Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 42
Filter
1.
Analyst ; 149(9): 2600-2608, 2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38529879

ABSTRACT

A new analytical method for chronic kidney disease (CKD) detection utilizing paper spray mass spectrometry (PS-MS) combined with machine learning is presented. The analytical protocol is rapid and simple, based on metabolic profile alterations in urine. Anonymized raw urine samples were deposited (10 µL each) onto pointed PS-MS sample strips. Without waiting for the sample to dry, 75 µL of acetonitrile and high voltage were applied to the strips, using high resolution mass spectrometry measurement (15 s per sample) with polarity switching to detect a wide range of metabolites. Random forest machine learning was used to classify the resulting data. The diagnostic performance for the potential diagnosis of CKD was evaluated for accuracy, sensitivity, and specificity, achieving results >96% for the training data and >91% for validation and test data sets. Metabolites selected by the classification model as up- or down-regulated in healthy or CKD samples were tentatively identified and in agreement with previously reported literature. The potential utilization of this approach to discriminate albuminuria categories (normo, micro, and macroalbuminuria) was also demonstrated. This study indicates that PS-MS combined with machine learning has the potential to be used as a rapid and simple diagnostic tool for CKD.


Subject(s)
Machine Learning , Mass Spectrometry , Renal Insufficiency, Chronic , Renal Insufficiency, Chronic/diagnosis , Renal Insufficiency, Chronic/urine , Humans , Mass Spectrometry/methods , Paper , Albuminuria/diagnosis , Albuminuria/urine , Rapid Diagnostic Tests
2.
Analyst ; 149(4): 1102-1110, 2024 Feb 12.
Article in English | MEDLINE | ID: mdl-38093632

ABSTRACT

Albuminuria is a clinical condition associated with poor kidney function, diagnosed by determining the ratio of albumin to creatinine concentrations in patient urine samples. We present a high-throughput paper spray mass spectrometry (PS-MS) method for simultaneous quantitation of urinary albumin and creatinine for potential diagnosis of albuminuria. Minimal (urine dilution) or no sample preparation is required. The analytical performance of the method was evaluated, achieving linear calibration curves (R2 > 0.99) with little inter-day variability in the slope (N = 5 days), exhibiting coefficient of variation (CV) of 8% and 3% for albumin and creatinine, respectively. LOD and LOQ for albumin were 2.1 and 7.0 mg L-1, and for creatinine were 0.01 and 0.03 mmol L-1, respectively. Intra- and inter-day (N = 5) precisions (%CV) and accuracies (%bias) were <10% and ±11%, respectively, for both analytes. The method was applied to determine albumin-to-creatinine ratios in anonymous human patient urine samples (N = 56), and a correlation of R2 = 0.9744 was achieved between the PS-MS results and validated clinical method results. This work demonstrates the utility of PS-MS to simultaneously quantify a large (albumin) and a small (creatinine) molecule directly in patient urine samples, and its potential as a tool for clinical albuminuria diagnostics.


Subject(s)
Albuminuria , Kidney , Humans , Albuminuria/diagnosis , Creatinine/urine , Urinalysis , Tandem Mass Spectrometry/methods
3.
Environ Sci Process Impacts ; 25(7): 1169-1180, 2023 Jul 19.
Article in English | MEDLINE | ID: mdl-37313682

ABSTRACT

Microplastics are environmentally ubiquitous and their role in the fate and distribution of trace contaminants is of emerging concern. We report the first use of membrane introduction mass spectrometry to directly monitor the rate and extent of microplastic-contaminant sorption. Target contaminant (naphthalene, anthracene, pyrene, and nonylphenol) sorption behaviours were examined at nanomolar concentrations with four plastic types: low density polyethylene (LDPE), high density polyethylene (HDPE), polypropylene (PP), and polystyrene (PS). Under the conditions employed here, short-term sorption kinetics were assessed using on-line mass spectrometry for up to one hour. Subsequent sorption was followed by periodically measuring contaminant concentrations for up to three weeks. Short-term sorption followed first order kinetics with rate constants that scaled with hydrophobicity for the homologous series of polycyclic aromatic hydrocarbons (PAHs). Sorption rate constants on LDPE for equimolar solutions of naphthalene, anthracene, and pyrene were 0.5, 2.0, and 2.2 h-1, respectively, while nonylphenol did not sorb to pristine plastics over this time period. Similar trends among contaminants were observed for other pristine plastics with 4- to 10-fold faster sorption rates associated with LDPE when compared to PS and PP. Sorption was largely complete after three weeks, with the percent analyte sorbed ranging from 40-100% across various microplastic-contaminant combinations. Photo-oxidative ageing of LDPE had little effect on PAH sorption. However, a marked increase in nonylphenol sorption was consistent with increased hydrogen-bonding interactions. This work provides kinetic insights into surface interactions and describes a powerful experimental platform to directly observe contaminant sorption behaviours in complex samples under a variety of environmentally relevant conditions.


