Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 73
Filter
1.
Curr Pediatr Rev ; 2024 Jun 14.
Article in English | MEDLINE | ID: mdl-38879764

ABSTRACT

The Prune-Belly (Eagle-Barrett) syndrome (PBS) is a congenital and genetically heterogeneous disease, more prevalent in males, defined by the clinical triad (1) deficiency of abdominal muscles, (2) bilateral cryptorchidism, and (3) urinary tract abnormalities. The abdomen of an infant with PBS has a typical appearance, similar to the aspect of a prune, which gives it its name. Although the etiology of this disorder is still unknown, numerous theories, mutations, and genetic disturbances have been proposed to explain the origin of PBS. Prognosis can differ a lot from one patient to another, since this condition has a wide spectrum of clinical presentation. Despite being a rare condition, the importance of PBS should not be underestimated, in the light of the potential of the disorder to lead to chronic kidney disease and other severe complications. In that regard, this review gathers the most up-to-date knowledge about the etiopathogenesis, clinical features, diagnosis, management and prognosis of PBS.

2.
ACS Appl Mater Interfaces ; 16(26): 34057-34068, 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38910292

ABSTRACT

The current longevity of dental resins intraorally is limited by susceptibility to acidic attacks from bacterial metabolic byproducts and vulnerability to enzymatic or hydrolytic degradation. Here, we demonstrate synthesizing an ionic liquid-based antibiofilm silane effective against Streptococcus mutans, a major caries pathogen. Furthermore, we incorporate this silane into dental resins, creating antibiofilm- and degradation-resistant materials applicable across resin types. FTIR, UV-vis, and NMR spectroscopy confirmed the synthesis of the expected ionic liquid-based silane. The characterization of SiO2 after the silanization indicated the presence of the silane and how it interacted with the oxide. All groups achieved a degree of conversion similar to that found for commercial resin composites immediately and after two months of storage in water. The minimum of 2.5 wt % of silane led to lower softening in solvent than the control group (GCTRL) (p < 0.05). While the flexural strength indicated a lower value from 1 wt % of silane compared to GCTRL (p < 0.05), the ultimate tensile strength did not indicate differences among groups (p > 0.05). There was no difference within groups between the immediate and long-term tests of flexural strength (p > 0.05) or ultimate tensile strength (p > 0.05). The addition of at least 5 wt % of silane reduced the viability of S. mutans compared to GCTRL (p < 0.05). The fluorescence microscopy analysis suggested that the higher the silane concentration, the higher the amount of bacteria with membrane defects. There was no difference among groups in the cytotoxicity test (p > 0.05). Therefore, the developed dental resins displayed biocompatibility, proper degree of conversion, improved resistance against softening in solvent, and stability after 6 months of storage in water. This material could be further developed to produce polymeric antimicrobial layers for different surfaces, supporting various potential avenues in developing novel biomaterials with enhanced therapeutic characteristics using ionic liquid-based materials.


Subject(s)
Ionic Liquids , Nanoparticles , Silanes , Silicon Dioxide , Streptococcus mutans , Silanes/chemistry , Silanes/pharmacology , Streptococcus mutans/drug effects , Silicon Dioxide/chemistry , Silicon Dioxide/pharmacology , Ionic Liquids/chemistry , Ionic Liquids/pharmacology , Nanoparticles/chemistry , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Animals , Composite Resins/chemistry , Composite Resins/pharmacology , Mice , Biofilms/drug effects , Tensile Strength
3.
Braz Oral Res ; 38: e001, 2024.
Article in English | MEDLINE | ID: mdl-38198301

