1.
Echo Res Pract ; 11(1): 14, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38825684

ABSTRACT

BACKGROUND: Echocardiography is widely used to evaluate left ventricular (LV) diastolic function in patients suspected of heart failure. For patients in sinus rhythm, a combination of several echocardiographic parameters can differentiate between normal and elevated LV filling pressure with good accuracy. However, there is no established echocardiographic approach for the evaluation of LV filling pressure in patients with atrial fibrillation. The objective of the present study was to determine if a combination of several echocardiographic and clinical parameters may be used to evaluate LV filling pressure in patients with atrial fibrillation. RESULTS: In a multicentre study of 148 atrial fibrillation patients, several echocardiographic parameters were tested against invasively measured LV filling pressure as the reference method. No single parameter had sufficiently strong association with LV filling pressure to be recommended for clinical use. Based on univariate regression analysis in the present study, and evidence from existing literature, we developed a two-step algorithm for differentiation between normal and elevated LV filling pressure, defining values ≥ 15 mmHg as elevated. The parameters in the first step included the ratio between mitral early flow velocity and septal mitral annular velocity (septal E/e'), mitral E velocity, deceleration time of E, and peak tricuspid regurgitation velocity. Patients who could not be classified in the first step were tested in a second step by applying supplementary parameters, which included left atrial reservoir strain, pulmonary venous systolic/diastolic velocity ratio, and body mass index. This two-step algorithm classified patients as having either normal or elevated LV filling pressure with 75% accuracy and with 85% feasibility. Accuracy in EF ≥ 50% and EF < 50% was similar (75% and 76%). CONCLUSIONS: In patients with atrial fibrillation, no single echocardiographic parameter was sufficiently reliable to be used clinically to identify elevated LV filling pressure. An algorithm that combined several echocardiographic parameters and body mass index, however, was able to classify patients as having normal or elevated LV filling pressure with moderate accuracy and high feasibility.

2.
Heart Rhythm ; 2024 Mar 07.
Article in English | MEDLINE | ID: mdl-38458509

ABSTRACT

BACKGROUND: Risk stratification in Brugada syndrome (BrS) remains controversial. In this respect, the role of the electrophysiology study (EPS) has been a subject of debate. In some centers, it is common practice to use an implantable loop recorder (ILR) after a negative EPS to help in risk stratification. However, the diagnostic value of this approach has never been specifically addressed. OBJECTIVE: The aim of this study was to describe the baseline characteristics and the main findings of a diagnostic workup strategy with an ILR after a negative EPS in BrS. METHODS: We conducted a retrospective international registry including patients with BrS and negative EPS (ie, noninducible ventricular tachycardia or ventricular fibrillation) before ILR monitoring. RESULTS: The study included 65 patients from 8 referral hospitals in The Netherlands, Spain, and the United Kingdom (mean age, 39 ± 16 years; 72% male). The main indication for ILR monitoring was unexplained syncope/presyncope (66.2%). During a median follow-up of 39.0 months (Q1 25.0-Q3 47.6 months), 18 patients (27.7%) experienced 21 arrhythmic events (AEs). None of the patients died during follow-up. Bradyarrhythmias were the most common finding (47.6%), followed by atrial tachyarrhythmias (38.1%). Only 3 patients presented with ventricular arrhythmias. AEs were considered incidental in 12 patients (66.7%). In 11 patients (61.1%), AEs led to specific changes in treatment. CONCLUSION: The use of ILR after a negative EPS in BrS is a safe strategy that reflected the high negative predictive value of EPS for ventricular arrhythmia in this syndrome. In addition, it allowed the detection of AEs in a significant proportion of patients, with therapeutic implications in most of them.