Subject(s)
Plastics , Water Pollutants, Chemical , Plastics/analysis , Microplastics , Polyethylene , Adsorption , Water Pollutants, Chemical/analysis , Naphthalenes/analysis , Pyrenes/analysis , Polystyrenes/chemistry , Polypropylenes , Mass Spectrometry , Anthracenes/analysis
4.
Anal Chem ; 95(18): 7134-7141, 2023 05 09.
Article in English | MEDLINE | ID: mdl-37115227

ABSTRACT

Paper surface functionalization with polyamidoamine (PAMAM) dendrimers has been developed for increased sensitivity analysis of proteins by paper spray mass spectrometry (PS-MS). PAMAM is a branched polymeric compound with an ethylenediamine core linked to repeating PAMAM units that generates an outer surface rich in primary amines. These positively charged amine groups can interact electrostatically with negatively charged residues (e.g., aspartate, glutamate) on the protein surface. PAMAM inner amide moieties can also promote hydrogen bonding with protein surface oxygens, making PAMAM a useful material for protein extraction. PAMAM-functionalized PS-MS paper strips were used to extract proteins from biofluids, dipped in acetonitrile to remove unbound constituents, dried, and then measured with PS-MS. The use of this strategy was optimized and compared with unmodified paper strips. PAMAM-functionalized paper substrates provided sixfold greater sensitivity for albumin, 11-fold for hemoglobin, sevenfold for insulin, and twofold for lysozyme. The analytical performance of the functionalized paper substrate was evaluated through the analysis of albumin in urine, achieving linearity with R2 > 0.99, LOD of 1.1 µg mL-1, LOQ of 3.8 µg mL-1, precision better than 10%, and relative recovery 70-83%. The method was applied to quantify urinary albumin from nine anonymous patient samples (concentrations ranged from 6.5 to 77.4 µg mL-1), illustrating its potential for the diagnosis of microalbuminuria. These data demonstrate the utility of paper modification with the PAMAM dendrimer for sensitive PS-MS analysis of proteins, opening a path for further applications in clinical diagnosis through the analysis of disease-related proteins.


Subject(s)
Dendrimers , Humans , Dendrimers/chemistry , Polyamines/chemistry , Mass Spectrometry , Albumins
5.
Rapid Commun Mass Spectrom ; 37(8): e9487, 2023 Apr 30.
Article in English | MEDLINE | ID: mdl-36739105

ABSTRACT

RATIONALE: Post-separation addition of chemical modifiers in liquid chromatography-mass spectrometry is widely used for improving ionization sensitivity and selectivity. This is typically accomplished using a post-column T-junction, which can result in sample dilution and imperfect mixing. We present a passive semi-permeable hollow fiber membrane approach for the addition of chemical modifiers that avoids these issues. METHODS: Model compounds were directly infused by flow injection to an electrospray ionization triple quadrupole mass spectrometer after passing through a polydimethylsiloxane hollow fiber membrane. Ionization enhancement reagents were introduced into the flowing stream by membrane permeation from aqueous solutions. Ionization enhancement from volatile acids and bases in positive and negative electrospray ionization was evaluated to assess the feasibility of this approach. RESULTS: The membrane-based apparatus resulted in relative ionization enhancement factors of up to 14×, depending upon the analyte, reagent, and ionization mode used. Ionization enhancement signal stability is reasonable (relative standard deviation of 5-7%) for extended periods from the same reagent solution, and minimal analyte dilution is observed. A proof-of-concept demonstration of the chromatographic "trifluoroacetic acid fix" strategy is presented. CONCLUSIONS: An on-line mass spectrometry ionization reagent addition method with potential post-chromatography reagent addition applications was developed using a hollow fiber polydimethylsiloxane membrane. This approach offers a promising alternative to traditional methods requiring additional hardware such as pumps and T-junctions that can result in sample dilution and imperfect reagent mixing.

