Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 137
Filter
1.
Article in English | MEDLINE | ID: mdl-38764317

ABSTRACT

BACKGROUND: Data using real-world assessments of aortic regurgitation (AR) severity to identify rates of Heart Valve Team evaluation and aortic valve replacement (AVR), as well as mortality among untreated patients, are lacking. The present study assessed these trends in care and outcomes for real-world patients with documented AR. METHODS: Using a deidentified data set (January 2018-March 2023) representing 1,002,853 patients >18 years of age from 25 US institutions participating in the egnite Database (egnite, Inc.) with appropriate permissions, patients were classified by AR severity in echocardiographic reports. Rates of evaluation by the Heart Valve Team, AVR, and all-cause mortality without AVR were examined using Kaplan-Meier estimates and compared using the log-rank test. RESULTS: Within the data set, 845,113 patients had AR severity documented. For moderate-to-severe or severe AR, respectively, 2-year rates (95% confidence interval) of evaluation by the Heart Valve Team (43.5% [41.7%-45.3%] and 65.4% [63.3%-67.4%]) and AVR (19.4% [17.6%-21.1%] and 46.5% [44.2%-48.8%]) were low. Mortality at 2 years without AVR increased with greater AR severity, up to 20.7% for severe AR (p < 0.001). In exploratory analyses, 2-year mortality for untreated patients with left ventricular end-systolic dimension index > 25 mm/m2 was similar for moderate (34.3% [29.2%-39.1%]) and severe (37.2% [24.9%-47.5%]) AR. CONCLUSIONS: Moderate or greater AR is associated with poor clinical outcomes among untreated patients at 2 years. Rates of Heart Valve Team evaluation and AVR were low for those with moderate or greater AR, suggesting that earlier referral to the Heart Valve Team could be beneficial.

2.
N Engl J Med ; 2024 Apr 07.
Article in English | MEDLINE | ID: mdl-38587261

ABSTRACT

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).

4.
Circ Cardiovasc Interv ; 17(2): e013298, 2024 02.
Article in English | MEDLINE | ID: mdl-38235547

ABSTRACT

BACKGROUND: Frailty associates with worse outcomes after transcatheter aortic valve replacement (TAVR). Sarcopenia underlies frailty, but the association between a comprehensive assessment of sarcopenia-muscle mass, strength, and performance-and outcomes after TAVR has not been examined. METHODS: From a multicenter prospective registry of patients with symptomatic severe aortic stenosis undergoing TAVR, 445 who had a preprocedure computed tomography and clinical assessment of frailty were included. Cross-sectional muscle (psoas and paraspinal) areas were measured on computed tomography and indexed to height. Gait speed and handgrip strength were obtained, and patients were dichotomized into fast versus slow; strong versus weak; and normal versus low muscle mass. As measures of body composition, cross-sectional fat (subcutaneous and visceral) was measured and indexed to height. RESULTS: The frequency of patients who were slow, weak, and had low muscle mass was 56%, 59%, and 42%, respectively. Among the 3 components of sarcopenia, only slower gait speed (muscle performance) was independently associated with increased post-TAVR mortality (adjusted hazard ratio, 1.12 per 0.1 m/s decrease [95% CI, 1.04-1.21]; P=0.004; adjusted hazard ratio, 1.38 per 1 SD decrease [95% CI, 1.11-1.72]; P=0.004). Meeting multiple sarcopenia criteria was not associated with higher mortality risk than fewer. Lower indexed visceral fat area (adjusted hazard ratio, 1.48 per 1 SD decrease [95% CI, 1.15-1.89]; P=0.002) was associated with mortality but indexed subcutaneous fat was not. Death occurred in 169 (38%) patients. CONCLUSIONS: Among patients with symptomatic severe aortic stenosis and comprehensive sarcopenia and body composition phenotyping, gait speed was the only sarcopenia measure associated with post-TAVR mortality. Lower visceral fat was also associated with increased risk pointing to an obesity paradox also observed in other patient populations. These findings reinforce the clinical utility of gait speed as a measure of risk and a potential target for adjunctive interventions alongside TAVR to optimize clinical outcomes.


Subject(s)
Aortic Valve Stenosis , Frailty , Sarcopenia , Transcatheter Aortic Valve Replacement , Humans , Sarcopenia/diagnostic imaging , Sarcopenia/complications , Frailty/diagnosis , Frailty/complications , Treatment Outcome , Hand Strength , Cross-Sectional Studies , Risk Assessment , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Body Composition , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Risk Factors
7.
JACC Cardiovasc Imaging ; 17(5): 471-485, 2024 May.
Article in English | MEDLINE | ID: mdl-38099912

ABSTRACT

BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve , Predictive Value of Tests , Recovery of Function , Severity of Illness Index , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/physiopathology , Male , Female , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve/physiopathology , Treatment Outcome , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Aged , Risk Factors , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Time Factors , Aged, 80 and over , Heart Valve Prosthesis , Feasibility Studies , Risk Assessment , Prosthesis Design , Echocardiography, Three-Dimensional
8.
Article in English | MEDLINE | ID: mdl-37962288

ABSTRACT

BACKGROUND: The CLASP IID (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical) trial is the first randomized controlled trial comparing the PASCAL system and the MitraClip system in prohibitive risk patients with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: The study sought to report primary and secondary endpoints and 1-year outcomes for the full cohort of the CLASP IID trial. METHODS: Prohibitive-risk patients with 3+/4+ DMR were randomized 2:1 (PASCAL:MitraClip). One-year assessments included secondary effectiveness endpoints (mitral regurgitation [MR] ≤2+ and MR ≤1+), and clinical, echocardiographic, functional, and quality-of-life outcomes. Primary safety (30-day composite major adverse events [MAE]) and effectiveness (6-month MR ≤2+) endpoints were assessed for the full cohort. RESULTS: Three hundred patients were randomized (PASCAL: n = 204; MitraClip: n = 96). At 1 year, differences in survival, freedom from heart failure hospitalization, and MAE were nonsignificant (P > 0.05 for all). Noninferiority of the PASCAL system compared with the MitraClip system persisted for the primary endpoints in the full cohort (For PASCAL vs MitraClip, the 30-day MAE rates were 4.6% vs 5.4% with a rate difference of -0.8% and 95% upper confidence bound of 4.6%. The 6-month MR≤2+ rates were 97.9% vs 95.7% with a rate difference of 2.2% and 95% lower confidence bound (LCB) of -2.5%, for, respectively). Noninferiority was met for the secondary effectiveness endpoints at 1 year (MR≤2+ rates for PASCAL vs MitraClip were 95.8% vs 93.8% with a rate difference of 2.1% and 95% LCB of -4.1%. The MR≤1+ rates were 77.1% vs 71.3% with a rate difference of 5.8% and 95% LCB of -5.3%, respectively). Significant improvements in functional classification and quality of life were sustained in both groups (P <0.05 for all vs baseline). CONCLUSIONS: The CLASP IID trial full cohort met primary and secondary noninferiority endpoints, and at 1 year, the PASCAL system demonstrated high survival, significant MR reduction, and sustained improvements in functional and quality-of-life outcomes. Results affirm the PASCAL system as a beneficial therapy for prohibitive-surgical-risk patients with significant symptomatic DMR.

9.
JACC Cardiovasc Interv ; 16(23): 2820-2832, 2023 Dec 11.
Article in English | MEDLINE | ID: mdl-37905772

ABSTRACT

BACKGROUND: Favorable 6-month outcomes from the CLASP IID Registry (Edwards PASCAL transcatheter valve repair system pivotal clinical trial) demonstrated that mitral valve transcatheter edge-to-edge repair with the PASCAL transcatheter valve repair system is safe and beneficial for treating prohibitive surgical risk degenerative mitral regurgitation (DMR) patients with complex mitral valve anatomy. OBJECTIVES: The authors sought to assess 1-year safety, echocardiographic and clinical outcomes from the CLASP IID Registry. METHODS: Patients with 3+ or 4+ DMR who were at prohibitive surgical risk, had complex mitral valve anatomy based on the MitraClip Instructions for Use, and deemed suitable for treatment with the PASCAL system were enrolled prospectively. Safety, clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. Study oversight included a central screening committee, echocardiographic core laboratory, and clinical events committee. RESULTS: Ninety-eight patients were enrolled. One-year Kaplan-Meier (KM) estimates of freedom from composite major adverse events, all-cause mortality, and heart failure hospitalization were 83.5%, 89.3%, and 91.5%, respectively. Significant mitral regurgitation (MR) reduction was achieved at 1 year (P < 0.001 vs baseline) including 93.2% at MR ≤2+ and 57.6% at MR ≤1+ with improvements in related echocardiographic measures. NYHA functional class and Kansas City Cardiomyopathy Questionnaire score also improved significantly (P < 0.001 vs baseline). CONCLUSIONS: At 1 year, treatment with the PASCAL system demonstrated safety and significant MR reduction, with continued improvement in clinical, echocardiographic, functional, and quality-of-life outcomes, illustrating the value of the PASCAL system in the treatment of prohibitive surgical risk patients with 3+ or 4+ DMR and complex mitral valve anatomy.


