Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
2.
J Anal Toxicol ; 41(3): 181-195, 2017 Apr 01.
Article in English | MEDLINE | ID: mdl-27881618

ABSTRACT

An analytical method using ultra performance liquid chromatography (UPLC) quadrupole time-of-flight mass spectrometry (QTOF-MS) was developed and validated for the targeted toxicological screening and quantification of commonly used pharmaceuticals and drugs of abuse in postmortem blood using 100 µL sample. It screens for more than 185 drugs and metabolites and quantifies more than 90 drugs. The selected compounds include classes of pharmaceuticals and drugs of abuse such as: antidepressants, antipsychotics, analgesics (including narcotic analgesics), anti-inflammatory drugs, benzodiazepines, beta-blockers, amphetamines, new psychoactive substances (NPS), cocaine and metabolites. Compounds were extracted into acetonitrile using a salting-out assisted liquid-liquid extraction (SALLE) procedure. The extracts were analyzed using a Waters ACQUITY UPLC coupled with a XEVO QTOF mass spectrometer. Separation of the analytes was achieved by gradient elution using Waters ACQUITY HSS C18 column (2.1 mm x 150 mm, 1.8 µm). The mass spectrometer was operated in both positive and negative electrospray ionization modes. The high-resolution mass spectrometry (HRMS) data was acquired using a patented Waters MSE acquisition mode which collected low and high energy spectra alternatively during the same acquisition. Positive identification of target analytes was based on accurate mass measurements of the molecular ion, product ion, peak area ratio and retention times. Calibration curves were linear over the concentration range 0.05-2 mg/L for basic and neutral analytes and 0.1-6 mg/L for acidic analytes with the correlation coefficients (r2) > 0.96 for most analytes. The limits of detection (LOD) were between 0.001-0.05 mg/L for all analytes. Good recoveries were achieved ranging from 80% to 100% for most analytes using the SALLE method. The method was validated for sensitivity, selectivity, accuracy, precision, stability, carryover and matrix effects. The developed method was tested on a number of authentic forensic samples producing consistent results that correlated with results obtained from other validated methods.


Subject(s)
Chromatography, Liquid/methods , Forensic Toxicology/methods , Mass Spectrometry/methods , Pharmaceutical Preparations/blood , Calibration , Forensic Toxicology/instrumentation , Humans , Illicit Drugs/blood , Illicit Drugs/chemistry , Limit of Detection , Liquid-Liquid Extraction , Pharmaceutical Preparations/chemistry , Reference Standards , Reproducibility of Results
3.
J Anal Toxicol ; 39(3): 219-24, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25595137

ABSTRACT

A rapid, highly sensitive and specific analytical method for the extraction, identification and quantification of nine rodenticides from whole blood has been developed and validated. Commercially available rodenticides in Australia include coumatetralyl, warfarin, brodifacoum, bromadiolone, difenacoum, flocoumafen, difethialone, diphacinone and chlorophacinone. A Waters ACQUITY UPLC TQD system operating in multiple reaction monitoring mode was used to conduct the analysis. Two different ionization techniques, ES+ and ES-, were examined to achieve optimal sensitivity and selectivity resulting in detection by MS-MS using electrospray ionization in positive mode for difenacoum and brodifacoum and in negative mode for all other analytes. All analytes were extracted from 200 µL of whole blood with ethylacetate and separated on a Waters ACQUITY UPLC BEH-C18 column using gradient elution. Ammonium acetate (10 mM, pH 7.5) and methanol were used as mobile phases with a total run time of 8 min. Recoveries were between 70 and 105% with limits of detection ranging from 0.5 to 1 ng/mL. The limit of quantitation was 2 ng/mL for all analytes. Calibration curves were linear within the range 2-200 ng/mL for all analytes with the coefficient of determination ≥0.98. The application of the proposed method using liquid-liquid extraction in a series of clinical investigations and forensic toxicological analyses was successful.


Subject(s)
Chromatography, High Pressure Liquid , Forensic Toxicology/methods , Rodenticides/blood , Spectrometry, Mass, Electrospray Ionization , Tandem Mass Spectrometry , Autopsy , Calibration , Chromatography, High Pressure Liquid/standards , Forensic Toxicology/standards , Humans , Limit of Detection , Reference Standards , Reproducibility of Results , Spectrometry, Mass, Electrospray Ionization/standards , Tandem Mass Spectrometry/standards
SELECTION OF CITATIONS
SEARCH DETAIL
...