6.
Drug Test Anal ; 15(5): 484-494, 2023 May.
Article in English | MEDLINE | ID: mdl-36605020

ABSTRACT

Carfentanil is one of the most potent synthetic opioids ever developed, with an estimated analgesic potency approximately 20-100 times that of fentanyl and 10,000 times that of morphine. Carfentanil has been appearing in the illicit drug supply in many regions and has been linked to fatal overdose events. A subset of 59 street drug samples obtained in Victoria, B.C., that were confirmed to contain carfentanil were analyzed by mass spectrometry for this study. Carfentanil quantitation by paper spray mass spectrometry ranged from 0.05 to 2.95 w/w% (median = 0.32%) in the original drug sample. Paper spray mass spectrometry analysis also detected two unknown peaks at m/z 380.2 and 381.2 in 31 of these 59 samples (53%). Initial tandem mass spectrometry experiments revealed structural similarities between these unknown compounds and carfentanil, suggesting they were potential structural analogs, possibly arising from incomplete purification during synthesis. High-resolution mass spectrometry determined the chemical formulas of these compounds as C23 H29 N3 O2 (m/z 380.2333) and C23 H29 N2 O3 (m/z 381.2137). Literature and tandem mass spectrometry results were used to determine the identity of these potential new psychoactive substances, C23 H29 N3 O2 as desmethylcarfentanil amide and C23 H29 N2 O3 as desmethylcarfentanil acid. µ-Opioid receptor binding modeling determined that the binding poses of these analogs were nearly identical to that of carfentanil with relative binding energy calculations of 0.544 kJ/mol (desmethylcarfentanil amide) and -0.171 kJ/mol (desmethylcarfentanil acid); these data suggest they may share the toxic effects of carfentanil and have similar potencies.


Subject(s)
Illicit Drugs , Fentanyl , Analgesics, Opioid , Tandem Mass Spectrometry , Amides
7.
ACS ES T Water ; 3(10): 3293-3304, 2023 Oct 13.
Article in English | MEDLINE | ID: mdl-38455156

ABSTRACT

The tire-derived contaminant N-(1,3-dimethylbutyl)-N'-phenyl-p-phenylenediamine quinone (6-PPDQ) was recently identified as a potent toxin to coho salmon (Oncorhynchus kisutch). Studies investigating 6-PPDQ have employed solid-phase extraction (SPE) or liquid-liquid extraction (LLE) with liquid chromatography-mass spectrometry (LC-MS), providing excellent sensitivity and selectivity. However, cleanup and pre-enrichment steps (SPE/LLE) followed by chromatographic separation can be time- and cost-intensive, limiting sample throughput. The ubiquitous distribution of 6-PPDQ necessitates numerous measurements to identify hotspots for targeted mitigation. We recently developed condensed phase membrane introduction mass spectrometry (CP-MIMS) for rapid 6-PPDQ analysis (2.5 min/sample), with a simple workflow and low limit of detection (8 ng/L). Here, we describe improved quantitation using isotopically labeled internal standards and inclusion of a suite of PPDQ analogues. A low-cost autosampler and data processing software were developed from a three-dimensional (3D) printer and Matlab to fully realize the high-throughput capabilities of CP-MIMS. Cross-validation with a commercial LC-MS method for 10 surface waters provides excellent agreement (slope: 1.01; R2 = 0.992). We employ this analytical approach to probe fundamental questions regarding sample stability and sorption of 6-PPDQ under lab-controlled conditions. Further, the results for 192 surface water samples provide the first spatiotemporal characterization of PPDQs on Vancouver Island and the lower mainland of British Columbia.

8.
J Hazard Mater ; 440: 129798, 2022 10 15.
Article in English | MEDLINE | ID: mdl-36027751

ABSTRACT

With the increasing use of unconventional, heavy crude oils there is growing interest in potential impacts of a diluted bitumen (DB) spill in marine and freshwater environments. DB has the potential to release several toxic, trace organic contaminants to the water column. Here, the aqueous concentrations and compositions of two classes of organic contaminants, naphthenic acids (NAs) and polycyclic aromatic hydrocarbons (PAHs), are followed over 8 weeks after a simulated spill of DB (10 L) into a freshwater mesocosm (1200 L) with river sediment (2.4 kg). These complex samples contain biogenic dissolved organic matter, inorganic ions, petroleum contaminants, suspended sediments, and oil droplets. We report the first use of condensed phase membrane introduction mass spectrometry (CP-MIMS) as a direct sampling platform in a complex multi-phase mesocosm spill tank study to measure trace aqueous phase contaminants with little to no sample preparation (dilution and/or pH adjustment). CP-MIMS provides complementary strengths to conventional analytical approaches (e.g., gas- or liquid chromatography mass spectrometry) by allowing the entire sample series to be screened quickly. Trace NAs are measured as carboxylates ([M-H]-) using electrospray ionization and PAHs are detected as radical cations (M+•) using liquid electron ionization coupled to a triple quadrupole mass spectrometer. The DB-affected mesocosm exhibits NA concentrations from 0.3 to 1.2 mg/L, which rise quickly over the first 2 - 5 days , then decrease slowly over the remainder of the study period. The NA profile (measured as the full scan in negative-electrospray ionization at nominal mass resolution) shifts to lower m/z with weathering, a process followed by principal component analysis of the normalized mass spectra. We couple CP-MIMS with high-resolution mass spectrometry to follow changes in molecular speciation over time, which reveals a concomitant shift from classical 'O2' naphthenic acids to more oxidized analogues. Concentrations of PAHs and alkylated analogues (C1 - C4) in the DB-affected water range from 0 to 5 µg/L. Changes in PAH concentrations depend on ring number and degree of alkylation, with small and/or lightly alkylated (C0 - C2) PAH concentrations rising to a maximum in the first 4 - 8 days (100 - 200 h) before slowly decaying over the remainder of the study period. Larger and heavily alkylated (C3 - C4) PAH concentrations generally rise slower, with some species remaining below the detection limit throughout the study period (e.g., C20H12 class including benzo[a]pyrene). In contrast, a control mesocosm (without oil) exhibited NA concentrations below 0.05 mg/L and PAHs were below detection limit. Capitalizing on the rapid analytical workflow of CP-MIMS, we also investigate the impacts of sample filtration at the time of sampling (on NA and PAH data) and sample storage time (on NA data only).


Subject(s)
Petroleum , Polycyclic Aromatic Hydrocarbons , Benzo(a)pyrene , Carboxylic Acids , Hydrocarbons , Mass Spectrometry/methods , Petroleum/analysis , Polycyclic Aromatic Hydrocarbons/analysis , Water/chemistry
9.
Analyst ; 147(13): 3109-3117, 2022 Jun 27.
Article in English | MEDLINE | ID: mdl-35708603

ABSTRACT

A direct mass spectrometry method utilizing reactive paper spray ionization was developed for sensitive cannabinoid quantitation in biofluid matrices. The ca. 2-minute sample measurements used on-paper derivatization to significantly increase paper spray mass spectrometry (PS-MS) positive ion mode sensitivity while minimizing sample preparation steps. Calibrations demonstrate high linearity, with R2 > 0.99 for (-)-trans-Δ9-tetrahydrocannabinol (THC) in oral fluid and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC-COOH) in urine. The limit of detection and lower limit of quantitation were 0.78 and 10 ng mL-1 for THC in oral fluid and 1.3 and 10 ng mL-1 for THC-COOH in urine, respectively. THC-COOH levels measured by reactive PS-MS in seven spiked human urine samples showed bias of -9.4 to 5.9%, and percent difference values of -16.8 to 9.8% in comparison with a reference LC-MS method. Based upon the method simplicity, validation experiments, sensitivity, and rapidity, we conclude that reactive PS-MS has potential applications for rapid cannabinoid drug testing in urine and oral fluid.


Subject(s)
Cannabinoids , Dronabinol , Cannabinoids/analysis , Chromatography, Liquid/methods , Dronabinol/analysis , Humans , Mass Spectrometry , Substance Abuse Detection/methods
10.
Drug Alcohol Depend ; 235: 109427, 2022 06 01.
Article in English | MEDLINE | ID: mdl-35405459

ABSTRACT

BACKGROUND: Drug checking uses analytical chemistry technologies to report on the composition of drugs from the unregulated market to reduce substance use-related risks, while additionally allowing for monitoring and reporting of the supply. In the context of an overdose crisis linked to fentanyl, we used drug checking data to examine variability within the illicit opioid supply. METHODS: In this time-series analysis, data was collected from a drug checking service in Victoria, Canada from November 2020 to July 2021. Drugs reported as opioids by participants of the service (N = 454) were analyzed to determine sample composition and paper spray mass spectroscopy was used to quantify low-concentration actives. Interquartile and statistical process control (SPC) analysis, namely standard deviation control charts, were used to examine the degree of variability among samples. RESULTS: Fentanyl was found in 96% of samples reported to be opioids, with a median concentration of 9%. Concentrations varied significantly, with a standard deviation of 7% for fentanyl and where nearly 20% of data points fell outside the control limits. Over half of the samples contained an additional and unexpected active, most commonly etizolam (43% of samples). Etizolam also showed a large level of variability, uncorrelated to that of fentanyl. CONCLUSIONS: Based on our chemical quantification and SPC analysis, a high degree of variability was found in opioid samples from the unregulated market in both the drugs detected and the concentrations of those drugs. This demonstrated the opioid crisis to be less attributable to a bad batch of drugs but rather the general variability found in the unregulated market.


Subject(s)
Analgesics, Opioid , Drug Overdose , Analgesics, Opioid/analysis , Canada , Fentanyl/analysis , Humans , Mass Spectrometry
11.
Int J Drug Policy ; 102: 103611, 2022 04.
Article in English | MEDLINE | ID: mdl-35151084

ABSTRACT

BACKGROUND: In British Columbia, Canada, illicit opioids have been increasingly combined with etizolam, a benzodiazepine analog, that continues to challenge popular portable drug checking technologies as it is often present in low concentrations as a result of its high potency. An unknown combination of opioids and benzodiazepines may have dangerous consequences due to unpredictable dosing, increased respiratory depression, and complicated overdose response measures. METHODS: Surface-enhanced Raman spectroscopy (SERS) using a portable Raman spectrometer is used to establish a univariate model for the detection of etizolam in opioid drug mixtures (n=100) obtained from the Vancouver Island Drug Checking Project, where the presence of etizolam has been determined using paper-spray mass spectrometry. Benzodiazepine immunoassay test strips are also performed on all samples for comparison. RESULTS: SERS is shown to detect etizolam with high sensitivity (96%) and specificity (86%). In contrast, benzodiazepine test strips demonstrate a low sensitivity (8%) for the detection of etizolam of the same samples (n=100), with only small improvements when studied over a larger subset of samples (n=506, sensitivity = 29%). CONCLUSION: We have demonstrated the potential of SERS for trace detection of etizolam within complex sample matrices. Since SERS is one of the few portable technologies capable of trace detection, further studies on its ability for quantification and discrimination of trace adulterants in street samples is of significant interest for point-of-care applications.


Subject(s)
Analgesics, Opioid , Spectrum Analysis, Raman , Analgesics, Opioid/analysis , Benzodiazepines , British Columbia , Diazepam/analogs & derivatives , Fentanyl/analysis , Humans
12.
Environ Sci Technol ; 56(5): 3096-3105, 2022 03 01.
Article in English | MEDLINE | ID: mdl-35175743

ABSTRACT

Oil sands process waters can release toxic naphthenic acids (NAs) into aquatic environments. Analytical techniques for NAs are challenged by sample complexity and interference from naturally occurring dissolved organic matter (DOM). Herein, we report the use of a poly(dimethylsiloxane) (PDMS) polymer membrane for the on-line separation of NAs from DOM and use direct infusion electrospray ionization mass spectrometry to yield meaningful qualitative and quantitative information with minimal sample cleanup. We compare the composition of membrane-permeable species from natural waters fortified with a commercial NA mixture to those derived from weak anion exchange solid-phase extraction (SPE) using high-resolution mass spectrometry. The results show that SPE retains a wide range of carboxylic acids, including biogenic DOM, while permeation through PDMS was selective for petrogenic classically defined NAs (CnH2n+zO2). A series of model compounds (log Kow ∼1-7) were used to characterize the perm-selectivity and reveal the separation is based on hydrophobicity. This convenient sample cleanup method is selective for the O2 class of NAs and can be used prior to conventional analysis or as an on-line analytical strategy when coupled directly to mass spectrometry.


Subject(s)
Dissolved Organic Matter , Oil and Gas Fields , Water Pollutants, Chemical , Carboxylic Acids/analysis , Spectrometry, Mass, Electrospray Ionization/methods , Water Pollutants, Chemical/analysis
13.
Drug Alcohol Rev ; 41(2): 410-418, 2022 02.
Article in English | MEDLINE | ID: mdl-34347332