ABSTRACT

The aim of this study was to evaluate the influence of adding quaternary ammonium methacrylates (QAMs) to experimental adhesives by assessing the degree of conversion (DC), cytotoxicity against keratinocytes and fibroblasts, and antibacterial activity against biofilm formation. Two QAMs were added to an experimental adhesive: dimethylaminododecyl methacrylate bromododecane (DMADDM) or dimethylaminododecyl methacrylate bromohexadecane (DMAHDM) at three concentrations each: 1, 2.5, and 5 wt.%. Experimental adhesive without QAMs (control group) and commercially available Transbond XT Primer (3M Unitek, Monrovia, California, USA) were used for comparisons. The adhesives were tested for DC, cytotoxicity against keratinocytes and fibroblasts, and antibacterial activity against biofilm formation. DC, cytotoxicity against fibroblasts, and antibacterial activity were analyzed using one-way ANOVA and Tukey's multiple comparisons. Cytotoxicity against keratinocytes was evaluated using the Kruskal Wallis and Dunn's post-hoc (α = 5%) tests. Transbond showed lower DC as compared to 5% DMAHDM, 1% DMADDM, and 5% DMADDM (p < 0.05). However, all groups presented proper DC when compared to commercial adhesives in the literature. In the evaluation of cytotoxicity against keratinocytes, Transbond induced higher viability than 2.5 wt.% groups (p < 0.05). Against fibroblasts, Transbond induced higher viability as compared to 5 wt.% groups (p < 0.05). DMAHDM at 5 wt.% reduced biofilm formation when compared to all the other groups (p < 0.05). Despite their cytotoxic effect against keratinocytes, gingival fibroblasts showed higher viability. DMAHDM at 5 wt.% decreased Streptococcus mutans viability. The incorporation of DMAHDM at 5 wt.% may be a strategy for reducing the development of white spot lesions.


Subject(s)
Anti-Bacterial Agents , Bisphenol A-Glycidyl Methacrylate , Hydrocarbons, Brominated , Methacrylates , Methylamines , Quaternary Ammonium Compounds , Methacrylates/pharmacology , Anti-Bacterial Agents/pharmacology
4.
ACS Appl Mater Interfaces ; 16(2): 2120-2139, 2024 Jan 17.
Article in English | MEDLINE | ID: mdl-38170561

ABSTRACT

The process of bonding to dentin is complex and dynamic, greatly impacting the longevity of dental restorations. The tooth/dental material interface is degraded by bacterial acids, matrix metalloproteinases (MMPs), and hydrolysis. As a result, bonded dental restorations face reduced longevity due to adhesive interfacial breakdown, leading to leakage, tooth pain, recurrent caries, and costly restoration replacements. To address this issue, we synthesized and characterized a multifunctional magnetic platform, CHX@SiQuac@Fe3O4@m-SiO2, to provide several beneficial functions. The platform comprises Fe3O4 microparticles and chlorhexidine (CHX) encapsulated within mesoporous silica, which was silanized by an antibacterial quaternary ammonium silane (SiQuac). This platform simultaneously targets bacterial inhibition, stability of the hybrid layer, and enhanced filler infiltration by magnetic motion. Comprehensive experiments include X-ray diffraction, FT-IR, VSM, EDS, N2 adsorption-desorption (BET), transmission electron microscopy, scanning electron microscopy, thermogravimetric analysis, and UV-vis spectroscopy. Then, CHX@SiQuac@Fe3O4@m-SiO2 was incorporated into an experimental adhesive resin for dental bonding restorations, followed by immediate and long-term antibacterial assessment, cytotoxicity evaluation, and mechanical and bonding performance. The results confirmed the multifunctional nature of CHX@SiQuac@Fe3O4@m-SiO2. This work outlined a roadmap for (1) designing and tuning an adhesive formulation containing the new platform CHX@SiQuac@Fe3O4@m-SiO2; (2) assessing microtensile bond strength to dentin using a clinically relevant model of simulated hydrostatic pulpal pressure; and (3) investigating the antibacterial outcome performance of the particles when embedded into the formulated adhesives over time. The results showed that at 4 wt % of CHX@SiQuac@Fe3O4@m-SiO2-doped adhesive under the guided magnetic field, the bond strength increased by 28%. CHX@SiQuac@Fe3O4@m-SiO2 enhanced dentin adhesion in the magnetic guide bonding process without altering adhesive properties or causing cytotoxicity. This finding presents a promising method for strengthening the tooth/dental material interface's stability and extending the bonded restorations' lifespan.


Subject(s)
Silanes , Silicon Dioxide , Spectroscopy, Fourier Transform Infrared , Surface Properties , Chlorhexidine/chemistry , Anti-Bacterial Agents/pharmacology , Dental Cements/pharmacology , Dental Materials , Magnetic Phenomena , Dentin , Materials Testing , Tensile Strength
5.
Braz. oral res. (Online) ; 38: e001, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1528143