3.
Pacing Clin Electrophysiol ; 47(1): 149-155, 2024 01.
Article in English | MEDLINE | ID: mdl-38055612

ABSTRACT

BACKGROUND: Conventional right ventricle (RV) pacemaker stimulation has been associated with worse clinical outcomes in patients with cardiac amyloidosis (CA). Left bundle branch area pacing (LABPP) has been suggested as a promising alternative. We sought to assess the safety, feasibility, and outcomes of LABPP in patients with CA. METHODS: We retrospectively analyzed echocardiography and pacing parameters and clinical outcomes in 23 consecutive patients with CA and LBBAP implanted from June 2020 to October 2022. RESULTS: LBBAP was successfully performed in 22 over 23 patients (19 male, 78.6 ± 11.7 years, 20 ATTR, mean LVEF 45.5 ± 16.2%). After the procedure, 9 patients showed Qr pattern and 11 a qR pattern in V1 on ECG. Average procedure time was 67 ± 28 min. After 7.7 ± 5.2 months follow-up, no procedure-related complications had occurred. Although, a significant reduction in QRS width (p = .001) was achieved, we did not observe significant changes in LVEF and Nt ProBNP at 6 months of follow-up. Pacing parameters were stable during follow-up: LBB capture threshold and R wave amplitude were 1.0 ±  0.5 V and 10.6 ± 6.0 mV versus 0.8 ±  0.1 V, p = .21 and 10.6 ± 5.1 mV (p = .985) at follow up. CONCLUSION: LBBAP is safe and feasible pacing technique for patients with CA. LBBAP is associated with significant narrowing of QRSd without worsening in LVEF and Nt-proBNP.


Subject(s)
Amyloidosis , Ventricular Septum , Humans , Male , Feasibility Studies , Retrospective Studies , Amyloidosis/therapy , Heart Ventricles , Electrocardiography , Cardiac Pacing, Artificial , Bundle of His , Treatment Outcome
4.
Pacing Clin Electrophysiol ; 46(10): 1278-1286, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37695204

ABSTRACT

BACKGROUND: Embolic cerebrovascular events that remain of unknown etiology after a thorough diagnostic evaluation, are known as Embolic Strokes of Undetermined Source (ESUS). Subclinical atrial fibrillation (AF) represents a significant underlying cause of ESUS. Our aims were to examine the overall diagnostic yield of a prolonged cardiac monitoring wearable system (PCMw) after an ESUS to detect AF and factors associated with it, including the time frame from the ESUS event to PCMw initiation. Additionally, to evaluate the frequency of unexpected arrhythmic events (UAE) and their prognostic implications. METHODS: We retrospectively analyzed 200 ECG recordings (3-leads, 30 days duration) by means of a PCMw in patients with an ESUS to detect AF lasting longer than 30 s, between 2017 and 2021. UAE were defined as arrhythmia events that were not correlated to the main reason of prolonged cardiac monitoring. RESULTS: AF was detected in 21 patients (10.5%). Patients with AF had more left atrial enlargement (OR = 4.22 [1.59-6.85]; p = .01) and atrial arrythmias in the initial 24-h Holter during hospitalization (OR = 5.73 [2.03-16.49]; p = .001). The detection of AF was significatively higher if the PCMw was worn within the first 30 days after the ESUS compared to beyond 30 days (17% vs. 10.3%; p = .002). Fifty three patients (26.5%) had UAE during PCMw. In six of them these findings led to targeted treatment. CONCLUSION: PCMw represents a feasible non-invasive device that could reliably detect subclinical AF episodes after an ESUS. Diagnostic yield was significatively higher when used within the first 30 days after the event, especially in selected patients. UAE were common, but did not impact prognosis.