ABSTRACT

INTRODUCTION: Drug checking services for harm reduction and overdose prevention have been implemented in many jurisdictions as a public health intervention in response to the opioid overdose crisis. This study demonstrates the first on-site use of paper spray mass spectrometry for quantitative drug checking to address the limitations of current on-site drug testing technologies. METHODS: Paper spray mass spectrometry was used to provide on-site drug checking services at a supervised consumption site in the Downtown Eastside of Vancouver, British Columbia, Canada during a 2-day pilot test in August 2019. The method included the targeted quantitative measurement of 49 drugs and an untargeted full scan to assist in identifying unknown/unexpected components. RESULTS: During the pilot, 113 samples were submitted for analysis, with 88 (78%) containing the client expected substance. Fentanyl was detected in 45 of 59 expected fentanyl samples, and in 50 (44%) samples overall at a median concentration of 3.6% (w/w%). The synthetic precursor of fentanyl, 4-anilino-N-phenethyl-piperidine (4-ANPP), was found in 74.0% of all fentanyl samples at a median concentration of 2.2%, suggesting widespread poor manufacturing practices. Etizolam was detected in 10 submitted samples anticipated to be fentanyl at a median concentration of 2.5%. No clients submitting these samples expected etizolam or a benzodiazepine in their sample. In three instances, it was co-measured with fentanyl, and in seven cases it was detected alone. DISCUSSION AND CONCLUSIONS: The quantitative capabilities and low detection limits demonstrated by paper spray mass spectrometry offer distinct benefits over existing on-site drug checking methods and harm reduction services.


Subject(s)
Drug Overdose , Illicit Drugs , Analgesics, Opioid/analysis , British Columbia , Canada , Drug Overdose/prevention & control , Fentanyl/analysis , Harm Reduction , Humans , Illicit Drugs/analysis , Mass Spectrometry , Pilot Projects , Technology
14.
Int J Drug Policy ; 97: 103409, 2021 11.
Article in English | MEDLINE | ID: mdl-34392112

ABSTRACT

BACKGROUND: There has been a recent increase in adulteration of opioids with low concentration actives such as fentanyl analogues and benzodiazepines. As drug checking projects using vibrational spectroscopy continue to seek confirmatory lab-based testing, the concern and reality of missing these potentially harmful substances in point-of-care testing is prevalent. METHODS: A portable GC-MS was used to analyze select opioid samples acquired at a drug checking service in Victoria, Canada (n=59). Certified reference standards of several fentanyl analogues and benzodiazepines were measured to guide targeted analysis of these samples. Results were compared with those obtained using a lab-based paper spray mass spectrometer. RESULTS: Portable GC-MS was able to identify 62% of samples containing carfentanil and 36% of samples containing etizolam. In the case of etizolam, the success rate was higher for more potent samples: 78% of etizolam-containing samples were identified when the etizolam concentration was above 3% by weight. In comparison, infrared spectroscopy was able to detect etizolam in only 9% of the etizolam-containing samples, and is not sensitive enough to detect carfentanil at relevant concentrations. CONCLUSIONS: Portable GC-MS has potential in identifying low concentration substances in a point-of-care setting, without relying on subsequent off-site confirmatory testing.


Subject(s)
Analgesics, Opioid , Pharmaceutical Preparations , Analgesics, Opioid/analysis , Diazepam/analogs & derivatives , Fentanyl/analogs & derivatives , Gas Chromatography-Mass Spectrometry , Humans
15.
Sci Total Environ ; 765: 144206, 2021 Apr 15.
Article in English | MEDLINE | ID: mdl-33418326

ABSTRACT

Crude oil spills have well-documented, deleterious impacts on the hydrosphere. In addition to macroscopic effects on wildlife and waterscapes, several classes of petroleum derived compounds, such as naphthenic acids (NAs) and polycyclic aromatic hydrocarbons (PAHs), may be released into the water and present aquatic contamination hazards. The concentrations of these contaminants may be affected by both oil type and water chemistry. We characterize the concentrations of NAs and PAHs in natural and constructed waters, spanning a range of pH and salinity, and directly compare the influence of diluted bitumen (DB) and conventional crude (CC) oil, using condensed-phase membrane introduction mass spectrometry (CP-MIMS) as a direct sampling, on-line technique. The concentration and isomer class profiles of classical NAs in the aqueous phase were assessed using electrospray ionization in negative-ion mode as [M-H]- whereas PAH concentrations were monitored using liquid electron ionization (LEI) in positive-ion mode as [M+•]. NA concentrations (0.03-25 ppm) were highly pH-dependent, and an order of magnitude greater in water samples contaminated with DB than CC. Conversely, concentrations of naphthalene (10-130 ppb) and alkyl-naphthalenes (10-90 ppb) were three to four-fold higher in water samples exposed to CC. We demonstrate that naturally occurring dissolved organic matter does not bias results from the membrane sampling approach employed, and that DB and CC contaminated waters can be differentiated using principal component analysis of the NA isomer class distribution in both constructed and natural waters. Finally, we describe the first demonstration of the concurrent analysis of trace NAs and PAHs in the same water sample by controlling perm-selectivity at the membrane and the ionization mode of the mass spectrometer. The techniques employed here for trace analysis of petroleum derived compounds in water can be applied to rapid screening and real-time monitoring of contamination and remediation processes.

