Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Neuroeng Rehabil ; 20(1): 162, 2023 12 01.
Article in English | MEDLINE | ID: mdl-38041135

ABSTRACT

BACKGROUND: Robotic hand orthoses (RHO) aim to provide grasp assistance for people with sensorimotor hand impairment during daily tasks. Many of such devices have been shown to bring a functional benefit to the user. However, assessing functional benefit is not sufficient to evaluate the usability of such technologies for daily life application. A comprehensive and structured evaluation of device usability not only focusing on effectiveness but also efficiency and satisfaction is required, yet often falls short in existing literature. Mixed methods evaluations, i.e., assessing a combination of quantitative and qualitative measures, allow to obtain a more holistic picture of all relevant aspects of device usability. Considering these aspects already in early development stages allows to identify design issues and generate generalizable benchmarks for future developments. METHODS: We evaluated the short-term usability of the RELab tenoexo, a RHO for hand function assistance, in 15 users with tetraplegia after a spinal cord injury through a comprehensive mixed methods approach. We collected quantitative data using the Action Research Arm Test (ARAT), the System Usability Scale (SUS), and timed tasks such as the donning process. In addition, qualitative data were collected through semi-structured interviews and user observations, and analyzed with a thematic analysis to enhance the usability evaluation. All insights were attributed and discussed in relation to specifically defined usability attributes such as comfort, ease of use, functional benefit, and safety. RESULTS: The RELab tenoexo provided an immediate functional benefit to the users, resulting in a mean improvement of the ARAT score by 5.8 points and peaking at 15 points improvement for one user (clinically important difference: 5.7 points). The mean SUS rating of 60.6 represents an adequate usability, however, indicating that especially the RHO donning (average task time = 295 s) was perceived as too long and cumbersome. The participants were generally very satisfied with the ergonomics (size, dimensions, fit) of the RHO. Enhancing the ease of use, specifically in donning, increasing the provided grasping force, as well as the availability of tailoring options and customization were identified as main improvement areas to promote RHO usability. CONCLUSION: The short-term usability of the RELab tenoexo was thoroughly evaluated with a mixed methods approach, which generated valuable data to improve the RHO in future iterations. In addition, learnings that might be transferable to the evaluation and design of other RHO were generated, which have the potential to increase the daily life applicability and acceptance of similar technologies.


Subject(s)
Robotic Surgical Procedures , Robotics , Spinal Cord Injuries , Wearable Electronic Devices , Humans , Orthotic Devices
2.
J Neuroeng Rehabil ; 20(1): 101, 2023 08 03.
Article in English | MEDLINE | ID: mdl-37537602

ABSTRACT

BACKGROUND: Assistive robotic hand orthoses can support people with sensorimotor hand impairment in many activities of daily living and therefore help to regain independence. However, in order for the users to fully benefit from the functionalities of such devices, a safe and reliable way to detect their movement intention for device control is crucial. Gesture recognition based on force myography measuring volumetric changes in the muscles during contraction has been previously shown to be a viable and easy to implement strategy to control hand prostheses. Whether this approach could be efficiently applied to intuitively control an assistive robotic hand orthosis remains to be investigated. METHODS: In this work, we assessed the feasibility of using force myography measured from the forearm to control a robotic hand orthosis worn on the hand ipsilateral to the measurement site. In ten neurologically-intact participants wearing a robotic hand orthosis, we collected data for four gestures trained in nine arm configurations, i.e., seven static positions and two dynamic movements, corresponding to typical activities of daily living conditions. In an offline analysis, we determined classification accuracies for two binary classifiers (one for opening and one for closing) and further assessed the impact of individual training arm configurations on the overall performance. RESULTS: We achieved an overall classification accuracy of 92.9% (averaged over two binary classifiers, individual accuracies 95.5% and 90.3%, respectively) but found a large variation in performance between participants, ranging from 75.4 up to 100%. Averaged inference times per sample were measured below 0.15 ms. Further, we found that the number of training arm configurations could be reduced from nine to six without notably decreasing classification performance. CONCLUSION: The results of this work support the general feasibility of using force myography as an intuitive intention detection strategy for a robotic hand orthosis. Further, the findings also generated valuable insights into challenges and potential ways to overcome them in view of applying such technologies for assisting people with sensorimotor hand impairment during activities of daily living.


Subject(s)
Activities of Daily Living , Robotic Surgical Procedures , Humans , Feasibility Studies , Hand/physiology , Myography , Orthotic Devices
3.
IEEE Int Conf Rehabil Robot ; 2022: 1-6, 2022 07.
Article in English | MEDLINE | ID: mdl-36176133

ABSTRACT

With the increasing range of functionalities of advanced assistive technologies (AAT), reliable control and initiation of the desired actions become increasingly challenging for users. In this work, we present an analysis of current practices, user preferences, and usability of AAT intention detection strategies based on a survey among participants with disabilities at the CYBATHLON 2020 Global Edition. We collected data from 35 respondents, using devices in various disciplines and levels of technology maturity. We found that conventional, direct inputs such as buttons and joysticks are used by the majority of AAT (71.4%) due to their simplicity and learnability. However, 22 respondents (62.8%) reported a desire for more natural control using muscle or non-invasive brain signals, and 37.1% even reported an openness to invasive strategies for potentially improved control. The usability of the used strategies in terms of the explored attributes (reliability, mental effort, required learning) was mainly perceived positively, whereas no significant difference was observed across intention detection strategies and device types. It can be assumed that the strategies used during the CYBATHLON realistically represent options to control an AAT in a dynamic, physically and mentally demanding environment. Thus, this work underlines the need for carefully considering user needs and preferences for the selection of intention detection strategies in a context of use outside the laboratory.


Subject(s)
Disabled Persons , Self-Help Devices , Humans , Intention , Reproducibility of Results , Surveys and Questionnaires
4.
Front Neurorobot ; 16: 815693, 2022.
Article in English | MEDLINE | ID: mdl-35264940

ABSTRACT

Wearable robotic upper limb orthoses (ULO) are promising tools to assist or enhance the upper-limb function of their users. While the functionality of these devices has continuously increased, the robust and reliable detection of the user's intention to control the available degrees of freedom remains a major challenge and a barrier for acceptance. As the information interface between device and user, the intention detection strategy (IDS) has a crucial impact on the usability of the overall device. Yet, this aspect and the impact it has on the device usability is only rarely evaluated with respect to the context of use of ULO. A scoping literature review was conducted to identify non-invasive IDS applied to ULO that have been evaluated with human participants, with a specific focus on evaluation methods and findings related to functionality and usability and their appropriateness for specific contexts of use in daily life. A total of 93 studies were identified, describing 29 different IDS that are summarized and classified according to a four-level classification scheme. The predominant user input signal associated with the described IDS was electromyography (35.6%), followed by manual triggers such as buttons, touchscreens or joysticks (16.7%), as well as isometric force generated by residual movement in upper-limb segments (15.1%). We identify and discuss the strengths and weaknesses of IDS with respect to specific contexts of use and highlight a trade-off between performance and complexity in selecting an optimal IDS. Investigating evaluation practices to study the usability of IDS, the included studies revealed that, primarily, objective and quantitative usability attributes related to effectiveness or efficiency were assessed. Further, it underlined the lack of a systematic way to determine whether the usability of an IDS is sufficiently high to be appropriate for use in daily life applications. This work highlights the importance of a user- and application-specific selection and evaluation of non-invasive IDS for ULO. For technology developers in the field, it further provides recommendations on the selection process of IDS as well as to the design of corresponding evaluation protocols.

SELECTION OF CITATIONS
SEARCH DETAIL
...