Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
Add more filters










Publication year range
1.
Int J Biomed Imaging ; 2024: 9763364, 2024.
Article in English | MEDLINE | ID: mdl-38644981

ABSTRACT

Background: Ferumoxytol (Ferahame, AMAG Pharmaceuticals, Waltham, MA) is increasingly used off-label as an MR contrast agent due to its relaxivity and safety profiles. However, its potent T2∗ relaxivity limits achievable T1-weighted positive contrast and leads to artifacts in standard MRI protocols. Optimization of protocols for ferumoxytol deployment is necessary to realize its potential. Methods: We present first-in-human clinical results of the Quantitative Ultrashort Time-to-Echo Contrast Enhanced (QUTE-CE) MRA technique using the superparamagnetic iron oxide nanoparticle agent ferumoxytol for vascular imaging of the head/brain in 15 subjects at 3.0T. The QUTE-CE MRA method was implemented on a 3T scanner using a stack-of-spirals 3D Ultrashort Time-to-Echo sequence. Time-of-flight MRA and standard TE T1-weighted (T1w) images were also collected. For comparison, gadolinium-enhanced blood pool phase images were obtained retrospectively from clinical practice. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and intraluminal signal heterogeneity (ISH) were assessed and compared across approaches with Welch's two-sided t-test. Results: Fifteen volunteers (54 ± 17 years old, 9 women) participated. QUTE-CE MRA provided high-contrast snapshots of the arterial and venous networks with lower intraluminal heterogeneity. QUTE-CE demonstrated significantly higher SNR (1707 ± 226), blood-tissue CNR (1447 ± 189), and lower ISH (0.091 ± 0.031) compared to ferumoxytol T1-weighted (551 ± 171; 319 ± 144; 0.186 ± 0.066, respectively) and time-of-flight (343 ± 104; 269 ± 82; 0.190 ± 0.016, respectively), with p < 0.001 in each comparison. The high CNR increased the depth of vessel visualization. Vessel lumina were captured with lower heterogeneity. Conclusion: Quantitative Ultrashort Time-to-Echo Contrast-Enhanced MR angiography provides approximately 5-fold superior contrast with fewer artifacts compared to other contrast-enhanced vascular imaging techniques using ferumoxytol or gadolinium, and to noncontrast time-of-flight MR angiography, for clinical vascular imaging. This trial is registered with NCT03266848.

3.
Front Neurosci ; 15: 763780, 2021.
Article in English | MEDLINE | ID: mdl-34887724

ABSTRACT

Ferumoxytol, an iron oxide nanoparticle, was infused into the lateral cerebroventricle of awake rats to follow its movement and clearance from the brain using magnetic resonance imaging. Within minutes the contrast agent could be observed accumulating in the subarachnoid space, nasal cavity, nasal pharynx, and soft palate at the back of the throat. In a subsequent study fluorescent quantum dots were infused into the brain of rats and within 15 min could be observed in the esophagus using microscopy. These imaging studies clearly show that these large nanoparticle tracers (∼20 nm in diameter) leave the brain through the nasal cavity and end up in the gut. There are numerous studies going back decades reporting the clearance of tracers put directly into the brain. While these studies show the slow accumulation of trace in the blood and lymphatics, they report only accounting for less than 50% of what was originally put in the brain.

4.
Front Neurol ; 12: 729464, 2021.
Article in English | MEDLINE | ID: mdl-34659094

ABSTRACT

This was an exploratory study designed to evaluate the feasibility of a recently established imaging modality, quantitative ultrashort time-to-echo contrast enhanced (QUTE-CE), to follow the early pathology and vulnerability of the blood brain barrier in response to single and repetitive mild head impacts. A closed-head, momentum exchange model was used to produce three consecutive mild head impacts aimed at the forebrain separated by 24 h each. Animals were measured at baseline and within 1 h of impact. Anatomical images were collected to assess the extent of structural damage. QUTE-CE biomarkers for BBB permeability were calculated on 420,000 voxels in the brain and were registered to a bilateral 3D brain atlas providing site-specific information on 118 anatomical regions. Blood brain barrier permeability was confirmed by extravasation of labeled dextran. All head impacts occurred in the absence of any structural brain damage. A single mild head impact had measurable effects on blood brain barrier permeability and was more significant after the second and third impacts. Affected regions included the prefrontal ctx, basal ganglia, hippocampus, amygdala, and brainstem. Our findings support the concerns raised by the healthcare community regarding mild head injuries in participants in organized contact sports and military personnel in basic training and combat.