16.
Environ Sci Technol Lett ; 8(12): 1051-1056, 2021 Dec 14.
Article in English | MEDLINE | ID: mdl-38433861

ABSTRACT

The oxidative transformation product of a common tire preservative, identified as N-(1,3-dimethylbutyl)-N'-phenyl-p-phenylenediamine quinone (6-PPDQ), has recently been found to contribute to "urban runoff mortality syndrome" in Coho salmon at nanogram per liter levels. Given the number of fish-bearing streams with multiple stormwater inputs, large-scale campaigns to identify 6-PPDQ sources and evaluate mitigation strategies will require sensitive, high-throughput analytical methods. We report the development and optimization of a direct sampling tandem mass spectrometry method for semiquantitative 6-PPDQ determinations using a thin polydimethylsiloxane membrane immersion probe. The method requires no sample cleanup steps or chromatographic separations, even in complex, heterogeneous samples. Quantitation is achieved by the method of standard additions, with a detection limit of 8 ng/L and a duty cycle of 15 min/sample. High-throughput screening provides semiquantitative concentrations with similar sensitivity and a full analytical duty cycle of 2.5 min/sample. Preliminary data and performance metrics are reported for 6-PPDQ present in representative environmental and stormwater samples. The method is readily adapted for real-time process monitoring, demonstrated by following the dissolution of 6-PPDQ from tire fragments and subsequent removal in response to added sorbents.

17.
Anal Chem ; 92(23): 15480-15488, 2020 12 01.
Article in English | MEDLINE | ID: mdl-33076653

ABSTRACT

Polycyclic aromatic hydrocarbons (PAHs) are routinely screened for in soils, where quantitation of structural isomers is critical due to varying toxicity within PAH isomer classes. While chromatographic methods provide isomer resolution, such strategies are cost and time intensive. To address these challenges, we present condensed phase membrane introduction mass spectrometry using liquid electron ionization/chemical ionization (CP-MIMS-LEI/CI) as a direct mass spectrometry technique that provides rapid, quantitative results for PAH isomer measurements in soil samples. A methanol acceptor phase is flowed through a probe-mounted polydimethylsiloxane hollow fiber membrane directly immersed into a dichloromethane/soil slurry. PAHs and dichloromethane co-permeate the membrane into the acceptor solvent, whereas particulates and charged matrix components remain in the sample. A nanoflow of the membrane permeate is then directly infused into a LEI/CI interfaced triple quadrupole mass spectrometer. Diagnostic PAH adduct ions were formed at either M + 45 ([M + CH2Cl + CH3OH-HCl]+) or M + 47 ([M + CHCl2-HCl]+). This allowed the development of specific MS/MS transitions for individual PAH isomers. These transitions were subsequently used for the direct analyses of PAHs in real soils where CP-MIMS-LEI/CI was shown to be rapid (15 soil samples/h) and sensitive (ng/g level detection limits). CP-MIMS-LEI/CI results compared well to those obtained using GC-MS (average percent difference of -9% across 9 PAHs in 8 soil samples), presenting a compelling argument for direct, quantitative screening of PAHs in soils by CP-MIMS-LEI/CI, particularly given the simple workflow and short analytical duty cycle.


