Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 31
Filter
1.
Phys Med Biol ; 69(11)2024 May 30.
Article in English | MEDLINE | ID: mdl-38722545

ABSTRACT

Objective.In this work, we aim to propose an accurate and robust spectrum estimation method by synergistically combining x-ray imaging physics with a convolutional neural network (CNN).Approach.The approach relies on transmission measurements, and the estimated spectrum is formulated as a convolutional summation of a few model spectra generated using Monte Carlo simulation. The difference between the actual and estimated projections is utilized as the loss function to train the network. We contrasted this approach with the weighted sums of model spectra approach previously proposed. Comprehensive studies were performed to demonstrate the robustness and accuracy of the proposed approach in various scenarios.Main results.The results show the desirable accuracy of the CNN-based method for spectrum estimation. The ME and NRMSE were -0.021 keV and 3.04% for 80 kVp, and 0.006 keV and 4.44% for 100 kVp, superior to the previous approach. The robustness test and experimental study also demonstrated superior performances. The CNN-based approach yielded remarkably consistent results in phantoms with various material combinations, and the CNN-based approach was robust concerning spectrum generators and calibration phantoms.Significance. We proposed a method for estimating the real spectrum by integrating a deep learning model with real imaging physics. The results demonstrated that this method was accurate and robust in estimating the spectrum, and it is potentially helpful for broad x-ray imaging tasks.


Subject(s)
Monte Carlo Method , Neural Networks, Computer , Phantoms, Imaging , X-Rays , Image Processing, Computer-Assisted/methods
2.
Phys Rev Lett ; 132(15): 152502, 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38682998

ABSTRACT

^{134}Xe is a candidate isotope for neutrinoless double beta decay (0νßß) search. In addition, the two-neutrino case (2νßß) allowed by the standard model of particle physics has not yet been observed. With the 656-kg natural xenon in the fiducial volume of the PandaX-4T detector, which contains 10.4% of ^{134}Xe, and its initial 94.9-day exposure, we have established the most stringent constraints on 2νßß and 0νßß of ^{134}Xe half-lives, with limits of 2.8×10^{22} yr and 3.0×10^{23} yr at 90% confidence level, respectively. The 2νßß (0νßß) limit surpasses the previously reported best result by a factor of 32 (2.7), highlighting the potential of large monolithic natural xenon detectors for double beta decay searches.

3.
Phys Med Biol ; 69(10)2024 May 08.
Article in English | MEDLINE | ID: mdl-38640915

ABSTRACT

Objective. Beam hardening (BH) artifacts in computed tomography (CT) images originate from the polychromatic nature of x-ray photons. In a CT system with a bowtie filter, residual BH artifacts remain when polynomial fits are used. These artifacts lead to worse visuals, reduced contrast, and inaccurate CT numbers. This work proposes a pixel-by-pixel correction (PPC) method to reduce the residual BH artifacts caused by a bowtie filter.Approach. The energy spectrum for each pixel at the detector after the photons pass through the bowtie filter was calculated. Then, the spectrum was filtered through a series of water slabs with different thicknesses. The polychromatic projection corresponding to the thickness of the water slab for each detector pixel could be obtained. Next, we carried out a water slab experiment with a mono energyE= 69 keV to get the monochromatic projection. The polychromatic and monochromatic projections were then fitted with a 2nd-order polynomial. The proposed method was evaluated on digital phantoms in a virtual CT system and phantoms in a real CT machine.Main results. In the case of a virtual CT system, the standard deviation of the line profile was reduced by 23.8%, 37.3%, and 14.3%, respectively, in the water phantom with different shapes. The difference of the linear attenuation coefficients (LAC) in the central and peripheral areas of an image was reduced from 0.010 to 0.003cm-1and 0.007cm-1to 0 in the biological tissue phantom and human phantom, respectively. The method was also validated using CT projection data obtained from Activion16 (Canon Medical Systems, Japan). The difference in the LAC in the central and peripheral areas can be reduced by a factor of two.Significance. The proposed PPC method can successfully remove the cupping artifacts in both virtual and authentic CT images. The scanned object's shapes and materials do not affect the technique.