ABSTRACT

Abstract The aim of this study was to evaluate the influence of adding quaternary ammonium methacrylates (QAMs) to experimental adhesives by assessing the degree of conversion (DC), cytotoxicity against keratinocytes and fibroblasts, and antibacterial activity against biofilm formation. Two QAMs were added to an experimental adhesive: dimethylaminododecyl methacrylate bromododecane (DMADDM) or dimethylaminododecyl methacrylate bromohexadecane (DMAHDM) at three concentrations each: 1, 2.5, and 5 wt.%. Experimental adhesive without QAMs (control group) and commercially available Transbond XT Primer (3M Unitek, Monrovia, California, USA) were used for comparisons. The adhesives were tested for DC, cytotoxicity against keratinocytes and fibroblasts, and antibacterial activity against biofilm formation. DC, cytotoxicity against fibroblasts, and antibacterial activity were analyzed using one-way ANOVA and Tukey's multiple comparisons. Cytotoxicity against keratinocytes was evaluated using the Kruskal Wallis and Dunn's post-hoc (α = 5%) tests. Transbond showed lower DC as compared to 5% DMAHDM, 1% DMADDM, and 5% DMADDM (p < 0.05). However, all groups presented proper DC when compared to commercial adhesives in the literature. In the evaluation of cytotoxicity against keratinocytes, Transbond induced higher viability than 2.5 wt.% groups (p < 0.05). Against fibroblasts, Transbond induced higher viability as compared to 5 wt.% groups (p < 0.05). DMAHDM at 5 wt.% reduced biofilm formation when compared to all the other groups (p < 0.05). Despite their cytotoxic effect against keratinocytes, gingival fibroblasts showed higher viability. DMAHDM at 5 wt.% decreased Streptococcus mutans viability. The incorporation of DMAHDM at 5 wt.% may be a strategy for reducing the development of white spot lesions.

6.
Biomedicines ; 11(5)2023 Apr 23.
Article in English | MEDLINE | ID: mdl-37238927

ABSTRACT

Damage in the bonding interface is a significant factor that leads to premature failure of dental bonded restorations. The imperfectly bonded dentin-adhesive interface is susceptible to hydrolytic degradation and bacterial and enzyme attack, severely jeopardizing restorations' longevity. Developing caries around previously made restorations, also called "recurrent or secondary caries," is a significant health problem. The replacement of restorations is the most prevailing treatment in dental clinics, leading to the so-called "tooth death spiral". In other words, every time a restoration is replaced, more tooth tissue is removed, increasing the size of the restorations until the tooth is eventually lost. This process leads to high financial costs and detriment to patients' quality of life. Since the complexity of the oral cavity makes prevention a challenging task, novel strategies in Dental Materials and Operative fields are required. This article briefly overviews the physiological dentin substrate, features of dentin bonding, challenges and clinical relevance. We discussed the anatomy of the dental bonding interface, aspects of the degradation at the resin-dentin interface, extrinsic and intrinsic factors affecting dental bonding longevity, perspectives on resin and collagen degradation and how these subjects are connected. In this narrative review, we also outlined the recent progress in overcoming dental bonding challenges through bioinspiration, nanotechnology and advanced techniques to reduce degradation and improve dental bonding longevity.

7.
Clin Oral Investig ; 27(6): 2465-2481, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37017759

ABSTRACT

OBJECTIVES: The aim of this review to overview three-dimensional (3D) printing technologies available for different dental disciplines, considering the applicability of such technologies and materials development. MATERIALS AND METHODS: Source Arksey and O'Malley's five stages framework using PubMed, EMBASE, and Scopus (Elsevier) databases managed this review. Papers focusing on 3D printing in dentistry and written in English were screened. Scientific productivity by the number of publications, areas of interest, and the focus of the investigations in each dental discipline were extracted. RESULTS: Nine hundred thirty-four studies using 3D printing in dentistry were assessed. Limited clinical trials were observed, especially in Restorative, endodontics, and pediatric dentistry. Laboratory or animal studies are not reliable for clinical success, suggesting that clinical trials are a good approach to validate the new methods' outcomes and ensure that the benefits outweigh the risk. The most common application for 3D printing technologies is to facilitate conventional dental procedures. CONCLUSIONS: The constantly improving quality of 3D printing applications has contributed to increasing the popularity of these technologies in dentistry; however, long-term clinical studies are necessary to assist in defining standards and endorsing the safe application of 3D printing in dental practice. CLINICAL RELEVANCE: The recent progress in 3D materials has improved dental practice capabilities over the last decade. Understanding the current status of 3D printing in dentistry is essential to facilitate translating its applications from laboratory to the clinical setting.


