Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Rev Lett ; 130(21): 215001, 2023 May 26.
Article in English | MEDLINE | ID: mdl-37295115

ABSTRACT

Curved plasma channels have been proposed to guide intense lasers for various applications, such as x-ray laser emission, compact synchrotron radiation, and multistage laser wakefield acceleration [e.g. J. Luo et al., Phys. Rev. Lett. 120, 154801 (2018)PRLTAO0031-900710.1103/PhysRevLett.120.154801]. Here, a carefully designed experiment shows evidences of intense laser guidance and wakefield acceleration in a centimeter-scale curved plasma channel. Both experiments and simulations indicate that when the channel curvature radius is gradually increased and the laser incidence offset is optimized, the transverse oscillation of the laser beam can be mitigated, and the stably guided laser pulse excites wakefields and accelerates electrons along the curved plasma channel to a maximum energy of 0.7 GeV. Our results also show that such a channel exhibits good potential for seamless multistage laser wakefield acceleration.


Subject(s)
Acceleration , Electrons , Heart Rate , Lasers , Plasma
2.
Phys Rev E ; 101(3-1): 033202, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32289989

ABSTRACT

The unique spatial and temporal properties of relativistic high harmonics generated from a laser-driven plasma surface allow them to be coherently focused to an extremely high intensity reaching the Schwinger limit. The ultimately achievable intensity is limited by the harmonic wavefront distortions during the interactions. Here we demonstrate experimentally that the harmonic divergence can be controlled by an optically shaped plasma surface with a prepulse that has the same spatial and temporal distribution as the main laser pulse. Simulations are also performed to explain the experimental observation, and we find that the harmonic wavefront curvature from a dented surface can be precompensated by a convex plasma. Our work suggests an active approach to control the harmonic divergence and wavefront by an optically shaped target. This can be critical for further high harmonics applications.

3.
Rev Sci Instrum ; 89(2): 023505, 2018 Feb.
Article in English | MEDLINE | ID: mdl-29495800

ABSTRACT

We report a new scenario of the time-of-flight technique in which fast neutrons and delayed gamma-ray signals were both recorded in a millisecond time window in harsh environments induced by high-intensity lasers. The delayed gamma signals, arriving far later than the original fast neutron and often being ignored previously, were identified to be the results of radiative captures of thermalized neutrons. The linear correlation between the gamma photon number and the fast neutron yield shows that these delayed gamma events can be employed for neutron diagnosis. This method can reduce the detecting efficiency dropping problem caused by prompt high-flux gamma radiation and provides a new way for neutron diagnosing in high-intensity laser-target interaction experiments.

4.
Rev Sci Instrum ; 87(10): 103301, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27802724

ABSTRACT

We present a novel design of two-dimensional (2D) angular-resolved spectrometer for full beam characterization of ultrashort intense laser driven proton sources. A rotated 2D pinhole array was employed, as selective entrance before a pair of parallel permanent magnets, to sample the full proton beam into discrete beamlets. The proton beamlets are subsequently dispersed without overlapping onto a planar detector. Representative experimental result of protons generated from femtosecond intense laser interaction with thin foil target is presented.

5.
Phys Rev Lett ; 116(20): 205003, 2016 May 20.
Article in English | MEDLINE | ID: mdl-27258873

ABSTRACT

Coherent transition radiation in the terahertz (THz) region with energies of sub-mJ/pulse has been demonstrated by relativistic laser-driven electron beams crossing the solid-vacuum boundary. Targets including mass-limited foils and layered metal-plastic targets are used to verify the radiation mechanism and characterize the radiation properties. Observations of THz emissions as a function of target parameters agree well with the formation-zone and diffraction model of transition radiation. Particle-in-cell simulations also well reproduce the observed characteristics of THz emissions. The present THz transition radiation enables not only a potential tabletop brilliant THz source, but also a novel noninvasive diagnostic for fast electron generation and transport in laser-plasma interactions.

6.
Sci Rep ; 4: 3818, 2014 Jan 22.
Article in English | MEDLINE | ID: mdl-24448655

ABSTRACT

Real-time pulse-contrast observation with a high dynamic range is a prerequisite to tackle the contrast challenge in ultra-high peak-power lasers. However, the commonly used delay-scanning cross-correlator (DSCC) can only provide the time-consumed measurements for repetitive lasers. Single-shot cross-correlator (SSCC) becomes essential in optimizing laser systems and exploring contrast mechanisms. Here we report our progress in developing SSCC towards its practical use. By integrating both the techniques of scattering-noise reduction and sensitive parallel detection into SSCC, we demonstrate a high dynamic range of >10(10), which, to our best knowledge, is the first demonstration of an SSCC with a dynamic range comparable to that of commercial DSCCs. The comparison of high-dynamic measurement performances between SSCC and a standard DSCC (Sequoia, Amplitude Technologies) is also carried out on a 200 TW Ti:sapphire laser, and the consistency of results verifies the veracity of our SSCC.

7.
Opt Express ; 20(6): 5968-73, 2012 Mar 12.
Article in English | MEDLINE | ID: mdl-22418473

ABSTRACT

Lifetime of laser plasma channel is significantly prolonged using femtosecond laser pulse sequence, which is generated from a chirped pulse amplification laser system with pure multi-pass amplification chain. Time-resolved fluorescence images and electrical conductivity measurement are used to characterize the lifetime of the plasma channel. Prolongation of plasma channel lifetime up to microsecond level is observed using the pulse sequence.


Subject(s)
Lasers , Plasma Gases/chemistry , Equipment Design , Equipment Failure Analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...