5.
PLoS One ; 16(8): e0256749, 2021.
Article in English | MEDLINE | ID: mdl-34449808

ABSTRACT

Cerebrovascular abnormality is linked to Alzheimer's disease and related dementias (ADRDs). ApoE-Ɛ4 (APOE4) is known to play a critical role in neurovascular dysfunction, however current medical imaging technologies are limited in quantification. This cross-sectional study tested the feasibility of a recently established imaging modality, quantitative ultra-short time-to-echo contrast-enhanced magnetic resonance imaging (QUTE-CE MRI), to identify small vessel abnormality early in development of human APOE4 knock-in female rat (TGRA8960) animal model. At 8 months, 48.3% of the brain volume was found to have significant signal increase (75/173 anatomically segmented regions; q<0.05 for multiple comparisons). Notably, vascular abnormality was detected in the tri-synaptic circuit, cerebellum, and amygdala, all of which are known to functionally decline throughout AD pathology and have implications in learning and memory. The detected abnormality quantified with QUTE-CE MRI is likely a result of hyper-vascularization, but may also be partly, or wholly, due to contributions from blood-brain-barrier leakage. Further exploration with histological validation is warranted to verify the pathological cause. Regardless, these results indicate that QUTE-CE MRI can detect neurovascular dysfunction with high sensitivity with APOE4 and may be helpful to provide new insights into health and disease.


Subject(s)
Apolipoprotein E4/genetics , Blood-Brain Barrier/diagnostic imaging , Brain/abnormalities , Animals , Blood-Brain Barrier/pathology , Brain/blood supply , Brain/diagnostic imaging , Disease Models, Animal , Gene Knock-In Techniques , Humans , Magnetic Resonance Imaging , Rats
7.
Alzheimers Dement (Amst) ; 12(1): e12088, 2020.
Article in English | MEDLINE | ID: mdl-33088894

ABSTRACT

INTRODUCTION: Novel sensors were developed to detect exhaled volatile organic compounds to aid in the diagnosis of mild cognitive impairment associated with early stage Alzheimer's disease (AD). The sensors were sensitive to a rat model that combined the human apolipoprotein E (APOE)4 gene with aging and the Western diet. METHODS: Gas sensors fabricated from molecularly imprinted polymer-graphene were engineered to react with alkanes and small fatty acids associated with lipid peroxidation. With a detection sensitivity in parts per trillion the sensors were tested against the breath of wild-type and APOE4 male rats. Resting state BOLD functional connectivity was used to assess hippocampal function. RESULTS: Only APOE4 rats, and not wild-type controls, tested positive to several small hydrocarbons and presented with reduced functional coupling in hippocampal circuitry. DISCUSSION: These results are proof-of-concept toward the development of sensors that can be used as breath detectors in the diagnosis, prognosis, and treatment of presymptomatic AD.

8.
Eur J Nucl Med Mol Imaging ; 46(10): 2099-2111, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31332496

ABSTRACT

PURPOSE: [18F]MK6240 was developed for PET imaging of tau aggregates, which are implicated in Alzheimer's disease. The goal of this work was to evaluate the kinetics of [18F]MK6240 and to investigate different strategies for in-vivo quantification of tau aggregates in humans. METHODS: Thirty-five subjects, consisting of 18 healthy controls (CTRL), 11 subjects with mild cognitive impairment (MCI) and six with Alzheimer's Disease (AD), underwent dynamic [18F]MK6240 PET scans. Arterial blood measurements were collected in 16 subjects (eight CTRLs, six MCIs and two AD) to measure whole blood and plasma concentration time courses. Radiometabolite analysis was performed on a subset of plasma samples. Various compartmental model configurations as well as the Logan and multilinear analysis (MA1) graphical methods with arterial plasma input function were tested. Simplified reference tissue methods were investigated, including Logan distribution volume ratio (DVR), multilinear reference tissue method (MRTM2), and static SUV ratio using the cerebellum as a reference region. RESULTS: Whole blood:plasma ratio stabilized to 0.66 ± 0.01 after 15 min. Percent parent in plasma (%PP) followed a single exponential and ranged from 0 to 10% at 90 min. [18F]MK6240 in gray matter peaked quickly (SUV > 2 at ~3 min). The preferred compartmental model was a reversible two-tissue compartment model, with the blood contribution included as a model parameter (2T4k1v). Compartmental and graphical analysis methods with arterial input functions yielded concordant results, but rapid metabolism raised challenges for blood-based quantification. MCI and AD subjects demonstrated a broad range of VT as compared to CTRL subjects. DVR from MRTM2 and Logan reference tissue methods correlated with DVR calculated indirectly from compartmental modeling, but underestimation was observed in data sets with very high binding (DVR > 3). SUVR also underestimated indirect DVR from blood-based analyses in high binding regions, although a non-linear relationship was exhibited. CONCLUSIONS: [18F]MK6240 exhibited a wide dynamic range of uptake, with binding patterns in MCI/AD subjects consistent with neurofibrillary tau deposition patterns. Linearized reference tissue methods using an estimated average tissue-to-plasma efflux constant [Formula: see text] and static SUVR agreed well with blood-based methods for most data sets; however, discrepancies were noted in the highest binding cases. Caution should therefore be exercised in application of simplified methods to such data sets, and in quantitative interpretation of corresponding outcomes.


