Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 166
Filter
1.
Cureus ; 16(7): e65084, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39171054

ABSTRACT

The clotting pathway involves intrinsic and extrinsic pathways converging into a common pathway. These pathways require activated factors that sequentially convert prothrombin to thrombin, which then converts fibrinogen to fibrin, forming a stable clot. Clotting factor deficiency impairs this cascade leading to excessive bleeding or bruising due to insufficient clot formation. Here, we present the case of a 47-year-old female who initially complained of epigastric pain. By the third day of admission, she experienced four to five episodes of bleeding gums, resulting in a blood loss of approximately 300 mL. The patient exhibited abnormal prothrombin time (PT) and international normalized ratio (INR) values, leading to a diagnosis of Factor X (FX) deficiency upon further evaluation. This case report emphasizes the need to diagnose coagulopathies such as FX deficiency and how early diagnosis will help not only in patient care and management but also in screening family members who may be affected.

3.
Cureus ; 16(7): e63775, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39100036

ABSTRACT

Nonalcoholic fatty liver disease (NAFLD) and periodontitis share common risk factors such as obesity, insulin resistance (IR), and dyslipidemia, which contribute to systemic inflammation. It has been suggested that a bidirectional relationship exists between NAFLD and periodontitis, indicating that one condition may exacerbate the other. NAFLD is characterized by excessive fat deposition in the liver and is associated with low-grade chronic inflammation. There are several risk factors for the development of NAFLD, including gender, geriatric community, race, ethnicity, poor sleep quality and sleep deprivation, physical activity, nutritional status, dysbiosis gut microbiota, increased oxidative stress, overweight, obesity, higher body mass index (BMI), IR, type 2 diabetes mellitus (T2DM), metabolic syndrome (MetS), dyslipidemia (hypercholesterolemia), and sarcopenia (decreased skeletal muscle mass). This systemic inflammation can contribute to the progression of periodontitis by impairing immune responses and exacerbating the inflammatory processes in the periodontal tissues. Furthermore, individuals with NAFLD often exhibit altered lipid metabolism, which may affect oral microbiota composition, leading to dysbiosis and increased susceptibility to periodontal disease. Conversely, periodontitis has been linked to the progression of NAFLD through mechanisms involving systemic inflammation and oxidative stress. Chronic periodontal inflammation can release pro-inflammatory cytokines and bacterial toxins into the bloodstream, contributing to liver inflammation and exacerbating hepatic steatosis. Moreover, periodontitis-induced oxidative stress may promote hepatic lipid accumulation and IR, further aggravating NAFLD. The interplay between NAFLD and periodontitis underscores the importance of comprehensive management strategies targeting both conditions. Lifestyle modifications such as regular exercise, a healthy diet, and proper oral hygiene practices are crucial for preventing and managing these interconnected diseases. Additionally, interdisciplinary collaboration between hepatologists and periodontists is essential for optimizing patient care and improving outcomes in individuals with NAFLD and periodontitis.

4.
Article in English | MEDLINE | ID: mdl-39153133

ABSTRACT

BACKGROUND: There is a paucity of data comparing conduction system pacing (CSP) to biventricular pacing (BiVP) in patients with heart failure (HF) with mid-range left ventricular ejection fraction (LVEF). OBJECTIVE: Compare the clinical outcomes of patients with mid-range LVEF undergoing CSP versus BiVP. METHODS: Patients with mid-range LVEF (> 35 to 50%) undergoing CSP or BiVP were retrospectively identified. Lead performance, LVEF, HF hospitalization, and clinical composite outcome including upgrade to cardiac resynchronization therapy and mortality were compared. RESULTS: A total of 36 patients (20 BiVP, 16 CSP--14 His bundle pacing, 4 left bundle branch area pacing) were analyzed. The mean age was 73 ± 15, 44% were female, and the mean LVEF was 42 ± 5%. Procedural and fluoroscopy time was comparable between the two groups. QRS duration was significantly shorter for the CSP group compared to the BiVP group (P < 0.001). During a mean follow-up of 47 ± 36 months, no significant differences were found in thresholds or need for generator change due to early battery depletion. LVEF improved in both groups (41.5 ± 4.5% to 53.9 ± 10.9% BiVP, P < 0.001; 41.6 ± 5.3% to 52.5 ± 8.3% CSP, P < 0.001). There were no significant differences in HF hospitalizations (P = 0.71) or clinical composite outcomes (P = 0.07). CONCLUSION: Among patients with HF with moderately reduced ejection fraction, CSP appears associated with similar improvements in LVEF and had similar clinical outcomes as BiVP in mid-term follow-up.

