Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Chem Commun (Camb) ; 51(25): 5318-21, 2015 Mar 28.
Article in English | MEDLINE | ID: mdl-25503868

ABSTRACT

The first gallium- and calcium-catalyzed Meyer-Schuster rearrangements are described. Under substrate control, the incipient conjugated ketones can be trapped intramolecularly by ß-keto esters or amides to yield cyclic products after aldol condensation or endo-Michael addition. An interesting additive effect that promotes the latter tandem process with calcium has been found.

2.
Hum Exp Toxicol ; 33(1): 74-80, 2014 Jan.
Article in English | MEDLINE | ID: mdl-23584355

ABSTRACT

BACKGROUND: Methanol, acetaldehyde, acetone, and ethanol, which are commonly used as biomarkers of several diseases, in acute intoxications, and forensic settings, can be detected and quantified in biological fluids. Gas chromatography (GC)-mass spectrometry techniques are complex, require highly trained personnel and expensive materials. Gas chromatographic determinations of ethanol, methanol, and acetone have been reported in one study with suboptimal accuracy. Our objective was to improve the assessment of these compounds in human blood using GC with flame ionization detection. METHODS: An amount of 50 µl of blood was diluted with 300 µl of sterile water, 40 µl of 10% sodium tungstate, and 20 µl of 1% sulphuric acid. After centrifugation, 1 µl of the supernatant was injected into the gas chromatograph. We used a dimethylpolysiloxane capillary column of 30 m × 0.25 mm × 0.25 µm. RESULTS: We observed linear correlations from 7.5 to 240 mg/l for methanol, acetaldehyde, and acetone and from 75 to 2400 mg/l for ethanol. Precision at concentrations 15, 60, and 120 mg/l for methanol, acetaldehyde, and acetone and 150, 600, and 1200 mg/ml for ethanol were 0.8-6.9%. Ranges of accuracy were 94.7-98.9% for methanol, 91.2-97.4% for acetaldehyde, 96.1-98.7% for acetone, and 105.5-111.6% for ethanol. Limits of detection were 0.80 mg/l for methanol, 0.61 mg/l for acetaldehyde, 0.58 mg/l for acetone, and 0.53 mg/l for ethanol. CONCLUSION: This method is suitable for routine clinical and forensic practices.


Subject(s)
Acetaldehyde/blood , Acetone/blood , Ethanol/blood , Methanol/blood , Alcohol-Related Disorders/blood , Alcohol-Related Disorders/diagnosis , Biomarkers/blood , Calibration , Flame Ionization , Forensic Medicine/methods , Humans , Limit of Detection , Microchemistry/methods , Reproducibility of Results , Substance Abuse Detection , Substance-Related Disorders/blood , Substance-Related Disorders/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL