1.
Article in English | MEDLINE | ID: mdl-38688451

ABSTRACT

OBJECTIVES: To evaluate whether warfarin targeted at an international normalized ratio of 1.8 (range, 1.5-2.0) after On-X mechanical aortic valve implant is safe for all patients. METHODS: This prospective, observational clinical registry assessed adverse event rates in adult patients receiving low-dose warfarin (target international normalized ratio, 1.8; range, 1.5-2.0) plus daily aspirin (75-100 mg) during a 5-year period after On-X aortic valve implant. The primary end point is the combined rate of major bleeding, valve thrombosis, and thromboembolism overall and in 4 subgroups. The comparator is the Prospective Randomized On-X Anticoagulation Trial control group patients on standard-dose warfarin (international normalized ratio, 2.0-3.0) plus aspirin 81 milligrams daily. RESULTS: A total of 510 patients were recruited at 23 centers in the United States, United Kingdom, and Canada between November 2015 and January 2022. This interim analysis includes 229 patients scheduled to complete 5-year follow-up by August 16, 2023. The linearized occurrence rate (in percent per patient-year) of the primary composite end point of major bleeding, valve thrombosis, and thromboembolism is 1.83% compared with 5.39% (95% confidence interval, 4.12%-6.93%) in the comparator group. Results are consistent in clinic-monitored and home-monitored patients and in those at high risk for thromboembolism. Major bleeding and total bleeding were reduced by 87% and 71%, respectively, versus the comparator group, without an increase in thromboembolic events. CONCLUSIONS: Interim results support the continued safety of the On-X aortic mechanical valve with a target international normalized ratio of 1.8 plus low-dose aspirin through 5 years after implant, with or without home monitoring.

2.
Ann Thorac Surg ; 117(6): 1176-1177, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38608745
3.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38621698

ABSTRACT

OBJECTIVES: To assess if warfarin targeted to international normalized ratio (INR) 1.8 (range 1.5-2.0) is safe for all patients with an On-X aortic mechanical valve. METHODS: This prospective, observational registry follows patients receiving warfarin targeted at an INR of 1.8 (range 1.5-2.0) plus daily aspirin (75-100 mg) after On-X aortic valve replacement. The primary end point is a composite of thromboembolism, valve thrombosis and major bleeding. Secondary end points include the individual rates of thromboembolism, valve thrombosis and major bleeding, as well as the composite in subgroups of home or clinic-monitored INR and risk categorization for thromboembolism. The control was the patient group randomized to standard-dose warfarin (INR 2.0-3.0) plus daily aspirin 81 mg from the PROACT trial. RESULTS: A total of 510 patients were enroled at 23 centres in the UK, USA and Canada. Currently, the median follow-up duration is 3.4 years, and median achieved INR is 1.9. The primary composite end point rate in the low INR patients is 2.31% vs 5.39% (95% confidence interval 4.12-6.93%) per patient-year in the PROACT control group, constituting a 57% reduction. Results are consistent in subgroups of home or clinic-monitored, and high-risk patients, with reductions of 56%, 57% and 57%, respectively. Major and total bleeding are decreased by 85% and 73%, respectively, with similar rates of thromboembolic events. No valve thrombosis occurred. CONCLUSIONS: Interim results suggest that warfarin targeted at an INR of 1.8 (range 1.5-2.0) plus aspirin is safe and effective in patients with an On-X aortic mechanical valve with or without home INR monitoring.


Subject(s)
Anticoagulants , Aortic Valve , Aspirin , Heart Valve Prosthesis Implantation , International Normalized Ratio , Thromboembolism , Warfarin , Humans , Warfarin/administration & dosage , Warfarin/adverse effects , Aspirin/administration & dosage , Aspirin/adverse effects , Male , Female , Aortic Valve/surgery , Anticoagulants/administration & dosage , Anticoagulants/adverse effects , Prospective Studies , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Aged , Thromboembolism/prevention & control , Thromboembolism/etiology , Middle Aged , Heart Valve Prosthesis/adverse effects , Thrombosis/prevention & control , Thrombosis/etiology , Hemorrhage/chemically induced
5.
JTCVS Open ; 14: 205-213, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37425466

ABSTRACT

Despite the benefits established for multiple surgical specialties, enhanced recovery after surgery has been underused in cardiac surgery. A cardiac enhanced recovery after surgery summit was convened at the 102nd American Association for Thoracic Surgery annual meeting in May 2022 for experts to convey key enhanced recovery after surgery concepts, best practices, and applicable results for cardiac surgery. Topics included implementation of enhanced recovery after surgery, prehabilitation and nutrition, rigid sternal fixation, goal-directed therapy, and multimodal pain management.