Subject(s)
Endodontics , Printing, Three-Dimensional , Humans , Pediatric Dentistry , Dental Care
8.
J Funct Biomater ; 14(2)2023 Feb 14.
Article in English | MEDLINE | ID: mdl-36826904

ABSTRACT

Augmenting the vascular supply to generate new tissues, a crucial aspect in regenerative medicine, has been challenging. Recently, our group showed that calcium phosphate can induce the formation of a functional neo-angiosome without the need for microsurgical arterial anastomosis. This was a preclinical proof of concept for biomaterial-induced luminal sprouting of large-diameter vessels. In this study, we investigated if sprouting was a general response to surgical injury or placement of an inorganic construct around the vessel. Cylindrical biocement scaffolds of differing chemistries were placed around the femoral vein. A contrast agent was used to visualize vessel ingrowth into the scaffolds. Cell populations in the scaffold were mapped using immunohistochemistry. Calcium phosphate scaffolds induced 2.7-3 times greater volume of blood vessels than calcium sulphate or magnesium phosphate scaffolds. Macrophage and vSMC populations were identified that changed spatially and temporally within the scaffold during implantation. NLRP3 inflammasome activation peaked at weeks 2 and 4 and then declined; however, IL-1ß expression was sustained over the course of the experiment. IL-8, a promoter of angiogenesis, was also detected, and together, these responses suggest a role of sterile inflammation. Unexpectedly, the effect was distinct from an injury response as a result of surgical placement and also was not simply a foreign body reaction as a result of placing a rigid bioceramic next to a vein, since, while the materials tested had similar microstructures, only the calcium phosphates tested elicited an angiogenic response. This finding then reveals a potential path towards a new strategy for creating better pro-regenerative biomaterials.

9.
J Funct Biomater ; 13(4)2022 Oct 17.
Article in English | MEDLINE | ID: mdl-36278659

ABSTRACT

Current dental adhesives lack antibacterial properties. This study aimed to explore the effect of incorporating benzyldimethyldodecyl ammonium chloride (BDMDAC) on the degree of conversion, contact angle, ultimate tensile strength (UTS), microtensile bond strength (µTBS), cytotoxicity, antibacterial and bonding performance after artificial aging. A dental adhesive was doped with BDMDAC in the concentration range of 1-5 wt.%. For antibacterial assays, the BDMDAC compound was subject to planktonic cells of Streptococcus mutans. Then, after incorporation into the dental adhesive, an S. mutans biofilm model was used to grow 48 h-mature biofilms. The biofilms grown over the formulated materials were assessed by colony-forming unit (CFU) counting assay and fluorescence microscopy staining. In addition, the cytotoxicity was evaluated. Samples were subjected to 10,000 thermal cycles for aging and evaluated by UTS, µTBS, and CFU. Incorporating BDMDAC did not increase the cytotoxicity or change the physical properties when the mass fraction of the BDMDAC was 1-5 wt.%. The UTS of BDMDAC-doped adhesives was not impaired immediately or over time. A significant bacterial reduction was obtained for the mass fraction of the BDMDAC greater than 3 wt.%. However, the BDMDAC-doped adhesives did not offer an antibacterial effect after artificial aging. The overall results indicate that the BDMDAC strategy has the potential to control of microbial growth of cariogenic planktonic cells and biofilms. However, other new technological approaches are needed to overcome the deleterious effect of BDMDAC release over time such as those based on the principle of drug delivery systems whereby the BDMDAC is transported on microparticles or core shells, providing tangible benefits to oral health over time.

10.
Int J Prosthodont ; 35(4): 460-468, 2022.
Article in English | MEDLINE | ID: mdl-36125870

ABSTRACT

PURPOSE: To evaluate the effect of different luting techniques on the shear bond strength (SBS) of ultra-translucent multi-layered zirconia (UTML) after 24 hours and 1 year of water storage and to analyze the influence of primers on the wettability of the UTML MTU-6 surface. MATERIALS AND METHODS: Four commercial resin cements were evaluated: Variolink Esthetic LC (Ivoclar Vivadent); RelyX Ultimate (3M); Estecem II (Tokuyama); and Panavia V5 (Kuraray Noritake). Panavia V5 was tested with and without Panavia V5 Tooth Primer (Kuraray Noritake). The SBS immediately after cement/primer application and after aging, scanning electron microscopy of the surfaces, and the contact angle of the primers on the UTML surfaces were analyzed. RESULTS: At 24 hours, Panavia V5 with Tooth Primer exhibited the highest SBS. After 1 year, the SBS of Variolink Esthetic LC and Panavia V5 with Tooth Primer decreased, and RelyX Ultimate increased. There was no statistical difference between RelyX Ultimate and Panavia V5 with Tooth Primer at 1 year. For all groups, the rate of adhesive failures increased after 1 year. The highest contact angle was observed on the control (no primer) group, and the lowest contact angles were obtained when the YSZ surface was treated with Scotchbond Universal and the combination of Clearfil Ceramic Primer Plus and Tooth Primer. CONCLUSION: Clinicians should prefer 10-MDP-based cementation systems that can be properly polymerized to achieve a stable long-term bond strength to YSZ restorations. Also, the use of ceramic primers improves the capability of the cement to establish an intimate contact with the intaglio of the restoration.