5.
Pacing Clin Electrophysiol ; 46(7): 598-606, 2023 07.
Article in English | MEDLINE | ID: mdl-37310031

ABSTRACT

BACKGROUND AND OBJECTIVES: The common practice after atrial fibrillation ablation is to admit patients for an overnight stay. The aim of this study was to compare a strategy of vascular suture mediated closure system utilization and early discharge (strategy A) compared to traditional closure and overnight hospitalization (strategy B) regarding feasibility, safety, quality of life and health care cost effectiveness. METHODS AND RESULTS: Hundred patients were randomized to compare both strategies. No clinical differences were reported except diabetes mellitus. Six patients (6%) had and emergency visit or were admitted in the first 30 days after procedure. Three occurred in strategy A versus three in strategy B (p = 1) (p < .005 for non-inferiority). Forty out of 50 patients (80%) were safely discharged in a time frame of 3 h and 42 patients (84%) were discharged in the same day of the procedure in strategy A. Time to discharge was shorter in strategy A compared to strategy B. (5.89 ± 7.47 h vs. 27.09 ± 2.29 p < .005). No differences were obtained in quality-of-life outcomes. Mean (95% CI) euros cost saving per patient in strategy A was 379.16 ± 93.55 p < .001. Ten acute complications (10% patients CI 95% 4.02%-15.98%) were reported during the trial. Seven (14% CI 95% 4.04%-23.96%) occurred in strategy A patients versus 3 (6% CI 95% 0.8%-12.8%) in strategy B. (p = .182) CONCLUSION: A strategy of vascular suture mediated closure system utilization and early discharge was feasible, reduced time to discharge, saved costs and was not associated with more complications or admissions/emergency visits in a 30-day time frame after procedure compared to a strategy of regular admission and discharge after overnight stay. There were no differences regarding quality-of-life parameters between both strategies.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Patient Discharge , Quality of Life , Hospitalization , Punctures , Treatment Outcome
6.
J Electrocardiol ; 74: 26-31, 2022.
Article in English | MEDLINE | ID: mdl-35917620

ABSTRACT

BACKGROUND: Adequate measurement of the QT interval is of clinical importance in order to identify patients at higher risk for ventricular arrhythmias. Previous studies have described different methods to estimate baseline QT in patients with left bundle branch block (LBBB). However, the evidence regarding the assessment of the QT in patients with right bundle branch block (RBBB) is scarce. AIM: To analyze the feasibility and reliability of the different formulae described for LBBB in the estimation of the baseline QT in the presence of RBBB. METHODS: We performed an observational study including patients who underwent electrophysiology study and/or ablation. Two types of RBBB were considered: 1) pacing-induced and 2) transient true RBBB. QRS, JT and QT intervals were measured during baseline and RBBB. Estimated QTc was calculated using LBBB formulae: Bogossian, Rautaharju, Tabatabaei, Tang-Rabkin, Yankelson, Wang. Linear correlation and intraclass correlation coefficients (ICC) were used to assess the reliability of these formulae for the estimation of baseline QTc. RESULTS: We finally included a total of 100 patients. Correlations between baseline and estimated QTc were strong (R > 0.7) for all the formulae except for Tabatabaei. Yankelson and Wang showed the highest reliability (ICC = 0.775 and 0.727, respectively). Yankelson appeared to be the most accurate formula, with a mean estimated QTc closest to baseline values. CONCLUSION: Previously described formulae for LBBB exhibited marked differences regarding reliability in the estimation of the QTc interval in the presence of RBBB. According to our results, Yankelson showed the most consistent and accurate agreement in this setting.


Subject(s)
Bundle-Branch Block , Electrocardiography , Humans , Bundle-Branch Block/diagnosis , Reproducibility of Results
7.
Pacing Clin Electrophysiol ; 45(7): 896-899, 2022 07.
Article in English | MEDLINE | ID: mdl-35191070

ABSTRACT

We present the case of a 75-year-old woman with severe aortic stenosis and moderate left ventricular dysfunction, who underwent elective transcatheter aortic valve replacement. After the procedure, the patient developed a left bundle branch block and a long PR interval. For this reason, a dual chamber pacemaker with pacing in the left bundle branch area was implanted. On device interrogation, we confirmed the presence of functional atrial undersensing causing loss of ventricular electric resynchronization. This case highlights the importance of recognizing this problem and, by means of device reprogramming and pharmacological intervention, suggests a stepwise approach to solve it.