6.
Ann Thorac Surg ; 115(4): 929-938, 2023 04.
Article in English | MEDLINE | ID: mdl-36610532

ABSTRACT

BACKGROUND: Current guidelines recommend a target international normalized ratio (INR) range of 2.5 to 3.5 in patients with a mechanical mitral prosthesis. The Prospective Randomized On-X Anticoagulation Clinical Trial (PROACT) Mitral randomized controlled noninferiority trial assessed safety and efficacy of warfarin at doses lower than currently recommended in patients with an On-X (Artivion, Inc) mechanical mitral valve. METHODS: After On-X mechanical mitral valve replacement, followed by at least 3 months of standard anticoagulation, 401 patients at 44 North American centers were randomized to low-dose warfarin (target INR, 2.0-2.5) or standard-dose warfarin (target INR, 2.5-3.5). All patients were prescribed aspirin, 81 mg daily, and encouraged to use home INR testing. The primary end point was the sum of the linearized rates of thromboembolism, valve thrombosis, and bleeding events. The design was based on an expected 7.3% event rate and 1.5% noninferiority margin. RESULTS: Mean patient follow-up was 4.1 years. Mean INR was 2.47 and 2.92 (P <.001) in the low-dose and standard-dose warfarin groups, respectively. Primary end point rates were 11.9% per patient-year in the low-dose group and 12.0% per patient-year in the standard-dose group (difference, -0.07%; 95% CI, -3.40% to 3.26%). The CI >1.5%, thus noninferiority was not achieved. Rates (percentage per patient-year) of the individual components of the primary end point were 2.3% vs 2.5% for thromboembolism, 0.5% vs 0.5% for valve thrombosis, and 9.13% vs 9.04% for bleeding. CONCLUSIONS: Compared with standard-dose warfarin, low-dose warfarin did not achieve noninferiority for the composite primary end point. (PROACT Clinicaltrials.gov number, NCT00291525).


Subject(s)
Heart Valve Prosthesis Implantation , Thromboembolism , Thrombosis , Humans , Warfarin/adverse effects , Anticoagulants/adverse effects , Prospective Studies , Mitral Valve/surgery , Thromboembolism/etiology , Thromboembolism/prevention & control , Hemorrhage/etiology , Thrombosis/etiology , Heart Valve Prosthesis Implantation/adverse effects
7.
Innovations (Phila) ; 17(6): 463-470, 2022.
Article in English | MEDLINE | ID: mdl-36373654

ABSTRACT

OBJECTIVE: Patients with elevated CHA2DS2-VASc scores are at high risk for atrial fibrillation (AF) and thromboembolic events (TE) after cardiac surgery. Left atrial appendage exclusion (LAAE) is a permanent, continuous approach to stroke prevention in AF, overcoming limitations of oral anticoagulation (OAC). We report ATLAS trial results focused on LAAE technical success and perioperative safety and TE rates with and without LAAE in cardiac surgery patients who developed postoperative AF (POAF). METHODS: ATLAS (NCT02701062) was a prospective, multicenter, feasibility trial. Patients age ≥18 years, undergoing structural heart procedure, with no preoperative AF, CHA2DS2-VASc ≥2, and HAS-BLED ≥2 were randomized 2:1 to LAAE or no LAAE. Patients who developed POAF and/or received LAAE were followed for 1 year. LAAE was evaluated with intraoperative transesophageal echocardiography. RESULTS: A total of 562 patients were randomized to LAAE (n = 376) or no LAAE (n = 186). Mean CHA2DS2-VASc (3.4 vs 3.4) and HAS-BLED (2.8 vs 2.9) scores were similar for LAAE and no LAAE groups. LAAE success (no flow nor residual stump >10 mm) was 99%. One LAAE-related serious adverse event (0.27%) occurred and was resolved without sequelae. There were 44.3% of patients who developed POAF. Through 1 year, 3.4% of LAAE patients and 5.6% of no LAAE patients had TE. OAC was used by 32.5% of POAF patients. Bleeding was higher with OAC than without (16.1% vs 5.4%, P = 0.008). CONCLUSIONS: ATLAS demonstrated a high rate of successful LAAE with low LAAE-related serious adverse events in cardiac surgery patients. Study results should be considered in future trial design to further evaluate prophylactic LAAE for stroke prevention in cardiac surgery patients with elevated stroke risk.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cardiac Surgical Procedures , Stroke , Humans , Adolescent , Risk Factors , Risk Assessment/methods , Atrial Appendage/surgery , Prospective Studies , Cardiac Surgical Procedures/adverse effects , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control , Hemorrhage/complications , Atrial Fibrillation/surgery
9.
JTCVS Tech ; 14: 55-65, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35967205