Subject(s)
Dental Bonding , Resin Cements , Dental Bonding/methods , Dental Cements/chemistry , Dental Materials , Resin Cements/chemistry , Water , Zirconium/chemistry
12.
Clin Oral Investig ; 26(4): 3627-3636, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35001214

ABSTRACT

OBJECTIVES: The objective of this study is to formulate experimental dental adhesives with different polyhexamethylene guanidine hydrochloride concentrations (PHMGH) and evaluate their physical, chemical, and biological properties. MATERIALS AND METHODS: The experimental adhesives were formulated with 0 (control, GCTRL), 0.5 (G0.5%), 1 (G1%), or 2 (G2%) wt.% into the adhesive. The adhesives were analyzed for degree of conversion (DC%), softening in solvent (ΔKHN%), ultimate tensile strength (UTS), microtensile bond strength (µTBS) immediately and after 1 year of aging, antibacterial activity, and cytotoxicity. RESULTS: There were no differences among groups for DC%, ΔKHN%, and UTS (p > 0.05%). There were no differences between each PHMGH-doped adhesive compared to GCTRL in the immediate µ-TBS (p > 0.05). Adhesives with at least 1 wt.% of PHMGH presented better stability of µ-TBS. PHMGH-doped adhesives showed improved longitudinal µ-TBS compared to GCTRL (p < 0.05). Lower Streptococcus mutans biofilm formation was observed for PHMGH-doped adhesives (p < 0.05). There was lower viability of planktonic S. mutans in the media in contact with the samples when at least 1 wt.% of PHGMGH was incorporated (p < 0.05). The formulated adhesives showed no cytotoxicity against pulp cells (p > 0.05). CONCLUSIONS: The adhesive with 2 wt.% of PHMGH showed the highest antibacterial activity, without affecting the physicochemical properties and cytotoxicity, besides conferring stability for the dental adhesion. CLINICAL RELEVANCE: PHMGH, a positively charged polymer, conveyed antibacterial activity to dental adhesives. Furthermore, it did not negatively affect the essential physicochemical and biocompatibility properties of the adhesives. More importantly, the incorporation of PHMGH provided stability for the µ-TBS compared to the control group without this additive.


Subject(s)
Dental Bonding , Resin Cements , Adhesives , Dental Cements/pharmacology , Dentin , Dentin-Bonding Agents/pharmacology , Guanidine , Materials Testing , Polymers , Resin Cements/pharmacology , Tensile Strength
13.
Restor Dent Endod ; 46(4): e51, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34909415

ABSTRACT

OBJECTIVES: This study aimed to evaluate the effect of improper positioning single-peak and multi-peak lights on color change, microhardness of bottom and top, and surface topography of bulk fill and incremental composites after artificial aging for 1 year. MATERIALS AND METHODS: Bulk fill and incremental composites were cured using multi-peak and single-peak light-emitting diode (LED) following 4 clinical conditions: (1) optimal condition (no angulation or tip displacement), (2) tip-displacement (2 mm), (3) slight tip angulation (α = 20°) and (4) moderate tip angulation (α = 35°). After 1-year of water aging, the specimens were analyzed for color changes (ΔE), Vickers hardness, surface topography (Ra, Rt, and Rv), and scanning electron microscopy. RESULTS: For samples cured by single-peak LED, the improper positioning significantly increases the color change compared to the optimal position regardless of the type of composite (p < 0.001). For multi-peak LED, the type of resin composite and the curing condition displayed a significant effect on ΔE (p < 0.001). For both LEDs, the Vickers hardness and bottom/top ratio of Vickers hardness were affected by the type of composite and the curing condition (p < 0.01). CONCLUSIONS: The bulk fill composite presented greater resistance to wear, higher color stability, and better microhardness than the incremental composite when subjected to improper curing. The multi-peak LED improves curing under improper conditions compared to single-peak LED. Prevention of errors when curing composites requires the attention of all personnel involved in the patient's care once the clinical relevance of the appropriate polymerization reflects on reliable long-term outcomes.