Subject(s)
Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Aged , Arrhythmias, Cardiac , Bundle-Branch Block/therapy , Cardiac Pacing, Artificial , Electrocardiography , Female , Heart Conduction System , Humans , Treatment Outcome
8.
Int J Cardiol ; 352: 125-130, 2022 Apr 01.
Article in English | MEDLINE | ID: mdl-35092759

ABSTRACT

BACKGROUND: Increased collagen cross-linking (CCL) has been described in hypertensive cardiomyopathy by means of reduced serum ratio of serum carboxyterminal telopeptide of collagen type I (CITP) to matrix metalloproteinase-1 (MMP1). Previous studies have demonstrated the existence of primary impaired diastole in patients with Marfan syndrome (MFS), but little is known about the pathophysiology of this condition. METHODS: 60 MFS patients (without previous cardiovascular surgery or significant valvular regurgitation) and 24 healthy controls (age and sex-matched) were enrolled. All participants underwent a comprehensive transthoracic echocardiographic study, including left atrial and left ventricular speckle-tracking strain analysis. CITP and MMP1 were measured in peripheral blood. RESULTS: All participants had normal diastolic function according to guidelines. Peak left atrial strain in the reservoir phase (LASr) was significantly reduced in the MFS cohort compared to controls (32.2 ± 9.4 vs 43.9 ± 7.0%; p < 0.001). Serum CITP and CITP:MMP1 ratio were lower among MFS patients, showing significant correlations with LASr (R = 0.311; p = 0.020 and R = 0.437; p = 0.001, respectively). The MFS cohort was divided into quartiles of LASr. MFS patients in the lowest quartile of LASr (<26%) had significantly lower values of CITP:MMP1 ratio compared to the other quartiles. CONCLUSIONS: The analysis of serum biomarkers revealed the presence of increased CCL in association with reduced LASr in the MFS cohort. Our results suggest that excessive CCL may play a role in the development of primary myocardial impairment in these patients. Future studies are needed to confirm our findings and evaluate the prognostic role of CCL markers in the MFS population.


Subject(s)
Marfan Syndrome , Biomarkers , Collagen Type I , Diastole , Female , Humans , Male , Marfan Syndrome/complications , Marfan Syndrome/physiopathology , Myocardium
9.
J Interv Card Electrophysiol ; 63(1): 165-174, 2022 Jan.
Article in English | MEDLINE | ID: mdl-33594661

ABSTRACT

PURPOSE: Implantable cardiac defibrillator (ICD) is the only definitive therapy for prevention of sudden cardiac death in hypertrophic cardiomyopathy (HCM). Conventional transvenous ICDs can provide cardiac pacing unlike new subcutaneous ICD, but the usefulness of cardiac pacing in HCM patients is not well defined. We sought to assess the usefulness of ICD pacing in HCM. METHODS: We retrospectively analyzed 93 HCM patients who had undergone ICD implantation at our center. Usefulness of pacing was defined as follows: 1) need of pacing due to bradycardia or AV conduction disturbances, 2) improvement of LV outflow tract obstruction by sequential AV pacing, 3) need for CRT pacing, or 4) successful antitachycardia pacing without a subsequent shock. Independent predictors of useful pacing were investigated by multivariable analysis. RESULTS: During a mean follow-up of 91.3 ± 5.5 months, 43 patients (46.2%) reached the composite endpoint. Independent predictors of pacing usefulness were older age (HR 1.36; 95%CI: 1.088-1.709; p=0.007) and NYHA functional class ≥ II (HR 2.15; 95%CI: 1.083-4.301; p=0.029). Twenty-eight (30.1%) patients had appropriate ICD interventions, triggered by a monomorphic ventricular tachycardia (MVT) in 22 of them (78.5%). In 17 individuals with MVT (77%), antitachycardia pacing successfully treated MVT. CONCLUSIONS: In our HCM series of patients with ICD, 46% of individuals benefitted from cardiac pacing. MVT were documented in nearly 80% of the patients with ventricular arrhythmias and antitachycardia pacing successfully treated them in 77% of cases.