ABSTRACT

Objectives: Geometric ring annuloplasty has shown promise during bicuspid aortic valve repair for aortic insufficiency. This study examined early outcomes of bicuspid aortic valve repair associated with proximal aortic aneurysm replacement. Methods: From September 2017 to November, 2021, 127 patients underwent bicuspid aortic valve repair with concomitant proximal aneurysm reconstruction. Patient age was 50.6 ± 12.7 years (mean ± standard deviation), male gender was 83%, New York Heart Association Class was 2 (1-2) (median [interquartile range]), and preoperative aortic insufficiency grade was 3 (2-4). Ascending aortic diameter was 50 (46-54) mm, and all patients had ascending aortic replacement. Forty patients had sinus diameters greater than 45 mm, prompting remodeling root procedures. A total of 105 patients had Sievers type 1 valves, 3 patients had type 0, and 7 patients had type 2. A total of 118 patients had primarily right/left fusion, 8 patients had right/nonfusion, and 1 patient had left/nonfusion. Leaflet reconstruction used central leaflet plication and cleft closure, with limited ultrasonic decalcification in 31 patients. Results: Ring size was 23 (21-23) mm, and 26 of 40 root procedures were selective nonfused sinus replacements. Aortic clamp time was 139 (112-170) minutes, and bypass time was 178 (138-217) minutes. Postrepair aortic insufficiency grade was 0 (0-0) (P < .0001), and mean valve gradient was 10 (7-14) mm Hg. No early and 1 late mortality occurred. Four patients required reoperation for bleeding, and 4 patients required pacemakers. At a mean follow-up of 20 months (maximal 93), there were no valve-related complications, 5 late repair failures prompting valve replacement, and 1 death due to Coronavirus Disease 2019. Conclusions: Geometric ring annuloplasty for bicuspid aortic valve repair with proximal aortic aneurysm reconstruction is safe and associated with good early outcomes. Further experience and follow-up will help inform long-term durability.

10.
Prog Cardiovasc Dis ; 72: 31-40, 2022.
Article in English | MEDLINE | ID: mdl-35738422

ABSTRACT

Patients who need a prosthetic aortic heart valve may decide, working with their cardiologist and cardiac surgeon, among a variety of options: surgical or transcatheter approach, bioprosthetic or mechanical valve, or a Ross procedure if suitable to their age and anatomy. This review article examines the evidence for survival benefit with mechanical aortic valves, discusses bioprosthetic structural valve degeneration and its consequences, and considers the risks of redo aortic valve surgery or subsequent valve-in-valve (ViV) transcatheter intervention. It highlights the unique characteristics of the On-X aortic valve, including the US Food and Drug Administration approved and American College of Cardiology/American Heart Association guideline supported reduced anticoagulation target INR of 1.5 to 2.0, and discusses the PROACT Xa trial comparing apixaban vs warfarin anticoagulation. The choice of prosthetic valve should be individualized, carefully considering each patient's unique circumstances. In that context, the On-X aortic valve offers a potential lifetime solution without need for a repeat operation, while minimizing the risks of long-term anticoagulation. In an era of enthusiasm for bioprosthetic and transcatheter-based approaches, the option of a second-generation bileaflet mechanical valve with optimized hemodynamics-the On-X aortic valve-may well align with patient expectations.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Anticoagulants/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/methods , Humans , Prosthesis Design , Prosthesis Failure , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
13.
Innovations (Phila) ; 17(1): 42-49, 2022.
Article in English | MEDLINE | ID: mdl-35225065