14.
Saudi Dent J ; 33(7): 453-461, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34803286

ABSTRACT

AIM: This study aimed to investigate the dimensional stability of irreversible hydrocolloid and polyvinylsiloxane (P.V.S.) impressions after exposure to four commercial disinfectants using cone-beam computed tomography (CBCT). MATERIALS AND METHODS: Two different impression materials were tested: irreversible hydrocolloid and P.V.S. Four disinfection solutions were applied: BirexSE, Opti-Cide3, COEfect MinuteSpray, and CaviCide Spray. Distilled water was used as a control group. Each solution remained in contact with the impression for 5 min. Additional contact time of 5 min compromises time for scanning. The materials were evaluated for dimensional stability after the impression of a maxillary complete edentulous template via CBCT before and after being in contact with the disinfectant agents. Measurements were assessed on the digital models from A-B, B-C, and C-A points. Paired analyses (Wilcoxon Signed Rank test or paired Student's t-test) were used to analyze each measurement before and after the contact with the disinfectant agents. The variance for each measurement was also analyzed via a one-way analysis of variance or Kruskal-Wallis. RESULTS: Overall, there were no statistical differences among the points measurements in the irreversible hydrocolloid or P.V.S. between initial and final assessments (p > 0.05). The used disinfectant agents in this study did not influence each measurement's variation on irreversible hydrocolloid or P.V.S. (p > 0.05). All agents showed an effect on the dimensional stability of both impression materials. The differences in the three dimensions ranged between 0.34 and 1.54%. CONCLUSION: Within 10 min of removing the impression from the master cast, is study's findings indicated that the four commercially available disinfectants did not influence the dimensional stability of irreversible hydrocolloid or P.V.S. Further studies should be performed to elucidate the antimicrobial effect of these solutions applied as a spray on the surface of irreversible hydrocolloid and P.V.S. impressions.

15.
Bioengineering (Basel) ; 8(10)2021 Oct 19.
Article in English | MEDLINE | ID: mdl-34677219

ABSTRACT

Advances in nanotechnology have unlocked exclusive and relevant capabilities that are being applied to develop new dental restorative materials. Metal oxide nanoparticles and nanotubes perform functions relevant to a range of dental purposes beyond the traditional role of filler reinforcement-they can release ions from their inorganic compounds damaging oral pathogens, deliver calcium phosphate compounds, provide contrast during imaging, protect dental tissues during a bacterial acid attack, and improve the mineral content of the bonding interface. These capabilities make metal oxide nanoparticles and nanotubes useful for dental adhesives and composites, as these materials are the most used restorative materials in daily dental practice for tooth restorations. Secondary caries and material fractures have been recognized as the most common routes for the failure of composite restorations and bonding interface in the clinical setting. This review covers the significant capabilities of metal oxide nanoparticles and nanotubes incorporated into dental adhesives and composites, focusing on the novel benefits of antibacterial properties and how they relate to their translational applications in restorative dentistry. We pay close attention to how the development of contemporary antibacterial dental materials requires extensive interdisciplinary collaboration to accomplish particular and complex biological tasks to tackle secondary caries. We complement our discussion of dental adhesives and composites containing metal oxide nanoparticles and nanotubes with considerations needed for clinical application. We anticipate that readers will gain a complete picture of the expansive possibilities of using metal oxide nanoparticles and nanotubes to develop new dental materials and inspire further interdisciplinary development in this area.