Subject(s)
Alzheimer Disease/diagnostic imaging , Cognitive Dysfunction/diagnostic imaging , Isoquinolines/pharmacokinetics , Positron-Emission Tomography/methods , Radiopharmaceuticals/pharmacokinetics , tau Proteins/metabolism , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Models, Theoretical , Positron-Emission Tomography/standards
9.
Data Brief ; 17: 393-396, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29876407

ABSTRACT

The data in this article provide detail regarding the rat brain atlas measurements discussed in our research article, "Quantitative vascular neuroimaging of the rat brain using superparamagnetic nanoparticles: New insights on vascular organization and brain function" (Gharagouzloo et al., 2017) [1]. This article provides datasets of quantitative cerebral blood volume (qCBV) measurements across 173 regions of the rat brain in 11 healthy rats. State-changes from this baseline during isoflurane and CO2 administration are provided for all regions and all animals.

10.
Neuroimage ; 163: 24-33, 2017 12.
Article in English | MEDLINE | ID: mdl-28889004

ABSTRACT

A method called Quantitative Ultra-Short Time-to-Echo Contrast Enhanced (QUTE-CE) Magnetic Resonance Imaging (MRI) which utilizes superparamagnetic iron oxide nanoparticles (SPIONs) as a contrast agent to yield positive contrast angiograms with high clarity and definition is applied to the whole live rat brain. QUTE-CE MRI intensity data are particularly well suited for measuring quantitative cerebral blood volume (qCBV). A global map of qCBV in the awake resting-state with unprecedented detail was created via application of a 3D MRI rat brain atlas with 173 segmented and annotated brain areas. From this map we identified two distributed, integrated neural circuits showing the highest capillary densities in the brain. One is the neural circuitry involved with the primary senses of smell, hearing and vision and the other is the neural circuitry of memory. Under isoflurane anesthesia, these same circuits showed significant decreases in qCBV suggesting a role in consciousness. Neural circuits in the brainstem associated with the reticular activating system and the maintenance of respiration, body temperature and cardiovascular function showed an increase in qCBV with anesthesia. During awake CO2 challenge, 84 regions showed significant increases relative to an awake baseline state. This CO2 response provides a measure of cerebral vascular reactivity and regional perfusion reserve with the highest response measured in the somatosensory cortex. These results demonstrate the utility of QUTE-CE MRI for qCBV analysis and offer a new perspective on brain function and vascular organization.


Subject(s)
Brain Mapping/methods , Brain/blood supply , Brain/diagnostic imaging , Cerebral Angiography/methods , Magnetite Nanoparticles , Animals , Blood Volume/physiology , Blood Volume Determination/methods , Cerebrovascular Circulation/physiology , Ferric Compounds , Magnetic Resonance Imaging/methods , Rats , Rats, Sprague-Dawley
11.
Sci Rep ; 7(1): 7850, 2017 08 10.
Article in English | MEDLINE | ID: mdl-28798327

ABSTRACT

Stem cell tracking in cellular therapy and regenerative medicine is an urgent need, superparamagnetic iron oxide nanoparticles (IONPs) could be used as contrast agents in magnetic resonance imaging (MRI) that allows visualization of the implanted cells ensuring they reach the desired sites in vivo. Herein, we report the study of the interaction of 3,4-dihydroxyhydrocinnamic acid (DHCA) functionalized IONPs that have desirable properties for T2 - weighted MRI, with bone marrow-derived primary human mesenchymal stem cells (hMSCs). Using the multiparametric high-content imaging method, we evaluate cell viability, formation of reactive oxygen species, mitochondrial health, as well as cell morphology and determine that the hMSCs are minimally affected after labelling with IONPs. Their cellular uptake is visualized by transmission electron microscopy (TEM) and Prussian Blue staining, and quantified using an iron specific colourimetric method. In vitro and in vivo studies demonstrate that these IONPs are biocompatible and can produce significant contrast enhancement in T2-weighted MRI. Iron oxide nanoparticles are detected in vivo as hypointense regions in the liver up to two weeks post injection using 9.4 T MRI. These DHCA functionalized IONPs are promising contrast agents for stem cell tracking by T2-weighted MRI as they are biocompatible and show no evidence of cytotoxic effects on hMSCs.