Subject(s)
Artifacts , Image Processing, Computer-Assisted , Phantoms, Imaging , Tomography, X-Ray Computed , Tomography, X-Ray Computed/methods , Image Processing, Computer-Assisted/methods , Humans
4.
Quant Imaging Med Surg ; 14(3): 2671-2692, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38545053

ABSTRACT

Background and Objective: As one of the main treatment modalities, radiotherapy (RT) (also known as radiation therapy) plays an increasingly important role in the treatment of cancer. RT could benefit greatly from the accurate localization of the gross tumor volume and circumambient organs at risk (OARs). Modern linear accelerators (LINACs) are typically equipped with either gantry-mounted or room-mounted X-ray imaging systems, which provide possibilities for marker-less tracking with two-dimensional (2D) kV X-ray images. However, due to organ overlapping and poor soft tissue contrast, it is challenging to track the target directly and precisely with 2D kV X-ray images. With the flourishing development of deep learning in the field of image processing, it is possible to achieve real-time marker-less tracking of targets with 2D kV X-ray images in RT using advanced deep-learning frameworks. This article sought to review the current development of deep learning-based target tracking with 2D kV X-ray images and discuss the existing limitations and potential solutions. Finally, it also discusses some common challenges and potential future developments. Methods: Manual searches of the Web of Science, and PubMed, and Google Scholar were carried out to retrieve English-language articles. The keywords used in the searches included "radiotherapy, radiation therapy, motion tracking, target tracking, motion estimation, motion monitoring, X-ray images, digitally reconstructed radiographs, deep learning, convolutional neural network, and deep neural network". Only articles that met the predetermined eligibility criteria were included in the review. Ultimately, 23 articles published between March 2019 and December 2023 were included in the review. Key Content and Findings: In this article, we narratively reviewed deep learning-based target tracking with 2D kV X-ray images in RT. The existing limitations, common challenges, possible solutions, and future directions of deep learning-based target tracking were also discussed. The use of deep learning-based methods has been shown to be feasible in marker-less target tracking and real-time motion management. However, it is still quite challenging to directly locate tumor and OARs in real-time with 2D kV X-ray images, and more technical and clinical efforts are needed. Conclusions: Deep learning-based target tracking with 2D kV X-ray images is a promising method in motion management during RT. It has the potential to track the target in real time, recognize motion, reduce the extended margin, and better spare the normal tissue. However, it still has many issues that demand prompt attention, and further development before it can be put into clinical practice.

5.
Phys Med Biol ; 69(3)2024 Jan 31.
Article in English | MEDLINE | ID: mdl-38157549

ABSTRACT

Objective.Relative biological effectiveness (RBE) plays a vital role in carbon ion radiotherapy, which is a promising treatment method for reducing toxic effects on normal tissues and improving treatment efficacy. It is important to have an effective and precise way of obtaining RBE values to support clinical decisions. A method of calculating RBE from a mechanistic perspective is reported.Approach.Ratio of dose to obtain the same number of double strand breaks (DSBs) between different radiation types was used to evaluate RBE. Package gMicroMC was used to simulate DSB yields. The DSB inductions were then analyzed to calculate RBE. The RBE values were compared with experimental results.Main results.Furusawa's experiment yielded RBE values of 1.27, 2.22, 3.00 and 3.37 for carbon ion beam with dose-averaged LET of 30.3 keVµm-1, 54.5 keVµm-1, 88 keVµm-1and 137 keVµm-1, respectively. RBE values computed from gMicroMC simulations were 1.75, 2.22, 2.87 and 2.97. When it came to a more sophisticated carbon ion beam with 6 cm spread-out Bragg peak, RBE values were 1.61, 1.63, 2.19 and 2.36 for proximal, middle, distal and distal end part, respectively. Values simulated by gMicroMC were 1.50, 1.87, 2.19 and 2.34. The simulated results were in reasonable agreement with the experimental data.Significance.As a mechanistic way for the evaluation of RBE for carbon ion radiotherapy by combining the macroscopic simulation of energy spectrum and microscopic simulation of DNA damages, this work provides a promising tool for RBE calculation supporting clinical applications such as treatment planning.


