Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Publication year range
1.
J Clin Med ; 13(7)2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38610601

ABSTRACT

Objectives: To compare complications associated with percutaneous gastrostomies performed using PUSH and PULL techniques, whether endoscopic (PEG) or radiological (PRG), in a tertiary-level hospital. Methods: This was a prospective observational study. Adult patients who underwent percutaneous PULL or PUSH gastrostomy using PEG or PRG techniques at the Virgen del Rocio University Hospital and subsequently followed up in the Nutrition Unit between 2009-2020 were included. X2 tests or Fisher's test were used for the comparison of proportions when necessary. Univariate analysis was conducted to study risk factors for PRG-associated complications. Results: n = 423 (PULL = 181; PUSH = 242). The PULL technique was associated with a higher percentage of total complications (37.6% vs. 23.8%; p = 0.005), exudate (18.2% vs. 11.2%; p = 0.039), and irritation (3.3% vs. 0%; p = 0.006). In the total sample, there were 5 (1.1%) cases of peritonitis, 3 (0.7%) gastrocolic fistulas, and 1 (0.2%) death due to complications associated with gastrostomy. Gender, age, and different indications were not risk factors for a higher number of complications. The most common indications were neurological diseases (35.9%), head and neck cancer (29%), and amyotrophic lateral sclerosis (17.2%). Conclusions: The PULL technique was associated with more total complications than the PUSH technique, but both were shown to be safe techniques, as the majority of complications were minor.

3.
Front Med (Lausanne) ; 10: 1191204, 2023.
Article in English | MEDLINE | ID: mdl-37915325

ABSTRACT

Objectives: To describe the complications associated with the different gastrostomy techniques [endoscopic (PEG), radiologic (PRG), and surgical (SG)] performed in the last 26 years in a terciary hospital. Methods: Retrospective observational study. Patients who underwent gastrostomy at the Virgen del Rocío University Hospital between 1995 and 2021 were included. For PEG, the PULL technique was performed until 2018 and subsequently the PUSH technique predominantly. For PRG, a pigtail catheter was used until 2003, a balloon catheter between 2003 and 2009, and a balloon catheter with gastropexy between 2015 and 2021. For SG, the conventional technique (CSG) was performed until 2009 and since then the laparoscopic assisted percutaneous gastrostomy (PLAG) technique. Descriptive analysis was performed obtaining the median and quartiles of the quantitative variables [P50 (P25-P75)] and the frequency for the qualitative variables [n (%)].The comparison of complications between patients who underwent different techniques was performed with Fisher's test. Results: n = 1,070 (PEG = 608, PRG = 344, SG = 118). The three most frequent indications were head and neck tumors, neurological diseases and gastroesophageal tumors. The percentage of patients who had any complication was 48.9% (PEG-PULL), 23.7% (PEG-PUSH), 38.5% (pigtail PRG), 39.2% (balloon PRG), 29.7% (balloon with gastropexy PRG), 87.3% (CSG), and 41.26% (PLAG). 2 (0.18%) patients died from gastrostomy-related complications. 18(1.68%) presented with peritonitis and 5 (0.4%) presented with gastrocolic fistula. The rest of the complications were minor. Conclusion: Gastrostomy in any of its modalities is currently a safe procedure with a low rate of complications, most of which are minor.

4.
Endoscopy ; 55(7): 591-598, 2023 07.
Article in English | MEDLINE | ID: mdl-36882089

ABSTRACT

BACKGROUND: Removing lumen-apposing metal stents (LAMSs) may be difficult and even harmful, but these features have seldom been analyzed. We aimed to generate a comprehensive assessment of the feasibility and safety of LAMS retrieval procedures. METHODS: A prospective multicenter case series including all technically successfully deployed LAMSs between January 2019 and January 2020 that underwent endoscopic stent removal. All retrieval-related data were prospectively recorded using standardized telephone questionnaires as part of centralized follow-up that ended after stent removal had been performed. Multivariable logistic regression models assessed the potential risk factors for complex removal. RESULTS: For the 407 LAMSs included, removal was attempted in 158 (38.8 %) after an indwell time of 46.5 days (interquartile range [IQR] 31-70). The median (IQR) removal time was 2 (1-4) minutes. Removal was labelled as complex in 13 procedures (8.2 %), although advanced endoscopic maneuvers were required in only two (1.3 %). Complex removal risk factors were stent embedment (relative risk [RR] 5.84, 95 %CI 2.14-15.89; P = 0.001), over-the-wire deployment (RR 4.66, 95 %CI 1.60-13.56; P = 0.01), and longer indwell times (RR 1.14, 95 %CI 1.03-1.27; P = 0.01). Partial and complete embedment were observed in 14 (8.9 %) and five cases (3.2 %), respectively. The embedment rate during the first 6 weeks was 3.1 % (2/65), reaching 15.9 % (10/63) during the following 6 weeks (P = 0.02). The adverse event rate was 5.1 %, including seven gastrointestinal bleeds (5 mild, 2 moderate). CONCLUSIONS: LAMS removal is a safe procedure, mostly requiring basic endoscopic techniques attainable in conventional endoscopy rooms. Referral to advanced endoscopy units should be considered for stents with known embedment or long indwell times, which may require more technically demanding procedures.


Subject(s)
Endoscopy, Gastrointestinal , Stents , Humans , Retrospective Studies , Stents/adverse effects , Endoscopy, Gastrointestinal/adverse effects , Risk Factors , Drainage/adverse effects , Endosonography
5.
Rev Esp Enferm Dig ; 115(8): 457-458, 2023 08.
Article in English | MEDLINE | ID: mdl-36263832

ABSTRACT

We propose this variant of the clip technique as a method that assist traction during endoscopic submucosal dissection (ESD): traction on the mucosa plane using an hemoclip carrying a surgical silk and three rubber bands, before the incision, to allow easier access to the submucosa space. We propose this variant with the intention of facilitating access to ESD quickly and safely for beginners.


Subject(s)
Endoscopic Mucosal Resection , Humans , Endoscopic Mucosal Resection/methods , Treatment Outcome , Dissection/methods , Mucous Membrane , Surgical Instruments
7.
Cancers (Basel) ; 13(24)2021 Dec 07.
Article in English | MEDLINE | ID: mdl-34944773

ABSTRACT

BACKGROUND: Effective biomarkers are needed to enable personalized medicine for pancreatic cancer patients. This study analyzes the prognostic value, in early pancreatic cancer, of single circulating tumor cell (CTC) and CTC clusters from the central venous catheter (CVC) and portal blood (PV). METHODS: In total, 7 mL of PV and CVC blood from 35 patients with early pancreatic cancer were analyzed. CTC were isolated using a positive immunomagnetic selection. The detection and identification of CTC were performed by immunocytochemistry (ICC) and were analyzed by Epi-fluorescence and confocal microscopy. RESULTS: CTC and the clusters were detected both in PV and CVC. In both samples, the CTC number per cluster was higher in patients with grade three or poorly differentiated tumors (G3) than in patients with well (G1) or moderately (G2) differentiated. Patients with fewer than 185 CTC in PV exhibited a longer OS than patients with more than 185 CTC (24.5 vs. 10.0 months; p = 0.018). Similarly, patients with fewer than 15 clusters in PV showed a longer OS than patients with more than 15 clusters (19 vs. 10 months; p = 0.004). These significant correlations were not observed in CVC analyses. CONCLUSIONS: CTC presence in PV could be an important prognostic factor to predict poor prognosis in early pancreatic cancer. In addition, the number of clustered-CTC correlate to a tumor negative differentiation degree and, therefore, could be used as a diagnostic biomarker for pancreatic cancer.

8.
Rev Esp Enferm Dig ; 108(12): 811-812, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27931108

ABSTRACT

The ingestion of cell batteries can cause serious complications (fistula, perforation or stenosis) at the esophageal level. The damage starts soon after ingestion (approximately 2 hours) and is directly related to the amount of time the battery is lodged in said location, the amount of electrical charge remaining in the battery, and the size of the battery itself. Injury is produced by the combination of electrochemical and chemical mechanisms and pressure necrosis. The ingestion of multiple cells and a size > = 20 mm are related with more severe and clinically significant outcomes. A female patient, 39 years old, with a history of previous suicide attempts, was admitted to the Emergency Room with chest pain and dysphagia after voluntary ingestion of 2 cell batteries. Two cell batteries are easily detected in a routine chest X-ray, presenting a characteristic double-ring shadow, or peripheral halo. Urgent oral endoscopy was performed 10 hours after ingestion, showing a greenish-gray lumpy magma-like consistency due to leakage of battery contents. The 2 batteries were sequentially removed with alligator-jaw forceps. After flushing and aspiration of the chemical material, a broad and circumferential injury with denudation of the mucosa and two deep ulcerations with necrosis were observed where the batteries had been. The batteries' seals were eroded, releasing chemical contents. Despite the severity of the injuries, the patient progressed favorably and there was no esophageal perforation. Esophageal impaction of cell batteries should always be considered an endoscopic urgency.


Subject(s)
Burns, Chemical/pathology , Esophagus/injuries , Suicide, Attempted , Adult , Burns, Chemical/diagnostic imaging , Electric Power Supplies , Endoscopy, Gastrointestinal , Esophagus/diagnostic imaging , Esophagus/pathology , Female , Foreign Bodies , Humans , Mucous Membrane/pathology , Ulcer/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...