Subject(s)
Cardiomyopathy, Hypertrophic , Defibrillators, Implantable , Tachycardia, Ventricular , Aged , Arrhythmias, Cardiac , Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/therapy , Death, Sudden, Cardiac/prevention & control , Humans , Retrospective Studies , Tachycardia, Ventricular/therapy
11.
J Arrhythm ; 37(3): 690-692, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34141023

ABSTRACT

Sudden cardiac arrest (SCA) is an uncommon but devastating event among young adults. While inherited cardiomyopathies and channelopathies represent an important proportion of sudden deaths, coronary artery disease remains a significant contributor in this age group. ECG findings are essential to guide the first steps of diagnostic work-up of SCA, but sometimes can overlap between different etiologies. In this article we present a 16-year-old female who experienced SCA during vigorous swimming whose ECG was compatible with long QT syndrome. However, evaluation of the coronary anatomy provided the diagnosis of Kawasaki disease.

12.
Nat Commun ; 12(1): 2628, 2021 05 11.
Article in English | MEDLINE | ID: mdl-33976159

ABSTRACT

Thoracic aortic aneurysm, as occurs in Marfan syndrome, is generally asymptomatic until dissection or rupture, requiring surgical intervention as the only available treatment. Here, we show that nitric oxide (NO) signaling dysregulates actin cytoskeleton dynamics in Marfan Syndrome smooth muscle cells and that NO-donors induce Marfan-like aortopathy in wild-type mice, indicating that a marked increase in NO suffices to induce aortopathy. Levels of nitrated proteins are higher in plasma from Marfan patients and mice and in aortic tissue from Marfan mice than in control samples, indicating elevated circulating and tissue NO. Soluble guanylate cyclase and cGMP-dependent protein kinase are both activated in Marfan patients and mice and in wild-type mice treated with NO-donors, as shown by increased plasma cGMP and pVASP-S239 staining in aortic tissue. Marfan aortopathy in mice is reverted by pharmacological inhibition of soluble guanylate cyclase and cGMP-dependent protein kinase and lentiviral-mediated Prkg1 silencing. These findings identify potential biomarkers for monitoring Marfan Syndrome in patients and urge evaluation of cGMP-dependent protein kinase and soluble guanylate cyclase as therapeutic targets.


Subject(s)
Aortic Aneurysm, Thoracic/pathology , Cyclic GMP-Dependent Protein Kinase Type I/metabolism , Marfan Syndrome/complications , Soluble Guanylyl Cyclase/metabolism , Animals , Aorta/cytology , Aorta/diagnostic imaging , Aorta/drug effects , Aorta/pathology , Aortic Aneurysm, Thoracic/diagnosis , Aortic Aneurysm, Thoracic/etiology , Aortic Aneurysm, Thoracic/prevention & control , Biomarkers/blood , Biomarkers/metabolism , Carbazoles/administration & dosage , Cyclic GMP/blood , Cyclic GMP/metabolism , Disease Models, Animal , Female , Fibrillin-1/genetics , Gene Knockdown Techniques , Humans , Male , Marfan Syndrome/blood , Marfan Syndrome/genetics , Marfan Syndrome/pathology , Mice , Muscle, Smooth, Vascular/cytology , Mutation , Myocytes, Smooth Muscle , Nitric Oxide/metabolism , Nitric Oxide Donors/administration & dosage , Primary Cell Culture , Soluble Guanylyl Cyclase/antagonists & inhibitors , Ultrasonography
13.
Int J Cardiovasc Imaging ; 37(9): 2735-2745, 2021 Sep.
Article in English | MEDLINE | ID: mdl-33871735

