Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Morphologie ; 102(336): 25-30, 2018 Mar.
Article in English | MEDLINE | ID: mdl-28732678

ABSTRACT

OBJECTIVE OF THE STUDY: To test whether a direct-on-site microscopic examination of fresh, unstained puncture slides by the radiologist decreases the rate of false-negative cases on ultrasound-guided fine-needle cytology of parotid gland masses. PATIENTS: Thirty parotid gland masses from 28 patients were punctured under ultrasound guidance. The same group was used as its control group. METHODS: After one or two passes, the material was spread on slides and air-dried (control group, without microscopic examination). For the study group, it was thus analyzed unstained under the microscope. A sample was considered adequate if at least six clusters of parotid cells were found per slide on at least two slides. For the study group, new punctures were obtained and slides prepared until this condition was fulfilled. RESULTS: Of the 30 evaluated masses, 100% benefited from a cytological diagnosis after microscopy. Twenty-four were adequate in the control group, while 30 were adequate in the study group. The maximum number of punctures to obtain an adequate sample was six. On-site direct microscopy significantly increased the number of adequate specimens by 20% (P=0.03, CI [1.63-20%]). CONCLUSION: Direct and systematic examination of slides by a radiologist avoided the risk of false-negative results caused by having insufficient sample material.


Subject(s)
Biopsy, Fine-Needle/methods , Parotid Gland/pathology , Parotid Neoplasms/diagnosis , Ultrasonography, Interventional/methods , Adult , Aged , False Negative Reactions , Female , Humans , Male , Middle Aged , Parotid Neoplasms/pathology , Prospective Studies , Radiologists , Young Adult
2.
World J Nucl Med ; 13(2): 128-31, 2014 May.
Article in English | MEDLINE | ID: mdl-25191128

ABSTRACT

Maximum standardized uptake value (SUVmax) from fluorodeoxyglucose (FDG) positron emission tomography (PET) scans is a semi quantitative measure that is increasingly used in the clinical practice for diagnostic and therapeutic response assessment purposes. Technological advances such as the implementation of the point spread function (PSF) in the reconstruction algorithm have led to higher signal to noise ratio and increased spatial resolution. The impact on SUVmax measurements has not been studied in clinical setting. We studied the impact of PSF on SUVmax in 30 consecutive lung cancer patients. SUVmax values were measured on PET-computed tomography (CT) scans reconstructed iteratively with and without PSF (respectively high-definition [HD] and non-HD). HD SUVmax values were significantly higher than non-HD SUVmax. There was excellent correlation between HD and non-HD values. Details of reconstruction and PSF implementation in particular have important consequences on SUV values. Nuclear Medicine physicians and radiologists should be aware of the reconstruction parameters of PET-CT scans when they report or rely on SUV measurements.

SELECTION OF CITATIONS
SEARCH DETAIL
...