Subject(s)
Cardiac Catheterization , Mitral Valve Insufficiency , Humans , Cardiac Catheterization/adverse effects , Echocardiography , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Treatment Outcome , Clinical Trials as Topic
10.
J Am Coll Cardiol ; 82(22): 2101-2109, 2023 11 28.
Article in English | MEDLINE | ID: mdl-37877909

ABSTRACT

BACKGROUND: The American College of Cardiology/American Heart Association guidelines recommend the assessment and grading of severity of aortic stenosis (AS) as mild, moderate, or severe, per echocardiogram, and recommend aortic valve replacement (AVR) when the AS is severe. OBJECTIVES: The authors sought to describe mortality rates across the entire spectrum of untreated AS from a contemporary, large, real-world database. METHODS: We analyzed a deidentified real-world data set including 1,669,536 echocardiographic reports (1,085,850 patients) from 24 U.S. hospitals (egnite Database, egnite). Patients >18 years of age were classified by diagnosed AS severity. Untreated mortality and treatment rates were examined with Kaplan-Meier (KM) estimates, with results compared using the log-rank test. Multivariate hazards analysis was performed to assess associations with all-cause mortality. RESULTS: Among 595,120 patients with available AS severity assessment, the KM-estimated 4-year unadjusted, untreated, all-cause mortality associated with AS diagnosis of none, mild, mild-to-moderate, moderate, moderate-to-severe, or severe was 13.5% (95% CI: 13.3%-13.7%), 25.0% (95% CI: 23.8%-26.1%), 29.7% (95% CI: 26.8%-32.5%), 33.5% (95% CI: 31.0%-35.8%), 45.7% (95% CI: 37.4%-52.8%), and 44.9% (95% CI: 39.9%-49.6%), respectively. Results were similar when adjusted for informative censoring caused by treatment. KM-estimated 4-year observed treatment rates were 0.2% (95% CI: 0.2%-0.2%), 1.0% (95% CI: 0.7%-1.3%), 4.2% (95% CI: 2.0%-6.3%), 11.4% (95% CI: 9.5%-13.3%), 36.7% (95% CI: 31.8%-41.2%), and 60.7% (95% CI: 58.0%-63.3%), respectively. After adjustment, all degrees of AS severity were associated with increased mortality. CONCLUSIONS: Patients with AS have high mortality risk across all levels of untreated AS severity. Aortic valve replacement rates remain low for patients with severe AS, suggesting that more research is needed to understand barriers to diagnosis and appropriate approach and timing for aortic valve replacement.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Treatment Outcome , Heart Valve Prosthesis Implantation/methods , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Echocardiography , Severity of Illness Index , Risk Factors
11.
Aging Cell ; 22(11): e13978, 2023 11.
Article in English | MEDLINE | ID: mdl-37731195

ABSTRACT

While frailty is a prominent risk factor in an aging population, the underlying biology of frailty is incompletely described. Here, we integrate 979 circulating proteins across a wide range of physiologies with 12 measures of frailty in a prospective discovery cohort of 809 individuals with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation. Our aim was to characterize the proteomic architecture of frailty in a highly susceptible population and study its relation to clinical outcome and systems-wide phenotypes to define potential novel, clinically relevant frailty biology. Proteomic signatures (specifically of physical function) were related to post-intervention outcome in AS, specifying pathways of innate immunity, cell growth/senescence, fibrosis/metabolism, and a host of proteins not widely described in human aging. In published cohorts, the "frailty proteome" displayed heterogeneous trajectories across age (20-100 years, age only explaining a small fraction of variance) and were associated with cardiac and non-cardiac phenotypes and outcomes across two broad validation cohorts (N > 35,000) over ≈2-3 decades. These findings suggest the importance of precision biomarkers of underlying multi-organ health status in age-related morbidity and frailty.