5.
J Am Heart Assoc ; 13(15): e034500, 2024 Aug 06.
Article in English | MEDLINE | ID: mdl-39011955

ABSTRACT

BACKGROUND: Shock-reduction implantable cardioverter-defibrillator programming (SRP) was associated with fewer therapies and improved survival in randomized controlled trials, but real-world studies investigating SRP and associated outcomes are limited. METHODS AND RESULTS: The BIOTRONIK CERTITUDE registry was linked with the Medicare database. We included all patients with an implantable cardioverter-defibrillator implanted between August 22, 2012 and September 30, 2021 in the United States. SRP was defined as programming to either a therapy rate cutoff ≥188 beats per minute or number of intervals to detection ≥30/40 for treatment. Among 6781 patients (mean 74±9 years; 27% women), 3393 (50%) had SRP. Older age, secondary prevention indication, and device implantation in the southern or western United States were associated with lower use of SRP. The cumulative incidence rate of implantable cardioverter-defibrillator shocks was lower in the SRP group (5.1% shocks/patient year) compared with the non-SRP group (7.2% shocks/patient year) (adjusted hazard ratio [HR], 0.83 [95% CI, 0.73-0.96]; P=0.005). Over a median follow-up of 2.9 years, 739 deaths occurred in the SRP group and 822 deaths occurred in the non-SRP group (adjusted HR, 0.97 [95% CI, 0.88-1.07]; P=0.569). SRP was associated with a lower all-cause mortality among patients without ischemic heart disease compared with patients with ischemic heart disease (adjusted HR, 0.64 [95% CI, 0.48-0.87] versus adjusted HR, 1.02 [95% CI, 0.92-1.14]; Pinteraction=0.004). CONCLUSIONS: Adoption of SRP is low in real-world clinical practice. Age, clinical variables, and geographic factors are associated with use of SRP. In this study, SRP-associated decrease in mortality was limited to patients without ischemic heart disease.


Subject(s)
Death, Sudden, Cardiac , Defibrillators, Implantable , Electric Countershock , Registries , Humans , Female , Aged , Male , United States/epidemiology , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Electric Countershock/mortality , Aged, 80 and over , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/epidemiology , Secondary Prevention/methods , Risk Factors , Treatment Outcome , Medicare , Time Factors , Risk Assessment
6.
Article in English | MEDLINE | ID: mdl-39039649

ABSTRACT

INTRODUCTION: The impact of mRNA-based coronavirus disease-2019 (COVID-19) vaccines on atrial arrhythmias (AA) and ventricular arrhythmias incidence is unknown. METHODS: BIOTRONIK Home Monitoring data and Medicare Claims data were utilized to identify individuals implanted with a cardiac implantable electronic device (CIED) between 2010 and 2020 who received one or more doses of COVID-19 vaccine in 2021. The burden of AA (%) in the 3 months postvaccination was compared to those noted in the preceding 3 months using the Wilcoxon signed rank test. Sub-analyses comparing the effects of the influenza vaccine against the COVID-19 vaccine were also evaluated for individuals who received the influenza vaccine in 2020. A 1:1 propensity score match comparison between COVID-19 vaccine and non-vaccinated patients was also performed. RESULTS: First and second doses of the COVID-19 vaccine were administered to 7757 and 6579 individuals with a CIED (age 76.2 ± 9.0 years, 49% males), respectively. While a small but statistically significant increase in the burden of AA was noted in the 3 months postvaccination compared to the preceding 3 months after the first dose of the COVID-19 vaccine (0.43 ± 9.04%, p = .028) a similar rise in AA was found following the influenza vaccine and for matched patients who did not receive the COVID-19 vaccine. No significant difference in device therapies was seen pre- and postvaccination. CONCLUSIONS: Though we report a small but significant increase in the number of CIED-detected AAs following vaccination for COVID-19 over a 3-month window, we believe these results correlate more with time and the progressive nature of AF rather than the vaccine itself. While these data should not dissuade from the use of these vaccines, increased vigilance and prompt treatment of AF is required for high-risk groups, specifically males over 70 years of age, following vaccination.