Subject(s)
Cell Tracking/methods , Contrast Media/metabolism , Ferric Compounds/metabolism , Intravital Microscopy/methods , Magnetic Resonance Imaging/methods , Mesenchymal Stem Cells/metabolism , Nanoparticles/metabolism , Cell Shape/drug effects , Cell Survival/drug effects , Colorimetry , Contrast Media/toxicity , Ferric Compounds/toxicity , Humans , Mesenchymal Stem Cells/cytology , Mesenchymal Stem Cells/physiology , Microscopy, Electron, Transmission , Mitochondria/drug effects , Mitochondria/physiology , Nanoparticles/toxicity , Reactive Oxygen Species/analysis , Staining and Labeling/methods
12.
Mol Cancer Ther ; 16(7): 1279-1289, 2017 07.
Article in English | MEDLINE | ID: mdl-28500233

ABSTRACT

The use of PARP inhibitors in combination with radiotherapy is a promising strategy to locally enhance DNA damage in tumors. Here we show that radiation-resistant cells and tumors derived from a Pten/Trp53-deficient mouse model of advanced prostate cancer are rendered radiation sensitive following treatment with NanoOlaparib, a lipid-based injectable nanoformulation of olaparib. This enhancement in radiosensitivity is accompanied by radiation dose-dependent changes in γ-H2AX expression and is specific to NanoOlaparib alone. In animals, twice-weekly intravenous administration of NanoOlaparib results in significant tumor growth inhibition, whereas previous studies of oral olaparib as monotherapy have shown no therapeutic efficacy. When NanoOlaparib is administered prior to radiation, a single dose of radiation is sufficient to triple the median mouse survival time compared to radiation only controls. Half of mice treated with NanoOlaparib + radiation achieved a complete response over the 13-week study duration. Using ferumoxytol as a surrogate nanoparticle, MRI studies revealed that NanoOlaparib enhances the intratumoral accumulation of systemically administered nanoparticles. NanoOlaparib-treated tumors showed up to 19-fold higher nanoparticle accumulation compared to untreated and radiation-only controls, suggesting that the in vivo efficacy of NanoOlaparib may be potentiated by its ability to enhance its own accumulation. Together, these data suggest that NanoOlaparib may be a promising new strategy for enhancing the radiosensitivity of radiation-resistant tumors lacking BRCA mutations, such as those with PTEN and TP53 deletions. Mol Cancer Ther; 16(7); 1279-89. ©2017 AACR.


Subject(s)
PTEN Phosphohydrolase/genetics , Phthalazines/administration & dosage , Piperazines/administration & dosage , Prostatic Neoplasms/drug therapy , Tumor Suppressor Protein p53/genetics , Animals , BRCA1 Protein/genetics , Cell Line, Tumor , Disease Models, Animal , Humans , Male , Mice , Nanostructures/administration & dosage , Nanostructures/chemistry , PTEN Phosphohydrolase/deficiency , Phthalazines/chemistry , Piperazines/chemistry , Poly(ADP-ribose) Polymerase Inhibitors/administration & dosage , Prostatic Neoplasms/genetics , Prostatic Neoplasms/pathology , Prostatic Neoplasms/radiotherapy , Radiation Tolerance/drug effects , Tumor Suppressor Protein p53/deficiency , Xenograft Model Antitumor Assays
13.
Magn Reson Med ; 74(2): 431-41, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25168606

ABSTRACT

PURPOSE: Conventional MRI using contrast agents is semiquantitative because it is inherently sensitive to extravoxular susceptibility artifacts, field inhomogeneity, partial voluming, perivascular effects, and motion/flow artifacts. Herein we demonstrate a quantitative contrast-enhanced MRI technique using ultrashort time-to-echo pulse sequences for measuring clinically relevant concentrations of ferumoxytol, a superparamagnetic iron oxide nanoparticle contrast agent with high sensitivity and precision in vitro and in vivo. METHODS: The method achieves robust, reproducible results by using rapid signal acquisition at ultrashort time-to-echo (UTE) to produce positive contrast images with pure T1 weighting and little T2* decay. The spoiled gradient echo equation is used to transform UTE intensities directly into concentration using experimentally determined relaxivity constants and image acquisition parameters. RESULTS: A multiparametric optimization of acquisition parameters revealed an optimal zone capable of producing high-fidelity measurements. Clinically relevant intravascular concentrations of ferumoxytol were measured longitudinally in mice with high sensitivity and precision (∼7.1% error). MRI measurements were independently validated by elemental iron analysis of sequential blood draws. Automated segmentation of ferumoxytol concentration yielded high quality three-dimensional images for visualization of perfusion. CONCLUSIONS: This ability to longitudinally quantify blood pool CA concentration is unique to quantitative UTE contrast-enhanced (QUTE-CE) MRI and makes QUTE-CE MRI competitive with nuclear imaging.


Subject(s)
Algorithms , Ferrosoferric Oxide/administration & dosage , Image Enhancement/methods , Magnetic Resonance Imaging/methods , Signal Processing, Computer-Assisted , Whole Body Imaging/methods , Animals , Contrast Media/administration & dosage , Dose-Response Relationship, Drug , Mice , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...