Subject(s)
Aortic Valve Stenosis , Cardiovascular Diseases , Frailty , Transcatheter Aortic Valve Replacement , Humans , Aged , Young Adult , Adult , Middle Aged , Aged, 80 and over , Proteomics , Risk Factors , Aortic Valve
12.
Circ Cardiovasc Interv ; 16(8): e012875, 2023 08.
Article in English | MEDLINE | ID: mdl-37503662

ABSTRACT

BACKGROUND: Depression and cognitive dysfunction (CD) are not routinely screened for in patients before transcatheter aortic valve replacement (TAVR) and their association with postprocedural outcomes is poorly understood. The objectives of this study are to determine the prevalence of depression and CD in patients with aortic stenosis undergoing TAVR and evaluate their association with mortality and quality of life. METHODS: We analyzed a prospective, multicenter TAVR registry that systematically screened patients for preexisting depression and CD with the Patient Health Questionnaire-2 and Mini-Cog, respectively. The associations with mortality were assessed with Cox proportional hazard models and quality of life (Kansas City Cardiomyopathy Questionnaire and EuroQol visual analogue scale) were evaluated using multivariable ordinal regression models. RESULTS: A total of 884 patients were included; median follow-up was 2.88 years (interquartile range=1.2-3.7). At baseline, depression was observed in 19.6% and CD in 31.8%. In separate models, after adjustment, depression (HR, 1.45 [95% CI, 1.13-1.86]; P<0.01) and CD (HR, 1.27 [95% CI, 1.02-1.59]; P=0.04) were each associated with increased mortality. Combining depression and CD into a single model, mortality was greatest among those with both depression and CD (n=62; HR, 2.06 [CI, 1.44-2.96]; P<0.01). After adjustment, depression was associated with 6.6 (0.3-13.6) points lower on the Kansas City Cardiomyopathy Questionnaire 1-year post-TAVR and 6.7 (0.5-12.7) points lower on the EuroQol visual analogue scale. CD was only associated with lower EuroQol visual analogue scale. CONCLUSIONS: Depression and CD are common in patients that undergo TAVR and are associated with increased mortality and worse quality of life. Depression may be a modifiable therapeutic target to improve outcomes after TAVR.


Subject(s)
Aortic Valve Stenosis , Cardiomyopathies , Cognitive Dysfunction , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Quality of Life , Prospective Studies , Depression/diagnosis , Depression/epidemiology , Treatment Outcome , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/epidemiology , Cognitive Dysfunction/diagnosis , Cognitive Dysfunction/epidemiology , Cognitive Dysfunction/etiology , Patient-Centered Care , Cardiomyopathies/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Risk Factors
13.
J Am Heart Assoc ; 12(13): e029542, 2023 07 04.
Article in English | MEDLINE | ID: mdl-37345820

ABSTRACT

Background Studies in mice and small patient subsets implicate metabolic dysfunction in cardiac remodeling in aortic stenosis, but no large comprehensive studies of human metabolism in aortic stenosis with long-term follow-up and characterization currently exist. Methods and Results Within a multicenter prospective cohort study, we used principal components analysis to summarize 12 echocardiographic measures of left ventricular structure and function pre-transcatheter aortic valve implantation in 519 subjects (derivation). We used least absolute shrinkage and selection operator regression across 221 metabolites to define metabolic signatures for each structural pattern and measured their relation to death and multimorbidity in the original cohort and up to 2 validation cohorts (N=543 for overall validation). In the derivation cohort (519 individuals; median age, 84 years, 45% women, 95% White individuals), we identified 3 axes of left ventricular remodeling, broadly specifying systolic function, diastolic function, and chamber volumes. Metabolite signatures of each axis specified both known and novel pathways in hypertrophy and cardiac dysfunction. Over a median of 3.1 years (205 deaths), a metabolite score for diastolic function was independently associated with post-transcatheter aortic valve implantation death (adjusted hazard ratio per 1 SD increase in score, 1.54 [95% CI, 1.25-1.90]; P<0.001), with similar effects in each validation cohort. This metabolite score of diastolic function was simultaneously associated with measures of multimorbidity, suggesting a metabolic link between cardiac and noncardiac state in aortic stenosis. Conclusions Metabolite profiles of cardiac structure identify individuals at high risk for death following transcatheter aortic valve implantation and concurrent multimorbidity. These results call for efforts to address potentially reversible metabolic biology associated with risk to optimize post-transcatheter aortic valve implantation recovery, rehabilitation, and survival.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Female , Animals , Mice , Aged, 80 and over , Male , Multimorbidity , Prospective Studies , Treatment Outcome , Aortic Valve/surgery , Ventricular Function, Left
14.
Int J Cardiovasc Imaging ; 39(9): 1677-1685, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37347380

