1.
Europace ; 26(7)2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38938169

ABSTRACT

AIMS: Subclinical atrial fibrillation (AF) is associated with increased risk of progression to clinical AF, stroke, and cardiovascular death. We hypothesized that in pacemaker patients requiring dual-chamber rate-adaptive (DDDR) pacing, closed loop stimulation (CLS) integrated into the circulatory control system through intra-cardiac impedance monitoring would reduce the occurrence of atrial high-rate episodes (AHREs) compared with conventional DDDR pacing. METHODS AND RESULTS: Patients with sinus node dysfunctions (SNDs) and an implanted pacemaker or defibrillator were randomly allocated to dual-chamber CLS (n = 612) or accelerometer-based DDDR pacing (n = 598) and followed for 3 years. The primary endpoint was time to the composite endpoint of the first AHRE lasting ≥6 min, stroke, or transient ischaemic attack (TIA). All AHREs were independently adjudicated using intra-cardiac electrograms. The incidence of the primary endpoint was lower in the CLS arm (50.6%) than in the DDDR arm (55.7%), primarily due to the reduction in AHREs lasting between 6 h and 7 days. Unadjusted site-stratified hazard ratio (HR) for CLS vs. DDDR was 0.84 [95% confidence interval (CI), 0.72-0.99; P = 0.035]. After adjusting for CHA2DS2-VASc score, the HR remained 0.84 (95% CI, 0.71-0.99; P = 0.033). In subgroup analyses of AHRE incidence, the incremental benefit of CLS was greatest in patients without atrioventricular block (HR, 0.77; P = 0.008) and in patients without AF history (HR, 0.73; P = 0.009). The contribution of stroke/TIA to the primary endpoint (1.3%) was low and not statistically different between study arms. CONCLUSION: Dual-chamber CLS in patients with SND is associated with a significantly lower AHRE incidence than conventional DDDR pacing.


Subject(s)
Atrial Fibrillation , Cardiac Pacing, Artificial , Heart Rate , Ischemic Attack, Transient , Pacemaker, Artificial , Sick Sinus Syndrome , Stroke , Humans , Female , Male , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Atrial Fibrillation/epidemiology , Aged , Sick Sinus Syndrome/therapy , Sick Sinus Syndrome/physiopathology , Cardiac Pacing, Artificial/methods , Ischemic Attack, Transient/prevention & control , Ischemic Attack, Transient/epidemiology , Middle Aged , Stroke/prevention & control , Stroke/epidemiology , Incidence , Treatment Outcome , Time Factors , Risk Factors , Defibrillators, Implantable , Electrophysiologic Techniques, Cardiac , Accelerometry , Aged, 80 and over
2.
Circ Arrhythm Electrophysiol ; 17(6): e012523, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38690665

ABSTRACT

BACKGROUND: In the PARTITA trial (Does Timing of Ventricular Tachycardia Ablation Affect Prognosis in Patients With an Implantable Cardioverter Defibrillator?), antitachycardia pacing (ATP) predicted the occurrence of implantable cardioverter defibrillator (ICD) shocks. Catheter ablation of ventricular tachycardia after the first shock reduced the risk of death or worsening heart failure. A threshold of ATPs that might warrant an ablation procedure before ICD shocks is unknown. Our aim was to identify a threshold of ATPs and clinical features that predict the occurrence of shocks and cardiovascular events. METHODS: We analyzed data from 517 patients in phase A of the PARTITA study. We used classification and regression tree analysis to develop and test a risk stratification model based on arrhythmia patterns and clinical data to predict ICD shocks. Secondary end points were worsening heart failure and cardiovascular hospitalization. RESULTS: Classification and regression tree classified patients into 6 leaves by increasing shock probability. Patients treated with ≥5 ATPs in 6 months (active arrhythmia pattern) had the highest risk of ICD shocks (93% and 86%, training and testing samples, respectively). Patients without ATPs had the lowest (1% and 2%). Other predictors included left ventricle ejection fraction<35%, age of <60 years, and obesity. Survival analysis revealed a higher risk of worsening heart failure (hazard ratio, 5.45 [95% CI, 1.62-18.4]; P=0.006) and cardiovascular hospitalization (hazard ratio, 7.29 [95% CI, 3.66-14.5]; P<0.001) for patients with an active arrhythmia pattern compared with those without ATPs. CONCLUSIONS: Patients with an active arrhythmia pattern (≥5 ATPs in 6 months) are associated with an increased risk of ICD shocks, as well as heart failure hospitalization and cardiovascular hospitalization. These data suggest that additional treatments may be helpful to this high-risk group as a preventive strategy to reduce the incidence of major events. Further prospective randomized trials are needed to confirm the benefits of early ventricular tachycardia ablation in this setting.


Subject(s)
Defibrillators, Implantable , Electric Countershock , Heart Failure , Tachycardia, Ventricular , Humans , Female , Male , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/therapy , Tachycardia, Ventricular/mortality , Middle Aged , Aged , Risk Factors , Risk Assessment , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Heart Failure/physiopathology , Heart Failure/therapy , Heart Failure/diagnosis , Heart Failure/mortality , Catheter Ablation/adverse effects , Time Factors , Treatment Outcome , Cardiac Pacing, Artificial/adverse effects
3.
Heart Rhythm ; 2024 Mar 16.
Article in English | MEDLINE | ID: mdl-38493989