7.
Heart Rhythm ; 2024 May 24.
Article in English | MEDLINE | ID: mdl-38797305

ABSTRACT

BACKGROUND: Despite effectiveness of the implantable cardioverter-defibrillator (ICD) in saving patients with life-threatening ventricular arrhythmias (VAs), the temporal occurrence of VA after ICD implantation is unpredictable. OBJECTIVE: The study aimed to apply machine learning (ML) to intracardiac electrograms (IEGMs) recorded by ICDs as a unique biomarker for predicting impending VAs. METHODS: The study included 13,516 patients who received Biotronik ICDs and enrolled in the CERTITUDE registry between January 1, 2010, and December 31, 2020. Database extraction included IEGMs from standard quarterly transmissions and VA event episodes. The processed IEGM data were pulled from device transmissions stored in a centralized Home Monitoring Service Center and reformatted into an analyzable format. Long-range (baseline or first scheduled remote recording), mid-range (scheduled remote recording every 90 days), or short-range predictions (IEGM within 5 seconds before the VA onset) were used to determine whether ML-processed IEGMs predicted impending VA events. Convolutional neural network classifiers using ResNet architecture were employed. RESULTS: Of 13,516 patients (male, 72%; age, 67.5 ± 11.9 years), 301,647 IEGM recordings were collected; 27,845 episodes of sustained ventricular tachycardia or ventricular fibrillation were observed in 4467 patients (33.0%). Neural networks based on convolutional neural networks using ResNet-like architectures on far-field IEGMs yielded an area under the curve of 0.83 with a 95% confidence interval of 0.79-0.87 in the short term, whereas the long-range and mid-range analyses had minimal predictive value for VA events. CONCLUSION: In this study, applying ML to ICD-acquired IEGMs predicted impending ventricular tachycardia or ventricular fibrillation events seconds before they occurred, whereas midterm to long-term predictions were not successful. This could have important implications for future device therapies.

8.
Europace ; 26(6)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38703372

ABSTRACT

AIMS: To characterize the diagnosis, frequency, and procedural implications of septal venous channel perforation during left bundle branch area pacing (LBBAP). METHODS AND RESULTS: All consecutive patients undergoing LBBAP over an 8-month period were prospectively studied. During lead placement, obligatory septal contrast injection was performed twice, at initiation (implant entry zone) and at completion (fixation zone). An intuitive fluoroscopic schema using orthogonal views (left anterior oblique/right anterior oblique) and familiar landmarks is described. Using this, we resolved zonal distribution (I-VI) of lead position on the ventricular septum and its angulation (post-fixation angle θ). Subjects with and without septal venous channel perforation were compared. Sixty-one patients {male 57.3%, median age [interquartile range (IQR)] 69.5 [62.5-74.5] years} were enrolled. Septal venous channel perforation was observed in eight (13.1%) patients [male 28.5%, median age (IQR) 64 (50-75) years]. They had higher frequency of (i) right-sided implant (25% vs. 1.9%, P = 0.04), (ii) fixation in zone III at the mid-superior septum (75% vs. 28.3%, P = 0.04), (iii) steeper angle of fixation-median θ (IQR) [19 (10-30)° vs. 5 (4-19)°, P = 0.01], and (iv) longer median penetrated-lead length (IQR) [13 (10-14.8) vs. 10 (8.5-12.5) mm, P = 0.03]. Coronary sinus drainage of contrast was noted in five (62.5%) patients. Abnormal impedance drops during implantation (12.5% vs. 5.7%, P = NS) were not significantly different. CONCLUSION: When evaluated systematically, septal venous channel perforation may be encountered commonly after LBBAP. The fiducial reference framework described using fluoroscopic imaging identified salient associated findings. This may be addressed with lead repositioning to a more inferior location and is not associated with adverse consequence acutely or in early follow-up.