ABSTRACT

Although it is assumed that more severe MR is associated with a greater burden of symptoms and lower exercise capacity, the relationship between symptoms, exercise capacity, and mitral regurgitant severity has not been well studied. We prospectively studied 67 (63 ± 11 years, 72% male) patients with at least mild degenerative MR and left ventricular ejection fraction ≥ 50% who underwent stress echocardiography, CMR, and evaluation with the Kansas City Cardiomyopathy questionnaire (KCCQ). Symptoms and exercise capacity were evaluated in the context of MR severity. Patients reporting dyspnea had lower KCCQ symptom scores (79 ± 23 vs. 96 ± 9, p = 0.01) and achieved lower percentage of age and gender predicted METs (114 ± 37 vs. 152 ± 43%, p < 0.001) compared to those without dyspnea. There was no significant difference in MR volume between those with vs. without dyspnea by CMR (43 ± 26 ml vs. 51 ± 28 ml, p = 0.3) or echocardiography (64 ± 28 vs. 73 ± 41ml, p = 0.4). Those with severe MR by CMR had similar KCCQ symptom scores (96 ± 10 vs. 89 ± 17, p = 0.04) and percentage of age and gender predicted METs (148 ± 42 vs. 133 ± 47%, p = 0.2) to those without severe MR. Those with severe MR by echocardiography had similar KCCQ symptom score (93 ± 15 vs. 89 ± 16, p = 0.3) and percentage of age and gender predicted METs (138 ± 43 vs. 153 ± 46%, p = 0.2) to those without severe MR. Patients with degenerative MR assessed by CMR and stress echocardiography, there was no relationship between MR severity and either symptoms or exercise capacity. These findings highlight the disconnect between symptoms and the severity of MR and challenge the assumption that correcting MR can be counted on to improve symptom status in patients with degenerative MR.


Subject(s)
Mitral Valve Insufficiency , Humans , Male , Female , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/complications , Stroke Volume , Ventricular Function, Left , Exercise Tolerance , Predictive Value of Tests , Severity of Illness Index
17.
Curr Cardiol Rep ; 25(3): 89-95, 2023 03.
Article in English | MEDLINE | ID: mdl-36787025

ABSTRACT

PURPOSE OF REVIEW: This review summarizes the current management of patients with newly diagnosed aortic stenosis. RECENT FINDINGS: Recent developments include detection of early myocardial dysfunction using serum B-type natriuretic peptide levels and global longitudinal strain, as well as ongoing trials of transcatheter aortic valve replacement in asymptomatic patients and patients with moderate aortic stenosis complicated by symptoms or left ventricular systolic dysfunction. Given the high mortality associated with severe symptomatic aortic stenosis, all symptomatic patients should be referred for aortic valve replacement. Asymptomatic patients with left ventricular systolic dysfunction, abnormal exercise stress test, high degree of stenosis, rapid disease progression, or elevated serum B-type natriuretic peptide level may also have an indication for valve replacement, based on established criteria. The progress in management of severe aortic stenosis has been in the direction of earlier detection and earlier valve replacement.