16.
J Dent ; 114: 103818, 2021 11.
Article in English | MEDLINE | ID: mdl-34560223

ABSTRACT

OBJECTIVES: This study aimed to (1) formulate blend resins with 2.5 or 5 wt.% of the methacrylate monomer 1,3,5-triacryloylhexahydro-1,3,5-triazine (TAT), and (2) to evaluate the blend resins regarding the physicochemical and biological properties. METHODS: The base resin was formulated mixing 60 wt.% of bisphenol A glycol dimethacrylate and 40 wt.% of triethylene glycol dimethacrylate with photoinitiator/co/initiator system. TAT was added at 2.5 (G2.5%) or 5 (G5%) wt.%, and a group without TAT was used as control (Gctrl). The resins were analyzed for degree of conversion (DC), Knoop hardness (KHN), softening in solvent (ΔKHN), ultimate tensile strength (UTS), contact angle, surface free energy (SFE), antibacterial activity against Streptococcus mutans biofilm formation, and cytotoxicity against human keratinocytes. RESULTS: There was no difference for the DC (p = 0.676). The addition of TAT at 5 wt.% induced higher KHN (p<0.001), higher resistance against softening in solvent (p<0.001), and higher UTS (p = 0.04). There were no statistically significant differences for contact angle with water (p = 0.106), α-bromonaphtalene (p = 0.454), and SFE (p = 0.172). The higher the TAT concentration, the higher the antibacterial activity (p<0.001). G2.5% showed no cytotoxicity compared to Gctrl (p>0.05), and G5% induced lower cell viability (p<0.05). CONCLUSIONS: The addition of 2.5 wt.% of TAT is suitable for conveying antibacterial activity for dental resins without changing the physicochemical properties or impairing the cytotoxic effect. CLINICAL RELEVANCE: Methacrylate monomers that decrease bacterial viability and copolymerize with the resin matrix are exciting approaches to developing therapeutic materials. TAT showed promising properties to may hamper and prevent carious lesions when incorporated into dental materials. Further evaluations with higher cariogenic challenges will be carried to analyze the formulated materials.


Subject(s)
Methacrylates , Triazines , Anti-Bacterial Agents/pharmacology , Composite Resins/toxicity , Humans , Materials Testing , Resins, Synthetic/toxicity , Streptococcus mutans , Triazines/pharmacology
17.
J Adv Prosthodont ; 13(4): 237-245, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34504675

ABSTRACT

PURPOSE: This study aimed to compare the microshear bond strength (µSBS) of dual-cure resin cement in CAD-CAM zirconia after different cleaning techniques. MATERIALS AND METHODS: Fifty discs of zirconia-based ceramic from Ivoclar Vivadent were embedded in acrylic resin. The discs were divided into five groups according to the cleaning methods used: Group 1: drying with spraying + sandblasting with Al2O3; Group 2: washed with water and dried with spraying + sandblasting with Al2O3; Group 3: washed with distilled water and dried with spraying + sandblasting with Al2O3 + zirconium oxide (Ivoclean); Group 4: washed with distilled water and dried with spraying + sandblasting with Al2O3 + potassium hydroxide (Zirclean); and Group 5: washed with distilled water and dried with spraying + sandblasting with Al2O3 + 1% NaClO. All of the groups were contaminated with artificial saliva for 1 minute and then cleaned. Statistical analyses were performed using ANOVA and Tukey's tests. RESULTS: There were statistically significant differences among all groups for µSBS (P < .05). The group treated with zirconium oxide (Group 3) showed the highest µSBS (18.75 ± 0.23 MPa). CONCLUSION: When applied to zirconia, the cleaning methods affected the bonding with resin cement differently.

18.
Dent J (Basel) ; 9(8)2021 Jul 30.
Article in English | MEDLINE | ID: mdl-34435995

ABSTRACT

How dentists cure a resin-based material has deleterious effects on the material's properties and its interaction with surrounding dental tissues. Biofilm accumulation has been implicated in the pathogenesis of carious lesions around dental restorations, with its composition manifesting expressed dysbiosis in patients suffering from dental caries. To evaluate the influence of varying radiant exposure on the degree of conversion (DC%), Streptococcus mutans biofilm growth, and surface roughness of bulk-fill composites under different light-curing conditions. Two light-curing units (LCU) at 600 and 1000 mW/cm2 were used to simulate curing conditions with different angulations (∢20° and ∢35°) or 2 mm-distance displacements of the LCU tip. The radiant exposure (RE) was assessed, and the composites were analyzed for DC%. Biofilm formation was induced over the bulk-fill composites and analyzed via colony-forming units counting and scanning electron microscopy (SEM). The surface roughness was analyzed via a profilometer and SEM after biofilm formation. Curing conditions with different angulation or displacement decreased RE compared to the "optimal condition". The moderately (∢35°) angulated LCU tip and low (600 mW/cm2) radiant emittance significantly reduced the DC% (p < 0.05). The difference in DC% between the top and bottom of the composites ranged from 8 to 11% for 600 mW/cm2 and 10 to 20% for 1000 mW/cm2. Greater S. mutans biofilm and surface changes were found in composites with non-optimal RE delivery (e.g., tip displacement and angulation) (p < 0.05). Inadequate polymerization of bulk-fill composites was associated with more biofilm accumulation and surface topography changes. Overall, non-optimally performed curing procedures reduced the amount of delivered RE, which led to low DC%, more biofilm formation, and higher surface roughness. The improper light-curing of bulk-fill composites compromises their physicochemical and biological properties, which could lead to inferior clinical performance and reduced restorative treatments' longevity.