Subject(s)
Cardiac Pacing, Artificial , Humans , Male , Female , Prospective Studies , Middle Aged , Aged , Cardiac Pacing, Artificial/methods , Ventricular Septum/diagnostic imaging , Heart Injuries/etiology , Heart Injuries/diagnostic imaging , Treatment Outcome , Risk Factors , Bundle of His/physiopathology , Heart Septum/diagnostic imaging , Contrast Media , Fluoroscopy , Bundle-Branch Block/physiopathology , Bundle-Branch Block/etiology
9.
J Am Chem Soc ; 146(19): 13377-13390, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38709577

ABSTRACT

Metal-organic frameworks (MOFs) offer an interesting opportunity for catalysis, particularly for metal-nitrogen-carbon (M-N-C) motifs by providing an organized porous structural pattern and well-defined active sites for the oxygen reduction reaction (ORR), a key need for hydrogen fuel cells and related sustainable energy technologies. In this work, we leverage electrochemical testing with computational models to study the electronic and structural properties in the MOF systems and their relationship to ORR activity and stability based on dual transitional metal centers. The MOFs consist of two M1 metals with amine nodes coordinated to a single M2 metal with a phthalocyanine linker, where M1/M2 = Co, Ni, or Cu. Co-based metal centers, in particular Ni-Co, demonstrate the highest overall activity of all nine tested MOFs. Computationally, we identify the dominance of Co sites, relative higher importance of the M2 site, and the role of layer M1 interactions on the ORR activity. Selectivity measurements indicate that M1 sites of MOFs, particularly Co, exhibit the lowest (<4%), and Ni demonstrates the highest (>46%) two-electron selectivity, in good agreement with computational studies. Direct in situ stability characterization, measuring dissolved metal ions, and calculations, using an alkaline stability metric, confirm that Co is the most stable metal in the MOF, while Cu exhibits notable instability at the M1. Overall, this study reveals how atomistic coupling of electronic and structural properties affects the ORR performance of dual site MOF catalysts and opens new avenues for the tunable design and future development of these systems for practical electrochemical applications.

10.
Eur Heart J Case Rep ; 8(3): ytae106, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38500489

ABSTRACT

Background: There has been recent growing interest in the use of conduction system pacing (CSP) for both bradycardia and heart failure indications. There remains a paucity of data, however, regarding complications related to the intraventricular septum associated with CSP implant and the management of these events. Case summary: We present a case of a patient with non-ischemic dilated cardiomyopathy presenting for cardiac resynchronization therapy in whom left bundle branch area pacing was complicated with interventricular septal perforation and managed intra-procedurally with repositioning of the lead to provide His bundle pacing (HBP) for QRS correction of underlying left bundle branch block. Post-procedure echocardiography did not show persistent ventricular septal defect. Left ventricular ejection fraction improved from 13% four months before implant to 30% at 32 months post-implant. Corrective HBP pacing thresholds showed a rise at 3-year follow-up. Discussion: Interventricular septal perforation during CSP is a possible complication during lead fixation. Pre-operative septal assessment with imaging can be helpful to provide important septal anatomical features. Septal perforation can be managed appropriately with lead repositioning intra-procedurally and close follow-up.

11.
JAMA Cardiol ; 9(5): 449-456, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38536171

ABSTRACT

Importance: Current left bundle branch block (LBBB) criteria are based on animal experiments or mathematical models of cardiac tissue conduction and may misclassify patients. Improved criteria would impact referral decisions and device type for cardiac resynchronization therapy. Objective: To develop a simple new criterion for LBBB based on electrophysiological studies of human patients, and then to validate this criterion in an independent population. Design, Setting, and Participants: In this diagnostic study, the derivation cohort was from a single-center, prospective study of patients undergoing electrophysiological study from March 2016 through November 2019. The validation cohort was assembled by retrospectively reviewing medical records for patients from the same center who underwent transcatheter aortic valve replacement (TAVR) from October 2015 through May 2022. Exposures: Patients were classified as having LBBB or intraventricular conduction delay (IVCD) as assessed by intracardiac recording. Main Outcomes and Measures: Sensitivity and specificity of the electrocardiography (ECG) criteria assessed in patients with LBBB or IVCD. Results: A total of 75 patients (median [IQR] age, 63 [53-70.5] years; 21 [28.0%] female) with baseline LBBB on 12-lead ECG underwent intracardiac recording of the left ventricular septum: 48 demonstrated complete conduction block (CCB) and 27 demonstrated intact Purkinje activation (IPA). Analysis of surface ECGs revealed that late notches in the QRS complexes of lateral leads were associated with CCB (40 of 48 patients [83.3%] with CCB vs 13 of 27 patients [48.1%] with IPA had a notch or slur in lead I; P = .003). Receiver operating characteristic curves for all septal and lateral leads were constructed, and lead I displayed the best performance with a time to notch longer than 75 milliseconds. Used in conjunction with the criteria for LBBB from the American College of Cardiology/American Heart Association/Heart Rhythm Society, this criterion had a sensitivity of 71% (95% CI, 56%-83%) and specificity of 74% (95% CI, 54%-89%) in the derivation population, contrasting with a sensitivity of 96% (95% CI, 86%-99%) and specificity of 33% (95% CI, 17%-54%) for the Strauss criteria. In an independent validation cohort of 46 patients (median [IQR] age, 78.5 [70-84] years; 21 [45.7%] female) undergoing TAVR with interval development of new LBBB, the time-to-notch criterion demonstrated a sensitivity of 87% (95% CI, 74%-95%). In the subset of 10 patients with preprocedural IVCD, the criterion correctly distinguished IVCD from LBBB in all cases. Application of the Strauss criteria performed similarly in the validation cohort. Conclusions and Relevance: The findings suggest that time to notch longer than 75 milliseconds in lead I is a simple ECG criterion that, when used in conjunction with standard LBBB criteria, may improve specificity for identifying patients with LBBB from conduction block. This may help inform patient selection for cardiac resynchronization or conduction system pacing.