Subject(s)
Aortic Valve Stenosis , Ventricular Dysfunction, Left , Humans , Natriuretic Peptide, Brain , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve/surgery , Risk Assessment , Severity of Illness Index
18.
J Am Coll Cardiol ; 81(5): 431-442, 2023 02 07.
Article in English | MEDLINE | ID: mdl-36725171

ABSTRACT

BACKGROUND: Mitral valve transcatheter edge-to-edge repair is safe and effective in treating degenerative mitral regurgitation (DMR) patients at prohibitive surgical risk, but outcomes in complex mitral valve anatomy patients vary. OBJECTIVES: The PASCAL IID registry assessed safety, echocardiographic, and clinical outcomes with the PASCAL system in prohibitive risk patients with significant symptomatic DMR and complex mitral valve anatomy. METHODS: Patients in the prospective, multicenter, single-arm registry had 3+ or 4+ DMR, were at prohibitive surgical risk, presented with complex anatomic features based on the MitraClip instructions for use, and were deemed suitable for the PASCAL system by a central screening committee. Enrolled patients were treated with the PASCAL system. Safety, effectiveness, and functional and quality-of-life outcomes were assessed. Study oversight also included an echocardiographic core laboratory and clinical events committee. RESULTS: The study enrolled 98 patients (37.2% ≥2 independent significant jets, 15.0% severe bileaflet/multi scallop prolapse, 13.3% mitral valve orifice area <4.0 cm2, and 10.6% large flail gap and/or large flail width). The implant success rate was 92.9%. The 30-day composite major adverse event rate was 11.2%. At 6 months, 92.4% patients achieved MR ≤2+ and 56.1% achieved MR ≤1+ (P < 0.001 vs baseline). The Kaplan-Meier estimates for survival, freedom from major adverse events, and heart failure hospitalization at 6 months were 93.7%, 85.6%, and 92.6%, respectively. Patients experienced significant symptomatic improvement compared with baseline (P < 0.001). CONCLUSIONS: The outcomes of the PASCAL IID registry establish the PASCAL system as a useful therapy for prohibitive surgical risk DMR patients with complex mitral valve anatomy. (PASCAL IID Registry within the Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID] NCT03706833).


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Prospective Studies , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Cardiac Catheterization/adverse effects
19.
J Am Coll Cardiol ; 81(8): 743-752, 2023 02 28.
Article in English | MEDLINE | ID: mdl-36813373

ABSTRACT

BACKGROUND: The extent of extravalvular cardiac damage is associated with increased risk of adverse events among patients with severe aortic stenosis undergoing aortic valve replacement (AVR). OBJECTIVES: The goal was to describe the association of cardiac damage on health status before and after AVR. METHODS: Patients from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were pooled and classified by echocardiographic cardiac damage stage at baseline and 1 year as previously described (stage 0-4). We examined the association between baseline cardiac damage and 1-year health status (assessed by the Kansas City Cardiomyopathy Questionnaire Overall Score [KCCQ-OS]). RESULTS: Among 1,974 patients (794 surgical AVR, 1,180 transcatheter AVR), the extent of cardiac damage at baseline was associated with lower KCCQ scores both at baseline and at 1 year after AVR (P < 0.0001) and with increased rates of a poor outcome (death, KCCQ-OS <60, or a decrease in KCCQ-OS of ≥10 points) at 1 year (stages 0-4: 10.6% vs 19.6% vs 29.0% vs 44.7% vs 39.8%; P < 0.0001). In a multivariable model, each 1-stage increase in baseline cardiac damage was associated with a 24% increase in the odds of a poor outcome (95% CI: 9%-41%; P = 0.001). Change in stage of cardiac damage at 1 year after AVR was associated with the extent of improvement in KCCQ-OS over the same period (mean change in 1-year KCCQ-OS: improvement of ≥1 stage +26.8 [95% CI: 24.2-29.4] vs no change +21.4 [95% CI: 20.0-22.7] vs deterioration of ≥1 stage +17.5 [95% CI: 15.4-19.5]; P < 0.0001). CONCLUSIONS: The extent of cardiac damage before AVR has an important impact on health status outcomes, both cross-sectionally and after AVR. (PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - XT Intermediate and High Risk (PII A), NCT01314313; The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves - PII B [PARTNERII B], NCT02184442; PARTNER 3 Trial: Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis [P3], NCT02675114).


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/surgery , Quality of Life , Treatment Outcome , Health Status , Aortic Valve Stenosis/surgery , Risk Factors , Severity of Illness Index
SELECTION OF CITATIONS
SEARCH DETAIL
...