ABSTRACT

OBJECTIVE: Up to 28% of patients may need mitral valve (MV) surgery after transcatheter edge-to-edge repair (TEER). This study evaluates the outcomes of minimally invasive MV surgery after TEER. Methods: International multicenter registry of minimally invasive MV surgery after TEER between 2013 and 2020. Subgroups were stratified by the number of devices implanted (≤1 vs >1), as well as time interval from TEER to surgery (≤1 year vs >1 year). Results: A total of 56 patients across 13 centers were included with a mean age of 73 ± 11 years, and 50% were female. The median Society of Thoracic Surgeons Predicted Risk of Mortality (STS PROM) score for MV replacement was 8% (Q1-Q3 = 5% to 11%) and the ratio of observed to expected mortality was 0.9. The etiology of mitral regurgitation (MR) prior to TEER was primary MR in 75% of patients and secondary MR in 25%. There were 30 patients (54%) who had >1 device implanted. The median time between TEER and surgery was 252 days (33 to 636 days). Hemodynamics, including MR severity, MV area, and mean gradient, significantly improved after minimally invasive surgery and sustained to 1-year follow-up. In-hospital and 30-day mortality was 7.1%, and 1-year actuarial survival was 85.6% ± 6%. Conclusions: Minimally invasive MV surgery after TEER may be achieved as predicted by the STS PROM. Most patients underwent MV replacement instead of repair. As TEER is applied more widely, patients should be informed about the potential need for surgical intervention over time after TEER. These discussions will allow better informed consent and post-procedure planning.


Subject(s)
Cardiac Surgical Procedures , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Aged , Aged, 80 and over , Cardiac Surgical Procedures/adverse effects , Female , Heart Valve Prosthesis Implantation/methods , Humans , Male , Middle Aged , Minimally Invasive Surgical Procedures/adverse effects , Mitral Valve/surgery , Mitral Valve Insufficiency/etiology , Registries , Treatment Outcome
14.
Ann Thorac Surg ; 2022 01 28.
Article in English | MEDLINE | ID: mdl-35101419

ABSTRACT

This article has been withdrawn at the request of the author(s) and/or editor. The Publisher apologizes for any inconvenience this may cause. The full Elsevier Policy on Article Withdrawal can be found at https://www.elsevier.com/about/our-business/policies/article-withdrawal.

15.
Ann Thorac Surg ; 114(5): e383, 2022 11.
Article in English | MEDLINE | ID: mdl-35192795

Subject(s)
Liver , Humans , RNA, Messenger
16.
J Card Surg ; 37(1): 70-75, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34669217

ABSTRACT

OBJECTIVES: As aortic valve repair (AVr) for aortic insufficiency (AI) expands, minimally invasive (Mi) approaches are increasingly being applied. Cardiac surgical techniques can be more difficult through small incisions, and this report analyzes medium-term outcomes for MiAVr facilitated by geometric ring annuloplasty. METHODS: Since 2013, 58 patients were selected for AVr through upper sternotomy third-interspace incisions. The average age was 58.9 ± 15.4 (mean ± SD) years, 71% were male, and preoperative AI grade was 3.6 ± 0.8. Sixty-two percent (36/58) had a proximal aortic replacement for ascending aortic aneurysms (n = 26) and/or remodeling grafts for aortic root aneurysms (n = 10). Annuloplasty rings were placed subannularly (69% trileaflet; 31% bicuspid), and leaflet procedures were performed in 70%. The average ring diameter was 21.6 ± 1.4 mm, and the average aortic clamp time was 113 ± 35 min. RESULTS: After repair, AI grade fell to an average of 0.5 ± 0.6 (p < .0001), with a mean valve gradient of 12.5 ± 7.1 mmHg. No operative mortalities or major complications occurred. Three patients required reoperations for bleeding, and two had pacemakers. At an average follow-up of 38 months (maximal 88 months), three late deaths and no valve-related complications were observed. Four patients required reoperative aortic valve replacement over follow-up, and Kaplan-Meier survival and freedom from reoperation both exceeded 80% at 88 months. At the last follow-up, the average AI grade was 0.7 ± 0.7, and the mean valve gradient was 12.7 ± 6.3 mmHg. CONCLUSIONS: Geometric ring annuloplasty was safe and seemed to facilitate performing AVr ± proximal aortic replacement through Mi incisions. Hemodynamic improvements were significant, medium-term clinical outcomes were acceptable, and results could improve further with experience.