ABSTRACT

Previous studies using conventional echocardiographic measurements have reported subclinical left ventricular (LV) diastolic abnormalities in patients with Marfan syndrome (MFS). Left atrial (LA) strain allows an accurate categorization of LV diastolic dysfunction. We aimed to characterize LV myocardial performance in a cohort of MFS patients using STE-derived measurements (LV and LA strain) along with conventional echocardiographic parameters. We studied 127 adult patients with MFS (no prior cardiac surgery or significant valvular regurgitation) and 38 healthy controls. We performed detailed echocardiograms and selected left atrial reservoir strain (LASr) as a surrogate of impaired relaxation. Additionally, we searched for possible determinants of LASr in patients with MFS, with a special focus on the elastic properties of the aorta. In spite of lower E-wave, septal and lateral e' velocities and average E/e' ratio in MFS patients, all participants had normal diastolic function according to current guidelines. MFS patients exhibited reduced LV global longitudinal strain (19.3 ± 2.6 vs 21.6 ± 2.1%, p < 0.001) and reduced LASr (32.9 ± 8.5 vs 43.3 ± 7.8%, p < 0.001) compared to controls. In the MFS cohort, we found weak significant (p < 0.05) correlations between LASr and certain parameters: E/A ratio (R = 0.258), E wave (R = 0.226), aortic distensibility (R = 0.222), stiffness index (R = - 0.216), LV ejection fraction (R = 0.214), lateral e' (R = 0.210), LV end-systolic volume index (R = - 0.210), LV global longitudinal strain (R = 0.201), septal e' (R = 0.185). After multivariate analysis, only LV end-systolic volume index and E/A ratio maintained a weak independent association with LASr (R = - 0.220; p = 0.017 and R = 0.199; p = 0.046, respectively). In conclusion, LASr is reduced in patients with MFS, which may represent an early stage of LV diastolic dysfunction. LASr is not determined by the elastic properties of the aorta, suggesting that impaired myocardial relaxation is a primary condition in MFS.


Subject(s)
Marfan Syndrome , Ventricular Dysfunction, Left , Diastole , Humans , Marfan Syndrome/diagnosis , Marfan Syndrome/diagnostic imaging , Predictive Value of Tests , Stroke Volume , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/etiology , Ventricular Function, Left
14.
Int J Cardiol ; 333: 233-238, 2021 06 15.
Article in English | MEDLINE | ID: mdl-33727123

ABSTRACT

BACKGROUND: Current evidence suggests that Brugada syndrome (BrS), far from being a purely electrical condition, is associated with subtle mechanical abnormalities primarily affecting the right ventricle (RV). We aimed to characterize RV function in BrS and investigate the echocardiographic profile of patients with arrhythmic events, with a special focus on parameters of RV dyssynchrony using speckle-tracking echocardiography (STE). METHODS: An echocardiogram was performed in 71 BrS patients and 25 healthy controls. STE was performed to assess regional and global RV mechanics, including RV outflow tract shortening (RVOTS). RVOT contraction time was considered to calculate the modified RV mechanical dispersion (RVMDm). Arrhythmic events were prospectively evaluated in the BrS cohort. RESULTS: Compared to controls, BrS patients showed subtle contractile abnormalities, including impaired RV longitudinal strain, higher RV index of myocardial performance (RIMP) and lower RVOTS. BrS patients also exhibited a greater contraction delay between the lateral and the septal aspect of the RV. After a median follow-up of 7.3 year (IQR 5.2-10.8), 6 patients presented malignant arrhythmic events. RIMP >0.50, RVOTS <16.2% and RVMDm > 42 ms showed high sensitivity for the identification of BrS patients with arrhythmic events during follow-up. CONCLUSIONS: Subtle RV mechanical abnormalities were present in BrS patients. RIMP and RVOTS, a novel STE-derived parameter, were found to be sensitive markers of arrhythmic events. Adding the RVOT contraction time to the analysis of RVMD may help identify patients at higher risk, reflecting the importance of the RVOT mechanical substrate in the assessment of the arrhythmic risk in BrS.