Subject(s)
Bundle-Branch Block , Electrocardiography , Humans , Bundle-Branch Block/physiopathology , Bundle-Branch Block/diagnosis , Bundle-Branch Block/therapy , Female , Male , Aged , Middle Aged , Prospective Studies , Retrospective Studies
12.
Cureus ; 16(1): e51960, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38333484

ABSTRACT

Salmonella is an unusual cause of spontaneous bacterial peritonitis (SBP). It is commonly seen in asymptomatic patients with normal or high ascitic fluid protein levels and an immunocompromised state such as AIDS and hematological and solid organ malignancies other than liver. SBP from non-typhoidal Salmonella species should be considered, even in the absence of underlying immunosuppression. Our patient presented with a history of high-grade fever and frequent loose stools with decompensated alcoholic liver cirrhosis. While evaluating the SBP etiology, ascitic fluid turned out positive for the non-typhoidal Salmonella species, which was red, turbid, and hemorrhagic due to portal vein and superior mesenteric vein thrombosis. We thus report an extremely rare case of SBP caused by Salmonella typhimurium in our patient.

13.
bioRxiv ; 2023 Sep 13.
Article in English | MEDLINE | ID: mdl-37745600

ABSTRACT

Tumor cells rely on increased glycolytic capacity to promote cell growth and progression. While glycolysis is known to be upregulated in the majority of triple negative (TNBC) or basal-like subtype breast cancers, the mechanism remains unclear. Here, we used integrative genomic analyses to identify a subset of basal-like tumors characterized by increased expression of the oncogenic transcription factor SOX4 and its co-factor the SWI/SNF ATPase SMARCA4. These tumors are defined by unique gene expression programs that correspond with increased tumor proliferation and activation of key metabolic pathways, including glycolysis. Mechanistically, we demonstrate that the SOX4-SMARCA4 complex mediates glycolysis through direct transcriptional regulation of Hexokinase 2 (HK2) and that aberrant HK2 expression and altered glycolytic capacity are required to mediate SOX4-SMARCA4-dependent cell growth. Collectively, we have defined the SOX4-SMARCA4-HK2 signaling axis in basal-like breast tumors and established that this axis promotes metabolic reprogramming which is required to maintain tumor cell growth.

