Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Pacing Clin Electrophysiol ; 46(9): 1049-1055, 2023 09.
Article in English | MEDLINE | ID: mdl-37527153

ABSTRACT

BACKGROUND: Intermittent ventricular pre-excitation was considered a low-risk marker for sudden death. However, to date, some studies do not exclude the existence of accessory pathways (APs) with high-risk intermittent antegrade conductive properties. According to current European Guidelines, high-risk features of APs are antegrade pathway conduction ≤250 ms in baseline or during the adrenergic stimulus, inducibility of atrioventricular reciprocating tachycardias (AVRT), inducibility of pre-excited atrial fibrillation (AF), and presence of multiple APs. For all of these transcatheter ablation is recommended. The aim of our study was to evaluate the existence of differences in risk characteristics between patients with intermittent pre-excitation (IPX) and those with persistent pre-excitation (PPX), from a sample of adults with ventricular pre-excitation and symptoms like palpitations. METHODS: 293 adults [IPX: 51 (17.4%); PPX: 242 (82.6%)] underwent electrophysiological study and then catheter ablation of their APs if arrhythmia inducibility (AVRT/AF) was noted, or, conversely, if it was appreciated a fast AP antegrade conduction, in baseline or during intravenous isoproterenol infusion, or if multiple APs were detected. RESULTS: There were no statistically significant differences in demographic characteristics (age and gender), AVRT/AF inducibility, antegrade conductive properties, the prevalence of multiple APs, and APs locations between IPX and PPX patients. CONCLUSIONS: In our study, patients with IPX did not show significant differences in clinical and electrophysiological features versus PPX patients.


Subject(s)
Accessory Atrioventricular Bundle , Atrial Fibrillation , Catheter Ablation , Pre-Excitation Syndromes , Wolff-Parkinson-White Syndrome , Humans , Adult , Accessory Atrioventricular Bundle/surgery , Atrial Fibrillation/surgery , Risk Factors , Electrocardiography
2.
Future Cardiol ; 18(8): 621-626, 2022 08.
Article in English | MEDLINE | ID: mdl-35735185

ABSTRACT

The COVID-19 pandemic has seriously revolutionized the management of patients who need an implanted cardiac implantable electronic device. We report, for the first time, a successful cardiac resynchronization therapy defibrillator implantation procedure in an 82-year-old man affected by COVID-19, recent myocardial infarction, second-degree 2:1 atrioventricular block and left bundle branch block.


Subject(s)
COVID-19 , Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Aged, 80 and over , COVID-19/therapy , Cardiac Resynchronization Therapy/methods , Electric Countershock/methods , Heart Failure/complications , Heart Failure/therapy , Humans , Male , Pandemics , Treatment Outcome
3.
J Cardiovasc Electrophysiol ; 33(8): 1874-1879, 2022 08.
Article in English | MEDLINE | ID: mdl-35695789

ABSTRACT

BACKGROUND: Fever is a potential side effect of the Covid-19 vaccination. Patients with Brugada syndrome (BrS) have an increased risk of life-threatening arrhythmias when experiencing fever. Prompt treatment with antipyretic drugs is suggested in these patients. AIM OF THE STUDY: To evaluate the incidence and management of fever within 48 h from Covid-19 vaccination among BrS patients. METHODS: One hundred sixty-three consecutive patients were enrolled in a prospective registry involving five European hospitals with a dedicated inherited disease ambulatory. RESULTS: The mean age was 50 ± 14 years and 121 (75%) patients were male. Prevalence of Brugada electrocardiogram (ECG) pattern type-1, -2, and -3 was 32%, 44%, and 24%, respectively. Twenty-eight (17%) patients had an implantable cardioverter-defibrillator (ICD). Fever occurred in 32 (19%) BrS patients after 16 ± 10 h from vaccination, with a peak of body temperature of 37.9° ± 0.5°. Patients with fever were younger (39 ± 13 vs. 48 ± 13 years, p = .04). No additional differences in terms of sex and cardiovascular risk factors were found between patients with fever and not. Twenty-seven (84%) out of 32 patients experienced mild fever and five (16%) moderate fever. Pharmacological treatment with antipyretic drugs was required in 18 (56%) out of 32 patients and was associated with the resolution of symptoms. No patient required hospital admission and no arrhythmic episode was recorded in patients with ICD within 48 h after vaccination. No induced type 1 BrS ECG pattern and new ECG features were found among patients with moderate fever. CONCLUSION: Fever is a common side effect in BrS patients after the Covid-19 vaccination. Careful evaluation of body temperature and prompt treatment with antipyretic drugs may be needed.


Subject(s)
Antipyretics , Brugada Syndrome , COVID-19 Vaccines , COVID-19 , Defibrillators, Implantable , Adult , Antipyretics/adverse effects , Brugada Syndrome/diagnosis , Brugada Syndrome/epidemiology , Brugada Syndrome/therapy , COVID-19/epidemiology , COVID-19/prevention & control , COVID-19 Vaccines/adverse effects , Electrocardiography , Female , Fever/chemically induced , Fever/diagnosis , Fever/epidemiology , Humans , Incidence , Male , Middle Aged , Vaccination/adverse effects
4.
J Electrocardiol ; 72: 95-97, 2022.
Article in English | MEDLINE | ID: mdl-35398737

ABSTRACT

A 51-year-old man with Brugada syndrome (BrS) electrocardiogram (ECG) type I pattern underwent implantable cardiac monitor (ICM) insertion. After pre-insertion potential mapping, we could observe the patient-specific repolarization abnormalities on the subcutaneous ECG provided by the ICM. A few weeks later, we received remotely a device recording with a higher ST-segment elevation and a longer duration of the interval between the onset of the coved elevation and its termination at the isoelectric line. Our observation supports the conceptual premise that ICM could add information on quantifying the amount of time with abnormal ECG patterns rather than only for the diagnosis of cardiac arrhythmias.


Subject(s)
Brugada Syndrome , Electrocardiography , Arrhythmias, Cardiac , Brugada Syndrome/diagnosis , Humans , Male , Middle Aged
5.
J Cardiol Cases ; 25(1): 26-29, 2022 Jan.
Article in English | MEDLINE | ID: mdl-35024064

ABSTRACT

Inadvertent placement of pacemaker and implantable cardioverter-defibrillator (ICD) leads in the left ventricle is a rare but well-recognized complication of device implantation. We report a case of an unicameral ICD lead inadvertently placed through the left subclavian artery right positioned, across the aortic valve into the left ventricle, in a patient with situs viscerum inversus. A transthoracic echocardiogram about a month after the procedure showed an unusual course of the lead. The lead was successfully removed without complications or sequelae. .

SELECTION OF CITATIONS
SEARCH DETAIL
...