Subject(s)
Brugada Syndrome , Ventricular Dysfunction, Right , Brugada Syndrome/diagnostic imaging , Echocardiography , Electrocardiography , Heart Ventricles/diagnostic imaging , Humans , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Function, Right
15.
Eur Heart J Cardiovasc Imaging ; 23(1): 61-70, 2021 12 18.
Article in English | MEDLINE | ID: mdl-33496314

ABSTRACT

AIMS: The aim of this study is to investigate determinants of left atrial (LA) reservoir and pump strain and if these parameters may serve as non-invasive markers of left ventricular (LV) filling pressure. METHODS AND RESULTS: In a multicentre study of 322 patients with cardiovascular disease of different aetiologies, LA strain and other echocardiographic parameters were compared with invasively measured LV filling pressure. The strongest determinants of LA reservoir and pump strain were LV global longitudinal strain (GLS) (r-values 0.64 and 0.51, respectively) and LV filling pressure (r-values -0.52 and -0.57, respectively). Left atrial volume was another independent, but weaker determinant of both LA strains. For both LA strains, association with LV filling pressure was strongest in patients with reduced LV ejection fraction. Left atrial reservoir strain <18% and LA pump strain <8% predicted elevated LV filling pressure better (P < 0.05) than LA volume and conventional Doppler parameters. Accuracy to identify elevated LV filling pressure was 75% for LA reservoir strain alone and 72% for pump strain alone. When combined with conventional parameters, accuracy was 82% for both LA strains. In patients with normal LV systolic function by GLS, LA pump strain >14% identified normal LV filling pressure with 92% accuracy. CONCLUSION: Left atrial reservoir and pump strain are determined predominantly by LV GLS and filling pressure. Accuracy of LA strains to identify elevated LV filling pressure was best in patients with reduced LV systolic function. High values of LA pump strain, however, identified normal LV filling pressure with good accuracy in patients with normal systolic function.


Subject(s)
Ventricular Dysfunction, Left , Ventricular Function, Left , Echocardiography , Heart Atria/diagnostic imaging , Humans , Stroke Volume , Systole , Ventricular Dysfunction, Left/diagnostic imaging
19.
Psychosom Med ; 82(8): 744-750, 2020 10.
Article in English | MEDLINE | ID: mdl-32833897

ABSTRACT

OBJECTIVE: Anxiety is often present among patients with atrial fibrillation (AF). This condition has been associated with greater symptom severity and worse quality of life in these patients. However, the influence of anxiety on the risk of AF recurrence is not well known. We aimed to define the level of anxiety in patients with persistent AF undergoing elective cardioversion (EC) and determine whether there is an association between anxiety and the risk of early AF recurrence after EC. METHODS: Anxiety was measured before EC using the State-Trait Anxiety Inventory. Early AF recurrence was assessed with a control electrocardiogram at 30-day follow-up. RESULTS: We included 107 patients undergoing effective EC. Early AF recurrence was diagnosed in 40 patients (37.4%). Compared with those who remained in sinus rhythm, individuals with early AF recurrence had significantly higher levels of trait anxiety (23.1 [10.4] versus 17.9 [9.5]; p = .013) and larger left atrial volume index (45.8 [12.3] versus 37.9 [13.3] ml/m; p = .004). Both variables remained independently associated with early AF recurrence after multivariate analysis. A predictive model including trait anxiety score >20 and left atrial volume index >41 ml/m showed acceptable accuracy for the diagnosis of early AF recurrence (area under the curve = 0.733; 95% confidence interval = 0.634-0.832; p < .001). CONCLUSIONS: Our study shows that trait anxiety is an independent risk factor for early AF recurrence after EC. Further studies are warranted to assess the beneficial role of anxiety-reducing strategies on the outcomes of patients with AF.


Subject(s)
Atrial Fibrillation , Anxiety , Electric Countershock , Humans , Quality of Life , Recurrence , Treatment Outcome