14.
J Am Coll Cardiol ; 82(11): 1096-1105, 2023 09 12.
Article in English | MEDLINE | ID: mdl-37673510

ABSTRACT

BACKGROUND: Factors determining hemodynamic stability during human ventricular tachycardia (VT) are incompletely understood. OBJECTIVES: The purposes of this study were to characterize sinus rate (SR) responses during monomorphic VT in association with hemodynamic stability and to prospectively assess the effects of vagolytic therapy on VT tolerance. METHODS: This is a retrospective analysis of patients undergoing scar-related VT ablation. Vasovagal responses were evaluated by analyzing sinus cycle length before VT induction and during VT. SR responses were classified into 3 groups: increasing (≥5 beats/min, sympathetic), decreasing (≥5 beats/min, vagal), and unchanged, with the latter 2 categorized as inappropriate SR. In a prospective cohort (n = 30) that exhibited a failure to increase SR, atropine was administered to improve hemodynamic tolerance to VT. RESULTS: In 150 patients, 261 VT episodes were analyzed (29% untolerated, 71% tolerated) with median VT duration 1.6 minutes. A total of 52% of VT episodes were associated with a sympathetic response, 31% had unchanged SR, and 17% of VTs exhibited a vagal response. A significantly higher prevalence of inappropriate SR responses was observed during untolerated VT (sustained VT requiring cardioversion within 150 seconds) compared with tolerated VT (84% vs 34%; P < 0.001). Untolerated VT was significantly different between groups: 9% (sympathetic), 82% (vagal), and 32% (unchanged) (P < 0.001). Atropine administration improved hemodynamic tolerance to VT in 70%. CONCLUSIONS: Nearly one-half of VT episodes are associated with failure to augment SR, indicative of an under-recognized pathophysiological vasovagal response to VT. Inappropriate SR responses were more predictive of hemodynamic instability than VT rate and ejection fraction. Vagolytic therapy may be a novel method to augment blood pressure during VT.


Subject(s)
Tachycardia, Ventricular , Humans , Prospective Studies , Retrospective Studies , Tachycardia, Ventricular/therapy , Hemodynamics , Atropine/pharmacology , Ubiquitin-Protein Ligases
16.
Cureus ; 15(8): e44394, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37654905

ABSTRACT

Introduction This study aims to differentiate the employment of demineralized bone matrix (DMBM; Osseograft, Advanced Biotech Products (P) Ltd, Chennai, India) and platelet-rich fibrin (PRF) alone to a composite graft consisting of both materials in the surgical actions toward the anomalies of the human periodontal furcation imperfection. Methods In a split-mouth study, 30 patients with mandibular molars affected by the furcation were allocated without conscious choice to test (PRF + DMBM, n = 30) or control (PRF, n = 30) categories. At the starting point, three months after surgery, and six months later, the following modifiable factors were evaluated: probing pocket depth (PPD), full-mouth plaque scores, full-mouth gingival scores, radiographic defect depth, relative vertical clinical attachment level (RVCAL), and relative horizontal clinical attachment level (RHCAL). Results Results at three and six months demonstrated substantial differences between baseline values for both treatment methods in clinical and X-ray imaging appraisal. Nonetheless, the PRF/DMBM group manifests statistically significantly soaring changes observed in comparison to the PRF group. Overall, the probing depth (PD) in the test site was significantly lower than that in the control site, showing a reduction of 68% (95% CI=41%, 95%, p<0.001). Conclusion Clinical indications significantly improved with PRF and DMBM combined instead of PRF alone. On radiographs, the test group also showed higher bone fill.

17.
Circulation ; 148(18): 1354-1367, 2023 10 31.
Article in English | MEDLINE | ID: mdl-37638389

ABSTRACT

BACKGROUND: The circuit boundaries for reentrant ventricular tachycardia (VT) have been historically conceptualized within a 2-dimensional (2D) construct, with their fixed or functional nature unresolved. This study aimed to examine the correlation between localized lines of conduction block (LOB) evident during baseline rhythm with lateral isthmus boundaries that 3-dimensionally constrain the VT isthmus as a hyperboloid structure. METHODS: A total of 175 VT activation maps were correlated with isochronal late activation maps during baseline rhythm in 106 patients who underwent catheter ablation for scar-related VT from 3 centers (42% nonischemic cardiomyopathy). An overt LOB was defined by a deceleration zone with split potentials (≥20 ms isoelectric segment) during baseline rhythm. A novel application of pacing within deceleration zone (≥600 ms) was implemented to unmask a concealed LOB not evident during baseline rhythm. LOB identified during baseline rhythm or pacing were correlated with isthmus boundaries during VT. RESULTS: Among 202 deceleration zones analyzed during baseline rhythm, an overt LOB was evident in 47%. When differential pacing was performed in 38 deceleration zones without overt LOB, an underlying concealed LOB was exposed in 84%. In 152 VT activation maps (2D=53, 3-dimensional [3D]=99), 69% of lateral boundaries colocalized with an LOB in 2D activation patterns, and the depth boundary during 3D VT colocalized with an LOB in 79%. In VT circuits with isthmus regions that colocalized with a U-shaped LOB (n=28), the boundary invariably served as both lateral boundaries in 2D and 3D. Overall, 74% of isthmus boundaries were identifiable as fixed LOB during baseline rhythm or differential pacing. CONCLUSIONS: The majority of VT circuit boundaries can be identified as fixed LOB from intrinsic or paced activation during sinus rhythm. Analysis of activation while pacing within the scar substrate is a novel technique that may unmask concealed LOB, previously interpreted to be functional in nature. An LOB from the perspective of a myocardial surface is frequently associated with intramural conduction, supporting the existence of a 3D hyperboloid VT circuit structure. Catheter ablation may be simplified to targeting both sides around an identified LOB during sinus rhythm.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Humans , Cicatrix , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Arrhythmias, Cardiac , Heart Rate/physiology , Heart Block
18.
J Am Coll Cardiol ; 82(5): 383-397, 2023 08 01.
Article in English | MEDLINE | ID: mdl-37495274

