs and clipping of middle cerebral artery (MCA) branches in four Dorset sheep brain hemispheres. SurgeON BFM acquired, presented, and stored LSCI-based blood flow velocity index (BFVi) data and performed indocyanine green video angiography (ICG-VA) for corroboration. Results: Stored BFVi data were analyzed for each phase: pre-occlusion (baseline), with the vessel occluded (occlusion), and after reversal of occlusion (re-perfusion). In saphenous veins, BFVi relative to baseline reduced to 5.2±3.7 % during occlusion and returned to 102.9±14.9 % during re-perfusion. Unlike ICG-VA, SurgeON BFM was able to monitor reduced BFVi and characterize re-perfusion robustly during five serial occlusion procedures conducted 2-5 min apart on the same vessel. Across four sheep MCA vessels, BFVi reduced to 18.6±7.7 % and returned to 120.1±27.8 % of baseline during occlusion and re-perfusion phases, respectively. Conclusions: SurgeON BFM can noninvasively monitor vascular occlusion status and provide intuitive visualization of BF information in real-time to an operating surgeon. This technology may find application in vascular, plastic, and neurovascular surgery.

2.
Ophthalmol Sci ; 4(4): 100463, 2024.
Article in English | MEDLINE | ID: mdl-38591050

ABSTRACT

Purpose: To determine the correlation between blood flow metrics measured by intravenous fluorescein angiography (IVFA) and the blood flow velocity index (BFVi) obtained by laser speckle contrast imaging (LSCI) in infants with retinopathy of prematurity (ROP). Design: Prospective comparative pilot study. Subjects: Seven eyes from 7 subjects with ROP. Methods: Unilateral LSCI and IVFA data were obtained from each subject in the neonatal intensive care unit. Five LSCI-based metrics and 5 IVFA-based metrics were extracted from images to quantify blood flow patterns in the same region of interest. Correlation between LSCI-based and IVFA-based blood flow metrics was compared between 2 subgroups of ROP severity: moderate ROP (defined as stage ≤ 2 without Plus disease) and severe ROP (defined as stage ≥3 or Plus disease). Main Outcome Measures: Pearson and Kendall rank correlation coefficients between IVFA and LSCI metrics; Student t test P values comparing LSCI metrics between "severe" and "moderate" ROP groups. Results: Pearson correlations between IVFA and LSCI included arterial-venous transit time (AVTT) and peak BFVi (pBFVi; r = -0.917; P = 0.004), AVTT and dip BFVi (dBFVi; r = -0.920; P = 0.003), AVTT and mean BFVi (r = -0.927- P = 0.003), and AVTT and volumetric rise index (r = -0.779; P = 0.039). Kendall rank correlation between AVTT and dBFVi was r = -0.619 (P = 0.051). pBFVi was higher in severe ROP than in moderate ROP (8.4 ± 0.6 and 4.4 ± 1.8, respectively; P = 0.0045 using the 2-sample t test with pooled variance and P = 0.0952 using the Wilcoxon rank-sum test). Conclusions: Correlation was found between blood flow metrics obtained by IVFA and noninvasive LSCI techniques. We demonstrate the feasibility of obtaining quantitative metrics using LSCI in infants with ROP in this pilot study; however, further investigation is needed to evaluate its potential use in clinical assessment of ROP severity. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

SELECTION OF CITATIONS
SEARCH DETAIL
...