Subject(s)
Membranes, Artificial , Polycyclic Aromatic Hydrocarbons/analysis , Polycyclic Aromatic Hydrocarbons/chemistry , Soil/chemistry , Spectrometry, Mass, Electrospray Ionization/methods , Isomerism , Time Factors
18.
J Am Soc Mass Spectrom ; 31(4): 908-916, 2020 Apr 01.
Article in English | MEDLINE | ID: mdl-32154722

ABSTRACT

Direct mass spectrometry has grown significantly due to wide applicability, relative ease of use, and high sample throughput. However, many current direct mass spectrometry methods are largely based on ambient ionization techniques that can suffer from matrix effects and poor selectivity. A strategy that addresses these shortcomings is condensed phase membrane introduction mass spectrometry-liquid electron ionization utilizing in situ liquid reagent chemical ionization (CP-MIMS-LEI/CI). In CP-MIMS measurements, a semipermeable hollow fiber polydimethylsiloxane membrane probe is directly immersed into a complex sample. Neutral, hydrophobic analytes permeating the membrane are entrained by a continuously flowing liquid acceptor phase (nL/min) to an LEI/CI source, where the liquid is nebulized, followed by analyte vaporization and ionization. This study marks the first intentional exploitation of the liquid CP-MIMS acceptor phase as an in situ means of providing liquid chemical ionization (CI) reagents for improved analyte sensitivity and selectivity (CP-MIMS-LEI/CI). Acetonitrile and diethyl ether were used as a combination acceptor phase/CI proton transfer reagent system for the direct analysis of dialkyl phthalates. Using isotopically labeled reagents, the gas phase ionization mechanism was found to involve reagent autoprotonation, followed by proton transfer to dialkyl phthalates. A demonstration of the applicability of CP-MIMS-LEI/CI for rapid and sensitive screening of bis(2-ethylhexyl) phthalate in house dust samples is presented. The detection limit in house dust (6 mg/kg) is comparable to that obtained by conventional analyses, but without time-consuming sample workup or chromatographic separation steps.

19.
Mass Spectrom Rev ; 39(5-6): 703-744, 2020 09.
Article in English | MEDLINE | ID: mdl-32048319

ABSTRACT

Mass spectrometry has been the "gold standard" for drugs of abuse (DoA) analysis for many decades because of the selectivity and sensitivity it affords. Recent progress in all aspects of mass spectrometry has seen significant developments in the field of DoA analysis. Mass spectrometry is particularly well suited to address the rapidly proliferating number of very high potency, novel psychoactive substances that are causing an alarming number of fatalities worldwide. This review surveys advancements in the areas of sample preparation, gas and liquid chromatography-mass spectrometry, as well as the rapidly emerging field of ambient ionization mass spectrometry. We have predominantly targeted literature progress over the past ten years and present our outlook for the future. © 2020 Periodicals, Inc. Mass Spec Rev.


Subject(s)
Gas Chromatography-Mass Spectrometry/methods , Illicit Drugs/analysis , Mass Spectrometry/methods , Substance Abuse Detection/methods , Chromatography, Liquid/methods , Forensic Medicine/methods , Humans , Illicit Drugs/isolation & purification , Liquid Phase Microextraction , Sensitivity and Specificity , Solid Phase Microextraction
20.
Sci Total Environ ; 716: 137063, 2020 May 10.
Article in English | MEDLINE | ID: mdl-32044488

ABSTRACT

The application of direct mass spectrometry techniques to the analysis of complex samples has a number of advantages including reduced sample handling, higher sample throughput, in situ process monitoring, and the potential for adaptation to on-site analysis. We report the application of a semi-permeable capillary hollow fibre membrane probe (immersed directly into an aqueous sample) coupled to a triple quadrupole mass spectrometer by a continuously flowing methanol acceptor phase for the rapid analysis of naphthenic acids with unit mass resolution. The intensity of the naphthenic acid-associated peaks in the mass spectrum are normalized to an internal standard in the acceptor phase for quantitation and the relative abundance of the peaks in the mass spectrum are employed to monitor compositional changes in the naphthenic acid mixture using principle component analysis. We demonstrate the direct analysis of a synthetic oil sands process-affected water for classical naphthenic acids (CnH2n+zO2) as they are attenuated through constructed wetlands containing sedge (Carex aquatilis), cattail (Typha latifolia), or bulrush (Schoenoplectus acutus). Quantitative results for on-line membrane sampling compare favourably to those obtained by solid-phase extraction high-resolution mass spectrometry. Additionally, chemometric analysis of the mass spectra indicates a clear discrimination between naphthenic acid-influenced and natural background waters. Furthermore, the compositional changes within complex naphthenic acid mixtures track closely with the degree of attenuation. Overall, the technique is successful in following changes in both the concentration and composition of naphthenic acids from synthetic oil sands process-affected waters, with the potential for high throughput screening and environmental forensics.


Subject(s)
Wetlands , Carboxylic Acids , Mass Spectrometry , Oil and Gas Fields , Water Pollutants, Chemical
SELECTION OF CITATIONS
SEARCH DETAIL