ABSTRACT

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to avoid complications related to transvenous implantable cardioverter-defibrillator (TV-ICD) leads. Device safety and efficacy were demonstrated previously with atypical clinical patients or limited follow-up. OBJECTIVES: The S-ICD PAS (Subcutaneous Implantable Cardioverter-Defibrillator System Post Approval Study) is a real-world, multicenter, registry of U.S. centers that was designed to assess long-term S-ICD safety and efficacy in a diverse group of patients and implantation centers. METHODS: Patients were enrolled in 86 U.S. centers with standard S-ICD indications and were observed for up to 5 years. Efficacy endpoints were first and final shock efficacy. Safety endpoints were complications directly related to the S-ICD system or implantation procedure. Endpoints were assessed using prespecified performance goals. RESULTS: A total of 1,643 patients were prospectively enrolled, with a median follow-up of 4.2 years. All prespecified safety and efficacy endpoint goals were met. Shock efficacy rates for discrete episodes of ventricular tachycardia or ventricular fibrillation were 98.4%, and they did not differ significantly across follow-up years (P = 0.68). S-ICD-related and electrode-related complication-free rates were 93.4% and 99.3%, respectively. Only 1.6% of patients had their devices replaced by a TV-ICD for a pacing need. Cumulative all-cause mortality was 21.7%. CONCLUSIONS: In the largest prospective study of the S-ICD to date, all study endpoints were met, despite a cohort with more comorbidities than in most previous trials. Complication rates were low and shock efficacy was high. These results demonstrate the 5-year S-ICD safety and efficacy for a large, diverse cohort of S-ICD recipients. (Subcutaneous Implantable Cardioverter-Defibrillator [S-ICD] System Post Approval Study [PAS]; NCT01736618).


Subject(s)
Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Treatment Outcome , Prospective Studies , Arrhythmias, Cardiac/therapy , Tachycardia, Ventricular/therapy , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control
19.
Cardiol Clin ; 41(3): 379-391, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37321688

ABSTRACT

Left bundle branch block (LBBB) is not just a simple electrocardiogram alteration. The intricacies of this general terminology go beyond simple conduction block. This review puts together current knowledge on the historical concept of LBBB, clinical significance, and recent insights into the pathophysiology of human LBBB. LBBB is an entity that affects patient diagnosis (primary conduction disease, secondary to underlying pathology or iatrogenic), treatment (cardiac resynchronization therapy or conduction system pacing for heart failure), and prognosis. Recruiting the left bundle branch with conduction system pacing depends on the complex interaction between anatomy, site of pathophysiology, and delivery tools.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Bundle-Branch Block/diagnosis , Bundle-Branch Block/therapy , Heart Conduction System , Electrocardiography , Prognosis , Treatment Outcome , Ventricular Function, Left
20.
Luminescence ; 38(5): 568-575, 2023 May.
Article in English | MEDLINE | ID: mdl-36929687

ABSTRACT

In the current study, α-Bi2 O3 and ß-Bi2 O3 were synthesised using a one-step, novel, solid-solid combustion technique. The reaction rate was increased with the use of microwaves (molecular heating) compared to direct or indirect heating. A strong relationship was observed between the fuel, polymorphic structure, shape and optical properties of the synthesised Bi2 O3 . Photoluminescence studies reveal that two major visible emissions are observed for all samples. The two emissions are distinct with a broad peak in blue and a narrow peak in green. The intensity of the green characteristic emission depends strongly on the heating method used for synthesis and is more intense for microwave-synthesised samples.


Subject(s)
Microwaves
SELECTION OF CITATIONS
SEARCH DETAIL