1.
Eur J Vasc Endovasc Surg ; 54(4): 513-522, 2017 10.
Article in English | MEDLINE | ID: mdl-28843984

ABSTRACT

BACKGROUND: Arteriovenous fistulae are the currently recommended gold standard vascular access modality for haemodialysis because of their prolonged patency, improved durability, and low risk of infection for those that mature. However, notable disadvantages are observed in terms of protracted maturation time, associated high rates of catheter use, and substantial abandonment rates. The aim of this study was to quantitatively summarize the outcomes of fistula patency, infection, maturation, and abandonment published in the scientific literature. METHODS: This was a systematic review and meta-analyses of studies evaluating fistula outcomes. Literature searches were conducted in multiple databases to identify observational and interventional studies of mean fistula patency rates at 1 year, infection risk, maturation time, and abandonment. Digitisation software was used to simulate individual patient level data from Kaplan-Meier survival plots. RESULTS: Over 8000 studies were reviewed, and from these, 318 studies were included comprising 62,712 accesses. For fistulas the primary unassisted, primary assisted, and secondary patency rates at one year were 64%, 73% and 79% respectively, however not all fistulas reported as patent could be confirmed as being clinically useful for dialysis (i.e. functional patency). For fistulas that were reported as mature, mean time to maturation was 3.5 months, however only 26% of created fistulas were reported as mature at 6 months and 21% of fistulas were abandoned without use. Overall risk of infection in fistula patients was 4.1% and the overall rate per 100 access days was 0.018. CONCLUSIONS: Reported fistula patency rates may overstate their potential clinical utility when time to maturation, maturation rate, abandonment and infection are considered. Protracted maturation times, abandonment and infection all have a significant impact on evaluating the clinical utility of fistula creation. A rigorous and consistent set of outcomes definitions for hemodialysis access are necessary to clarify factors contributing to fistula success and the clinical consequence of fistula failure.


Subject(s)
Arteriovenous Shunt, Surgical , Renal Dialysis , Humans , Renal Insufficiency/complications , Renal Insufficiency/therapy , Risk Factors , Vascular Patency
2.
Eur J Vasc Endovasc Surg ; 44(1): 93-9, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22580402

ABSTRACT

OBJECTIVE: To report a multi-center experience with the novel Hemodialysis Reliable Outflow (HeRO) vascular access graft. MATERIALS AND METHODS: Four centers conducted a retrospective review of end stage renal disease patients who received the HeRO device from implant to last available follow-up. Data is available on 164 patients with an accumulated 2092.1 HeRO implant months. RESULTS: At 6 months, HeRO primary and secondary patency is 60% and 90.8%, respectively and at 12 months, 48.8% and 90.8%, respectively. At 24 months, HeRO had a primary patency of 42.9% and secondary patency was 86.7%. Interventions to maintain or re-establish patency have been required in 71.3% of patients (117/164) resulting in an intervention rate of 1.5/year. Access related infections have been reported in 4.3% patients resulting in a rate of 0.14/1000 implant days. CONCLUSIONS: In our experience the HeRO device has performed comparably to standard AVGs and has proven superior to TDCs in terms of patency, intervention, and infection rates when compared to the peer-reviewed literature. As an alternative to catheter dependence as a means for hemodialysis access, this graft could reduce the morbidity and mortality associated with TDCs and have a profound impact on the costs associated with catheter related infections and interventions.


Subject(s)
Blood Vessel Prosthesis , Catheters, Indwelling , Equipment Failure Analysis/methods , Kidney Failure, Chronic/therapy , Renal Dialysis/instrumentation , Adult , Aged , Aged, 80 and over , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Young Adult