Subject(s)
Carbon , Heavy Ion Radiotherapy , Relative Biological Effectiveness , Carbon/therapeutic use , DNA Damage , Ions , Monte Carlo Method
6.
Phys Rev Lett ; 131(19): 191002, 2023 Nov 10.
Article in English | MEDLINE | ID: mdl-38000419

ABSTRACT

We report results of a search for dark-matter-nucleon interactions via a dark mediator using optimized low-energy data from the PandaX-4T liquid xenon experiment. With the ionization-signal-only data and utilizing the Migdal effect, we set the most stringent limits on the cross section for dark matter masses ranging from 30 MeV/c^{2} to 2 GeV/c^{2}. Under the assumption that the dark mediator is a dark photon that decays into scalar dark matter pairs in the early Universe, we rule out significant parameter space of such thermal relic dark-matter model.

7.
Cancers (Basel) ; 15(22)2023 Nov 20.
Article in English | MEDLINE | ID: mdl-38001738

ABSTRACT

PURPOSE: To develop a deep learning framework based on a hybrid dataset to enhance the quality of CBCT images and obtain accurate HU values. MATERIALS AND METHODS: A total of 228 cervical cancer patients treated in different LINACs were enrolled. We developed an encoder-decoder architecture with residual learning and skip connections. The model was hierarchically trained and validated on 5279 paired CBCT/planning CT images and tested on 1302 paired images. The mean absolute error (MAE), peak signal to noise ratio (PSNR), and structural similarity index (SSIM) were utilized to access the quality of the synthetic CT images generated by our model. RESULTS: The MAE between synthetic CT images generated by our model and planning CT was 10.93 HU, compared to 50.02 HU for the CBCT images. The PSNR increased from 27.79 dB to 33.91 dB, and the SSIM increased from 0.76 to 0.90. Compared with synthetic CT images generated by the convolution neural networks with residual blocks, our model had superior performance both in qualitative and quantitative aspects. CONCLUSIONS: Our model could synthesize CT images with enhanced image quality and accurate HU values. The synthetic CT images preserved the edges of tissues well, which is important for downstream tasks in adaptive radiotherapy.

8.
Phys Rev Lett ; 131(4): 041001, 2023 Jul 28.
Article in English | MEDLINE | ID: mdl-37566838

ABSTRACT

We report a search for light dark matter produced through the cascading decay of η mesons, which are created as a result of inelastic collisions between cosmic rays and Earth's atmosphere. We introduce a new and general framework, publicly accessible, designed to address boosted dark matter specifically, with which a full and dedicated simulation including both elastic and quasielastic processes of Earth attenuation effect on the dark matter particles arriving at the detector is performed. In the PandaX-4T commissioning data of 0.63 tonne·year exposure, no significant excess over background is observed. The first constraints on the interaction between light dark matter generated in the atmosphere and nucleus through a light scalar mediator are obtained. The lowest excluded cross section is set at 5.9×10^{-37} cm^{2} for a dark matter mass of 0.1 MeV/c^{2} and mediator mass of 300 MeV/c^{2}. The lowest upper limit of η to the dark matter decay branching ratio is 1.6×10^{-7}.

