1.
Proc Natl Acad Sci U S A ; 119(5)2022 02 01.
Article in English | MEDLINE | ID: mdl-35074874

ABSTRACT

For nearly 50 years, the vision of using single molecules in circuits has been seen as providing the ultimate miniaturization of electronic chips. An advanced example of such a molecular electronics chip is presented here, with the important distinction that the molecular circuit elements play the role of general-purpose single-molecule sensors. The device consists of a semiconductor chip with a scalable array architecture. Each array element contains a synthetic molecular wire assembled to span nanoelectrodes in a current monitoring circuit. A central conjugation site is used to attach a single probe molecule that defines the target of the sensor. The chip digitizes the resulting picoamp-scale current-versus-time readout from each sensor element of the array at a rate of 1,000 frames per second. This provides detailed electrical signatures of the single-molecule interactions between the probe and targets present in a solution-phase test sample. This platform is used to measure the interaction kinetics of single molecules, without the use of labels, in a massively parallel fashion. To demonstrate broad applicability, examples are shown for probe molecule binding, including DNA oligos, aptamers, antibodies, and antigens, and the activity of enzymes relevant to diagnostics and sequencing, including a CRISPR/Cas enzyme binding a target DNA, and a DNA polymerase enzyme incorporating nucleotides as it copies a DNA template. All of these applications are accomplished with high sensitivity and resolution, on a manufacturable, scalable, all-electronic semiconductor chip device, thereby bringing the power of modern chips to these diverse areas of biosensing.


Subject(s)
Biosensing Techniques/instrumentation , Electronics/instrumentation , Enzyme Assays/instrumentation , Oligonucleotide Array Sequence Analysis/instrumentation , DNA , Equipment Design/instrumentation , Kinetics , Lab-On-A-Chip Devices , Miniaturization/instrumentation , Nanotechnology/instrumentation , Semiconductors
2.
Sci Rep ; 7: 44208, 2017 03 10.
Article in English | MEDLINE | ID: mdl-28281646

ABSTRACT

Two kinds of humidity-induced, bendable smart clothing have been designed to reversibly adapt their thermal insulation functionality. The first design mimics the pores in human skin, in which pre-cut flaps open to produce pores in Nafion sheets when humidity increases, as might occur during human sweating thus permitting air flow and reducing both the humidity level and the apparent temperature. Like the smart human sweating pores, the flaps can close automatically after the perspiration to keep the wearer warm. The second design involves thickness adjustable clothes by inserting the bent polymer sheets between two fabrics. As the humidity increases, the sheets become thinner, thus reducing the gap between the two fabrics to reduce the thermal insulation. The insulation layer can recover its original thickness upon humidity reduction to restore its warmth-preservation function. Such humidity sensitive smart polymer materials can be utilized to adjust personal comfort, and be effective in reducing energy consumption for building heating or cooling with numerous smart design.


Subject(s)
Body Temperature Regulation , Clothing , Humidity , Humans
3.
Acta Biomater ; 10(5): 2296-303, 2014 May.
Article in English | MEDLINE | ID: mdl-24384124

ABSTRACT

Radial metallic nanopillar/nanowire structures can be created by a controlled radiofrequency (RF) plasma processing technique on the surface of certain alloy wires, including important biomedical alloys such as MP35N (Co-Ni-Cr-Mo alloy), platinum-iridium and stainless steel. In electrode applications such as pacemakers or neural stimulators, the increase in surface area in elongated MP35N nanopillars allows for decreased surface impedance and greater current density. However, the nanopillar height on MP35N alloy tends to be self-limiting at ∼1-3µm. The objective of this study was to further elongate the radial nanopillars so as to reduce electrode impedance for biomedical electrode applications. Intelligent experimental design allowed for efficient investigation of processing parameters, including plasma material, process duration, power, pressure and repetition. It was found that multi-step repeated processing in the parameter-controlled RF environment could increase nanopillar height to ∼10µm, a 400% improvement, while the RF plasma processing with identical total duration but in a single step did not lead to desired nanopillar elongation. Measurement of electrode impedance in phosphate-buffered saline solution showed an associated decrease to one-fifth of the surface impedance of unprocessed wire for signals below 100Hz. For the purposes of this study, MP35N and Pt-Ir wires were characterized and demonstrated augmented surface impedance properties which, in combination with superior cell integration, enhanced biomedical electrode performance.


Subject(s)
Biocompatible Materials/chemistry , Metals/chemistry , Nanowires/chemistry , Alloys/chemistry , Animals , Cattle , Electric Impedance , Electrodes , Endothelial Cells/cytology , Endothelial Cells/ultrastructure , Nanowires/ultrastructure , Plasma Gases/chemistry , Radio Waves , Time Factors