Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Med ; 13(6)2024 Mar 13.
Article in English | MEDLINE | ID: mdl-38541858

ABSTRACT

Background: Scientific literature lacks strong support for using narrow diameter implants (NDI) in high masticatory force areas, especially in molars. Implant splinting in cases of multiple missing teeth reduces lateral forces, improves force distribution, and minimizes stress on implants. However, no studies have evaluated the fatigue load resistance of unitary or splinted implants. Methods: This in vitro study compares five groups of new metal alloy implants, including unitary and splinted implants with varying diameters. Mechanical characterization was assessed using a BIONIX 370 testing machine (MTS, Minneapolis, MN, USA) according to ISO 14801. For each of the five study sample groups, (n = 5) specimens underwent monotonic uniaxial compression at break testing and (n = 15) cyclic loading to determine the maximum force (Fmax) and the fatigue life (LF) values. Scanning electron microscopy (SEM) was employed for the fractographic analysis of the fractured samples. Results: The Fmax values for unitary samples ranged from 196 N to 246 N, whereas the two-splinted samples displayed significantly higher values, ranging from 2439 N to 3796 N. Similarly, the LF values for unitary samples ranged from 118 N to 230 N, while the two-splinted samples exhibited notably higher values, ranging from 488 N to 759 N. Conclusions: The observed resistance difference between sample groups in terms of Fmax and LF may be due to variations in effective cross-sectional area, determined by implant diameter and number. Additionally, this disparity may indicate a potential stiffening effect resulting from the splinting process. These findings have significant implications for dental clinical practice, suggesting the potential use of splinted sets of small-sized NDI as replacements for posterior dentition (premolars and molars) in cases of alveolar bone ridge deficiencies.

2.
Materials (Basel) ; 17(4)2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38399026

ABSTRACT

A postextraction socket becomes a clinical challenge due to the fact that a series of changes associated with bone remodelling and resorption of the socket that occur after extraction, which limits the aesthetic and functional prognosis of implant-supported rehabilitations. It has been studied that the use of the autologous tooth-derived graft (ATDG) has regenerative properties and could therefore be useful for solving this type of problem. There is no consensus in the scientific literature on a standardized protocol for the use of the autologous tooth. Therefore, the aim of the present study was to evaluate the most relevant parameters to achieve the best properties of ground ATDG using three methods, namely Gouge forceps, electric grinder, and manual, that made up the study group (SG) and compared with the control group (CG) consisting of Bio-Oss®. The sample obtained by the electric grinder had the highest value of specific surface area (2.4025 ± 0.0218 m2/g), while the particle size as average diameter (751.9 µm) was the lowest and most homogeneous of the three groups. Therefore, the electric grinder allowed for obtaining ATDG with more regenerative properties due to its specific surface-area value and particle size in accordance with the xenograft with the greatest bibliographical support (Bio-Oss®). The higher specific surface increases the reaction with the physiological media, producing faster biological mechanisms.

3.
Materials (Basel) ; 13(9)2020 May 08.
Article in English | MEDLINE | ID: mdl-32397319

ABSTRACT

The use of individualized titanium meshes has been referred to in scientific literature since 2011. There are many advantages to its use, however, the main complications are related to early or late exposures. As some aspects such as its surface properties have been pointed out to influence the soft tissue response, this study was designed to compare the surface characteristics of three commercially available individualized titanium meshes between them and according to the manufacturer's specifications. The results from the scanning electron microscopy, energy-dispersive X-ray spectroscopy, X-ray diffraction and the contact profilometry measurements were analyzed and cross-checked. It was discovered that, the BoneEasy's post-processing superficial treatment was more refined, as it delivers the mesh with the lowest Ra value, 0.61 ± 0.14 µm, due to the applied electropolishing. On the other hand, the Yxoss CBR® mesh from ReOss® was sandblasted, presenting an extremely rough surface with a Ra of 6.59 ± 0.76 µm.

4.
Materials (Basel) ; 12(6)2019 Mar 25.
Article in English | MEDLINE | ID: mdl-30934553

ABSTRACT

The load transfer from metallic prosthesis to tissue plays an important role in the success of a designed device. From a mechanical behavior point of view, the load transfer will be favored when the elastic modulus between the metallic implant and the bone tissue are similar. Titanium and Ti-6Al-4V are the most commonly used metals and alloys in the field of dental implants, although they present high elastic moduli and hence trigger bone resorption. We propose the use of low-modulus ß-type titanium alloys that can improve the growth of new bone surrounding the implant. We designed dental implants with identical morphology and micro-roughness composed of: Ti-15Zr, Ti-19.1Nb-8.8Zr, Ti-41.2Nb-6.1Zr, and Ti-25Hf-25Ta. The commercially pure Ti cp and Ti-6Al-4V were used as control samples. The alloys were initially mechanically characterized with a tensile test using a universal testing machine. The results showed the lowest elastic modulus for the Ti-25Hf-25Ta alloy. We implanted a total of six implants in the mandible (3) and maxilla (3) for each titanium alloy in six minipigs and evaluated their bone index contact (i.e., the percentage of new bone in contact with the metal-BIC%) after 3 and 6 weeks of implantation. The results showed higher BIC% for the dental implants with lowest elastic modulus, showing the importance of decreasing the elastic modulus of alloys for the successful osseointegration of dental implants.

SELECTION OF CITATIONS
SEARCH DETAIL
...