9.
Phys Rev Lett ; 130(26): 261001, 2023 Jun 30.
Article in English | MEDLINE | ID: mdl-37450819

ABSTRACT

We report the search results of light dark matter through its interactions with shell electrons and nuclei, using the commissioning data from the PandaX-4T liquid xenon detector. Low energy events are selected to have an ionization-only signal between 60 to 200 photoelectrons, corresponding to a mean nuclear recoil energy from 0.77 to 2.54 keV and electronic recoil energy from 0.07 to 0.23 keV. With an effective exposure of 0.55 tonne·year, we set the most stringent limits within a mass range from 40 MeV/c^{2} to 10 GeV/c^{2} for pointlike dark matter-electron interaction, 100 MeV/c^{2} to 10 GeV/c^{2} for dark matter-electron interaction via a light mediator, and 3.2 to 4 GeV/c^{2} for dark matter-nucleon spin-independent interaction. For DM interaction with electrons, our limits are closing in on the parameter space predicted by the freeze-in and freeze-out mechanisms in the early Universe.


Subject(s)
Cell Nucleus , Electrons
11.
Sci Bull (Beijing) ; 68(8): 779-782, 2023 Apr 30.
Article in English | MEDLINE | ID: mdl-37024326
12.
Phys Rev Lett ; 130(7): 071902, 2023 Feb 17.
Article in English | MEDLINE | ID: mdl-36867831

ABSTRACT

Chiral perturbation theory and its unitarized versions have played an important role in our understanding of the low-energy strong interaction. Yet, so far, such studies typically deal exclusively with perturbative or nonperturbative channels. In this Letter, we report on the first global study of meson-baryon scattering up to one-loop order. It is shown that covariant baryon chiral perturbation theory, including its unitarization for the negative strangeness sector, can describe meson-baryon scattering data remarkably well. This provides a highly nontrivial check on the validity of this important low-energy effective field theory of QCD. We show that the K[over ¯]N related quantities can be better described in comparison with those of lower-order studies, and with reduced uncertainties due to the stringent constraints from the πN and KN phase shifts. In particular, we find that the two-pole structure of Λ(1405) persists up to one-loop order reinforcing the existence of two-pole structures in dynamically generated states.

13.
Phys Rev Lett ; 130(2): 021802, 2023 Jan 13.
Article in English | MEDLINE | ID: mdl-36706410

ABSTRACT

A search for interactions from solar ^{8}B neutrinos elastically scattering off xenon nuclei using PandaX-4T commissioning data is reported. The energy threshold of this search is further lowered compared with the previous search for dark matter, with various techniques utilized to suppress the background that emerges from data with the lowered threshold. A blind analysis is performed on the data with an effective exposure of 0.48 tonne year, and no significant excess of events is observed. Among the results obtained using the neutrino-nucleus coherent scattering, our results give the best constraint on the solar ^{8}B neutrino flux. We further provide a more stringent limit on the cross section between dark matter and nucleon in the mass range from 3 to 9 GeV/c^{2}.

15.
Rep Prog Phys ; 86(1)2023 Jan 06.
Article in English | MEDLINE | ID: mdl-36279851

ABSTRACT

Rare meson decays are among the most sensitive probes of both heavy and light new physics. Among them, new physics searches using kaons benefit from their small total decay widths and the availability of very large datasets. On the other hand, useful complementary information is provided by hyperon decay measurements. We summarize the relevant phenomenological models and the status of the searches in a comprehensive list of kaon and hyperon decay channels. We identify new search strategies for under-explored signatures, and demonstrate that the improved sensitivities from current and next-generation experiments could lead to a qualitative leap in the exploration of light dark sectors.