19.
Acta Biomater ; 134: 337-347, 2021 10 15.
Article in English | MEDLINE | ID: mdl-34303014

ABSTRACT

The limited durability of dentin bonding harshly shortens the lifespan of resin composites restorations. The controlled, dynamic movement of materials through non-contacting forces provides exciting opportunities in adhesive dentistry. We, herein, describe comprehensive investigations of a new dental adhesive with superparamagnetic iron oxide nanoparticles (SPIONs) sensitive to magnetic fields for bonding optimization. This contribution outlines a roadmap of (1) designing and tuning of an adhesive formulation containing SPIONs to enhance penetrability into etched dentin guided by magnetic-field; (2) employing a clinically relevant model of simulated hydrostatic pulpal pressure on the microtensile bond to dentin; and (3) investigating a potential antibacterial effect of the formulated adhesives, and their biocompatibility. SPION-concentration-dependency chemical and mechanical behavior was shown via the degree of conversion, ultimate tensile strength, and micro shear bond strength to dentin. The effects of SPIONs carried on a dental adhesive on the bonding strength to dentin are studied in depth by combining experiments with in vitro simulated model. The results show that under the guided magnetic field, 0.07 wt.% of SPIONs-doped adhesive increased the bond strength that surpasses the reduction caused by hydrostatic pulpal pressure. Using a magnetic guide workflow during the bonding procedures, SPIONs-doped adhesives improved dentin's adhesion without changing adhesives' physicochemical properties. This outcome addresses the key challenge of poor resin infiltration of dentin's conventional total etching during the bonding procedure. The real-time magnetic motion of dental adhesives may open new paths to enhance resin-based restorations' longevity. STATEMENT OF SIGNIFICANCE: In this study, dental adhesives containing superparamagnetic iron oxide nanoparticles (SPIONs) were developed to enhance penetrability into dentin guided by a magnetic field. The adhesives were screened for physical, chemical, antibacterial properties, and cytotoxicity. For the first time, simulated pulpal pressure was used concurrently with the magnetic field to simulate a clinical setting. This approach showed that it is feasible to overcome pulpal pressure jeopardization on bond strength when SPIONs and a magnetic field are applied. The magnetic-responsive adhesives had great potential to improve bond strength, opening new paths to enhance resin-based restorations' longevity without affecting adhesives' biological properties. The use of magnetic-responsive particles and magnetically assisted motion is a promising strategy to improve the sealing ability of dental adhesives.


Subject(s)
Dentin-Bonding Agents , Resin Cements , Composite Resins , Dentin , Magnetic Iron Oxide Nanoparticles , Magnetic Phenomena , Materials Testing
20.
Int J Esthet Dent ; 16(2): 216-230, 2021 05 10.
Article in English | MEDLINE | ID: mdl-33969976

ABSTRACT

AIM: The altered size, shape or position of the teeth affect their proper alignment, the harmony of the smile, and the dentofacial composition. The aim of this article is to describe a minimally invasive approach to improve the esthetics of a patient through the golden proportion (GP) concept with the use of direct composite resin stratification. MATERIALS AND METHODS: A 26-year-old female complained about the appearance of her smile due to the existing spaces between her anterior teeth; her small, peg-shaped lateral incisors; the wear of her canines; and the color of her teeth. The clinical examination confirmed diastemas in the anterior teeth, peg-shaped maxillary lateral incisors, and incisal wear of the canines. Treatment with dental whitening followed by composite restorations was performed in line with the current conservative approach in dentistry. The patient was followed up for 18 months. CONCLUSION: The use of the additive technique with composite for the closure of diastemas under the GP concept illustrates an example of viable management to restore esthetic harmony through a minimally invasive approach, with reliability over time and the advantages of being less laborious, less time consuming, and less expensive than other approaches. The treatment plan was acceptable to the patient.


Subject(s)
Esthetics, Dental , Incisor , Adult , Female , Follow-Up Studies , Humans , Reproducibility of Results , Smiling
SELECTION OF CITATIONS
SEARCH DETAIL
...