Subject(s)
Aortic Valve Insufficiency , Cardiac Valve Annuloplasty , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Adult , Aged , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Humans , Male , Middle Aged , Reoperation , Treatment Outcome
17.
Ann Thorac Surg ; 113(3): e183-e185, 2022 03.
Article in English | MEDLINE | ID: mdl-34102172

ABSTRACT

Early and late outcomes of patients undergoing multiple-valve procedures are better if all valves are repaired. Aortic/mitral multiple-valve repair has been limited by an inability to repair the more complex forms of aortic valve insufficiency. With the development of aortic ring annuloplasty 90% to 95% of aortic valve insufficiency pathologies now can be repaired, which opens most aortic/mitral multiple-valve procedures to the better repair outcomes. This report illustrates 4 cases of aortic/mitral ± tricuspid valve disease managed by multiple-valve repair.


Subject(s)
Aortic Valve Insufficiency , Cardiac Valve Annuloplasty , Heart Valve Diseases , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Cardiac Valve Annuloplasty/methods , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/methods , Humans , Mitral Valve Insufficiency/surgery , Treatment Outcome , Tricuspid Valve/surgery
19.
J Card Surg ; 36(9): 3040-3051, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34118080

ABSTRACT

BACKGROUND: The coronavirus disease 2019 (COVID-19) pandemic has had an unprecedented impact on health care and cardiac surgery. We report cardiac surgeons' concerns, perceptions, and responses during the COVID-19 pandemic. METHODS: A detailed survey was sent to recruit participating adult cardiac surgery centers in North America. Data regarding cardiac surgeons' perceptions and changes in practice were analyzed. RESULTS: Our study comprises 67 institutions with diverse geographic distribution across North America. Nurses were most likely to be redeployed (88%), followed by advanced care practitioners (69%), trainees (28%), and surgeons (25%). Examining surgeon concerns in regard to COVID-19, they were most worried with exposing their family to COVID-19 (81%), followed by contracting COVID-19 (68%), running out of personal protective equipment (PPE) (28%), and hospital resources (28%). In terms of PPE conservation strategies among users of N95 respirators, nearly half were recycling via decontamination with ultraviolet light (49%), followed by sterilization with heat (13%) and at home or with other modalities (13%). Reuse of N95 respirators for 1 day (22%), 1 week (21%) or 1 month (6%) was reported. There were differences in adoption of methods to conserve N95 respirators based on institutional pandemic phase and COVID-19 burden, with higher COVID-19 burden institutions more likely to resort to PPE conservation strategies. CONCLUSIONS: The present study demonstrates the impact of COVID-19 on North American cardiac surgeons. Our study should stimulate further discussions to identify optimal solutions to improve workforce preparedness for subsequent surges, as well as facilitate the navigation of future healthcare crises.


Subject(s)
COVID-19 , Surgeons , Adult , Decontamination , Humans , Pandemics , Perception , SARS-CoV-2
20.
J Surg Res ; 262: 21-26, 2021 06.
Article in English | MEDLINE | ID: mdl-33530005

ABSTRACT

BACKGROUND: Previous reports of extracellular matrix (ECM) patch use after carotid endarterectomy (CEA) have noted an approximately 10% rate of pseudoaneurysm (PSA) formation. PSA-related rupture of ECM patches has also been described after femoral artery repair. In these studies, different thicknesses (4-ply versus 6-ply) and no standard length of soaking the patch in saline before implantation were used. Herein, we describe our experience with ECM CorMatrix patches in 291 CEAs with 6-ply patches. METHODS: The records of 275 consecutive patients undergoing 291 CEAs with CorMatrix 6-ply patches beginning in November of 2011 and extending until 2015 were reviewed. Only 6-ply patches and a 1 min hydration time in saline were used in all patients. No shunts were used. RESULTS: There were three deaths within the first 30 d secondary to subsequent cardiac surgical procedures. Nine patients experienced a perioperative stroke (3.1%), only one of which occurred secondary to an occluded internal carotid artery. One patient had a transient ischemic attack with a patent endarterectomy site. In follow-up, 11 patients (4.5%) developed severe recurrent stenoses requiring reintervention. Only one patient (0.34%) developed a PSA at 2 years possibly secondary to chronic infection. The median follow-up was 72 mo. CONCLUSIONS: Our experience with 6-ply CorMatrix ECM patches and a brief period of soaking demonstrated that these patches performed well in patients requiring a CEA. Only one PSA was noted.


Subject(s)
Bioprosthesis/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Carotid Artery Injuries/etiology , Endarterectomy, Carotid/adverse effects , Extracellular Matrix , Postoperative Complications/etiology , Aged , Aged, 80 and over , Endarterectomy, Carotid/methods , Female , Humans , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...