ABSTRACT

BACKGROUND: Atrial high-rate episodes (AHREs) are frequent in patients with cardiac implantable electronic devices. A decrease in device-detected P-wave amplitude may be an indicator of periods of increased risk of AHRE. OBJECTIVE: The objective of this study was to assess the association between P-wave amplitude and AHRE incidence. METHODS: Remote monitoring data from 2579 patients with no history of atrial fibrillation (23% pacemakers and 77% implantable cardioverter-defibrillators, of which 40% provided cardiac resynchronization therapy) were used to calculate the mean P-wave amplitude during 1 month after implantation. The association with AHRE incidence according to 4 strata of daily burden duration (≥15 minutes, ≥6 hours, ≥24 hours, ≥7 days) was investigated by adjusting the hazard ratio with the CHA2DS2-VASc score. RESULTS: The adjusted hazard ratio for 1-mV lower mean P-wave amplitude during the first month increased from 1.10 (95% confidence interval [CI], 1.05-1.15; P < .001) to 1.18 (CI, 1.09-1.28; P < .001) with AHRE duration strata from ≥15 minutes to ≥7 days independent of the CHA2DS2-VASc score. Of 871 patients with AHREs, those with 1-month P-wave amplitude <2.45 mV had an adjusted hazard ratio of 1.51 (CI, 1.19-1.91; P = .001) for progression of AHREs from ≥15 minutes to ≥7 days compared with those with 1-month P-wave amplitude ≥2.45 mV. Device-detected P-wave amplitudes decreased linearly during the 1 year before the first AHRE by 7.3% (CI, 5.1%-9.5%; P < .001 vs patients without AHRE). CONCLUSION: Device-detected P-wave amplitudes <2.45 mV were associated with an increased risk of AHRE onset and progression to persistent forms of AHRE independent of the patient's risk profile.

4.
Europace ; 26(2)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38340330

ABSTRACT

AIMS: A dual-chamber pacemaker with closed-loop stimulation (CLS) mode is effective in reducing syncopal recurrences in patients with asystolic vasovagal syncope (VVS). In this study, we explored the haemodynamic and temporal relationship of CLS during a tilt-induced vasovagal reflex. METHODS AND RESULTS: Twenty patients underwent a tilt test under video recording 3.9 years after CLS pacemaker implantation. Three patients were excluded from the analysis because of no VVS induced by the tilt test (n = 1) and protocol violation (n = 2). In 14 of the remaining 17 patients, CLS pacing emerged during the pre-syncopal phase of circulatory instability when the mean intrinsic heart rate (HR) was 88 ± 12 b.p.m. and systolic blood pressure (SBP) was 108 ± 19 mmHg. The CLS pacing rate thereafter rapidly increased to 105 ± 14 b.p.m. within a median of 0.1 min [inter-quartile range (IQR), 0.1-0.7 min] when the SBP was 99 ± 21 mmHg. At the time of maximum vasovagal effect (syncope or pre-syncope), SBP was 63 ± 17 mmHg and the CLS rate was 95 ± 13 b.p.m. The onset of CLS pacing was 1.7 min (IQR, 1.5-3.4) before syncope or lowest SBP. The total duration of CLS pacing was 5.0 min (IQR, 3.3-8.3). Closed-loop stimulation pacing was not observed in three patients who had a similar SBP decrease from 142 ± 22 mmHg at baseline to 69 ± 4 mmHg at the time of maximum vasovagal effect, but there was no significant increase in HR (59 ± 1 b.p.m.). CONCLUSION: The reproducibility of a vasovagal reflex was high. High-rate CLS pacing was observed early during the pre-syncopal phase in most patients and persisted, although attenuated, at the time of maximum vasovagal effect. REGISTRATION: ClinicalTrials.gov identifier: NCT06038708.


Subject(s)
Pacemaker, Artificial , Syncope, Vasovagal , Humans , Cardiac Pacing, Artificial/methods , Hemodynamics , Pacemaker, Artificial/adverse effects , Reproducibility of Results , Syncope, Vasovagal/diagnosis , Syncope, Vasovagal/prevention & control , Tilt-Table Test/methods
5.
Europace ; 26(2)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38291778

ABSTRACT

AIMS: To predict worsening heart failure hospitalizations (WHFHs) in patients with implantable defibrillators and remote monitoring, the HeartInsight algorithm (Biotronik, Berlin, Germany) calculates a heart failure (HF) score combining seven physiologic parameters: 24 h heart rate (HR), nocturnal HR, HR variability, atrial tachyarrhythmia, ventricular extrasystoles, patient activity, and thoracic impedance. We compared temporal trends of the HF score and its components 12 weeks before a WHFH with 12-week trends in patients without WHFH, to assess whether trends indicate deteriorating HF regardless of alert status. METHODS AND RESULTS: Data from nine clinical trials were pooled, including 2050 patients with a defibrillator capable of atrial sensing, ejection fraction ≤ 35%, NYHA class II/III, no long-standing atrial fibrillation, and 369 WHFH from 259 patients. The mean HF score was higher in the WHFH group than in the no WHFH group (42.3 ± 26.1 vs. 30.7 ± 20.6, P < 0.001) already at the beginning of 12 weeks. The mean HF score further increased to 51.6 ± 26.8 until WHFH (+22% vs. no WHFH group, P = 0.003). As compared to the no WHFH group, the algorithm components either were already higher 12 weeks before WHFH (24 h HR, HR variability, thoracic impedance) or significantly increased until WHFH (nocturnal HR, atrial tachyarrhythmia, ventricular extrasystoles, patient activity). CONCLUSION: The HF score was significantly higher at, and further increased during 12 weeks before WHFH, as compared to the no WHFH group, with seven components showing different behaviour and contribution. Temporal trends of HF score may serve as a quantitative estimate of HF condition and evolution prior to WHFH.


Subject(s)
Defibrillators, Implantable , Heart Failure , Tachycardia, Ventricular , Humans , Hospitalization , Heart Failure/diagnosis , Heart Failure/therapy , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/therapy , Cardiac Complexes, Premature