16.
Sci Bull (Beijing) ; 67(17): 1735-1738, 2022 09 15.
Article in English | MEDLINE | ID: mdl-36546057
17.
Sci Bull (Beijing) ; 67(22): 2298-2304, 2022 Nov 30.
Article in English | MEDLINE | ID: mdl-36546220

ABSTRACT

Weak radiative hyperon decays, important to test the strong interaction and relevant in searches for beyond the standard model physics, have remained puzzling both experimentally and theoretically for a long time. The recently updated branching fraction and first measurement of the asymmetry parameter of Λ→nγ by the BESIII Collaboration further exacerbate the issue, as none of the existing predictions can describe the data. We show in this work that the covariant baryon chiral perturbation theory, with constraints from the latest measurements of hyperon non-leptonic decays, can well describe the BESIII data. The predicted branching fraction and asymmetry parameter for Ξ-→Σ-γ are also in agreement with the experimental data. We note that a more precise measurement of the asymmetry parameter, which is strongly constrained by chiral symmetry and related with that of Σ+→pγ, is crucial to test Hara's theorem. We further predict the branching fraction and asymmetry parameter of Σ0→nγ, whose future measurement can serve as a highly nontrivial check on our understanding of weak radiative hyperon decays and on the covariant baryon chiral perturbation theory.

18.
Phys Rev Lett ; 129(16): 161803, 2022 Oct 14.
Article in English | MEDLINE | ID: mdl-36306747

ABSTRACT

Compared with the signature of dark matter elastic scattering off nuclei, the absorption of fermionic dark matter by nuclei opens up a new searching channel for light dark matter with a characteristic monoenergetic signal. In this Letter, we explore the 95.0-day data from the PandaX-4T commissioning run and report the first dedicated searching results of the fermionic dark matter absorption signal through a neutral current process. No significant signal was found, and the lowest limit on the dark matter-nucleon interaction cross section is set to be 1.5×10^{-50} cm^{2} for a fermionic dark matter mass of 40 MeV/c^{2} with 90% confidence level.

19.
Phys Rev Lett ; 129(16): 161804, 2022 Oct 14.
Article in English | MEDLINE | ID: mdl-36306755

ABSTRACT

We report a search on sub-MeV fermionic dark matter absorbed by electrons with an outgoing active neutrino using the 0.63 tonne year exposure collected by the PandaX-4T liquid xenon experiment. No significant signals are observed over the expected background. The data are interpreted into limits to the effective couplings between such dark matter and the electron. For axial-vector or vector interactions, our sensitivity is competitive in comparison to existing astrophysical bounds on the decay of such a dark matter candidate into photon final states. In particular, we present the first direct detection limits for a vector (axial-vector) interaction which are the strongest in the mass range from 35 to 55 (25 to 45) keV/c^{2} in comparison to other astrophysical and cosmological constraints.

20.
Phys Med Biol ; 67(15)2022 07 19.
Article in English | MEDLINE | ID: mdl-35738247

ABSTRACT

Objective.Material decomposition (MD) evaluates the elemental composition of human tissues and organs via computed tomography (CT) and is indispensable in correlating anatomical images with functional ones. A major issue in MD is inaccurate elemental information about the real human body. To overcome this problem, we developed a virtual CT system model, by which various reconstructed images can be generated based on ICRP110 human phantoms with information about six major elements (H, C, N, O, P, and Ca).Approach.We generated CT datasets labelled with accurate elemental information using the proposed generative CT model and trained a deep learning (DL)-based model to estimate the material distribution with the ICRP110 based human phantom as well as the digital Shepp-Logan phantom. The accuracy in quad-, dual-, and single-energy CT cases was investigated. The influence of beam-hardening artefacts, noise, and spectrum variations were analysed with testing datasets including elemental density and anatomical shape variations.Main results.The results indicated that this DL approach can realise precise MD, even with single-energy CT images. Moreover, noise, beam-hardening artefacts, and spectrum variations were shown to have minimal impact on the MD.Significance.Present results suggest that the difficulty to prepare a large CT database can be solved by introducing the virtual CT system and the proposed technique can be applied to clinical radiodiagnosis and radiotherapy.


Subject(s)
Deep Learning , Artifacts , Humans , Image Processing, Computer-Assisted/methods , Phantoms, Imaging , Tomography, X-Ray Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...